• Title/Summary/Keyword: 성능시험 기준

Search Result 1,040, Processing Time 0.026 seconds

Seismic Behavior of High-Strength Reinforced Concrete Bridge Columns (고강도 철근콘크리트 교각의 내진 거동)

  • Hwang Sun-Kyoung;Lee Chin-Ok;Ryu Hyo-Jin;Yun Hyun-Do;Lim Byung-Hoon
    • Journal of the Korea Concrete Institute
    • /
    • v.17 no.4 s.88
    • /
    • pp.505-511
    • /
    • 2005
  • This experimental investigation was conducted to examine the seismic performance of reinforced concrete bridge columns. The columns were subjected to a constant axial load and a cyclic horizontal load-inducing reversed bending moment. The variables studied in this research were the volumetric ratios of transverse reinforcement (ps=0.96, 1.44 percent) and axial load ratios (P/Po=0.05, 0.1, 0.2) and concrete strengths (35, 60MPa). Test results showed that bridge columns with $44\%$ higher amounts of transverse reinforcement than that required by seismic provisions of ACI 318-02 showed ductile behavior. For bridge columns with axial load ratio(P/Po) less than 0.2, the ratio of $M_{max}\;over\;M_{ACI}$, nominal moment capacity predicted by ACI 318-02 provisions, was consistently greater than 1 with approximately a $20\%$ margin of safety.

Experimental validations of fire-resistant materials for protecting LPG small storage tank from building fires (건물 화재 시 LPG소형저장탱크 보호용 화재 저항 재료 성능 실증)

  • Kim, Seung-Hwan;Kim, Kyung-Sik;Heo, Seung-Geon;Lee, Jae-Hun
    • Journal of the Korean Institute of Gas
    • /
    • v.24 no.4
    • /
    • pp.18-24
    • /
    • 2020
  • The purpose of this study is to validate thermal hinderance effects, i.e., feasibilities, of fire-proof structure for LPG tank exposed to fire from adjacent burning building. The panel materials suggested for the fire-proof structure are (1) 10 mm-thick wood, (2) wood with fireproof coating, (3) 75 mm-thick Expanded Polystyrene, (4) 75 mm-thick glass wool filled sandwich panel, and (5) 75 mm-thick autoclaved lightweight concrete. The square planar fire source of 1 ㎡, a matrix of nozzles releasing 120-140 g/s of LPG, is used to heat up the wall and the tank beyond, mimicking heat transfer from burning exterior wall finishes. The feasibility is tested by inspecting structural integrity after test, and then by examining temperatures at both sides of panels and tank's front surface as well as heat fluxes. As a result, it can be concluded that, among the suggested sample materials, fire-proof wall with ALC panel only showed the feasibility for explosion prevention with the proven evidences of structural integrity and least increase in temperature of tank.

Seismic Performance Evaluation of the Li-Polymer Battery Rack System for Nuclear Power Plant (원자력발전소용 리튬폴리머 배터리 랙 시스템의 내진성능평가)

  • Kim, Si-Jun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.5
    • /
    • pp.13-19
    • /
    • 2019
  • After the Fukushima nuclear accident, a new power supply using a lithium polymer battery has been proposed the first time in the world as the safety of the emergency battery facility has been required. It is required to have the safety of the rack system in which the battery device is installed in order to apply the proposed technology to the field. Therefore, the purpose of this study is to evaluate the seismic performance of string and rack frame for lithium-polymer battery devices developed for the first time in the world to satisfy 72 hours capacity. (1) The natural frequency of the unit rack system was 9 Hz, and the natural frequency before and after the earthquake load did not change. This means that the connection between members is secured against the design earthquake load. (2) he vibration reduction effect by string design was about 20%. (3) As a result of the seismic performance test under OBE and SSE conditions, the rack frame system was confirmed to be safe. Therefore, the proposed rack system can be applied to the nuclear power plant because the rack system has been verified structural safety to the required seismic forces.

Acoustic outputs from clinical ballistic extracorporeal shock wave therapeutic devices (임상에서 사용중인 탄도형 체외충격파 치료기의 음향 출력)

  • Cho, Jin Sik;Kwon, Oh Bin;Jeon, Sung Joung;Lee, Min Young;Kim, Jong Min;Choi, Min Joo
    • The Journal of the Acoustical Society of Korea
    • /
    • v.41 no.5
    • /
    • pp.570-588
    • /
    • 2022
  • We scrutinized the acoustic outputs from the 70 shock wave generators of the 15 product models whose technical documents were available, among the 46 ballistic extracorporeal shock wave therapeutic devices of 11 domestic and 6 foreign manufacturers, approved by the Minster of Food & Drug Safety (Rep. Korea). We found that the acoustic Energy Flux Density (EFD), the most popular exposure parameter, was different by up to 563.64 times among shock wave generators at their minimum output settings and by up to 74.62 times at their maximum settings. In the same product model, the EFD was shown to vary depending on shock wave transmitters by up to 81.82 times at its minimum output setting and by up to 46.15 times at its maximum setting. The lowest EFD 0.013 mJ/mm2 at the maximum output settings was much lower (2.1 %) than the maximum value 0.62 mJ/mm2 at the minimum settings. The Large acoustic output differences (tens to hundreds of times)from the therapeutic devices approved for the same clinical indications imply that their therapeutic efficacy & safety may not be assured. The findings suggest the regulatory authority to revise her guideline to give clearer criteria for clinical approval and equality in performance, and recommend the authority to initiate a post-approval surveillance as well as a test in conformance between the data in technical documents and the real acoustic outputs clinically used.

Investigation of the listening environment for lower grade students in elementary school using subjective tests (주관적 평가법을 이용한 초등학교 저학년 교실의 청취환경 조사)

  • Park, Chan-Jae;Haan, Chan-Hoon
    • The Journal of the Acoustical Society of Korea
    • /
    • v.40 no.3
    • /
    • pp.201-212
    • /
    • 2021
  • The present study was conducted as a pilot investigation to suggest the standards of acoustic performance for classrooms suitable for incomplete hearing people such as children under 9 years of age. Subjective evaluations such as questionnaire and speech intelligibility test were conducted to 264 students at two elementary schools in Cheong-ju in order to analyze the characteristics of the listening environment in the classrooms of the lower grades in elementary school. The survey was undertaken with a total of 264 students at two elementary schools in Cheong-ju, and investigated their satisfaction with the classroom listening environment. As a result, students responded that the most helpful information type for understanding class content is the voice of teacher. In addition, the volume of the current teacher's voice is normal, and the level of clarity is highly satisfactory. As for the acoustic performance of the classroom, the opinion that the noise was normal and the reverberation was very short was found to be dominant in overall satisfaction with the listening environment. Meanwhile, as a result of speech intelligibility test using the word list selected for the lower grade students of elementary school, it could be inferred that the longitudinal axis distance from the sound source in the case of 8-year-olds is a factor that affects speech recognition.

Effect of Loading Rate on Self-stress Sensing Capacity of the Smart UHPC (하중 속도가 Smart UHPC의 자가 응력 감지 성능에 미치는 영향)

  • Lee, Seon Yeol;Kim, Min Kyoung;Kim, Dong Joo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.5
    • /
    • pp.81-88
    • /
    • 2021
  • Structural health monitoring (SHM) systems have attracted considerable interest owing to the frequent earthquakes over the last decade. Smart concrete is a technology that can analyze the state of structures based on their electro-mechanical behavior. On the other hand, most research on the self-sensing response of smart concrete generally investigated the electro-mechanical behavior of smart concrete under a static loading rate, even though the loading rate under an earthquake would be much faster than the static rate. Thus, this study evaluated the electro-mechanical behavior of smart ultra-high-performance concrete (S-UHPC) at three different loading rates (1, 4, and 8 mm/min) using a Universal Testing Machine (UTM). The stress-sensitive coefficient (SC) at the maximum compressive strength of S-UHPC was -0.140 %/MPa based on a loading rate of 1 mm/min but decreased by 42.8% and 72.7% as the loading rate was increased to 4 and 8 mm/min, respectively. Although the sensing capability of S-UHPC decreased with increased load speed due to the reduced deformation of conductive materials and increased microcrack, it was available for SHM systems for earthquake detection in structures.

Analysis of LDC Message Reception Performance of Korean eLoran Pilot Service according to Modulation Methods (첨단 지상파항법시스템(eLoran) 시범서비스의 LDC 메시지 변조기법에 따른 수신성능 분석)

  • Pyo-Woong, Son;Sak, Lee;Tae Hyun, Fang;Kiyeol, Seo
    • Journal of Navigation and Port Research
    • /
    • v.46 no.6
    • /
    • pp.525-529
    • /
    • 2022
  • In the eLoran system, the Loran Data Channel (LDC) is used to provide precise timing and positioning. The LDC message can be modulated with the Eurofix method, which modulates the transmission time of the 3rd-8th pulse not used for navigation, and the 9th pulse method, which modulates data using the 9th additional pulse after the existing 8 Loran pulses. In this paper, we analyzed the reception performance of the LDC message transmitted from the eLoran transmitter according to the modulation method. The eLoran testbed transmitter in Incheon was set to transmit LDC messages simultaneously with the 9th pulse modulation method and the Eurofix modulation method. Then, the LDC messages stored in the databases of the eLoran differential stations in Incheon and Pyeongtaek were analyzed in terms of the message reception rate according to the modulation method. Using the navigation aid management ship Inseong No. 1, the range of LDC message reception of actual sea users near Incheon Port was also analyzed. The results of this study are expected to be utilized in the full operational capability service after the eLoran pilot service.

Design and Implementation of User-Level FileSystem in the Combat Management System

  • Kang, Seok-Hyun;Kim, Keun-Hee
    • Journal of the Korea Society of Computer and Information
    • /
    • v.27 no.12
    • /
    • pp.9-16
    • /
    • 2022
  • In this paper, we propose a plan to design and utilize the RDBS(Record Block Data file management System) so that data can be recovered when data files in the Combat Management System are mismatched. The CMS(Combat Management System) manages the same files in multiple IPN(Infomation Processing Node) repositories to support multiplexing. However, mismatches in data files can occur due to equipment maintenance or user immaturity. The existing CMS does not manage the history of changes in data files, and when a mismatch occurs, data file were synchronized based on the latest date. But, It is difficult to say that files with the latest date have the highest reliability, and once the file synchronization has progressed, it cannot be recovered with pre-synchronization data. To solve this problem, data was stored and synchronized in units of record blocks using RDBS proposed in this paper, and the Rsync algorithm was used to reduce the overhead of file synchronization due to units of record blocks. SW applied with RDBS was tested for performance in a simulated environment, and it was confirmed that it could be applied to CMS through normal operation confirmation.

Risk Assessment of Smoke Generated During Combustion for Some Wood (일부 목재의 연소 시 발생되는 연기의 위험성 평가)

  • Chung, Yeong-Jin;Jin, Eui
    • Applied Chemistry for Engineering
    • /
    • v.33 no.4
    • /
    • pp.373-380
    • /
    • 2022
  • In this study, Chung's equations 1, 2, and 3 were extended to standardize smoke safety rating evaluation in case of fire, and Chung's equations-V, smoke performance index-V, and smoke growth index-V were calculated. Five types of wood were selected and their smoke indices were measured using the cone calorimeter method according to ISO 5660-1. The smoke risk was graded by the smoke risk index-VI according to Chung's equation-VI. Smoke risk index-VI increased in the order of PMMA (1) ≈ maple (1.01) < ash (1.57) < needle fir (4.98) < paulownia (46.15) < western red cedar (106.26). It was predicted that maple and ash had the lowest smoke risk, and paulownia and western red cedar had the highest. The five samples' CO mean production rate (COPmean) was 0.0009~0.0024 g/s, indicating that these woods were incompletely burned than the polymethyl methacrylate (PMMA) reference material. Regarding the smoke properties of the chosen woods, the smoke performance index-V (SPI-V) increased as the bulk density increased, and the smoke risk index-VI (SRI-VI) decreased.

A review on the previously performed hydraulic experiments of bank protection materials (기 수행된 호안재료 수리 검토 실험에 관한 고찰)

  • Chanjoo Lee;Myeonghwan Kim;Sungjung Kim;Muyoung Na
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2023.05a
    • /
    • pp.297-297
    • /
    • 2023
  • 최근 친수성, 경관, 생태계 보전 등을 위해 다양한 호안블록의 시공이 이루어지고 있어 호안블록의 수리적 안정성에 관한 관심이 증가하고 있다. 이러한 배경 하에 한국건설기술연구원 안동하천실험센터(이하 센터)에서는 2019년부터 실규모 수로를 이용하여 여러 건의 호안블록 실규모 수리검토 실험을 실시한 바 있다. 본 연구는 그간의 실험 결과를 종합적으로 고찰하고 수리 검토 실험의 현황과 한계점, 그리고 개선 방향을 제언하는데 그 목적이 있다. A1 수로(급경사수로, 하상경사 1/70)에서는 7건(21회), B1 수로(고유속수로, 하상경사 1/7)에서는 2건(6회)의 실험이 수행되었다. A1 수로 실험의 유량-소류력 관계는 1.0 m3/s에서 약 20 N/m2이며, 1.0 m3/s 증가당 약 11 N/m2이 증가하는 관계를 나타낸다. 7건의 실험 결과 30분 이상 지속된 최대 실험 유량은 6~7 m3/s 정도이며, 이는 A1 최대 공급 유량의 75 % 정도로서 안정적인 수준이라고 판단된다. 이 때의 최대 소류력은 75 N/m2 정도로 나타났다. B1 수로는 5 m/s 이상의 고유속 흐름을 발생시킬 수있으며, 2건의 실험 결과 0.5 m3/s에서 약 100 N/m2, 최대 4.5 m3/s에서 330 N/m2까지 소류력을 제공하여 실험을 수행한 바 있다. 따라서 A1, B1 수로를 통해 제공할 수 있는 소류력 범위는 10~330 N/m2이지만, 75~100 N/m2는 실험에서 제공된 바 없었다. 한편, 토양유실의 경우 수준측량에 의해 측정되는데, 대부분의 실험에서 Clopper의 토양손실 지수(1.27 cm) 미만의 결과가 발생하였다. 이는 시험체에 따라 여건이 다르기는 하지만, 수리 검토 실험시 3회 실험을 기본으로 하고 있고 호안재료의 침식이 기준 이하로 유지되면서 최대한의 성능을 발휘할 수 있는 소류력 조건을 얻으려는 실험 목적에 부합하도록 조절된 것으로 볼 수 있다. 이러한 실험 결과를 토대로 고려해볼 수 있는 개선 방향은 다음과 같다. 강성 재료가 아닌 연성 또는 친환경적 호안재료의 허용 소류력 범위를 보다 넓게 평가하기 위해 A1 수로가 제공하는 최대 소류력을 높일 필요가 있다. 이를 위해 기본 3회의 실험 외에 추가로 호안블록이 파괴되거나 토양유실 임계치를 초과할 수 있는 실험을 수행함으로써 각 제품의 한계 성능을 평가하는 것이 필요할 것으로 보인다.

  • PDF