• Title/Summary/Keyword: 성능실증

Search Result 511, Processing Time 0.028 seconds

The Heat Pump Application to the Food Concentration (열 펌프의 식품 농축에의 이용 연구)

  • Park, Noh-Hyun;Kim, Byeong-Sam;Kang, Tong-Sam;Shin, Dong-Hwa
    • Korean Journal of Food Science and Technology
    • /
    • v.19 no.6
    • /
    • pp.486-491
    • /
    • 1987
  • The performance and applicability to food concentration of heat pump were investigated. During heating the water of spa from $43^{\circ}C$ to $51^{\circ}C$, COP's of heat pump (R-12, 150 HP) were 4.03 at heating part and 3.5 at cooling part. And, the efficiency of compressor (${\alpha}$) was 0.477 While the city water was heated to $39^{\circ}C$ by heat pump (R-22, 10 HP), its COP's were 3.0 at heating part and 1.87 at cooling part. During concentrations sucrose solution by centrifugal evaporator (ALFA-LAVAL CO, CTIB) with heat pump, heat capacity for condensating water vapor was required greater 15% than the latent heat for concentrating and then the overall heat transfer coefficient was $1196\;Kcal/m^{2}.\;h.\;^{\circ}C$. When low temperature concentration ($30-35^{\circ}C$, 28-40 Torr) of garlic extract was carried out by the water of $60^{\circ}C$ and $15^{\circ}C$ adjusted by heat pump, the ratio of heat capacity for concentrating vs. that for condensating of water vapor was 0.961.

  • PDF

Study of NIR in-line Monitoring of Physicochemical Changes during the Crystallization Process of Aspirin (Aspirin 결정화 과정 중 특성변화의 NIR 인라인 모니터링 연구)

  • Lee, Hea-Eun;Wang, In-Chun;Lee, Min-Jeong;Seo, Da-Young;Shin, Sangmun;Choi, Yongsun;Choi, Guang-Jin
    • Korean Chemical Engineering Research
    • /
    • v.48 no.6
    • /
    • pp.757-762
    • /
    • 2010
  • Since the quality and performance of medicinal products are heavily dependent upon the size, shape and polymorphism of active pharmaceutical ingredients(APIs), their crystallization has been regarded as one of the most important pharmaceutical processes. In this study, NIR-based inline measurements were employed to monitor key attributes of API particles real-time during the crystallization process. Principal component analysis(PCA) method was selected to correlate inline NIR spectra while the well-known aspirin was studied as a model drug. According to our characterization results, the ratio of ethanol to acetone did not cause any change in polymorphism, but resulted in a significant difference in the nucleation time, crystal growth and crystal shape. These phenomenological changes were well correlated with the PCA's implications. It turned out that the NIR-based inline monitoring technology can be employed well in observing and predicting key quality attributes such as crystal size during pharmaceutical crystallization processes.

Potential of Coal Gasification Slag as an Alkali-activated Cement (석탄가스화 복합발전 슬래그의 알칼리 활성 시멘트로서의 가능성)

  • Kim, Byoungkwan;Lee, Sujeong;Chon, Chul-Min;Choi, Hong-Shik
    • Resources Recycling
    • /
    • v.27 no.2
    • /
    • pp.38-47
    • /
    • 2018
  • Integrated gasification combined cycle (IGCC) is a next generation energy production technology that converts coal into syngas with enhanced power generation efficiency and environmental performance. IGCC produces almost coal gasification slag as the solid by-product. IGCC slag is generated about 140,000 tons for a year although recycling of it is still in the early stages. We evaluated the potential of IGCC slag which is generated from a pilot plant in South Korea as an alkali-activated cement. Samples which were activated with the combined activator of sodium silicate solution and caustic soda had an average compressive strength of 4.5 MPa, showing expansion. Expansion of the alkali-activated slag was presumed to be caused by free CaO in the slag, although it was not detected by the ethylene glycol method. Samples that were activated with the combined activator of sodium aluminate and caustic soda had an average compressive strength of 10 MPa. Hydroxy sodalite and $C_3AH_6$ were found to be the new crystalline phases. IGCC slag can be used as an alkali-activated material, but the strength performance should be improved with proper mix design approach to calculate optimum proportions which can alleviate the expansion issue at the same time.

Algorithm of Analysing Electric Power Signal for Home Electric Power Monitoring in Non-Intrusive Way (가정용 전력 모니터링을 위한 전력신호 분석 알고리즘 개발)

  • Park, Sung-Wook;Wang, Bo-Hyeun
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.21 no.6
    • /
    • pp.679-685
    • /
    • 2011
  • This paper presents an algorithm identifying devices that generate observed mixed signals that are collected at main power-supply line. The proposed algorithm, which is necessary for low cost electric power monitoring system at appliance-level, that is non-intrusive load monitoring system, divides incoming mixed signal into multiple time intervals, calculating difference-signals between consecutive time interval, and identifies which device is operating at the time interval by analysing the difference-signals. Since the features of one device can remain when the time interval is short enough and the features are independent and additive, well-known classification algorithms can be used to classify the difference-signals with features of N individual devices, otherwise $2^N$ features might be necessary. The proposed algorithm was verified using data mixed in a laboratory with individual devices's data collected from field. When maximum 4 devices operate or stop sequentially and when features satisfy the requirements of proposed algorithm, the proposed algorithm resulted nearly 100% success rate under the constrained test condition. In order to apply the proposed algorithm in real world, the number devices shall increase, the time interval shall be smaller and the pattern of mixture shall be more diverse. However we can expect, if features used follow guidelines of proposed algorithm, future system could have certain level of performance without the guideline.

The Effects of Products Characteristics, Consumers Characteristics on Products Attitudes and Purchasing Intention of Import Agency Shopping Malls -Focused on the Moderating Effect of Perceived Risk- (수입대행쇼핑몰의 제품 특성과 소비자 특성이 제품태도 및 구매의도에 미치는 영향 -지각된 위험의 조절효과를 중심으로-)

  • Song, Sun-Yok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.1
    • /
    • pp.340-348
    • /
    • 2016
  • This study, through a review of advanced research, first, examined the attitudes to products traded in import agency shopping malls and the characteristic variables(product characteristic, customer characteristic) that influence the purchasing intention to understand influencing relationship. Second, the role of adjustment in the relationship between the attitude to the products and the purchasing intention was examined by putting the perceived risk to the moderating variables. Third, efficient controllable basic data in the characteristic variables capable of influencing the management of and import agency shopping mall based on the implications was obtained from the above research result. The 126 responses collected from a questionnaire were analyzed using the SPSS 23.0 statistics package, and the analysis result can be summarized as follows. First, the main cause that influences the attitude of treated products in an import agency shopping mall is the country of origin, national image, innovativeness and price perception, not the brand image. Second, the attitude of the products influences the purchasing intention of the import agency shopping mall. Third, the perceived risk partially plays a role as a moderating variable in the relationship between the attitude of products and the purchasing intention.

An Experimental Environment for Simulation of Stealthy Deception Attack in CPS Using PLCitM (PLC in the Middle) (중간자 PLC를 이용한 CPS 은닉형 공격 실험환경 구축 방안)

  • Chang, Yeop;Lee, Woomyo;shin, Hyeok-Ki;Kim, Sinkyu
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.28 no.1
    • /
    • pp.123-133
    • /
    • 2018
  • Cyber-Physical System (CPS) is a system in which a physical system and a cyber system are strongly integrated. In order to operate the target physical system stably, the CPS constantly monitors the physical system through the sensor and performs control using the actuator according to the current state. If a malicious attacker performs a forgery attack on the measured values of the sensors in order to conceal their attacks, the cyber system operated based on the collected data can not recognize the current operation status of the physical system. This causes the delay of the response of the automation system and the operator, and then more damage will occur. To protect the CPS from increasingly sophisticated and targeted attacks, countermeasures must be developed that can detect stealthy deception attacks. However, in the CPS environment composed of various heterogeneous devices, the process of analyzing and demonstrating the vulnerability to actual field devices requires a lot of time. Therefore, in this study, we propose a method of constructing the experiment environment of the PLCitM (PLC in the middle) which can verify the performance of the techniques to detect the CPS stealthy deception attack and present the experimental results.

Performance Assessment and Design Evaluation of Bioretention Planter Boxes Treating Urban Stormwater Runoff (도심지역 강우유출수 처리목적 식물재배화분의 성능 및 설계인자 분석)

  • Guerra, Heidi B.;Park, Kisoo;Kim, Youngchul
    • Journal of Wetlands Research
    • /
    • v.20 no.1
    • /
    • pp.72-79
    • /
    • 2018
  • Two planter boxes were monitored during their initial year of operation to be able to assess their stormwater runoff and pollutant reduction capabilities and investigate on the design factors affecting their performance. One of the planter boxes provided 85-100% runoff volume reduction for rainfall less than 15 mm and rainfall intensities lower than 5 mm/hr. This reduced to 50-64% during higher rainfall intensities and depths of up to 50 mm. Suspended solids, organics, nutrients, and heavy metals were satisfactorily removed at a range of 40-95%. The other planter box, however, did not produce outflow in all the events and allowed total capture of stormwater. The uncertainty regarding the fate of the runoff in that case required an investigation of the planter box's actual drainage and underground conditions which was deemed outside the scope of the study. Nonetheless, several design improvements and retrofits were suggested based on the provisions of current design guidelines to ensure that the hydraulic and water quality goals are achieved without potential damage to nearby structures. Moreover, continuous monitoring data is required to provide more accurate design evaluation and can serve as a guide in the construction of similar facilities in the future.

An Experimental Study on the Thermal Property of Concrete under the Load Ratio Condition in Fire (화재시 하중재하에 따른 콘크리트의 열적특성에 관한 실험적 연구)

  • Kim, Hyung-Jun;Kim, Heung-Youl;Park, Kyung-Hun;Jung, Jae-Young;Kwan, Ki-Hyuk
    • Fire Science and Engineering
    • /
    • v.23 no.6
    • /
    • pp.66-74
    • /
    • 2009
  • When a fire occurs, the concrete structure's strength decreases by the increasing temperature under the fire in certain condition of constant load. And, the ratio of the axial force is changed by such decreased strength so that the structure is deformed. In this research, considering such case, we have conducted an actual fire test for the concrete lining with constant loading condition and various fire conditions. The specimen adopts the shape condition for small practical specimen defined by the EFNARC and we used 24MPa, 40MPa and 50MPa to analyze the thermal properties by the strength. The ratio of loading is imposed by a certain loading condition based on 20% and 40% of the sectional stress in concrete and MHC Fire is selected to realize the thermal impact of the concrete by rapid increasing temperature. As the result of the experiment, in the same ratio of loading, the 50MPa specimen shows more cracks and spalling as time goes on. The area damaged by the fire, according to the functional criteria of the concrete lining under the fire in ITA, does not satisfy with the standard in lack of 50mm depth from the heating surface at total 200mm lining.

Development of Flood Rapid Defense System(FRDS) suitable for Southeast Asian Disaster (동남아시아 재난에 적합한 도심형 홍수임시차수시스템 개발)

  • Jung, In-Su;Oh, Eun-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.11
    • /
    • pp.8-17
    • /
    • 2018
  • A large urban region in Bangkok, Thailand is often inundated due to shallow water floods along the paved roads that have poor drainage facilities, and that can cause urban flooding. Existing methods, including using sand bags are not effective to prevent flooding in urban areas where the amount of sand is not sufficient. Thus, it is necessary to install artificial flood defense structures. However flooding and overflow defense equipment, which was developed in some advanced nations in Europe and in the USA, is highly expensive and complex construction methods are needed, therefore they are not suitable to be used in Southeast Asia. Thus, it is necessary to develop a flood rapid defense system(FRDS), which is inexpensive and simple to build, but is also highly functional. Thus, this study developed an FRDS that can be applied to Southeast Asia through the careful study of FRDS overviews, an analysis on the development trends in Korea and overseas, and the proposal of development needs and directions of the region. For the system developed, Korean Standards(KS) performance evaluations on leakage ratio deformation tests and impact resistance tests were conducted at the Outdoor Demonstration Test Center(Seosan) in the Korea Conformity Laboratories(KCL) and the system satisfied the standards of KS F 2639(leakage and deformation test) and KS F 2236(impact resistance test). The present study results can not only be applied to urban floods in Southeast Asian nations to cope with flood-related disasters, but also be utilized in flood prone regions and for major facilities in Korea. They can also induce scientific and pro-active responses from major local governments and facility management organizations in relation to urban floods.

Study(IV) on the Development of Charts and Formulae Predicting Allowable Axial Bearing Capacity for Prebored PHC Pile Socketed into Weathered Rock through Sandy Soil Layer - Field Verification of Long-term Allowable Compressive Load of PHC Piles by Analyzing Pile Load Test Results - (사질토층을 지나 풍화암에 소켓된 매입 PHC말뚝에서 지반의 허용압축지지력 산정도표 및 산정공식 개발에 관한 연구(IV) - 압축정재하시험 및 양방향재하시험 자료 분석을 통한 매입 PHC말뚝의 장기허용압축하중의 실증 성능 검증 -)

  • Lee, Wonje;Kim, Chae Min;Yun, Do Kyun;Choi, Yongkyu
    • Journal of the Korean Geotechnical Society
    • /
    • v.35 no.9
    • /
    • pp.29-36
    • /
    • 2019
  • Axial compressive failure loads ($P_n$) of diameter 500 mm and diameter 600 mm A type PHC pile were calculated as 7.7 MN and 10.6 MN, respectively. In the static pile load tests, the maximum axial compressive loads of the above 2 kinds of A type pile were measured as 6.9 MN and 8.8 MN respectively, therefore these measured maximum loads were at the level of 90% and 83% of $P_n$ respectively. Long-term allowable axial compressive loads ($P_a$) of the above 2 kinds of A type pile were 1.7 MN and 2.3 MN respectively. From the bi-directional pile load test data on the prebored PHC piles, it was confirmed that the allowable axial compressive bearing resistance was estimated as 131% of the long-term allowable compressive load of the PHC pile and showed higher than the allowable bearing capacity calculated by the current design method. Therefore, it has been verified that the PHC pile can be used up to the maximum long-term allowable compressive load, and it is suggested that the ultimate pile capacity formula used in the current design for prebored PHC piles should be improved to accommodate the actual capacity.