• Title/Summary/Keyword: 소방용 배관

Search Result 39, Processing Time 0.017 seconds

A Study on Seismic Protection Equipment for Fire Pipes Installed on Buildings (건축물에 설치되는 소방용 배관의 내진장치에 관한 연구)

  • Lim, Geon-Tae;Lim, Sang-Ho
    • Industry Promotion Research
    • /
    • v.4 no.1
    • /
    • pp.1-9
    • /
    • 2019
  • This study is a technology related to a seismic protection device for a fire pipe for installation in a building such as an apartment or a building. The fire pipe is fixed to the base panel by fastening bolts so as to flow left and right. The present invention relates to an earthquake-resistant apparatus for a fire-extinguishing piping, which is capable of minimizing damages caused by an earthquake in order to prevent damages and breakage of a fire-extinguishing pipe by mitigating earthquakes, vibrations, It is connected to an insert plate embedded in concrete or ceiling hanger bolts formed at regular intervals on the ceiling to keep the piping constant from the ceiling and to keep the horizontal condition of the piping always constant so that the piping relaxes or sags And to effectively prevent damage to the piping. The can get.

A study on optimization design of sealing for sprinkler fire pipe system (스프링쿨러 소방 배관용 시일의 최적설계에 관한 연구)

  • Kim, Kyung-Seob;Kim, Chung-Kyun
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2010.10a
    • /
    • pp.302-307
    • /
    • 2010
  • 본 연구는 최적설계 기법의 하나인 다구찌 방법을 이용하여 소방용 스프링클러 배관용 밀봉부에 대한 유한요소해석을 수행하고, 이를 통하여 소방용 배관의 밀봉안전성을 확보하고자 한다.

  • PDF

A study on deformation characteristics of fire pipe with sharp change by using Finite Element Method (유한요소해석을 이용한 소방용 배관의 형상변화에 따른 변형특성에 관한 연구)

  • Kim, Kyung-Seob;Kim, Chung-Kyun
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2010.10a
    • /
    • pp.308-311
    • /
    • 2010
  • 본 연구에서는 유한요소해석을 통하여 나선 주름모양 소방용 파이프를 모델링하여 각 모델간의 발생응력과 변형량을 상호간에 비교 검토하여 강도 안전성이 우수한 배관시스템의 설계 최적화를 하기 위함이 연구의 목적이다.

  • PDF

A study on deformation characteristics of fire pipe with spiral sharps by using Taguch's method (다구찌법을 이용한 나선모양 소방배관의 변형특성 연구)

  • Kim, Kyung-Seob;Kim, Chung-Kyun
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2010.10a
    • /
    • pp.7-11
    • /
    • 2010
  • 본 논문에서도 유한요소해석과 최적설계 기법의 하나인 다구찌 방법을 이용하여 나선모양을 갖는 소방용 배관의 최적설계를 통하여 배관의 강도 안정성을 확보하고자 한다.

  • PDF

A Study on the Application of Hydraulic Calculations considering the Corrosion Coefficient of Steel Piping for Fire Protection (소방용 강관배관 부식계수를 고려한 수리계산 적용방안에 관한 연구)

  • Mun, Chul-Hwan;Kang, Ho-Jung;Choi, Jae-Wook
    • Fire Science and Engineering
    • /
    • v.34 no.4
    • /
    • pp.69-77
    • /
    • 2020
  • With the recent enlargement and complication of buildings, damage caused by the incidents of fires breaking out are escalating. Consequently, the use of sprinkler facilities is increasing among water-based fire extinguishing systems. Piping materials used in fire prevention systems include carbon steel (for general or pressure pipeline), CPVC, copper, and stainless-steel. Among these, the steel and CPVC pipes, which are commonly employed in fire prevention, were considered for testing the reliability of the water-based systems. This analysis was performed using the PIPENET software to perform hydraulic calculations in order to examine the flow and pressure at the terminal head when the corrosion coefficient was applied; this coefficient was applied considering the aging of pipes. Assuming a uniform pipe diameter in the steel pipes, the rated flow in the pump installed on the first floor of the basement was reduced by over 10% after 20 years had passed (C value of 90); moreover, the reduction in pressure and flow at its terminal head exceeded 30% and 16.5%, respectively. The results indicate that it is difficult to ensure the reliability of these fire prevention facilities. Furthermore, according to our estimation, considering 30 years had passed (C value of 80), the rated flow of the pump was reduced by over 15%, and the corresponding reduction in pressure and flow at its terminal head exceeded 42% and 24%, respectively.

Numerical Analysis of Unsteady Heat Transfer for Location Selection of CPVC Piping (CPVC 배관 동파방지용 열선의 위치 선정을 위한 비정상 열전달 수치해석)

  • Choi, Myoung-Young;Choi, Hyoung-Gwon
    • Fire Science and Engineering
    • /
    • v.29 no.6
    • /
    • pp.33-39
    • /
    • 2015
  • In this paper, a numerical experiment was conducted to find out the optimal location of electrical heat trace for anti-freeze of water inside the CPVC pipe for fire protection. The unsteady incompressible Navier-Stokes equations coupled with energy equation were solved. Since the conduction equation of pipe was coupled with the natural convection of water, the analysis of conjugate heat transfer was conducted. A commercial code (ANSYS-FLUENT) based on SIMPLE-type algorithm was used for investigating the unsteady flows and temperature distributions in water region. From the present numerical experiment, it has been found that the vector field of water inside the PVC pipe is opposite to the case of steel because of the huge difference of material properties of the two pipes. Furthermore, it was found that the lowest part of the pipe was an optimal position for electrical heat trace since the minimum water temperature of the case was higher than those of the other cases.

A numerical study on deformation characteristics of bracket for fire pipe system (소방 배관용 브라켓의 변형특성에 관한 수치적 연구)

  • Kim, Kyung-Seob;Kim, Chung-Kyun
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2010.10a
    • /
    • pp.312-318
    • /
    • 2010
  • 본 연구에서는 배관계에 가해진 압력으로 인하여 변형된 배관에 의하여 영향을 받는 브라켓에 대하여 여러 가지 형상으로 모델링하여 유한요소해석을 통하여 브라켓의 형상변화가 변형특성에 미치는 영향을 고찰 하였고, 배관시스템의 브라켓의 강도 안전성을 확보하기 위하여 산업공학에서 쓰였던 다구찌방법을 도입하여 최적화 설계를 하는 것이 본 연구의 목적이다.

  • PDF

An Experimental Study on Piping Feasibility of PE Compound Pipe for Fire Protection Service (PE 이종강관의 소방용 배관 적용성에 관한 실험적 연구)

  • Park, Jeong-Hwa;Oh, Cheon-Young;Kwark, Ji-Heon;Son, Bong-Sei
    • Fire Science and Engineering
    • /
    • v.30 no.3
    • /
    • pp.55-61
    • /
    • 2016
  • In this study, to determine whether it is possible to apply Polyethylene (PE) compound pipe, which was developed to solve the problem caused by the corrosion of the fire protection piping currently in usein water based fire extinguishing systems, we performed an actual mockup fire test. Since no test standard was available related to the developed compound pipe, we compared and analyzed domestic and international technical materials and test standards and selected suitable fire test standards to evaluate the performance of the PE compound pipe. we applied two fire test standards to the PE compound pipe, viz. those for CPVC and metallic pipes, and conducted a total of 6 experiments to evaluate its performance. According to the results of the first and second fire tests based on the test standard for the CPVC pipe, neither the fitting nor the piping was damaged or deformed and no leakage was observed in the pressure test, which was performed for 5 minutes. For the fire test based on the metallic pipe test standard, a total of 4 experiments were conducted. The first two experiments were conducted to simulate the wet piping system. In the results of this fire test, neither leakage nor rupture was observed from the PE compound pipe and no damage was caused, such as the secession of the PE material. However, in the next two experiments, which simulated the dry system, the PE compound pipe suffered damage and rupture, including deformation before the fire fighting water was discharged. Therefore, we found that the piping performance of the PE compound pipe did not undergo any deterioration, including fusion, deformation, or damage, in the wet piping system simulated fire test.

A Characteristic Comparison of Copper Pipe and Strain less Pipe used in Fire Protection System (소방배관에 사용되는 동관과 스테인리스관의 특성 비교)

  • Nam, Jun-Seok;Lee, Young-Sik;Kim, Yeong-Ho;Won, Sung-Yun
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2010.04a
    • /
    • pp.200-206
    • /
    • 2010
  • 건축환경의 변화에 따라 최근 스테인리스배관을 소방배관에 사용하고자 하나 국가화재안전기준에 관련근거가 없어 사용이 어려운 것이 현실이다. 따라서 본 논문에서는 이 기준에서 사용할 수 있는 배관가운데 동관(KS D 5301)과 일반배관용 스테인리스 배관(KS D 3595)의 성능비교를 통하여 사용가능성을 확인하였다. 비교한 성능은 강도, 내식성 및 내열성이며 유한요소해석과 관련 시험을 통해 성능을 비교한 결과 동등이상임을 확인할 수 있었다.

  • PDF

Measures applied for fire protection system of Light gauge strainesss steel pipe and the fittings for ordinary piping (일반배관용 스테인리스강관 및 이음쇠의 소화설비 적용 방안)

  • Nam, Jun-Seok;Choi, Jin-Jong;Kim, Yong-Ho;Park, Joo-Hwan
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2011.11a
    • /
    • pp.83-86
    • /
    • 2011
  • 옥내소화전설비, 스프링클러설비 등 수계소화설비에 일반배관용 스테인리스강관과 그 연결에 필요한 이음쇠의 사용가능성을 적용사례, 내식성 등을 통해 확인하였고, 기존 수계소화 설비의 배관에 대한 개선방안을 도출하였다. 일반배관용 스테인리스강관 및 이음쇠는 국내의 경우 수도용으로 활발히 사용되고 있으며, 독일 영국 일본 미국 등의 수계소화설비에 사용되고 있음을 확인할 수 있었다. 강관과 이음쇠의 연결상태에서 내식성을 확인하기 위해 0.5 %와 3.5 %의 소금물을 관내에 주입한 후 28일 보관한 결과 이상이 없음을 확인하였다. 또한, 기존에 설치되어있는 수계소화설비는 배관계의 온도차에 의한 보상방법이 되어있지 않아 작동물질의 열팽창에 따라 강관, 이음쇠의 파손이 발생할 수 있음을 확인하었다.

  • PDF