A Study on Performance of Steel Monocell Expansion Joints (강재형 모노셀 신축이음장치 성능 연구)

  • Kim, Yong-Hoon;Yhim, Sung-Soon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.5
    • /
    • pp.502-509
    • /
    • 2019
  • Studies have been made on performance evaluation of expansion joint systems for an ordinary highway or road bridge. However little study has been made for runway connection bridges at airports. A study on performance evaluated from computer code analysis and shrinkage, extension, and compression repetition tests based on KS F 4425 is conducted to a newly developed expansion joint system which has been installed in a runway connection bridge at Incheon Airport Extension 2 Construction Site. The MIDAS computer code is used to analyze the performance before the manufacture of the mock-up of expansion joint system on the basis of design requirements. Tests based on the KS F 4425 of 2001 year-version are conducted for the mock-up. Domestic codes and standards to validate the performance of the expansion joint system in a connection bridge have been developed for a vehicle. However the expansion joint system tested in this study is installed in a runway connection bridge for an aircraft. Conservatively the heaviest one among airplanes departing and landing at Incheon Airport is assumed level-F $468.4kN/m^2$ and adopted for the tests and analyses in this study. KS F 4425 method is selected for the shrinkage, extension, and compression repetition tests. No remarkable problem was observed for the 2,500-cycle shrinkage and extension and two million-cycle repeatition load tests. The results of this study are expected to contribute to establishment of code and standard for the performance validation of an expansion joint system installed in a runway connection bridge for an aircraft by providing performance test results and computer analysis results based on finite element methods.

Development and Application of Test Apparatus for Classification of Sealed Source (밀봉선원의 성능시험을 위한 장치 개발 및 적용)

  • Kim, Dong-Hak;Seo, Ki-Seog;Bang, Kyoung-Sik;Lee, Ju-Chan;Son, Kwang-Je
    • Journal of Radiation Protection and Research
    • /
    • v.32 no.1
    • /
    • pp.35-44
    • /
    • 2007
  • Sealed sources have to conducted the tests be done according to the classification requirements for their typical usages in accordance with the relevant domestic notice standard and ISO 2919. After each test, the source shall be examined visually for loss of integrity and pass an appropriate leakage test. Tests to class a sealed source are temperature, external pressure, impact, vibration and puncture test. The environmental test conditions for tests with class numbers are arranged in increasing order of severity. In this study, the apparatus of tests, except the vibration test, were developed and applied to three kinds of sealed source. The conditions of the tests to class a sealed source were stated and the difference between the domestic notice standard and ISO 2919 were considered. And apparatus of the tests were made. Using developed apparatus we conducted the tests for $^{192}Ir$ brachytherapy sealed source and two kinds of sealed source for industrial radiography. $^{192}Ir$ brachytherapy sealed source is classified by temperature class 5, external pressure class 3, impact class 2 and vibration and puncture class 1. Two kinds of sealed source for industrial radiography are classified by temperature class 4, external pressure class 2, impact and puncture class 5 and vibration class 1. After the tests, Liquid nitrogen bubble test and vacuum bubble test were done to evaluate the safety of the sealed sources.

Standardization of the Performance Test Procedure for Smoke Control System (제연설비 성능시험방법의 표준화)

  • Kwark, Ji-Hyun
    • Fire Science and Engineering
    • /
    • v.20 no.3 s.63
    • /
    • pp.21-28
    • /
    • 2006
  • Since hot toxic gas included in the fire is the most principal reason of the death and has the fluid mechanical characteristics unlike air, smoke control method appropriate for the figure and structure of a fire room is needed and each unit of the smoke control system requests high performance according to this characteristics, for which performance test procedures and evaluation criteria must be established. Domestic criteria involved with the smoke control consist of the pre-investigation by documents and the part inspection, which has lots of problems because they are far from the performance based evaluation method compared with the references of developed countries. Consequently, domestic and international references were compared and analyzed, problems being emerged and standardization scheme of the test procedure was presented.

Establishment of Quality Control System for Angiographic Unit (IVR장치의 성능 평가 기준 개발)

  • Kang, Byung-Sam;Son, Jin-Hyun;Kim, Seung-Chul
    • The Journal of the Korea Contents Association
    • /
    • v.11 no.1
    • /
    • pp.236-244
    • /
    • 2011
  • Recently, the number of interventional procedures has increased dramatically as an alternative of invasive surgical procedure. The need for the quality control program of the angiographic units has also increased, because of concerns about the increased patient dose and the importance of image quality of angiographic units for the successful procedures. The purpose of this study was to propose an optimal guideline for the quality control program of the angiographic units. We reviewed domestic and international standards about medical imaging system and we evaluated the quality of 61 angiographic units in Korea with the use of NEMA 21 phantom. According to the results of our study, we propose a guideline for the quality control program of the angiographic units. Quality control program includes tube voltage test, tube current test, HVL test, image-field geometry test, spatial resolution test, low-contrast iodine detectability test, wire resolution test, phantom entrance dose test. Proposed reference levels are as follows: PAE < $\pm$ 10% in tube voltage test, PAE < $\pm$ 15% in tube current test, minimum 2.3 mmAl at 80 kVp in HVL test, minimum 'acceptable' level at image-field geometry test, 0.8 lp/mm for detector size of 34-40cm, 1.0 lp/mm for detector size of 28-33cm, 1.2 lp/mm for detector size of 22-27cm in spatial resolution test, minimum 200mg/cc in low contrast iodine detectability test, phantom entrance dose should be under 10R/min, 0.012 inch wire should be seen at static wire resolution test, and 0.022 inch wire should be seen at moving wire resolution test.

A Study on the Improvement for Sensitivity Test of Flame Detectors (불꽃화재감지기의 시험기준 개선에 관한 연구)

  • Baek, Dong-Hyun
    • Fire Science and Engineering
    • /
    • v.28 no.6
    • /
    • pp.58-61
    • /
    • 2014
  • Flame detectors has been used more than heat & smoke detector, because this is more effective to catch fire and ceiling height in spite of high price. For upgrade to flame detector, Compare to national or abroad standard about performance test, sensitivity test, sectioning indoor or outdoor, after service and management. As a result, Europe and America have only sensitivity test, no have not operation test and sectioning indoor & outdoor. In performance test, action is put to focus to credit and durability, Not operation test is to be able to tune the sensitivity to match the environment of the site. Also, we need code about aftercare, quality assurance responsibility and implement special detector institution by Certificate Authority implement.

Performance requirement and Evaluation of Natural Smoke Exhaust Ventilator for High rise building (고층건물용 배연창의 성능기준 및 시험평가연구)

  • Kwark, Ji-Hyun;Choi, Jung-Min;An, Byung-Ho;Kim, Bum-Kyue;Park, Yong-Hwan
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2009.04a
    • /
    • pp.129-138
    • /
    • 2009
  • 화재발생시 가장 주요한 사망원인인 유독가스의 제어와, 소방관의 소화활동을 돕기 위한 제연설비는 각 구성품이 유기적으로 동작하는 시스템을 이루기 때문에 전체의 조화도 중요하지만, 기본적으로 각 설비요소가 제 기능을 발휘할 때 전체 시스템의 제연성능을 확보할 수 있게 된다. 그러나 현재 법으로 규정된 국내기준은 주요 구성품별 성능을 제대로 평가할 수 있는 방법 및 기준이 없어 본 연구를 통하여 배연창의 성능평가기술을 개발하고 항목별 성능시험을 실시하여 평가방법의 적합성을 검토하고 국가표준을 만들기 위한 기초 자료로 제공하고자 한다.

  • PDF

Test Methode & kind of Equipment Verification for Control System (제어시스템의 기기검증 시험 종류와 시험방법)

  • Park, Doo-Yong;Lim, Ik-Hun;Lim, Geon-Pyo
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.1786-1787
    • /
    • 2011
  • 화력발전소에 사용되는 제어시스템을 개발함에 있어 하드웨어 분야는 시스템의 안정성과 신뢰성 확보를 위해 반드시 기기검증시험을 통과한 후 적용하여야 한다. 이러한 시험은 제어모듈의 모든 종류의 개별 시험과 실제 사용하고자 하는 구성으로 캐비닛에 모두 장착한 상태에서 시험하여야 한다. 이번 시험은 제어시스템을 설계하고 제작한 후 설계 제원대로 성능을 가지고 있는지에 대한 검증을 목적으로 하였으며, 유럽규격의 CE 마크 획득에 필요한 기준으로 시험을 수행한 기준을 설명한다.

  • PDF

자동차 타이어 안전기준의 국제화

  • Song, Yeong-Gi
    • The tire
    • /
    • s.223
    • /
    • pp.11-13
    • /
    • 2005
  • 이 자료는 교통안전공단 자동차성능시험연구소의 "자동차 안전기준국제화 방안 연구"보고서를 바탕으로 자동차 및 타이어 안전기준의 국제화에 관해 정리한 것입니다.

  • PDF

공동주택용 국내.외 감지기의 설치 및 시험 기준 비교

  • Son, Bong-Se;Lee, Chae-Won
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2013.11a
    • /
    • pp.67-68
    • /
    • 2013
  • 본 연구는 국내 전체 화재발생 건수에서 가장 높은 비율을 차지하고 있는 주거공간에 대한 화재 및 인명안전의 개선 대책에 관한 기초연구이다. 주거공간은 다른 어떠한 방호공간보다 가장 높은 수준의 안전이 요구되는 소방대상물이다. 국내의 주거공간을 대표하는 공동주택의 안전을 확보하는데 가장 중요한 역할을 하는 것이 화재감시시스템이며 이를 구성하는 요소 중에서도 감지기의 성능이 가장 중요한 역할을 한다. 감지기의 성능은 인간의 두뇌와 같은 기능을 하기 때문이다. 이미 일본의 경우는 공동주택 전용의 화재감시시스템을 개발하고 기준으로 제정하여 널리 보급하고 있는 실정이다. 또한 미국은 공동주택 전용의 화재감시시스템이 별도로 존재하지는 않지만 화재특성 및 화재하중 등에 대한 시험을 통해 다양한 방호공간을 효율적으로 적용할 수 있도록 상세한 코드가 정립되어 있다. 따라서 본 연구에서는 국내 공동주택에 적합한 전용 화재감시시스템을 개발하는데 필요한 기초 연구로서 국내와 방재선진외국의 감지기 설치 및 성능을 검증하는데 필요한 설치 및 시험 기준에 대하여 조사하였다.

  • PDF