Trained singers, one group of professional voice users, have much more interest on the voice than common people, and on its management, too. They train for singing beautiful songs, and, at the same time, try for efficient voice production. The present study was performed with three tenors and three baritones, undergraduate students majored in classical singing, to investigate the degree of improvement of their voice production efficiency through vocal function exercise, by measuring the three dependent variables, maximum phonation time, speed quotient of glottal contact, and the number of semi tones. For the baseline establishment, dependent variables were measured 3$\sim$6 times for two weeks. Then, the subjects exercised vocal function exercise for seven weeks, and after the termination of training, evaluation was performed four times for two weeks, to find the maintenance of the training effect. Vocal function exercise is composed of four successive steps: warm-up, stretching exercise, contracting exercise, power exercise. As results, all of six subjects showed improvement in the aspect of maximum phonation time, speed quotient if glottal contact, and the number of semitones.
The pitch range of the human voice is variable, extending from chest register to falsetto. Although numerous studies have investigated after laryngeal mechanism description of registers, systematic and objective studies were lack. The purpose of this study was to analyze and compare head register with chest register of singers acoustically. Fifteen healthy tenor major students were selected. Fifteen healthy untrained adults were the control group for this study. Long term average(LTA) power spectrum using the Fast Fourier transform(FFT) algorithm and Linear predictive coding (LPC) filter response were made during /a/ sustained in both head(G4, 392Hz) md chest registers (C3, 131Hz). Statistical analysis was performed using Mann-Whitney test. In the LTA power spectrum, head register of singer has increased level(energy gain) in the frequency band of 2.2-3.4kHz(p<0.01), and 7.5-8.4kHz(p<0.01, p<0.05). Chest register of singer has increased level in the frequency band of 2.2-3.1kHz(p<0.01), 7.8-8.4kHz(p<0.05) and around 9.6kHz(p<0.01). LTA power spectrum reveals a peak of acoustic energy around 2500Hz known as the singer's formant and another peak of acoustic energy around 8000Hz in singer's voice.
Aerodynamic study is valuable information about the vocal efficiency in translating airflow to acoustic signal. The purpose of this study was to investigate the differences between trained singers and untrained controls under different two pitch by simultaneous using the airway interruption method and electroglottography (EGG). Under singing a Korean lied 'Gene', 20 (Male 10, Female 10) trained singers were studied on two one-octave different tone. Mean flow rate (MFR) , subglottic pressure (Psub) and intensity were measured with aerodynamic test using the Phonatory function analyzer (Nagashima Ltd. Model PS 77H, Tokyo, Japan). Closed quotients (Qx), jitter and shimmer were also investigated by electroglottography using Lx speech studio (Laryngograph Ltd, London, UK). These data were compared with those of normal controls. MFR and Psub were increased on high pitch tone in all subject groups. Statistically significant increasing of Qx and intensity were observed in male trained singers on high pitch tone (Qx;p = .025, intensity;p < .001). Beacasue of increasing of Qx and intensity, vocal efficiency was also significantly increased in male singers (p < .001). The trained singers' phonation was more efficient than untrained singers. The result means that the trained singers can increase the loudness with little changing of mean flow rate, subglottic pressure but more increasing of glottic closed quotients.
Background and Objectives : The most important two factors of the voice production are the respiratory function which is the power source of voice and the glottic closure that transform the air flow into sound signals. The purpose of this study was to investigate the differences between trained singers and untrained controls under varying intensity at a constant vocal pitch by simulataneous using the airway interruption method and electroglottography(EGG). Materials and Methods : Under two different intensity condition at a constant vocal pitch(/G/), 20(Male 10, Female 10) trained singers were studied. Mean flow rate(MFR), subglottic pressure(Psub) and intensity were measured with aerodynamic test using the Phonatory function analyzer. Closed quotients(CQ), jitter and shimmer were also investigated by electroglottography using Lx speech studio. These data were compared with that of normal controls. Results : MFR and Psub were increased on high intensity condition in all subject groups but there was no statistically significance. Statistically significant increasing of CQ. were observed in male trained singers on high intensity condition (untrained male : 51.31${\pm}$3.70%, trained male :55.52${\pm}$6.07%, p=.039). Shimmer percent, one of the phonatory stability parameters, was also decreased statistically in all subject groups(p<.001). Conclusion : The trained singers' phonation was more efficient than untrained singers. The result means that the trained singers can increase the loudness with little changing of mean flow rate, subglottic pressure but more increasing of glottic closed quotients.
Objectives : The purpose of this study was to systematically analyze and compare e acoustic sound structure of vocal major student's singing voice. Materials and Methods : The nineteen vocal major students were the subject group and healthy nineteen females were the control group for this study. The subject group was taken a strobovideolaryngoscopy by the use of flexible nasopharyngoscopy. And acoustic analysis was taken between two groups. Additionally the inquiry on usual voice problems and management was performed by thirty-six vocal major students. Results : The subject group presents many functional voice disorder findings such as AP contraction(44%), phase difference(36%) tremor(25%), posterior gap(17%), hyperadduction of vestibular fold(6%), and anterior gap(3%) on strobovideolaryngoscopy. And the vocal major students did reveal an enhanced number of high frequency harmonic partials when singing compared to the control group in the narrow band spectrum study. But there was no significant difference in jitter, shimmer and noise to harmonic ratio in both groups. Almost all vocal major students present a lot of voice problems in singing such as loss of high note(17%), loss of quiet voice(17%), effortful and tired voice(36%) etc on inquiry. And they always effort to prevent vocal dysfunction by the use of various type of method such as voice rest(28%), hydration(28%), gargling with salt(11%) etc. Conclusions : The vocal major students always take care of maintaining a good voice condition, but a lot of vocal major students revealed abnormal strobovideolaryngoscopic findings and they are absent in the conception of systemic and scientific voice management. Therefore, the young singers need a good voice training and voice therapy Program under the good ralationship of laryngologist and voice training teacher.
The purpose of this study is to find clues to the risk of voice disorders in soprano students. The subjects of the study were 17 soprano students and 18 general students (women). The phonation of vowels /a/, /i/, and /u/ with C4 and F4 notes in each group were recorded. Then, only soprano students were made to record their classical vocalization containing vibrato. Formant, formant energy, bandwidth, VAI (vowel area index), VSA (vowel space area) and L/H ratio were analyzed. There was significant difference in F3 such that the singers' note was measured around 3 kHz which seems to be 400 Hz higher than one from general students. But, There was no significant difference in L/H ratio between soprano student and the general student. There was a significant difference in F3 in the comparison of the soprano students' two vocalization methods. Classical vocalization was measured at 200Hz higher than sustained phonation in F3. Vocal tract adjustment was made and vowel space changed, but there was no significant difference in F3 energy, which is the index of singers' formant according to the phonation method. The L/H ratio, which can be a direct indicator of vocal effort, has no difference in phonation method and is lowered in all phonation methods as the pitch increases. C4 and F4 pitches are lower than the singing range of the soprano. When the pitch changes, vocal effort increases like a general student which will be an indicator of the risk of vocalization. This will be a clue to the vocalization of the immature soprano student.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.