• Title/Summary/Keyword: 세척유출수

Search Result 60, Processing Time 0.033 seconds

On a Cleaning of COVID-19 Prevention Masks with Electrolytic Decomposition Water (전기분해수로 코로나방역용 마스크의 세정에 관한연구)

  • Tian, Zhixing;Bae, Myung-Jin
    • The Journal of the Convergence on Culture Technology
    • /
    • v.8 no.1
    • /
    • pp.591-596
    • /
    • 2022
  • Various COVID-19 quarantine guidelines and measures are being taken by country at the WHO, but the number of confirmed cases has not decreased significantly. In order to prevent the inflow and outflow of COVID-19 through individual droplets, it is mandatory to wear a mask anytime, anywhere. However, as virus bacteria entering the mask amplify, it pollutes the mask and causes a disgusting smell. In this paper, a new method of preventing the spread of COVID-19 was proposed by sterilizing the mask with a dental gait spray introduced into the mask that has been used for a long time. Dental gargle water is usually produced by electrolysis of tap water, and the unstable ion water (HOCl) dissolved in water penetrates the cell barrier of various viruses and fails to act in its nucleus, causing water to self-purify. As a result of the experiment, when the mask used for a long time was washed with gargle water spray, the washed mask was dried after 10 minutes, and the smell of virus droplets or saliva almost disappeared. In particular, as a result of MOS testing the fit of the subjects who participated in the mask cleaning, it was excellent at 4.4 on average. Therefore, the mask was disposable, but if the spray was washed in the proposed method more than twice a day, the mask could be used in a comfortable state for more than a week.

An Analysis on the First Flush Phenomenon by Stormwater Runoff in Eutrophic Lake Watershed (부영양상태 호수유역의 강우유출수에 의한 초기세척효과 분석)

  • Cho, Jae-Heon;Seo, Hyung-Jun
    • Journal of Environmental Impact Assessment
    • /
    • v.16 no.5
    • /
    • pp.341-350
    • /
    • 2007
  • Lake Youngrang is a lagoon whose effluent flows into the East Sea. Because two resort towns and two golf courses are situated at the lake basin, many tourists visit this area. Stormwater runoff surveys were carried out for the eight storm events from 2004 to 2005 in the eutrophic lake watershed to give a basic data for the diffuse pollution control of the lake. Dimensionless mass-volume curves indicating the distribution of pollutant mass vs. volume were used to analyze the first flush phenomenon. The mass-volume curves were fitted with a power function and polynomial equation curves. The regression analysis showed that the polynomial equation curves were better than the power function in representing the tendency of the first flush, and second degree polynomial equation curves indicated the strength of the first flush effectively.

Effectiveness of Settling Treatment System to Reduce Urban Nonpoint Source Pollutant Load by First Flush (초기 강우에 의한 도시 유역 비점오염 부하의 유입 저감을 위한 침강 처리 시설 적용 타당성 분석)

  • Kim, Jaeyoung;Seo, Dongil;Lee, Tongeun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.39 no.3
    • /
    • pp.140-148
    • /
    • 2017
  • The effectiveness of the first flush treatment system using settling process was evaluated to reduce urban nonpoint source pollutant loads to surface water during storm events. A pilot scale system was constructed and tested in the field and surface runoff samples were collected automatically according to pre-defined conditions. Nine rainfall events were tested and average removal efficiencies of TSS (Total Suspended Solid), TP (Total Phosphorus) and TN (Total Nitrogen) were evaluated as 87.4%, 75.3%, and 43.6%, respectively. Concentration and removal efficiency of pollutants were found to be affected by an amount of rainfall and rainfall intensities of the respective events. This seemed to be caused by the greater particulate fractions of first flushed samples than the samples collected in later time periods during the same rainfall events. The study showed that it is possible to remove a significant portion of the nonpoint source pollutant loads in initial rainfall runoff by using a simple settling process for TSS and TP without requiring additional power or chemicals.

Freezing and Washing of Red Blood Cells Using Haemonetics ACP 215 (Haemonetics ACP 215를 이용한 적혈구의 동결과 세척)

  • Youn, Kyoung Won;Choi, Kyoung Young;Lee, Sun Ah;Min, Hyuk Ki;Kim, Jaehyun
    • The Korean Journal of Blood Transfusion
    • /
    • v.29 no.3
    • /
    • pp.291-300
    • /
    • 2018
  • Background: The use of a functionally closed system for the glycerolization and deglycerolization of red blood cells (RBCs) allows for prolonged post-thaw storage for more than 24 hours. The aim of this study was to assess glycerolization and deglycerolization processing for RBCs using a high glycerol method in the automated, closed system provided by Haemonetics ACP 215. Methods: Thirty-five packed RBCs were glycerolized using the ACP 215 to a final concentration of 40% (wt/vol). The units were either frozen as such (n=30) or excess glycerol was removed (n=5) before freezing. After storage at $-80^{\circ}C$, the units were thawed, deglycerolized and resuspended in SAG-M. The frozen-thawed RBCs were stored at $4^{\circ}C$, and analyzed for their stability and in vitro quality. Results: No prefreeze excess glycerol removal units showed significantly less potassium leakage during post-thaw storage compared to the prefreeze excess glycerol removal units. All measurements of the stability and in vitro quality of thawed RBCs prepared from frozen RBCs without the prefreeze removal of excess glycerol during post-thaw storage at $4^{\circ}C$ for 7 days were acceptable to the American Blood Bank Association's standards and European standards. Conclusion: RBCs frozen without prefreeze removal of excess glycerol and the ACP 215 simplifies cryopreservation procedure and increases the stability of frozen-thawed RBCs. This increases the practical applicability of cryopreserved RBCs in blood transfusion practice.

A Study on Characteristics of Nonpoint Pollution using Initial Overflows of Urban Stream (도시하천의 초기월류수를 이용한 비점오염특성 연구)

  • Kang, Yong-Tae;Han, Sang-Yun;Cho, Yong-Hyun;Song, Kuen-Kwan;Jeon, Jong-Gyu
    • Proceedings of the KAIS Fall Conference
    • /
    • 2007.05a
    • /
    • pp.116-118
    • /
    • 2007
  • 비강우시와 강우시 학장천의 수질은 BOD, COD, T-N, T-P, SS에 대해 각각 $11.0{\sim}31.3mg/L$, $15.6{\sim}31.4mg/L$, $5.762{\sim}15.937mg/L$, $0.918{\sim}1.291mg/L$, $18.1{\sim}31.41mg/L$$27.2{\sim}65.11mg/L$, $32.1{\sim}73.2rng/L$, $13.409{\sim}18.051mg/L$, $1.263{\sim}2.282mg/L$, $66.0{\sim}417.9mg/L$로 나타나 학장천은 전형적인 생활하수의 특성을 지녔으며, 강우시 발생되는 초기월류수에 다량의 비점오염물질이 포함됨을 알 수 있었다. 강우시 발생된 월류수의 유량을 측정한 결과 학장천의 유출계수는 $0.61{\sim}0.83$의 범위였고, 초기세척효과는 SS>T-N>COD>BOD>T-P>1 의 순서로 그 정도가 크게 나타났다. 학장천 초기월류수의 유량가중평균농도를 산정한 결과 대부분의 항목에서 청천시의 수질농도보다 높게 나타나 강우에 의한 월류수의 비점오염물질의 유출이 심각함을 알 수 있다.

  • PDF

Removal of Heavy Metal and Organic Substance in Contaminated Soils by Electrokinetic and Ultrasonic Remediation (동전기 및 초음파 복원기술에 의한 오염지반내의 중금속 및 유기오염물질 제거)

  • Chung, Ha-Ik
    • Journal of the Korean Geotechnical Society
    • /
    • v.19 no.3
    • /
    • pp.83-91
    • /
    • 2003
  • The electrokinetic technique has been applied to remove mainly the heavy metal and the ultrasonic technique to remove mainly organic substance in contaminated soil. In this study, the combined electrokinetic and ultrasonic remediation technique was studied far the removal of heavy metal and organic substance in contaminated soils. This study emphasized the coupled effects of electrokinetic and ultrasonic techniques on migration as well as remediation of contaminants in soils. The laboratory soil flushing tests combining electrokinetic and ultrasonic technique were conducted using specially designed and fabricated devices to determine the effect of both of these techniques. A series of laboratory experiments involving the simple, electrokinetic, ultrasonic, and electrokinetic & ultrasonic flushing test were carried out. A soil admixed with sand and kaolin was used as a test specimen, and Pb and ethylene glycol were used as contaminants of heavy metal and organic substance. An increase in out flow, permeability and contaminant removal rate was observed in electrokinetic and ultrasonic flushing tests. Some practical implications of these results are discussed in terms of technical feasibility of in situ implementation of electrokinetic ultrasonic remediation technique.

Study on the characteristics of nonpoint source runoff at livestock manure treatment plants (가축분뇨처리시설의 비점오염원 유출특성에 관한 연구)

  • Cho, Sung Jin;Rhee, Han Pil
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2016.05a
    • /
    • pp.566-566
    • /
    • 2016
  • 정부의 4대강 물 관리 종합대책에 따르면, 수계 전체 오염원중 비점오염원이 차지하는 오염부하가 22~37%에 달하는 것으로 추정되고 있다. 하지만 이러한 중요성에도 불구하고 농업지역 비점오염물질 저감을 위한 대책은 논과 밭과 같이 농경지에 관한 것이 대부분이었으며, 축산은 관리 기준의 가장 기초라고 할 수 있는 지목분류기준에 조차 별도의 기준이 없는 실정이다. 가축분뇨공공처리시설과 가축분뇨자원화시설은 가축분뇨를 처리하여야 하는 점오염원이지만, 차량 운반시 발생되는 일부 분뇨와 처리장 세척 시 발생되는 일부 오염물질들이 비점오염원으로 작용하고 있으며 이에 대한 관리가 미흡한 실정이다. 따라서 본 연구에서는 가축분뇨공공처리시설과 가축분뇨자원화시설에서 강우시 발생되는 유출특성을 분석하였으며, 이를 통해 가축분뇨처리시설의 비점오염 관리 처리시설 설치 시에 중요한 기초자료로 활용하고자 한다. 본 연구에서는 경상북도 영천시, 경기도 용인시, 전라북도 정읍시, 강원도 횡성군 등 축산밀집 지역을 대상으로 연 5회 강우시 모니터링을 실시하였으며, 모니터링자료를 바탕으로 유량가중평균농도(Event Mean Concentration, EMC)를 산정하였다. 영천시 가축분뇨자원화시설의EMC 산정결과 평균 BOD 5.1 mg/L, TN 6.90 mg/L, TP 0.91 mg/L로 산정되었으며, 용인시 개별처리농가의 경우 BOD 6.8 mg/L, TN 3.74 mg/L, TP 1.04 mg/L로, 횡성군 가축분뇨공공처리장의 경우 BOD 4.5 mg/L, TN 3.56 mg/L, TP 1.60 mg/L로, 정읍시 가축분뇨공공자원화시설의 경우 BOD 4.3 mg/L, TN 6.82 mg/L, TP 0.48 mg/L로 산정되었다. BOD, TN은 영천시 가축분뇨자원화시설에서 가장 높게 나타났고, TP의 경우 횡성군 축산폐수공공처리장의 경우 높게 나타났다. 유출특성을 분석한 결과 가축분뇨자원화시설의 경우 대부분 콘크리트 기반으로 조성된 토지위에 조성되어 강우시 유량은 급격하게 상승하며, 강우가 종료되면 바로 감소하는 불투수층 지역의 특성을 나타났다. 본 연구에서 분석된 유츨특성과 EMC는 비점오염 처리시설이나 가축분뇨공공처리시설 설치시 기초데이터로 활용이 가능할 것으로 판단되며, 향후 가축분뇨처리시설의 지속적인 모니터링과 모니터링지점 확대로 자원화시설 강우유출수의 DataBase화를 통한 지속적인 연구 및 관리가 되어야 할 것으로 판단된다.

  • PDF

Set up Reduction Goals of Combined Sewer Overflow Pollutant Load Using Long-Term Rainfall-Runoff Model Simulation (장기간 강우-유출 모의를 통한 합류식하수관로시스템의 월류부하량 저감목표 설정 연구)

  • Lee, Gunyoung;Na, Yongun;Ryu, Jaena;Oh, Jeill
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.35 no.11
    • /
    • pp.785-794
    • /
    • 2013
  • Combined sewer overflows during rainfall events contain sewer sediments and surface pollutants. This can cause significant chemical, physical and biological problems to receiving watershed. However, there are no method that can commonly apply to decide criteria for controlling the pollutant load. In this study, it sets up the reduction goals of combined sewer overflow through long-term simulation using the rainfall-runoff model. From a review of domestic and foreign management standard of combined sewer overflow for this, it makes decision that 60% (phase 1), 85% (phase 2) of total pollutant load and frequency per year for reduction goals is more proper. Also, the result of analyzing long-term simulation (minimum 10 years) applied to research basin indicates that reduction goals of BOD pollutant load are 1,123 kg (phase 1) and 2,374 kg (phase 2), and overflow volumes for research objective achievement are $11,685m^3$ (phase 1) and $24,701m^3$ (phase 2).

Characteristics of Collected Sediments from Road Sweeping and Reduction in the Nonpoint Source Pollutants Loading (도로청소 수거퇴적물의 특성과 비점오염물질 저감효과)

  • Jeong, Kwon;Kang, Hee-Man;Ko, Seok-Oh
    • International Journal of Highway Engineering
    • /
    • v.13 no.2
    • /
    • pp.187-193
    • /
    • 2011
  • The stormwater runoff from road or expressway is known as one of important nonpoint pollution sources. To reduce the pollutants discharge from road or expressway, many best management practices(BMPs) have been applied and planned. Among the BMPs, road sweeping can be effective way to prevent pollutant washoff to environment. This study is performed to evaluate the characteristics of particles collected from the road by sweeping car. Size distribution and pollutant concentration of particles were analyzed. Based on the pollutant concentration and the specification of road such as length, width, and unit for pollutant generation, total amount of pollutant to be removed by road sweeping was estimated. Most of sediments collected by road sweeping was classified into sandy soil and fraction of fine grained soil was low. Although the concentrations of pollutants such as heavy metals in road sediments did not exceed the soil contamination criteria, washout of pollutants during sweeping work by spraying water might cause leaching of pollutants contained in sediments and thus resulted in low pollutant concentrations. Reduced amounts of pollutant by road sweeping showed 31.4% TSS reduction for ${\bigcirc}{\bigcirc}$ region and 7.7% TSS for ${\triangle}{\triangle}$ region. Other pollutants showed low reduction rate, because of their leaching by water spraying. Results from this study indicate that detailed and well-planned investigation for the road sweeping is necessary for the accurate estimation of pollutant reduction from road or expressway.

Life-threatening Airway Edema after Arthroscopic Repair of Massive Rotator Cuff Tear - A Case Report - (관절경하 광범위 회전근 개 파열 수술 후 발생한 치명적인 기도 부종 - 증례 보고 -)

  • Moon, Young-Lae;Yu, Byung-Sik;So, Keum-Young;Lim, Kyung-Joon;Kang, Jeong-Hoon
    • Clinics in Shoulder and Elbow
    • /
    • v.10 no.1
    • /
    • pp.136-139
    • /
    • 2007
  • Shoulder arthroscopic surgeries are an accepted technique for many shoulder disease and have many advantages over open surgeries. To date, shoulder arthroscopic surgery have been rare complications that compromise patient airway, caused by the leakage of irrigation fluid out of the shoulder joint space into the surrounding soft tissues and then the neck and the pharynx. This report presents a case of life-threatening airway obstruction due to extra-articular saline collection during arthroscopic rotator cuff repair. In concluding we should hourly check the patient's neck swelling undergoing shoulder arthroscopic surgery, because anesthetized patients cannot complain of the airway problem may progress until it becomes life-threatening.