• Title/Summary/Keyword: 성능실증

Search Result 515, Processing Time 0.029 seconds

Numerical Analysis and Demonstration Test on the Performance of a Static Mixer for mixing Biogas and Town Gas for the 5MW Biogas Turbine (5MW 바이오가스 터빈의 바이오가스와 도시가스 혼합용 정적 혼합기의 성능에 관한 수치해석 및 실증 연구)

  • Cha, Hyoseok;Song, Soonho;Park, Jong Yeon;Kim, Young Il;Mun, Sung Young
    • Journal of Energy Engineering
    • /
    • v.24 no.1
    • /
    • pp.51-57
    • /
    • 2015
  • The purpose of this study is to verify the performance of a static mixer for mixing of biogas and town gas by numerical analysis and demonstration test. The reason for designing a static mixer is that there is a need to mix town gas with biogas when there is less production of biogas in biogas sites. Non-uniformity in the outlet section was calculated for investigating the performance of a static mixer. Non-uniformity was based on the mole fraction of methane in a mixture of biogas and town gas. Low non-uniformity means that biogas and town gas are mixed well through this static mixer. Also, pressure drop at the outlet section of a static mixer was calculated. The pressure drop is less than 0.2% in this static mixer. This static mixer is suitable for applying to a 5MW bio-gas turbine through the demonstration test in the field.

Evaluation of Mechanical Properties for the Compacted Bentonite Buffer Materials (압축 벤토나이트 완충재의 역학 물성 평가)

  • Yoon, Seok;Hong, Chang-Ho;Kim, Taehyun;Kim, Jin-Seop
    • Journal of the Korean Geotechnical Society
    • /
    • v.37 no.10
    • /
    • pp.5-11
    • /
    • 2021
  • The compacted bentonite buffer is one of the most important components in an engineered barrier system (EBS) to dispose of high-level radioactive waste (HLW) produced by nuclear power generation. The compacted bentonite buffer has a crucial role in protecting the disposal canister against the external impact and penetration of groundwater, so it has to satisfy the thermal-hydraulic-mechanical requirements. Even though there have been various researches on the investigation of thermal-hydraulic properties, few studies have been conducted to evaluate mechanical properties for the compacted bentonite buffer. For this reason, this paper conducted a series of unconfined compression tests and obtained mechanical properties such as unconfined compressive strength, elastic modulus, and void ratio of Korean compacted bentonite specimens with different water content and dry density values. The unconfined compressive strength and elastic modulus increased, and the Poisson's ratio decreased a little with increasing dry density. It showed that unconfined compressive strength and elastic modulus were proportional to dry density. However, there was not a remarkable correlation between mechanical properties and water content.

Engineering-scale Validation Test for the T-H-M Behaviors of a HLW Disposal System (고준위폐기물 처분시스템의 열적-수리적-역학적 거동 규명을 위한 공학적 규모의 실증시험)

  • Lee Jae-Owan;Park Jeong-Hwa;Cho Won-Jin
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.4 no.2
    • /
    • pp.197-207
    • /
    • 2006
  • The engineering performance of a high level waste repository is significantly dependent upon the T-H-M behavior in the engineered barrier system. An engineering-scale test facility (KENTEX) was set up to validate the T-H-M behaviors in the buffer of a reference disposal system developed in the 2002. The validation tests started on May 31, 2005 and is now in progress. The KENTEX facility and validation test programme are introduced, and pre-operation calculations are also presented to give information on the sensitive location of sensors and operational conditions. This test will provide information (e.g., large-scale apparatus, sensors, monitoring system etc.) needed for 'in-situ' tests, make the validation of a T-H-M model for the T-H-M performance assessment of the reference disposal system, and demonstrate the engineering feasibility of fabricating and emplacing the buffer of a repository.

  • PDF

Development of CITIS Model and Analysis of Its functionality as a Collaborative Virtual Factory for Construction Projects (건설프로젝트의 협업적 가상기업으로서의 CITIS 모델개발 및 성능분석에 관한 연구)

  • Han Seung Heun;Chin Kyung Ho
    • Korean Journal of Construction Engineering and Management
    • /
    • v.3 no.2 s.10
    • /
    • pp.87-98
    • /
    • 2002
  • Korea government is making an effort to improve the efficiency in construction industry by introducing CITIS (Contractor integrated Technical Information Service). In order to provide a base for the application of CITIS into the construction industry, this research provides a concept of virtual factory which should be incorporated into CITIS system for the successful collaborative work in the virtual space. It then implements a prototype system through process and data modeling to apply into the road construction projects. The prototype system is tested to verify its efficiency. Finally, lesson learned from these works is provided to advance the current CITIS toward a collaborative virtual factory.

Mechanical Calibration of 750 kW Gearless Type Wind Turbine(KBP-750D) (750 kW급 직결형 국산화 풍력발전시스템의 기계적 보정)

  • Gil, Kye-Hwan;Choi, Hyo-Jin;Kim, Young-Chan;Chung, Chin-Wha;Cho, Joo-Suk
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2008.05a
    • /
    • pp.337-340
    • /
    • 2008
  • 포항공과대학교의 포항풍력에너지연구소(PoWER Center)가 개발에 참여했던 750 kW급 직결형 국산화 풍력발전 시스템의 상용화를 추진하기 위한 출력성능 및 하중 측정을 통한 실증연구가 대관령의 풍력실증단지에서 수행되었다. IEC 61400-13의 규격을 기준으로 수행된 하중 측정의 일환으로 스트레인 게이지의 기계적 하중에 대한 외부 하중부가에 의한 기계적 보정이 추진되었다. 기계적 보정의 수행 중 일부스트레인 게이지가 단락되는 사고가 발생하였으나 비교보정을 통하여 기계적 보정작업을 완수할 수 있었다. 본 논문에서는 외부 하중부가에 의한 기계적 하중의 보정절차를 소개하고, 수행된 기계적 보정시험 과정에 대해 상세히 설명하며 기계적 보정의 결과를 보고한다.

  • PDF

6kw급 소형풍력발전기 실증연구결과

  • Kim, Sang-Jin;Kim, Yeong-Dal;Kim, Yong-Hwan;Hwang, Cheol-Hoe;Park, Geon-Sik;Nam, Yong-Tae;Park, Jong-Bok;Yu, Neung-Su;Kim, Seok-Hyeon;Gang, Sin-Yu;Nam, Yun-Su;Lee, Jeong-Wan;Kim, Byeong-Hui
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2005.11a
    • /
    • pp.205-218
    • /
    • 2005
  • 본 연구는 IEC 규정에 의거해 6kw급 소형풍력발전기 성능실증연구를 수행하였다. 실증연구를 수행하기 위하여 풍력발전기에 각종 센서를 설치, 측정 사이트에 모니터링 시스템을 구성하여 데이터를 수집 분석하였다.

  • PDF

태양전지 모듈의 옥외실증시험을 통한 열화요인 분석

  • Kim, Hyeon-A;Choe, Jeong-Jin;Kim, Sang-Cheol
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.494.2-494.2
    • /
    • 2014
  • 실리콘 태양전지는 현재 다른 태양전지 셀에 비해서 높은 변환효율 및 우수한 안정성을 가지고 있으며, 상대적으로 가격도 저렴하여 상용으로 판매되는 대다수의 모듈이 실리콘 태양전지를 사용하고 있다. 이러한 태양전지 모듈이 25년 이상 보증을 위해서는 장기 열화메카니즘 연구가 중요시 되고 있다. 따라서 태양전지 모듈을 가속열화하여 높은 내구성을 보유하고 있는지 연구가 필요하다. 본 연구에서는 결정질 실리콘 태양전지 모듈의 옥외실증 시험을 통해 일사량, 기온, 습도, 풍향, 풍속과 같은 환경인자에 따른 모듈의 성능 비교를 통해 모듈의 열화요인에 대하여 분석하였다. MYPGT (Maximal Yield Power Generation Tracking)를 활용하여 모듈의 특성을 정밀하게 측정하며, 빠른 대기환경의 변화에 따른 매시간 태양전지의 전류-전압 특성을 지속적으로 정확하게 측정함으로써 대기환경에서 받는 영향에 대해 분석하였다.

  • PDF

Performance evaluation of concentrator photovoltaic modules with aluminium reflectors (반사판을 이용한 집광형 태양광 모듈 실증 연구)

  • Jeong, Hye-Jeong;Lee, Young-Woo;Ryoo, Hee-Soo;Boo, Seong-Jae
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.114-117
    • /
    • 2008
  • 본 연구에서는 알루미늄 반사판을 이용한 저집속 (2.25X) 집광형 태양광 모듈을 설계 및 제작하여 실증 연구를 실시하였다. 반사판을 이용한 집광형PV시스템의 성능향상을 평가하기 위하여, 일사량과 모듈온도 변화에 따른 출력변화와 효율변화를 평판형 모듈과 집광형 모듈에 대해서 각각 측정하고 비교하였다. 결과적으로 반사판을 사용 집속한 모듈이 약 20% 이상의 출력 증가를 보였으며, 모듈의 평균 온도 상승에도 불구하고 1.4 배의 발전효율 증가를 확인하였다.

  • PDF

한국원자력연구소 실증소각시설에서의 방사성폐기물 실증소각

  • 양희철;김인태;김정국;김준형;서용칠
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1995.05b
    • /
    • pp.827-832
    • /
    • 1995
  • 한국원자력연구소 실증소각시설의 성능 및 운전성을 입증하기 위하여 방사성동위원소를 포함한 모의폐기물 및 원자력발전소 발생 방사성폐기물에 대한 시험소각을 실시하였다. 비휘발성인 $^{60}$Co 및 $^{54}$Mn의 거동은 비산재의 거동과 거의 유사하였으며 각각의 제염계수는 4.7 x $10^{5}$및 6.2 x $10^{5}$이었다. 반휘발성인 $^{137}$Cs의 경우에는 8$50^{\circ}C$$700^{\circ}C$의 다른 소각온도에서 각각 2.8 $\times$ $10^4$, 2.6 $\times$ $10^3$으로 소각온도의 의존성을 보여주었다. 원자력발전소에서 운반된 건조 방사성폐기물(DAW)에 대한 시험소각은 성공적으로 수행되었다. 총 베타/감마 방사능에 대한 제염계수가 1.1 $\times$ $10^{5}$이었으며 결과적인 연돌에서의 배출농도는 0.019 Bq/N㎥으로 기체상 배출물에 대한 최대허용농도를 만족시킬 수 있었다.수 있었다.

  • PDF

Analysys of results of demonstration test of remote control system for unmanned ships for detecting marine and fishery disasters (해양수산재해 탐지용 무인선의 원격관제 시스템 실증시험 결과 분석)

  • 강은구;한정욱;김선영;박한솔;표춘선;박규린;박재현
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2021.11a
    • /
    • pp.136-138
    • /
    • 2021
  • 본 논문은 경남무인선박 규제자유특구 혁신사업육성 실증 사업의 일환으로 선박해양플랜트연구소(KRISO) 주관으로 수행한 연구 개발 사업의 실증 시험 수행 및 성과에 관련된 내용임. 선박해양플랜트연구소 무인선 아라곤2호와 3호에 적용한 원격관제 시스템의 고도화 및 성능개선 관련 연구개발 수행 중이다.

  • PDF