• Title/Summary/Keyword: 성인남성

Search Result 727, Processing Time 0.174 seconds

Serum 25-Hydroxy Vitamin $D_3$ Analysis of Korean People (한국인 일반인의 혈청 25-Hydroxy Vitamin $D_3$의 분석)

  • Kim, Bo-Kyung;Jung, Hyun-Mi;Kim, Yun-Kyung;Kim, So-Young;Kim, Jee-Hyun
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.1
    • /
    • pp.133-137
    • /
    • 2010
  • Purpose: The main function of vitamin D is the mineralization of the brain by increase of calcium and phosphorus, in case it is insufficient in children, lime deposition on cartilage cannot occur so it leads to rachitis, and in adults, it leads to osteomalacia or osteoporosis. It is also strongly believed in the academic world that vitamin D can restrict the growth of cancer cells and prevent heart diseases, which is also somewhat proven in epidemiological researches. While the right density of vitamin D is still being studied, 20-32 ng/mL is believed to be the most ideal density. Therefore, I wanted analyze how much density of 25-Hydroxyvitamin D3 that Koreans possess. Materials and Methods: From February 20th, 2008 to April 21st, 2009, the collection of 2800 serums, from medical examination treated subjects by Neodin Medical Institute, have been tested. The targets were tested by 25-Hydroxyvitamin D (125I Kit: Diasorin, USA), and were analyzed by dividing into many different categories (gender, age, season, region). Results: The average density of male were 20 ng/mL, female 17.08 ng/mL. Per age groups, the density of males were as follows: 10~20-18 ng/mL, 21~30-17 ng/mL, 31~40-19 ng/mL, 41~50-21 ng/mL, 51~60-22 ng/mL, 61~70-22 ng/mL, 71~80-22 ng/mL and 81~90-19.9 ng/mL. Average density of females per age groups, were as follows: 10~20-16 ng/mL, 20~30-15.26 ng/mL, 30~40-16 ng/mL, 40~50-17 ng/mL, 50~60-19 ng/mL, 60~70-19 ng/mL, 70~80-19 ng/mL, and 80~90-17 ng/mL. Per seasons, From December to May, the subjects showed the density of 15.97 ng/mL, while from June to November, it showed 21.60 ng/mL. On density of males from January to April regionally, Seoul+Gyeonggi-Do-15.52 ng/mL, Gangwon-Do-15.33 ng/mL, Choongchung-Do-18.03 ng/mL, Jeonla-Do-18.68 ng/mL, Gyungsang-Do-18.76 ng/mL and Cheju Do-21.23 ng/mL. Conclusions: The vitamin D of Koreans is has been insufficient compared to the suggested amount. Ultraviolet rays, which is the main source of vitamin D is critical, therefore it is suggested that more outdoor activities can definitely help.

  • PDF

Comparative analysis of Glomerular Filtration Rate measurement and estimated glomerular filtration rate using 99mTc-DTPA in kidney transplant donors. (신장이식 공여자에서 99mTc-DTPA를 이용한 Glomerular Filtration Rate 측정과 추정사구체여과율의 비교분석)

  • Cheon, Jun Hong;Yoo, Nam Ho;Lee, Sun Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.25 no.2
    • /
    • pp.35-40
    • /
    • 2021
  • Purpose Glomerular filtration rate(GFR) is an important indicator for the diagnosis, treatment, and follow-up of kidney disease and is also used by healthy individuals for drug use and evaluating kidney function in donors. The gold standard method of the GFR test is to measure by continuously injecting the inulin which is extrinsic marker, but it takes a long time and the test method is complicated. so, the method of measuring the serum concentration of creatinine is used. Estimated glomerular filtration rate (eGFR) is used instead. However, creatinine is known to be affected by age, gender, muscle mass, etc. eGFR formulas that are currently used include the Cockroft-Gault formula, the modification of diet in renal disease (MDRD) formula, and the chronic kidney disease epidemilogy collaboration (CKD-EPI) formula for adults. For children, the Schwartz formula is used. Measurement of GFR using 51Cr-EDTA (diethylenetriamine tetraacetic acid), 99mTc-DTPA (diethylenetriamine pentaacetic acid) can replace inulin and is currently in use. Therefore, We compared the GFR measured using 99mTc-DTPA with the eGFR using CKD-EPI formula. Materials and Methods For 200 kidney transplant donors who visited Asan medical center.(96 males, 104 females, 47.3 years ± 12.7 years old) GFR was measured using plasma(Two-plasma-sample-method, TPSM) obtained by intravenous administration of 99mTc-DTPA(0.5mCi, 18.5 MBq). eGFR was derived using CKD-EPI formula based on serum creatinine concentration. Results GFR average measured using 99mTc-DTPA for 200 kidney transplant donors is 97.27±19.46(ml/min/1.73m2), and the eGFR average value using the CKD-EPI formula is 96.84±17.74(ml/min/1.73m2), The concentration of serum creatinine is 0.84±0.39(mg/dL). Regression formula of 99mTc-DTPA GFR for serum creatinine-based eGFR was Y = 0.5073X + 48.186, and the correlation coefficient was 0.698 (P<0.01). Difference (%) was 1.52±18.28. Conclusion The correlation coefficient between the 99mTc-DTPA and the eGFR derived on serum creatinine concentration was confirmed to be moderate. This is estimated that eGFR is affected by external factors such as age, gender, and muscle mass and use of formulas made for kidney disease patients. By using 99mTc-DTPA, we can provide reliable GFR results, which is used for diagnosis, treatment and observation of kidney disease, and kidney evaluation of kidney transplant patients.

Changes in Accommodative Function of Young Adults in their Twenties following Smartphone Use (스마트폰 사용에 따른 20대 성인의 조절기능 변화)

  • Park, Mijung;Ahn, Young Joo;Kim, Soo Jung;You, Jiyoung;Park, Kyung Eun;Kim, So Ra
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.2
    • /
    • pp.253-260
    • /
    • 2014
  • Purpose: The present study was conducted to investigate whether near work with smartphone could induce the change of accommodative function. Methods: Total 63 subjects(26 male and 37 female) in their 20s were firstly examined their visual functions related to accommodation and uncorrected spherical equivalent power as the control. After that, the subjects were asked to read a book for 30 min and sequentially watch a movie on smartphone for the same time after 30 min-break under the indoor light or as it was in the reverse order to avoid time-ordered effect. Their accommodative functions, 1) accommodative amplitude, 2) accommodative facility, 3) relative positive/negative accommodation, and 4) accommodative lag and their uncorrected spherical equivalent power were examined again following each task and compared with the control values. Results: The monocular accommodative amplitude was significantly decreased after smartphone watching compared with it after reading. The monocular and binocular accommodative facilities were tended to reduce after smartphone watching and book reading but were not significantly different. Neither significant change in positive relative accommodation was determined after smartphone watching nor book reading. Negative relative accommodation after smartphone watching was almost unchanged unlike reading a book. The accommodative lag after smartphone work was significantly higher than after book reading. Conclusions: The near work with a smartphone for 30 min induced the change of some accommodative functions, which was significantly greater than when reading under the same working environment.

The Clinical Examination of Netspeg Lens for Good Visual Acuity (시력 개선을 위한 Netspeg 렌즈의 임상적 검증)

  • Kim, Douk-Hoon;Bae, Han-Young;Kim, Sun-Tae
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.11 no.3
    • /
    • pp.281-291
    • /
    • 2006
  • The aim of this study was performed the clinical test using Netspeg lens for good visual acuity on subjects with abnormal refraction status. The subjects of one hundreds adults (fifty males, fifty females, mean=21 years, range=19 to 24) were recorded. The subjects were researched the history including the systemic health, medication, genetics, allergy, systemic disease and ocular disease. The refraction test was recorded the monocular and binocular using objective method. Visual acuity was performed the binocular status using the Netspeg lens and CR-39. Stereopsis test was performed the titmus fly and TNO at near distance using Netspeg lens and CR-39. The P-VEP test was used the 16 pattern size(Bausch Lomb, production in USA) with three channels. Also Subjects viewed the p-vep stimulus with binocular vision through the corrected visual acuity using the Netspeg lens and CR-39. The contrast sensitivity test was performed the contrast sensitivity chart(pelli-Robertson, USA) at 1m distance using the Netspeg lens and CR-39. The ultrastructure of surface on the Netspeg lens and CR-39 was observed the SEM(JMS-5800, made in Japan). The results of this study was as follows: 1. In corrected visual acuity of abnormal refraction using the Netspeg lens and CR-39, the Netspeg lens wearer were acquired the good visual field and clear visual acuity comparative to CR-39 wearer in the subject vision test. however the comfort of visual acuity was similar results in the Netspeg lens and CR-39. Also the subjects of Netspeg lens wearer was good visual acuity more than CR-39 wearer and in the analysis of P-VEP, the amplitude of wave on Netspeg lens used appears to be better through the CR-39(p>0.5). Besides, on the contrast sensitivity, the Netspeg lens wearer was good results than CR-39. The value on stereopsis with TNO by Netspeg lens wearer was better than CR-39 in results. However, in the stereopsis test with Titmus, the Netspeg lens and CR-39 wearer was similar results. 2. The ultrastructure of Netspeg lens surface was the smooth and fine shape more than CR-39. Also, Netspeg lens have a fine line structure in ultrastructure. In conclusion, the results of this study conformed that the surface ultrastructure of Netspeg lens used is more specific pin hole design structure than CR-39. This study indicated that the vision of Netspeg lens used have a better than CR-39 in the corrected visual acuity for abnormal refraction eye. Therefore, In this paper, we suggested that the ultrastructure and line structure of Netspeg lens was related to good visual function. However the visual function of the aspheric Netspeg and ultra waterproof Netspeg lens was similar results.

  • PDF

Management Strategy of Indoor Hazardous Chemicals (실내.외 통합 모델링 및 인체 위해성 평가를 통한 실내 유해화학물질의 관리 전략)

  • Shin, Yong-Seung;Lim, Hye-Sook
    • Journal of Environmental Policy
    • /
    • v.7 no.2
    • /
    • pp.67-90
    • /
    • 2008
  • The purpose of this study is to develop indoor air quality management strategies regarding indoor air pollutants while considering various factors affecting indoor pollutants concentration. The Integrated Indoor Air Quality model(IIAQ) developed by Seoul National University is used for this study. The IIAQ model is a tool that can provide an integrated view to indoor environmental pollution by simulating suggested scenarios. The results of the modeling are used to assess health risk. The concentrations that are used for the risk characterization are weighted concentrations based on the period of time in each place and existing Indoor Air Quality(IAQ) standards. The estimated concentration of toluene and formaldehyde for 10 years through the IIAQ model was 207.3 $ug/m^3$ and 36.4 $ug/m^3$ in indoors, and 55.9 $ug/m^3$ and 8.62 $ug/m^3$ in outdoors. These concentrations are lower than the existing IAQ standards. The estimated carcinogenic risk of formaldehyde is up to 1.05E-03 for the adult male group and exceeds 1E-06 for all receptor groups. This value means that cancer could affect one person out of 1000. The estimated non-carcinogenic risk of toluene was lower than 1, which means that there was no serious non- carcinogenic risk. The result of modeling shows that using low emitting indoor sources is the most effective strategy for both formaldehyde and toluene. This risk assessment suggests that the total exposure levels of existing IAQ standards may cause serious carcinogenic risk. In order to avoid uncontrolled risk, it is suggested that the current IAQ standards should be adjusted by taking into account the total amount of exposure from all exposure pathways from indoor and outdoor sources.

  • PDF

Nutritional and Microbiol Quality Assessment of Chungmukimbab (충무김밥의 영양적 및 미생물적 품질 평가)

  • Choi Jong-Duck;Hwang Young-Suk;Jeoung In-Geon;Lee Da-Jeong;Park Phil-Sook;Park Mi-Yeon
    • Journal of Food Hygiene and Safety
    • /
    • v.21 no.3
    • /
    • pp.189-195
    • /
    • 2006
  • This research was designed to evaluate the nutritional an microbiol quality assessment of Chungmukimbab purchased from market in Tongyeoung area. Contents of calories, calcium, iron, thiamin and riboflavin in ordinary kimbab and Chungmukimbab were lower than the recommended levels of Korean adult men. So, We suggested that a fruit, beverage and ffod stuff were supplemented to maintain nutritional balance. Total aerobic bacteria and coliform group of just prepared ordinary kimbab and Chungmukimbab samples from market were not significantly different, showing approximately $5.50{\pm}0.38 log_{10} CFU/g,\;2.10{\pm}0.47log_{10}MPN/100g$ in ordinary kimbab, $5.61{\pm}0.42log_{10}CFU/g,\;1.75{\pm}0.34 log_{10} MPN/100g$ in Chungmukimbab, respectively. Total aerobic bacteria of law ingredients of chungmukimbab sample were 3 to $4 log_{10}CFU/g$ in kimbab, seasoning squid and radish roots kimchi, 4 to $5 log_{10}CFU/g$ in boiled fish paste. The coliform groups were 1 to $2 log_{10}$ MPN/100 g in kimbab, seasoning squid and radish roots kimchi, 2 to $3 log_{10}$ MPN/100g in boiled fish paste. Detection rate of E. coli and Staphylococcus aureus counts were 10.0, 12.5% in Chungmu-kimbab, 15.0, 10.0% in seasoning squid, 0, 10.0% in radish roots kimchi respectively, not detected in boiled fish paste samples. During storage at $15^{\circ}C$ for 24 hours, total aerobic counts and coliform groups in ordinary kimbab and Chungmukimbab were increased by the 1.94, $0.97log_{10}CFU/g$, 0.60, 0.72 log10 MPN/100g respectively. Total aerobic counts of Chungmukimbab ingredients increased $0.83{\sim}l.33 log_{10}CFU/g$ at different time

A Study on Concentration of the Airbrone Copper and Biological Exposure Index in the Workplaces Manipulating the Copper (동(銅) 취투(取投) 작업장(作業場) 공기중(空氣中) 동(銅) 농도(濃度)와 생물학적폭로지수(生物學的暴露指數))

  • Jeung, Jae Yeal;Kim, Jung Man;Kim, Doo Hie
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.3 no.1
    • /
    • pp.78-90
    • /
    • 1993
  • This study was designed obtain and early detection the workers exposed to excessive copper dust and also to present biological exposure index. The exposed group consisted of 62 male workers at the metallurgy workplaces. To evaluate the degree of individual exposure the copper dust, each personal air sampling was collected. Biological exposures in the exposed group was quantified for the blood and urine copper levels using flameless atomic absorption spectrophotometer. The control group consisted of 70 male adults with the history of nonexposure to copper by the inhalation occupationally. The average concentration of copper in blood and urine of the exposed group was $49.44{\pm}8.90(29.05-80.63){\mu}g/dl$, $39.99{\pm}11.04(29.62-80.63){\mu}g/l$ respectively. The average concentration of air borne copper was $0.48{\pm}0.31(0.03-1.18)mg/m^3$. The average concentration of blood and urine copper in the control group was $42.93{\pm}5.84(25.05-57.85){\mu}g/dl$, $33.02{\pm}13.38(12.00-82.05){\mu}g/l$ respectively. The difference observed in the average concentration of blood and urine copper of the exposed and control groups was statistically significant seperately (blood copper, p<0.05 ; urine copper, p<0.05). The relationship between the individual exposure concentration of air borne copper and the concentration of the blood and urine copper was statistically significant, respectively (blood copper, r=0.54, p<0.05 ; urine copper, r=0.37, p<0.05). The relationship between the working duration and the concentration of blood and urine was not statistically significant respectively (blood copper, r=0.14 ; urine copper, r=0.12). The relationship between the age and the concentration of blood and urine copper was statistically not significant respectively (blood copper, r=013 ; urine copper, r=-0.06). The relationship between blood and urine copper concentration in the exposed group was statistically significant (r=0.62, p<0.05), and the relationship between blood and urine copper concentration in the control group was also statistically significant (r=0.39, p<0.05).

  • PDF

Comparison of Rotational Strength in Shoulders with Anterior Instability and Normal Shoulders Using Isokinetic Testing (등속성 검사를 통한 견관절 전방 불안정 환자와 정상인의 회전력 비교)

  • Lee, Dong-Ki;Kim, Tae-Kwon;Lee, Jin-Hyuck;Lee, Dae-Hee;Jung, Woong-Kyo
    • Clinics in Shoulder and Elbow
    • /
    • v.15 no.2
    • /
    • pp.79-85
    • /
    • 2012
  • Objective: It has been expected that patient with posttraumatic recurrent anterior shoulder dislocation might have limited daily life activity because of pain and apprehension of dislocation. But there have been only a small number of investigations regarding the rotator strength in this patient. The aim of this study is to find the characteristics about rotator strength of patient with posttraumatic recurrent anterior shoulder dislocation using an isokinetic testing. Method: We enrolled thirteen patients with posttraumatic recurrent anterior shoulder dislocation and fifteen sex, age-matched healthy nonathletic subjects in this controlled study. All participants were male and there were no significant differences between the two groups in age, height, weight, BMI. Isokinetic internal rotator and external rotator strength was evaluated with a Biodex Isokinetic Testing machine (Biodex Medical Systems, Shirley, NY, USA), tests were performed at 60 deg/sec and 180 deg/sec for both sides. Peak torque normalized to body weight, external rotator to internal rotator ratio, total work and fatigue were calculated for each angular velocity. The association between internal rotator and external rotator strength and shoulder instability was analyzed by comparisons with a control group. Results: Any notable differences could not be found between the two groups given all data from no symptomatic left shoulder. There were no significant differences between the two groups statistically in internal rotation strength of right shoulder. However, there has been a tendency that at all angular velocities, external rotator peak torque to body weight, total work and external rotator to internal rotator ratio were significantly lower in the anterior instability group than the control group at all angular velocities. There was no substantial difference between those groups with respect to the fatigue of external rotator and internal rotator in our study. Conclusion: The prominent characteristics of posttraumatic recurrent anterior shoulder dislocation are external rotator weakness and loss of balance with external rotator and internal rotator. Therefore selective training using this information rotator might be helpful in conservative treatment and rehabilitation.

Investigation of Perfusion-weighted Signal Changes on a Pulsed Arterial Spin Labeling Magnetic Resonance Imaging Technique: Dependence on the Labeling Gap, Delay Time, Labeling Thickness, and Slice Scan Order (동맥스핀표지 뇌 관류 자기공명영상에서 라벨링 간격 및 지연시간, 표지 두께, 절편 획득 순서의 변화에 따른 관류 신호변화 연구)

  • Byun, Jae-Hoo;Park, Myung-Hwan;Kang, Ji-Yeon;Lee, Jin-Wan;Lee, Kang-Won;Jahng, Geon-Ho
    • Progress in Medical Physics
    • /
    • v.24 no.2
    • /
    • pp.108-118
    • /
    • 2013
  • Currently, an arterial spin labeling (ASL) magnetic resonance imaging (MRI) technique does not routinely used in clinical studies to measure perfusion in brain because optimization of imaging protocol is required to obtain optimal perfusion signals. Therefore, the objective of this study was to investigate changes of perfusion-weighed signal intensities with varying several parameters on a pulsed arterial spin labeling MRI technique obtained from a 3T MRI system. We especially evaluated alternations of ASL-MRI signal intensities on special brain areas, including in brain tissues and lobes. The signal targeting with alternating radiofrequency (STAR) pulsed ASL method was scanned on five normal subjects (mean age: 36 years, range: 29~41 years) on a 3T MRI system. Four parameters were evaluated with varying: 1) the labeling gap, 2) the labeling delay time, 3) the labeling thickness, and 4) the slice scan order. Signal intensities were obtained from the perfusion-weighted imaging on the gray and white matters and brain lobes of the frontal, parietal, temporal, and occipital areas. The results of this study were summarized: 1) Perfusion-weighted signal intensities were decreased with increasing the labeling gap in the bilateral gray matter areas and were least affected on the parietal lobe, but most affected on the occipital lobe. 2) Perfusion-weighted signal intensities were decreased with increasing the labeling delay time until 400 ms, but increased up to 1,000 ms in the bilateral gray matter areas. 3) Perfusion-weighted signal intensities were increased with increasing the labeling thickness until 120 mm in both the gray and white matter. 4) Perfusion-weighted signal intensities were higher descending scans than asending scans in both the gray and white matter. We investigated changes of perfusion-weighted signal intensities with varying several parameters in the STAR ASL method. It should require having protocol optimization processing before applying in patients. It has limitations to apply the ASL method in the white matter on a 3T MRI system.

The Correlation Analysis of Ejection Fraction: Comparison of $^{201}Tl$ gated Myocardial Perfusion SPECT and Echocardiography ($^{201}Tl$ 게이트 심근관류 SPECT 및 심초음파의 좌심실 구혈률 상관관계 비교)

  • Yoon, Soon Sang;Ryu, Jae Kwang;Cha, Min Kyung;Lee, Jong Hun;Kim, Sung Hwan
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.2
    • /
    • pp.49-56
    • /
    • 2012
  • Purpose : Gated myocardial perfusion SPECT provides not only myocardial perfusion status, but various functional parameters of left ventricle (LV). The purpose of this study was to analyze ejection fraction (EF) for correlation and difference between $^{201}Tl$ gated myocardial perfusion SPECT and echocardiography depending on extent of perfusion defect, gender and LV volumes. Materials and Methods : From April 2011 to May 2012, we analyzed 291 patients (male:female =165:126; mean: $64.6{\pm}10.8$ years) who were examined both $^{201}Tl$ gated myocardial perfusion SPECT and echocardiography at less than 7 days apart in our hospital. 101 patients showed perfusion defect and the rest of the people without any defect. We applied automatic analysis (Quantitative gated SPECT, QGS), and calculated EF, End-diastolic volume (EDV) and End-systolic volume (ESV) from Stress (G-Stress) and Rest (G-Rest) studies. And we analyzed the correlation and difference for EF between $^{201}Tl$ gated SPECT and echocardiography. Results : The correlation of LVEF among G-Stress, G-Rest and echocardiography was quite a good (G-Stress vs. G-Rest: r=0.909, G-Stress vs. echocardiography: r=0.833, G-Rest vs. echocardiography: r=0.825). And there were significant differences in EDV, ESV and EF in total patients (p<0.01). The normal group showed significant difference in EF (p<0.01) and the group with perfusion defect also demonstrated significant difference (a group with reversible defect: p<0.01, fixed defect: p<0.01) depending on extent of perfusion defect. We analyzed difference in normal group by gender. In normal group, there was no significant difference (p>0.05) in EF from men. However, there was a significant difference (p<0.01) from women. When we classified two groups by average size of EDV in Korean women, there was no significant difference in a group of above average size of EDV (p>0.05). Conclusion : When compared among Stress and Rest of $^{201}Tl$ gated SPECT and echocardiography, we confirmed that there was a good correlation for LVEF. But there were significant differences among three studies. And extent of perfusion defect, gender and LV volumes are independent determinants of the accuracy of LVEF. So, it is hard to compare and interchange quantitative indices among modalities. We should take additional researches to prove results of our study.

  • PDF