• Title/Summary/Keyword: 성형효과

Search Result 614, Processing Time 0.033 seconds

The Effect of Injection of Steroid and 5-Fluorouracil on Hypertrophic Scars of Rabbit (가토의 비후성 반흔에서 스테로이드와 5-플루오르우라실 투여 효과)

  • Kim, Kyung-Rak;Ryu, Sun-Youl
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.33 no.3
    • /
    • pp.210-217
    • /
    • 2011
  • Purpose: This study was to evaluate the synergistic effects of combined therapy of steroid and anti-neoplastic drug injection on hypertrophic scars in a rabbit model. Methods: Adult male white rabbits weighing about 2.5 kg were used. After full thickness wounding (about 6 mm) over the ventral surface of each ear sized was made, either saline (control group), triamcinolone, 5-fluoruracil, and mixture of triamcinolone and 5-fluoruracil were injected once 16 days after the wound was made. Rabbits were sacrificed 2, 4 and 8 weeks after injection, and tissue specimens were prepared for histologic and histomorphometric examinations. Results: With the combined injection of triamcinolone and 5-fluoruracil, collagen fiber thickness was arranged in a somewhat irregular manner 2 weeks after injection. After 4 weeks, blood vessels and inflammatory cells were decreased, and collagen fibers were arranged in an almost parallel manner. By 8 weeks, almost same amount of connective tissue compared with adjacent normal tissue was observed. Conclusion: These results indicated that combined injection of triamcinolone and 5-fluoruracil reduced the amount of hypertrophic scars by inhibition of fibroblasts and inflammatory cells. Therefore, combined injection of triamcinolone and 5-fluoruracil is a more potent and effective treatment of hypertrophic scars compared with the single injection of either triamcinolone or 5-fluorouracil.

AN EFFECT OF COMBINATION WITH ARTHROCENTESIS AND STABILIZATION SPLINT TREATMENT OF TEMPORPMANDIBULAR JOINT DISORDER PATIENT (측두하악장애 환자에서 악관절 세정술과 교합안정장치를 동반한 치료의 효과)

  • Park, Yong-Hee;Lee, Sang-Hwa;Yoon, Hyun-Joong
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.32 no.1
    • /
    • pp.32-36
    • /
    • 2010
  • The purpose of this study was to evaluate the clinical outcomes of patients with temporomandibular joint disorder before and after performance of arthrocentesis and stabilization splint therapy. The subjects of this study were 33 patients with limited mouth opening or pain or joint effusion who visited the Department of Oral and Maxillofacial Surgery, St Mary's Hospital, Catholic University of Korea. The arthrocentesis was performed and the stabilization splint was worn immediately after the arthrocentesis. Comparing the clinical outcomes of treatment at the times of first medical examination, 3 months and 6 months later on treatment. The results are as follows; 1. Statistically significant increase in the amount of maximum mouth opening occurred 3 months and 6 months later on treatment. 2. Statistically significant decrease in the average value of pain on test measured by VAS during maximum mouth opening, protrusive movement, right lateral movement, left lateral movement occured 3 months and 6 months later on treatment. The results suggested that arthrocentesis and stabilization splint therapy provide a improvement on patients with temporomandibular joint disorder when the exact diagnosis were provided.

Czochralski crystal growth by the accelerated crystal rotation technique (결정봉 회전 가속화 기법에 의한 초크랄스키 결정 성장)

  • 김승태;최정일;성형진
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.8 no.1
    • /
    • pp.18-28
    • /
    • 1998
  • A laboratory experiment was made of a control of temperature oscillation in Czochralski convection. Numerical computation was also made to delineate the control of temperature oscillation. The suppression of temperature oscillation was achieved by varying the rotation rate of crystal rod ($\Omega=\Omega_0(1+A sin 2{\pi}ft/t_p)$), where A denotes the amplitude of rotation rate and f the frequency factor. Based on the inherent dimesionless time period of temperature oscillation ($t_p$), the suppression rate of temperature oscillation was characterized by the mixed convection parameter ($0.217{\leq}Ra/PrRe^2{\leq}1.658$). The optimal values of A and f were also scrutinized. To understand the suppression mechanism of temperature oscillation, the controls of isotherm($\theta$) and equi-vorticity($\omega$) were investigated.

  • PDF

Study of Micro-channel Filling Flow Including Surface Tension Effects (표면 장력 효과를 고려한 마이크로 채널 충전과정 연구)

  • Kim, Dong-Sung;Lee, Kwang-Cheol;Kwon, Tai-Hun;Lee, Seung-S.
    • Proceedings of the KSME Conference
    • /
    • 2001.06c
    • /
    • pp.47-52
    • /
    • 2001
  • Micro-injection molding and microfluidic devices with the help of MEMS technologies including the LIGA process are expected to play important roles in. micro-system industries, in particular the bioapplication industry, in the near future. Understanding fluid flows in micro-channels is important since micro-channels are typical geometry in various microfluidic devices and mold inserts for micro-injection molding. In the present study, both experimental and numerical studies have been carried out to understand the detailed flow phenomena in micro-channel filling process. Three sets of micro-channels of different thickness were fabricated and a flow visualization system was also developed to observe the filling flow into the micro-channels. Experimental flow observations were extensively made to find the effects of channel width and thickness, and effects of surface tension and volume flow rate and so on. And a numerical analysis system has been developed to simulate the filling flow into micro-channels with the surface tension effect taken into account. Discussed are the flow visualization experimental observations along with the predictability of the numerical analysis system.

  • PDF

Experimental Study for the Efficacy of Suprahyoid Release Technique in Dogs (설골상부 근육이완술이 기관성형에 미치는 효과 (실험적 연구))

  • 김경우
    • Journal of Chest Surgery
    • /
    • v.15 no.2
    • /
    • pp.139-147
    • /
    • 1982
  • In case of segmental injury of trachea, the primary repair is very difficult, because the trachea is fixed in place without movability from the surrounding tissue. In addition to special anatomical situation of trachea, any ideal artificial prosthesis for tracheal replacement is not still appeared. Many authors proposed several procedures for the tracheal repair, but satisfactory results were few. Among the proposed procedures end to end anastomosis of trachea was noted superior when both ends of trachea could be approximated by mobilization of upper and lower injured trachea. The author's experiment was designed to determine the effect about decreased tension on trachea when the hyoid bone was released downward from the surrounding muscular structures. The experimental dogs were divided into two groups, suprahyoid releasing group (SH R) and control group of intact hyoid. SH R group was subdivided into two groups accord ing to he degree of tension. The experimental results were as follow; 1. SH R group: In view of X-ray, the distance between the angle of mandible and the displaced hyoid bone was lengthened downward. And it's range was from 1.3cm (38%) minimally to 2.7cm(108%) maximally. 2. Control group: The distance between the angle of mandible and hyoid was same in both pre and postoperation. As the result of this experiment study, the suprahyoid release technique seems to be the efficient method that enable of release the trachea maximally. And it should be expected that the SH R technique is applicable clinically.

  • PDF

Evaluation of Effective Cartilage Reshaping using Nd:YAG laser (${\lambda}$ = 1444 nm) (Nd:YAG 레이저(${\lambda}$ = 1444 nm)를 이용한 연골 재성형 효과 규명)

  • Yoon, Jin-Hee;Youn, Jong-In
    • Journal of Biomedical Engineering Research
    • /
    • v.31 no.6
    • /
    • pp.472-480
    • /
    • 2010
  • Mechanically deformed cartilage undergoes a temperature dependent phase transformation resulting in reshaping of cartilage. Laser-assisted cartilage reshaping (LCR) is recently introduced to recreate the underlying cartilage framework in structures such as ear, larynx, trachea, and nose. However, this procedure has not been fully supported by confirmed efficacy because of the lack of scientific research and its safety issues. The purpose of this study is to evaluate current laser sources to determine optimal laser wavelength for LCR using mathematical simulations and investigate optical, thermo-mechanical, and backscattering properties of cartilage after laser irradiation. The results showed that 1444 nm wavelength was effective for reshaping of cartilage with minimal thermal damage in the surrounded tissues by monte carlo simulations. Analysis of bend angle changes, thermo-mechanical characteristics, and backscattered properties may be useful to better identify the biophysical transformation responsible for stress relaxation in cartilage and develop an optical feedback control methodologies.

FMS의 현상과 장래 동향

  • Lee, Dong-Ui
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.1 no.2
    • /
    • pp.9-25
    • /
    • 1984
  • 중품종, 중량생산용의 합리적인 생산 system의 일형태로서 미국 Kearney & Trecker 사가 실용하고 있는 Flexible Manufacturing System(약칭 F.M.S.)을 처음으로 발표한 것은 1960 년대 후반이었다. 그러나 이 FMS도 그 후 얼마동안은 선전마저도 되는일 없이 지내왔다. 그런데 사회의 발전과 더불어 사회의 제품에 대한 요구가 다양화, 단수명화의 방향으로 진보되어, 그 결과, FMS의 중요성이 인식되게 되었다. 그리고 1970 년대후반부터 라고 표현될만한 상황이 일본,미국,서독 등 3개국을 중심으로 표현했다. 당초에는 라고 하는 용어만이 선행한 바람 직하지 못한 점은 있었으나 그후 FMS의 본질을 이해한 System의 도입증가와 함께 FMS 기술도 상당히 발전되어 왔다. 또한 FMS의 가동예의 증가와 더불어 그 도입효과가 눈부시다는 것이 분명해졌다. 이 FMS의 중요성은 , 혹은 라고 하는 말로 집약되는데 당연히 현재로서는 FMS는 공업선진국, 개발 도상국을 막론하고 큰 화제를 불러 일으키고 있다. 따라서 이와같은 중요한 FMS의 상황을 국제적인 관점에서 정확히 파악한다는 것은 매우 중요한 일이다. 그러나 현금에 있어서의 FMS기술의 급속한 진보는 이와같은 관점에서의 상황파악을 매우 어렵게 하고 있다. 이제까지도 예컨데 Scharf와 Schulz, Hutchinson, Spur와 Mertinz 혹은 기계기술협회생산기술조사분과회(일본)의 조사예가 있으나, 상세한 것은 각국별, 혹은 각사별의 해설을 참조하지 않으면 이해할 수 없다. 더우기 이제까지는 기계가공용 FMS가 주체였으나 현대에 이르러서는 FMS의 적용범위는 판금가공, 단조가공, Plastic사출성형가공, 조립 등에 널리 이용되어 왔기때문에 점점 그 현상의 파악이 어려워지고 있다. 따라서, 여기서는 그와같은 FMS의 현상과 장래의 발전동향을 간단히 이해할 수 있도록 개설하고자 한다.

  • PDF

Development of Cam Die for Processing Four Lateral Switch Box (스위치 박스 4측면 가공용 캠금형 개발)

  • 김세환
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.4 no.3
    • /
    • pp.121-125
    • /
    • 2003
  • A switch box is metal box for electric wire pipes in building. In manufacturing this box, the first press is used to mold and the second to fifth presses are used to process four-sides of a box. So four presses, four molds and four workers are needed. This leads to raise the manufacturing cost including machine lease rent, molding fee, and wages. To make matters worse, the roaring sound, vibration, and dangers of safety accidents make employees avoid from working that job. To solve this problem, a new Handling Mechanism and a cam die which combined four-die-involving processes into one die process were developed. That results job automation of the Job with one press and one die. The job avoidance problem is solved and manufacturing cost is reduced as well.

  • PDF

A Comparative Study of the Effect of External Ultrasound with Power Assisted Liposuction(PAL) (Power Assisted Liposuction(PAL)과 병용한 외부 초음파의 효과에 대한 비교 연구)

  • Song, In Soo;Park, Jun;Yoo, Young Cheun;Yang, Won Yong;Kim, Jin Young
    • Archives of Plastic Surgery
    • /
    • v.32 no.4
    • /
    • pp.496-502
    • /
    • 2005
  • This study was performed to compare the effect of external ultrasound assisted PAL(power assisted liposuction) with that of PAL alone. We performed 17 cases of liposuction from January 2003 to June 2003. For comparing both systems, we treated the right side(study group) with external ultrasound assisted PAL and the left side(control group) with PAL alone. To evaluate the difference in results between two groups, we surveyed three objective and four subjective items. Objectives were categorized as "Reduction rate of postoperative swelling", "Efficiency of suction" and "Histologic finding of aspirated fat tissue". Subjectives were also filed as "Degree of postoperative bruising", "Cannula resistance that operator felt", "Degree of postoperative pain" and "Patient's satisfaction". We assessed by questionnaire three times at 1day, 7 days and 30 days after operation. There were statistically significant differences in two of the subjective items; "Degree of postoperative pain at postoperative 1 day" and "Cannula resistance that operator felt". This study concludes that external ultrasound PAL is more effective high mobility of fat tissue and low tension of surrounding tissue. External ultrasound PAL will be more useful in case of large volume liposuction and revision procedures.

Effects of Particle Size and Binder Phase Addition on Formability of Li-Si Alloy Powder for Thermal Battery Anode (열전지 음극재용 Li-Si 원료의 성형성에 미치는 입자크기와 바인더첨가 효과)

  • Ryu, Sung-Soo;Kim, Hui-Sik;Kim, Seongwon;Kim, Hyung-Tae;Cheong, Hae-Won;Lee, Sung-Min
    • Journal of Powder Materials
    • /
    • v.21 no.5
    • /
    • pp.331-337
    • /
    • 2014
  • The effects of particle size of Li-Si alloy and LiCl-KCl addition as a binder phase for raw material of anode were investigated on the formability of the thermal battery anode. The formability was evaluated with respect to filling density, tap density, compaction density, spring-back and compressive strength. With increasing particle size of Li-Si alloy powder, densities increased while spring-back and compressive strength decreased. Since the small spring-back is beneficial to avoiding breakage of pressed compacts, larger particles might be more suitable for anode forming. The increasing amount of LiCl-KCl binder phase contributed to reducing spring-back, improving the formability of anode powder too. The control of particle size also seems to be helpful to get double pressed pellets, which consisted of two layer of anode and electrolyte.