• Title/Summary/Keyword: 소손

Search Result 160, Processing Time 0.027 seconds

Study for Failure Cases on Engine Electronic Control Computer in Liquid Petroleum Gas vehicle (액화석유가스 자동차 엔진의 전자제어 컴퓨터의 고장사례 연구)

  • Lee, Il-Kwon;Kim, Young-Gyu;Kook, Chang-Ho
    • Journal of the Korean Institute of Gas
    • /
    • v.15 no.6
    • /
    • pp.28-33
    • /
    • 2011
  • The purpose of this paper analyzes and studies to improve the failure cases on the computer that one of electronic control elements for engine in liquified petroleum gas vehicle. The first case, it certified the non-starting phenomenon of engine that it's electronic control unit didn't control the fuel for idle speed actuator because of no given action signal in slow-cut solenoid valve. The second case, it knew the bad condition phenomenon of engine and back-fire by the wire melting of ignition coil and firing of transistor being inside ECU. The third case, it certified the action stoping phenomenon of engine and malfunctioning signal for engine ECU because of leakage of current and an excess current by moisture inflowing inside ECU curcuit plate. Therefore, it is thought that will elevate the durability and reliability of engine computer throughout procure of quality.

A Study on the Flame Pattern and the Electrical Properties of Electric Outlet Fired at Standby Mode (Standby Mode에서 출화된 콘센트의 화염 패턴 및 전기적 특성에 관한 연구)

  • 최충석;송길목;김형래;김향곤;김동욱;김동우
    • Fire Science and Engineering
    • /
    • v.16 no.1
    • /
    • pp.39-44
    • /
    • 2002
  • In this paper, we analysed the flame patterns and the electrical characteristics of the electric outlet which was fired at standby mode. The carbonized patterns indicated that the flame had spread about 50 cm to 70 cm. After the combustibles on wall started to burn, the temperature went up to about $300^{\circ}c$ in 150 sec. The flame formed ceiling jet and spread quickly. The tracking was generated at the shortest distance between two electrodes and the resistance was about 100$\Omega$ to 300$\Omega$ As the result of analysis using metallurgical microscope, the normal part of a blade holder showed amorphous structure, but the melted part of a blade holder damaged by tracking showed dendrite structure and void evenly. When the blade holder of damaged outlet was analyzed by SEM and EDX, we found that the structure and components of the normal part were different from those of melted part.

The Characteristics Analysis of Damaged Pattern by Repeated Stress of VCTFK (VCTFK의 반복피로에 의한 소손 패턴의 특성 해석)

  • Choi Chung-Seog;Shong Kil-Mok;Kim Dong-Woo
    • Journal of the Korean Society of Safety
    • /
    • v.19 no.4 s.68
    • /
    • pp.42-47
    • /
    • 2004
  • In this paper, we analyzed on the characteristics of the stranded wire disconnected by repeated stress. The stranded wires that were used in the experiment are PVC insulated flexible cords(VCTFK: Vinyl Insulated Vinyl Cabtyre Cord Flat-type) of $0.75mm^2,\;1.25mm^2,\;and\;2.0mm^2$. They are used to connect the load in low voltage. The stranded wires disconnected by repeated stress were magnified with optical microscope. Using X-ray, the disconnected wire were photo-graphed. we compared mechanical characteristics of the stranded wire between disconnected tendency and allowable current. On the mechanical strength of vinyl cap tire ellipse type cords under bending stress, VCTFK of $1.25mm^2$ was the strongest of them. When it was bent $826.3\pm7$ times, it appeared the disconnected tendency that element wires of VCTFK of $1.25mm^2$ are more about 1.67 times than element wires of VCTFK of $0.75mm^2$. In mechanical strength, VCTFK of $1.25mm^2$ is higher about 1.7 times than VCTFK of $0.75mm^2$. Therefore, we found out that mechanical strength was higher, when the wire had a lot of element wires. In comparison with bending stress, VCTFK of $1.25mm^2$ is the strongest among samples, and it is the most useful in wires of movable type.

72[W] Power LED Photovoltaic Lighting System including the Current Limiting Function (전류제한 기능을 갖는 72[W ]급 파워 LED 태양광 보안등)

  • Park, Hyo-Sik;Han, Woo-Yong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.8
    • /
    • pp.2999-3004
    • /
    • 2010
  • In comparison with some other light sources, LED has merits such as long lifetime, pollution free, and high energy efficiency. Lately, due to development of LED with high brightness and capacity, LED, which has been applied in display system only, has applied in the field of lighting system. As power LED for lighting system can be burned out by heat problem, the driving current of power LED has to be controlled below the designed value. In this paper, power LED photovoltaic lighting system, which has the current limitting function, has been described. After photovoltaic power is generated from PV panel. it is charged into a battery. And then, after the charged power is converted to DC24[V] through a boost DC-DC converter, it is supplied to power LED at night. It has been validated by designing and testing of 72[W] power LED lighting system, which includes a PV charger, a boost DC-DC converter and a current limiter for driving power LED.

Development of a constant pressure feed system using a constant pressure proportional control mode (정압비례제어방식을 적용한 정압급수장치의 개발)

  • 김주명;김광열;이건기
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.7 no.5
    • /
    • pp.1026-1031
    • /
    • 2003
  • Automatic feed pumps are operated and stopped by a pressure switch. Thus, because of repeated operations and stops of the pumps according to fluctuations of water volume, operation with constant rate and pressure is impossible. Moreover, because of repeated running of the pump, keeping up of constant pressure is impossible and damage and energy loss are weak points of the pimps. To make up for defects of an automatic feed pump, this paper designed and made a static pressure feed system which was composed of a feed water control valve, a flow sensor and a control system. The valve device plays an important part in reducing load of pumps by constant water supply regardless of outflow of water. Outflow of water is determined by infrared diode of the flow sensor. The control system is made of a 8 bit micro-processor and the pump was controled by a specific control algorithm. With the constant pressure feed system, discharge pressure was kept at fixed pressure, accurate operations and stops were smoothly accomplished and the pump was operated with constant pressure. Thus, the constant pressure feed system can be considered as an advanced system which made up for the weak points in the current automatic feed systems.

Soft Start-up Algorithm of Single-Phase Induction Motor Based on Full-bridge Inverter (풀 브리지 인버터 기반 단상 유도전동기의 소프트 기동 기법)

  • Kim, Tae-Seong;Kang, Hyung-Do;Hwang, Seon-Hwan
    • Journal of IKEEE
    • /
    • v.22 no.2
    • /
    • pp.258-265
    • /
    • 2018
  • This paper proposes an algorithm for reducing the starting current when the single-phase induction motor starts and analyzes its operation. Generally, the single-phase induction motors require several starters to generate the starting torque due to their structural characteristics. In this paper, a capacitor-start / capacitor-run method of the single-phase induction motor is basically adopted. This conventional method is efficient and has a large starting torque, but it generates about 5 ~ 6 times of inrush current at startup. As a result, the freezer starting device and peripheral devices are damaged and life time may be reduced. To reduce the inrush current, the current control algorithm based on the virtual dq model is presented to control the starting current. In addition, it validates the proposed algorithm through experiments to smooth transit from start-up operation to the rated operating region.

Research on Overheat Protection Techniques of Connection Parts of MCCB by Poor Contact (MCCB 단자 접속부의 접촉불량에 의한 과열사고 방지기법에 관한 연구)

  • Kim, Dong-Woo;Lee, Ki-Yeon;Moon, Hyun-Wook;Kim, Hyang-Kon;Cho, Chung-Seog
    • Fire Science and Engineering
    • /
    • v.22 no.4
    • /
    • pp.54-60
    • /
    • 2008
  • In this study, damage characteristics of MCCB and terminal block due to poor contact were analyzed, and various poor contact detection techniques were suggested. Firstly, the detection techniques using thermocouple and infrared thermal camera were analyzed respectively. Also, thermo-cap during poor contact detected abnormal status effectively by changing its color, and the detection system using an odor detector and odor capsules was analyzed. Lastly, poor contact detection screw was made using characteristics of fusible alloy, and we applied the poor contact detection screw to terminal block. The above methods could prevent electrical fire caused by poor contact effectively if they are used properly.

Cause Analysis Ignited at a Far Infrared Radiation Heater (원적외선 히터에서 출화된 화재의 원인분석)

  • Kim, Dong-Ook;Choi, Chung-Seog
    • Fire Science and Engineering
    • /
    • v.22 no.2
    • /
    • pp.91-96
    • /
    • 2008
  • This research studied about the cause analysis of fire that was occurred in far infrared rays heater to base on the fire examples. Fire of electric heater was apt to commit error that handled an over-heating accident by judged molten mark in heat ray. Molten mark which was attached in heat ray was appeared to the form of layer short circuit by other metal material, but other metal material was not found beside the ingredient of heat wire which was mixed to an alloy of Fe-Cr-Al according to result of ingredient distribution by SEM/EDX. Also, the result of overheating experiment by layer short circuit and overvoltage showed higher febrility than normal, but there was no possibility of fire occurrence. This paper will be contributed to science for cause analysis of electric fire through analyzing physical, chemical and flame features of burnout heater on the basis of diagnosis of fire that was happened in infrared rays heater.

A Study on Dynamic Characteristics of EFPCD for Electrical Fire Prevention (전기화재 예방을 위한 EFPCD동작 특성에 관한 연구)

  • 이상호;오홍석
    • Fire Science and Engineering
    • /
    • v.16 no.3
    • /
    • pp.8-11
    • /
    • 2002
  • Recently, the spark and the overheat due to in the failure of pressure contacts on connecting points and the momentary short circuit have been the major causes of electrical fire because these may cause the deposition and the graphite of insulating materials in electrical wiring system. Also, because in these cases the current is a surge one, the losses and faults of a communication, a home appliances, a computer and a measuring instrument may occur. Especially, in such cases, we are very difficult to detect the failure of pressure contacts on connecting points and the momentary short circuit. In this paper, we have developed an auxiliary control device, the electrical fire prevention control device(EFPCD), of an earth leakage breaker(ELB). And we can pre-vent the electrical fire caused by the spark and the overheat occurring in the failure of pressure contacts in connecting points and the momentary short circuit with the EFPCD.

A Study on the Damaged Pattern of Dryvit by External Flame (외부화염에 의한 드라이비트의 소손패턴 연구)

  • Park, Young Ju;Hong, Yi Pyo;Lee, Hae Pyeong
    • Journal of the Korean Society of Safety
    • /
    • v.30 no.6
    • /
    • pp.40-47
    • /
    • 2015
  • In this study, temperature characteristics and fire damage form were analyzed to investigate flame spreading form and fire probability from ignition sources subject to drivit component materials which is finishing material in architecture. Ignition sources were limited to a gas torch and exterior panel board fire, and the size of the sample was manufacture in 30 cm length ${\times}$ 50 cm height ${\times}$ 5cm thickness size. Marble (inner wall) + 3 mm drivit (outer wall), marble (inner wall) + 4 mm plaster stone (outer wall), sandwich panel + 3 mm driver bit (outer wall), sandwich panel + 3 mm driver bit + insulation (outer wall), and gypsum board (inner wall) + 3 mm drivit (outer wall) were prepared for the sample. As result of the research for temperature characteristics, large temperature difference by each material was shown in $218^{\circ}C{\sim}995^{\circ}C$ at 30 seconds and $501^{\circ}C{\sim}1078^{\circ}C$ at 300 seconds. Especially when the inner wall was a plaster board, lowest temperature of $501^{\circ}C$ was shown at 300 seconds and marble inner wall showed the following lowest temperature of $900^{\circ}C$. Temperature rising over $1000^{\circ}C$ was shown in other materials. Regarding fire damage form, drivit or gypsum board outer wall parts exposed to fire showed combustion and carbonization to show calcination(breaking phenomenon) and influence of heat exposure was higher as calcination became more severe.