• Title/Summary/Keyword: 소음 감소치

Search Result 26, Processing Time 0.021 seconds

Correlation between Dynamic Characteristics of Isolation Material and Impact Noise Reduction of Light-weight Impact Source (충격음 저감재의 동특성과 실험실 경량충격음레벨 저감량의 상관관계)

  • 이주원;정갑철;권영필
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.05a
    • /
    • pp.191-195
    • /
    • 2003
  • 충격음 저감재의 동탄성계수와 감쇠계수는 차단성능을 평가하는데 있어 중요한 물성치가 된다. 저감재의 동탄성계수는 뜬바닥구조의 고유진동수를 결정짓게 되며, 저감재의 동탄성계수가 높을수록, 즉 고유진동수가 높아짐에 따라 실험실 경량충격음레벨 저감량은 지수함수적으로 감소됨을 실험을 통해 알 수 있다. 또한, 저감재를 포함한 뜬바닥구조를 1자유도 진동계로 가정한 이론값과 실험실 경량충격음레벨 저감량의 결과가 비교적 잘 일치하는 것으로 나타났으며, 이 때 감쇠계수의 영향은 반드시 고려되어야 한다.

  • PDF

Correlation between Proximity Noise Measurement Method (CPX) and Roadside Measurement Method (SPB) for Road Traffic Noise (도로교통소음에 대한 근접소음 측정법(CPX)과 통과소음 측정법(SPB)의 상관관계)

  • Yoo, In-Kyoon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.12
    • /
    • pp.310-319
    • /
    • 2020
  • Korea estimates the traffic noise by measuring the total traffic noise when the traffic passes (SPB; Statistical Pass-By). Another method (CPX; Close Proximity) directly measures the tire/road noise by installing a microphone near the tire. The CPX method is not a formal test method in Korea. There has been little research between CPX and SPB. This study proposes a method for estimating SPB, using the CPX, which is easy to measure. This study used the results of a large-scale test conducted by Korea Expressway Corporation (KEC) and a research paper on CPX in this section. The results by the KEC showed that the low noise pavement has a noise reduction of 10.4dB. In CPX research, the noise reduction was 10.7dB and was similar to 10.4dB in SPB. This study shows why the noise reduction is the same regardless of the position, the reason that the amount of noise reduction is similar, the difference of the noise according to the position of the microphone using the concept of noise summation and distance reduction. This study shows that including the CPX as a variable in the traffic noise prediction program is very important to improve noise prediction reliability.

Influence of the Nozzle Contraction Angles of Gaseous Extinguishing Systems on Discharge Noise (가스계 소화시스템 노즐 수축각이 방출소음에 미치는 영향)

  • Kim, Yo-Hwan;Yoo, Han-Sol;Hwang, In-Ju;Kim, Youn-Jea
    • Fire Science and Engineering
    • /
    • v.33 no.4
    • /
    • pp.77-82
    • /
    • 2019
  • Fire extinguishing systems are essential equipment in all indoor facilities to address unexpected fire scenarios, and appropriate fire extinguishing agent should be used depending on the place and object to protect. Among these, gaseous fire-extinguishing systems are used to protect electronic equipment. Therefore, inert gases that do not undergo chemical reactions are used mainly in those systems. On the other hand, recently, owing to the high integration of electronic equipment, there are some cases, in which large noise generated from gaseous systems damage the electronic equipment. In this study, numerical analysis of the discharge noise with various nozzle contraction angles was carried out to improve the gas fire extinguishing system. Numerical analysis was carried out using ANSYS FLUENT ver 18.1. The causes of the noise were elucidated using the swirl distribution. The noise level of the modified model was reduced by approximately 6 dB compared to the reference model, which is similar to the result of a previous study, confirming the validity of the method.

Vibration Estimation of Synchrotron Light Source Building Using Experimental Modal Analysis (실험적 모드해석을 이용한 방사광 가속기 건물의 진동평가)

  • 박상규;이홍기;권형오
    • Journal of KSNVE
    • /
    • v.5 no.3
    • /
    • pp.413-421
    • /
    • 1995
  • Synchrotron light source building of the accelerator has stringent vibration limits since the performance of the optical devices and electronic equipments in the laboratory is strongly influenced by the vibrations of the building. In this study, vibrations of the synchrotron light source building are estimated using experimental modal analysis and force response simulation technique. Dynamic properties of the building are identified from the modal parameters and vibration responses are predicted from the force response simulation. A double anti vibration system is designed and applied to the HVAC equipments and it has been shown that the measured vibrations of the building with the double anti vibration system satisfy the vibration criteria.

  • PDF

A Study on the Vibration Reduction Effect of a Soil Grouting (지반내 그라우팅공법에 의한 지반진동감소 연구)

  • Huh, Young;Cho, Jun-Sang;Koo, Yong-Woo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1995.10a
    • /
    • pp.104-110
    • /
    • 1995
  • 지반과 구조물의 동적 상호작용은 건설분야에서의 중요한 현상으로, 특히 지반을 통해 인근구조물로 전달되는 진동은 구조물 자체의 구조적인 문제 뿐 아니라 그 속에 거주하는 사람이나 설비에 대한 안전성 또는 사용성에 나쁜 영향을 야기할 수 있다. 본 논문에서는 이러한 진동을 저감시키기 위해, 지반내에 정상적인 진동전파를 방해하는 구조물을 시공하여 진동 저감효과를 만들어 내는 방법을 연구하였다. 이러한 연구의 발상은 다음과 같다. 충진지반에서의 지반진동의 진폭을 해석하면서 진동의 크기가 기저암의 위치에 따라 큰 영향을 받는 것을 알았고 이로부터 지반내에 인위적인 층을 만들수 있다면 지반진동의 크기를 변화시킬 수 있지 않을까라는 생각에서 본 연구를 시작하였다. 또한 지반 내에서의 정상적인 진동의 전파를 방해하기 위한 차진 구조물을 만드는 방법은 연약지반의 강도중대 또는 차수의 목적으로 주로 사용하고 있는 그라우팅공법의 사용이 가능할 것이므로, 기존의 그라우팅현장에서 만들어진 지반의 물성치들을 사용하여 경계요소법에 의한 수치해석적 방법을 택하였다. 본 연구에서는 그라우팅공법의 시공성에 관한 것은 포함되지 않는다. 본 논문에서는 지반의 구조를 경사구조와 수평지반구조라는 두가지 특징적인 경우에 대해 검토하였다. 이중 경사진 기저암층을 가진 지반의 경우에는 기저암에서 진동의 비대칭적인 반사에 의해 수평기저암에서와는 달리 기저암의 한쪽에서 다른쪽에 비해 큰 진동이 발생한다. 그라우팅층의 효과를 검토하기 위한 연구의 순서는 일정주파수의 조화진동에 대해 먼저 여러 가지 크기의 그라우팅층과 함께 블록으로 볼 수 있는 크기의 그라우팅층에 대해 진동저감효과를 해석하였고, 이를 통해 보강층의 소요크기 및 최적위치를 구하였다. 사용된 물성치는 실제 지하철 건설현장에서 나타난 지반물성치 및 그라우팅후의 지반강도 및 전단파전파속도를 이용하였다. 또한 마지막에서 검토된 기차하중에 대한 효과를 알아보기 위해 사용된 기차운행에 의한 지반가속도도 역시 측정된 값을 사용하였다. 그러나 당시의 기차운행속도가 낮아 정상적인 운행에서는 더 큰 값이 나올 것으로 판단되었으나 측정된 값을 그대로 사용하였다.

  • PDF

Environmental Pollution in Korea and Its Control (우리나라의 환경오염 현황과 그 대책)

  • 윤명조
    • Proceedings of the KOR-BRONCHOESO Conference
    • /
    • 1972.03a
    • /
    • pp.5-6
    • /
    • 1972
  • Noise and air pollution, which accompany the development of industry and the increase of population, contribute to the deterioration of urban environment. The air pollution level of Seoul has gradually increased and the city residents are suffering from a high pollution of noise. If no measures were taken against pollution, the amount of emission of pollutant into air would be 36.7 thousand tons per year per square kilometer in 1975, three times more than that of 1970, and it would be the same level as that of United States in 1968. The main sources of air pollution in Seoul are the exhaust has from vehicles and the combustion of bunker-C oil for heating purpose. Thus, it is urgent that an exhaust gas cleaner should be instaled to every car and the fuel substituted by less sulfur-contained-oil to prevent the pollution. Transportation noise (vehicular noise and train noise) is the main component of urban noise problem. The average noise level in downtown area is about 75㏈ with maximum of 85㏈ and the vehicular homing was checked 100㏈ up and down. Therefore, the reduction of the number of bus-stop the strict regulation of homing in downtown area and a better maintenance of car should be an effective measures against noise pollution in urban areas. Within the distance of 200 metres from railroad, the train noise exceeds the limit specified by the pollution control law in Korea. Especially, the level of noise and steam-whistle of train as measured by the ISO evaluation can adversely affect the community activities of residents. To prevent environmental destruction, many developed countries have taken more positive action against worsening pollution and such an action is now urgently required in this country.

  • PDF

Effect of Noise in Human Body (소음이 인체에 미치는 영향)

  • 이영노
    • Proceedings of the KOR-BRONCHOESO Conference
    • /
    • 1972.03a
    • /
    • pp.7-8
    • /
    • 1972
  • The effects of noise exposure are of two types: Nonauditory effects and auditory effects. Nonauditory effects of noise exposure are interference with communication by speech, sleeping and emotional behavior. The noise will cause the high blood pressure and rapid pulse, also that decrease the salivation and gastric juice. in experimentaly showed that the Corticoid hormon: Gonatotropic hormone were decrease and Thyrotropic hormoone is increase. Auditory effect of noise exposure. when the normal ear is exposed to noise at noise at hamful intensities (above 90㏈) for sufficiently long periods of time, a temoral depression of hearing results, disappearing after minutes or hours of rest. When the exposure longer or intesity greater is reached the Permanent threshold shift called noise-induced hearing loss. Hearing loss resulting from noise exposure presents legal as well as medical problems. The otologist who examines and evaluates the industrial hearing loss cases must be properly informed, not only concerning the otologic but also about the physical and legal aspects of the problems. The measurement of hearing ability is the most important part of a hearing conservation, both preplacement and periodic follow-up tests of hearing. The ideal hearing conservation program would be able to reduce or eliminate the hazardous noise at its source or by acoustic isolation of noisy working area and two ear protections (plugs and muff type) were developed for personal protection.

  • PDF

Vibration control of a single-link flexible manipulator using fuzzy- sliding modes (퍼지-슬라이딩 모드를 이용한 단일링크 유연 매니퓰레이터의 진동제어)

  • Choi, Seung-Bok
    • Journal of KSNVE
    • /
    • v.6 no.1
    • /
    • pp.35-44
    • /
    • 1996
  • This paper presents a new type of fuzzy-sliding mode controller for robust tip position control of a single-link flexible manipulator subjected to parameter variations. A sliding mode controller is formulated with an assumption that imposed parameter variations are bounded so that certain deterministic performance can be guaranted. In the design of the sliding mode controller, so called moving sliding surface is adopted to minimize the reaching phase and thus mitigate system sensitivity to the variations. The sliding mode controller is then incorporated with a fuzzy technique to reduce inherently ever-existing chattering which is impediment in position control of flexible manipulators. A set of fuzzy parameters and control rules are obtained from a relation between predetermined sliding surface and representative points in the state space. Computer simulations are undertaken in order to demonstrate superior control performance of the proposed methodology.

  • PDF

Optimal Design of a PMLSM having 9 Pole 10 Slot for Detent Force Reduction (디텐트력 저감을 위한 9극 10슬롯 영구자석 선형 전동기의 최적설계)

  • Hwang, In-Sung;Yoon, Hee-Sung;Koh, Chang-Seop
    • Proceedings of the KIEE Conference
    • /
    • 2007.10c
    • /
    • pp.101-103
    • /
    • 2007
  • 최근 영구자석 선형 동기 전동기(PMSLM)는 이동 장치로써 많은 분야에 사용되고 있다. 영구자석 선형 동기 전동기는 구조적으로 간단하며 고속화 고추력화 등의 많은 장점을 가지고 있다. 그러나 단 1차형 영구자석 선형 동기 전동기는 매우 큰 디텐트력을 지니고 있어 추력 맥동의 원인이 되며, 이는 소음과 진동을 발생시킨다. 단 1차형 영구자석 선형 동기 전동기의 디텐트력은 전기자 내부의 치와 영구자석 사이에 작용하는 힘과 전기자 양 단부와 영구자석 사이에서 작용하는 힘의 합으로 표현된다. 본 논문에서는 코킹력이 획기적으로 감소한 9극 10슬롯 모델의 단부력을 줄이기 위한 방법으로 양 단부에 전기자 길이 조정법과 챔퍼링 법을 사용하였고, 반응표면법과 ($(1+{\lambda})$ evolution strategy)을 이용하여 최적화를 수행하였다.

  • PDF

A Study on the Active Noise Control in Duct (닥트내 소음의 능동제어에 관한 연구)

  • Lee Chai-Bong
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.7 no.3
    • /
    • pp.130-135
    • /
    • 2006
  • There have been experiments dealing with the possibility of the actualization of the ANC system by means of operating the DSP adaptation filter. This filter is composed of various filters(including X-LMS algorithm, Filter-U algorithm, and Full-Feedback-Filter-U algorithm) that use ventilation fans and loudspeakers as a primary source in a circular duct as an experimental device. In this operation, the ANC system using the X - LMS algorithm was found to be more effective in reducing noise than without such system. When applying the input signal of the DSP board Full Feedback-Filtered-U algorithm system while having in mind that the additionally installed second control signal was gone through feedback and mixed into the detection microphone installed near the ventilation fan when using the first ventilation fan, the system was not emitted, but maintained stable during the operation of the control filter. At this point, noise tended to decrease at a maximum of l0dB compared to other algorithms at the frequency band of 170-250Hz.

  • PDF