• 제목/요약/키워드: 소방용 방화복

검색결과 5건 처리시간 0.021초

한국 소방용 방화복에 대한 만족도 조사 (A Survey of Korean Firefighters Regarding their Satisfaction with Protective Clothing)

  • 한설아;남윤자;최영림
    • 복식
    • /
    • 제58권9호
    • /
    • pp.166-175
    • /
    • 2008
  • For the structural firefighting protective clothing, it can show a synergy effect when it satisfies smart fabric to block off a harmful environmental element and ergonomics design that apply range of motion of human body and appropriate size system. There are various standards about the structural firefighting protective clothing, but it's difficult to find a rule about movement suitability because the performance of the material holds a lot of the rules. Therefore, the purpose of this study is to propose a scheme to evaluate the current structural firefighting protective clothing and to improve movement suitability by research on the actual condition. For this, the survey about wearer acceptability scale on design and size and about improvement requirements was executed gathering firefighters' opinion. Questionnaire was composed with 23 items about satisfaction on current structural firefighting protective clothing, body suitability, movement suitability, improvement requirement and subjective information. As a results, Korean firefighters demand ergonomics design of structural firefighting protective clothing which to minimize restriction of body movement and to maximize body suitability.

한국 소방용 방화복의 치수체계 개발 (Sizing System Development of Korean Structural Firefighting Protective Clothing)

  • 한설아;남윤자;최영림
    • 한국의류학회지
    • /
    • 제33권5호
    • /
    • pp.827-839
    • /
    • 2009
  • Sizing system of Korean structural firefighting protective clothing that is national approved should be met for specification of structural firefighting protective clothing that is identified by Ministry of Public Administration and Security(MOPAS). However if you look over the specification of sizing system, the standard is based on only 'height' and the others are indicated as the size of completed product. KS K ISO 13688 and EN 340 which is met on ISO 13688 which indicates sizing system about protective clothing has the standards of height, chest and waist circumference. Also NFPA 1971 that has standards of sizing system is based on chest circumference, cervical to wrist length, waist circumference and inseam. That is different from Korean standards. Therefore, fire fighting protective clothing standards which is based on only height should be compensated and not be relied on foreign standards like ISO. It is indispensable for developing our own sizing system of structural fire fighting protective clothing. In this studying, Korean new sizing system of structural fire fighting protective clothing was developed for providing basic information of ergonomic structural fire fighting protective clothing. The analyzed target age was between 20 and 59 years old fire fighter who extinguish the fire. And it was analyzed by 3D measurement among data of the $5^{th}$ Size Korea. On conclusion, in case of structural fire fighting protective clothing coat, physical dimension was to be chest circumference, cervical to wrist length. Three dimensions as 5cm space of circumference and four dimensions as 2.5cm space of cervical to wrist length were derived, which means that totally 12 dimensions were defined. Dimension standards of pants was based on the analysis of waist circumference and crotch height. Six dimensions as 5cm space of waist circumference and three dimensions as 5cm space of crotch height were derived, which means that totally 14 dimensions were defined.

소방용 방화복 및 방화 장비에 따른 상반신 관절 각도의 동작 범위 연구 (Impact of Firefighters' Protective Clothing and Equipment on Upper Body Range of Motion)

  • 김선영;박희주
    • 한국의류산업학회지
    • /
    • 제17권4호
    • /
    • pp.635-645
    • /
    • 2015
  • This study analyzed the range of motion of upper body in different configurations of firefighters' protective clothing and equipment. The purpose of this study was to understand the influence of firefighters' protective clothing and equipment over upper body motion in order to improve design of firefighters' protective clothing and equipment. 12 firefighters' upper body range of motion was analyzed while performing standing and walking trials in five different garment configurations including turnout ensemble, fire boots and the self-contained breathing apparatus. Analysis of upper body range of motion included spinal joints of L5S1, L4L3, T1C7, and C1Head. During standing trials, garment configurations caused a significant difference in range of motions at joints of L5S1, L4L3, T1C7, and C1Head. Analysis on the mean of range of motions at L5S1 and L4L3, showed that firefighters' waist bent forward significantly to a greater extent while they wore a self-contained breathing apparatus. A significantly increased range of motion was found for T1C7 and C1Head while carrying a self-contained breathing apparatus, which indicated an increase in the extension of the trunk and neck backward to stand upright and look squarely. A significant difference in range of motion was also found for L5S1 and L4L3 during walking trials.

구획화재 시 국부복사열에 노출된 유리면의 수막접촉에 따른 급냉파열특성 관한 실험적 연구 (Experimental Study on Interaction of Water Sprayed Curtain on Hot Surface of a Window Glass and its Effects on Glass Surface Temperature in Room Fires)

  • 박형주;지남용
    • 한국화재소방학회논문지
    • /
    • 제17권4호
    • /
    • pp.124-130
    • /
    • 2003
  • 본 연구는 방화구획에 적용 가능한 수막형성유리벽에의 직근에 화원이 위치하는 경우 국부복사열에 의해 수막형성전 유리면이 가열된 상태에서 상부 수막분사노즐에서 분사되는 수막이 접촉함에 따른 급냉파열현상을 규명하기 위한 연구이다. 유리면 직근에서 국부복사열을 주는 실화재실험을 실시하여 분석하면 보통유리는 유리면 포면온도(가열측)가 $100^{\circ}C$를 넘는 경우에 수막을 접촉시킬 경우 파열이 발생하며, 강화유리는 유리 가열면 온도가 $250^{\circ}C$이상일 때 수막형성에 의한 급냉 파열이 발생함을 알 수 있었다. 향후 강화유리에 수막을 도포시키는 현재 방화구획에 사용되고 있는 유리의 대다수가 강화유리인 것을 감안하면 수막의 도포이전에 강화유리면의 온도가 $300^{\circ}C$이내에서는 수막을 유리면에 급속히 접촉시켜도 유리면의 급냉 파열이 일어나지 않음을 발견하였다. 따라서 일정한 공간구획 내에서 화재발생시 유리면의 직근에 화원이 위치하여 국부적으로 복사열을 가할 경우에도 화원상부 천정면에 설치된 감지시스템에 의해 한계온도이전에 수막형성시스템을 작동시켜 급냉파열현상을 발생시키지 않는다면 수막형성유리벽을 실제 방화구획의 경계벽으로 사용하는데 있어서 예측가능한 장애요인을 제거하는 데 비약적인 공헌을 한 것에 그 의미를 둔다.

수막보호 유리벽의 가열면 온도변화에 따른 급냉파열특성에 관한 연구 (A Research on Glass Breakage Vs. Surface Temperature on Fire Exposed Glass for The Water Film Cooling-down Glazing System)

  • 박형주;지남용;김창훈
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2001년도 추계학술대회 논문집
    • /
    • pp.301-310
    • /
    • 2001
  • 본 연구는 내화성능을 가진 수막보호유리벽을 실제 건축물에 적용하는데 있어서 필수적으로 고려해야 할 가상시나리오 중에서 수막이 유리면을 보호하기 이전에 유리면에 근접되어 있는 화염으로부터 방출되는 복사열이 유리면이 가열된 상태에서 수막이 형성될 경우 유리면의 온도가 급속히 냉각됨으로서 발생할 수 있는 급냉파열특성을 규명하기 위해 실험한 연구로서 가열면온도범위에 따라 유리면에$150^{\circ}C$이상 $250^{\circ}C$이하에서 수막이 형성될 경우 급냉파열은 일어나지 않았으나 일반유리는 $100^{\circ}C$이상 $150^{\circ}C$이하에서 급냉파열이 일어남을 확인하였다. 즉 방화구획벽에 적용가능한 수막형성유리벽의 유리가 강화유리인점을 착안하면 수막의 도포이전에 강화유리면의 온도가 $250^{\circ}C$까지 올라가기 전에는 수막을 유리면에 접촉하여도 유리면의 급냉파열이 일어나짐 않음을 확인할 수 있었다. 이점은 일정한 구획내에서 유리면의 직근에 설치된 감지기에 의해 수막형성시스템의 가동을 할 경우 급내파열형상이 발생하지 않는 온도범위를 설정할 때 중요한 데이터로 활용가능하다. 결과적으로 국부복사열에 의하여 온도범위를 설정할 때 중요한 데이터로 활용가능하다. 결과적으로 국부복사열에 의하여 유리면의 온도가 급냉파열현상을 일으키는 한계온도에 이르기 전에 유리벽체 상부의감지기의 작동이 필수적으로 일어날 수 있음을 증명한다면 수막을 이용한 유리벽체를 일정시간이상의 내화성능이 요구되는 방화구획의 수직부재로 활용하는데 있어서 걸림돌이 되는 급냉파열에 대한 우려를 종식시키는데 이바지할 수 있다.l류 11.56%, acid류 38.87%, hydrocarbon류 2.89%, ester류 0.80%, 총 70.32%가 확인되었다. Alcohol류에서 linalool가 3.78%, acid류에서는 caproic acid류가 14.40%, carbonyl류에서 2-hydroxy-4-methoxyacetophenone이 2.99%, hydrocabon류에서는 aromadendrene가1.59% 그리고 ester류에서는 methyl palmitate가 0.43%으로 가장 많이 함유하고 있었다.0ppm에서 약 25.6%흡수되었고 ferric citrate 100ppm은 24.7%, ferrous sulfate는 19.7%흡수되었다. ILC를 첨가하지 않은 100ppm 철분염 용액은 ferrous sulfate를 제외하고는 흡수도가 감소되었다. 철분 결핍된 쥐에게 gavage 방법에 의하여 철분강화우유를 투여하였을 때 철분 25ppm 시료에서는 ferrous sulfate가 12.5%로 가장 높았고 ferrous lactate는 8.1%, ferric citrate는 6.5% 흡수되었다. 철분 100ppm수준에서는 흡수율이 낮아져 ferrous sulfate는 25ppm 시료보다 절반이하 수준이었다. Ferric citrate는 차이가 거의 없었으며 ferrous lactate는 70%수준이었다. 이상의 결과에서 철분강화우유에 사용하기 적합한 철분염은 ferrous lactate, ferric citrate였는데 특히 ferrous lactate는 제품의 이화학적 품질, 생이용성 측면 모두에서 가장 좋은 것으로 나타났다.다 높았으며, 1회당 평균 8.1$\pm$5.1개의 난포란을 회수하였다.

  • PDF