• Title/Summary/Keyword: 성능검사

Search Result 1,361, Processing Time 0.029 seconds

Performance Comparison of Pipeline Defects' Length Estimation Using MFL Signals (자기 누설 신호를 이용한 배관 결함의 길이 추정 성능 비교)

  • Kim, Tae-Wook;Rho, Yong-Woo;Choi, Doo-Hyun
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.29 no.2
    • /
    • pp.108-113
    • /
    • 2009
  • MFL(magnetic flux leakage) inspection is a general method of non-destructive evaluation(NDE) of underground gas pipelines. Pipelines are magnetized by permanent magnets when MFL PIG(pipeline inspection gauge) gets through them. If defects or corrosions exist in pipelines, effective thickness is changed and thus variation of leakage flux occurs. The leakage flux signals detected by hall-sensors are analyzed to characterize defect's geometries such as length, width, depth, and so on. This paper presents several methods for estimating defect's length using MFL signals and their performances are compared for real defects carved in KOGAS pipeline simulation facility. It is found that 80% and 90% of minimum values for axial and peak values for radial signals respectively show the best performance in the point of length estimation error.

Development of a High speed Actuator for electric performance testing System of ceramic chips (세라믹칩 전기적 성능검사 시스템을 위한 고속구동 액튜에이터 개발)

  • Bae, Jin-Ho;Kim, Sung-Gaun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.4
    • /
    • pp.1509-1514
    • /
    • 2011
  • The core of IT products, electronic components, especially the MLCC, chip inductors, chip Varistors and so on. In order to test the electrical characteristics of the chip using the Reno-pin contact test method has been used. In current chips, mass production of semiconductor manufacturing processes, high-speed production test for the chip speed up, precision is required. But Vibration displacement is a very short, so in order to overcome these shortcomings, the displacement amplification to design the structure has been actively studied. In this paper, a building structure with a flexible hinge was designed amplification instrument, semiconductor chip industry in the performance test and inspection equipment to measure the electrical characteristics of high speed linear actuators Reno-Pin using system was developed.

Performance Analysis of RS, Turbo and LDPC Code in the Binary Symmetric Erasure Channel (이진 대칭 소실 채널에서 RS, 터보 및 저밀도 패리티 검사 부호의 성능 분석)

  • Lim, Hyung-Taek;Park, Myung-Jong;Kang, Seog-Geun;Joo, Eon-Kyeong
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.35 no.2C
    • /
    • pp.219-228
    • /
    • 2010
  • In this paper, performance of RS (Reed-Solomon), turbo and LDPC (low density parity check) code in the binary symmetric erasure channel is investigated. When the average erasure length is reduced, the frequency of short erasures is increased. The RS code shows serious performance degradation in such an environment since decoding is carried out symbol-by-symbol. As the erasure length is increased, however, the RS code shows much improved en-or performance. On the other hand, the message and corresponding parity symbols of the turbo code can be erased at the same time for the long erasures. Accordingly, iterative decoding of the turbo code can not improve error performance any more for such a long erasure. The LDPC code shows little difference in error performance with respect to the variation of the average erasure length due to the virtual interleaving effect. As a result, the LDPC code has much better erasure decoding performance than the RS and turbo code.

Study of Aging and Performance About Separation Devices Has Been Stored (장기 보관된 분리장치의 성능 및 노화에 관한 연구)

  • Kim, Dong-seong;Jin, Hong-Sik
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.49 no.7
    • /
    • pp.565-572
    • /
    • 2021
  • In this study, a study on the performance and aging of explosive bolts stored for a long time among pyrotechnic mechanical devices(PMD) used as separation devices in the defense field is conducted. For this, explosive bolts that had been installed in the weapon system for about 10 years are secured. Performance and life extension test procedures are established based on the AIAA Standard and MIL-STD. Before performance evaluation, non-functional tests are performed to check whether external changes or failures occurred. Next, circuit inspection and X-ray tests are conducted to check the failure in internal circuits and structures. After that, performance test is carried out to confirm the operation of the samples that passed the non-functional test. Through this test, separation of bolt and separation time are measured, and some samples are tested after a high temperature storage test to confirm the remaining life and the possibility of extension. Finally, the remaining life and reliability are predicted based on the results of the test and the Arrhenius model to identify remaining shelf life and reliability depend on time.

표지선 주기관 개방검사 면제에 대한 고찰 < 기관(ENG') 개방검사 면제로 11억원을 벌다! >

  • Kim, Hyeong-Jun;Song, Mun-Cheol;No, Gyeong-Sik
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2018.11a
    • /
    • pp.81-82
    • /
    • 2018
  • 선박안전법에 따라 대다수의 관공선 주기관은 8년마다 정기 개방검사를 해야 한다. 주기관 특성상 개방검사는 많은 예산 소요 및 엔진 효율성의 저하가 우려되어 이를 해결하고자 관련법에 따라 8년간 개방검사 면제 사전 준비로 예산을 절감하고 기관의 성능을 최적화 시켰다.

  • PDF

Image Matching Techniques for Electronic Component Inspection (전자부품조립검사를 위한 영상 정합 방법 비교)

  • Cho, Han-Jin;Park, Tae-Hyoung
    • Proceedings of the KIEE Conference
    • /
    • 2007.10a
    • /
    • pp.335-336
    • /
    • 2007
  • 본 논문은 표면실장기판을 위한 자동 광학 검사 시스템에서 사용되는 알고리즘을 종류 별로 비교 분석한다. 비교된 부품 검사 알고리즘은 공간영역에서의 템플릿 매칭 방법을 사용한다. 각 방법에는 장단점이 있으며 주된 비교항목은 검사 속도와 검사 정확도에 대한 비교 분석을 한다. 비교 및 분석을 통해 부품검사 알고리즘의 속도 및 정확도 향상의 방향을 제시한다. 실험 결과를 제시하여 비교된 알고리즘의 성능을 검증한다.

  • PDF

Improvement of Diagnostic Accuracy by Standardization in Diuretic Renal Scan (소아 이뇨 신장스캔에서 검사 표준화에 의한 폐쇄 진단 성능 향상)

  • Hyun, In-Young;Lee, Dong-Soo;Lee, Kyung-Han;Chung, June-Key;Lee, Myung-Chul;Koh, Chang-Soon;Kim, Kwang-Myung;Choi, Hwang;Choi, Yong
    • The Korean Journal of Nuclear Medicine
    • /
    • v.29 no.4
    • /
    • pp.497-503
    • /
    • 1995
  • We evaluated diagnostic accuracy of diuretic renal scan with standardization in 45 childrens(107 hydronephrotic kidneys) with 91 diuretic assessments. Sensitivity was 100%, specificity was 78%, and accuracy was 84% in 49 hydronephrotic kidneys with standardization. Diuretic renal scan without standardization, sensitivity was 100%, specificity was 38%, and accuracy was 57 % in 58 hydronephrotic kidneys. The false-positive results were observed in 25 cases without standardization, and in 8 cases with standardization. In diuretic renal scans without standardization, the causes of false-positive results were 10 early injection of lasix before mixing of radioactivity in pelvocalyceal system, 4 full bladder, 2 markedly dilated pelvocalyceal systems postpyeloplsty, 6 extrarenal pelvis, and 3 immature kidneys of neonates. In diuretic renal scans with standardization the causes of false-positive results were 2 markedly dilated systems postpyeloplsty, 2 extrarenal pelvis, 1 immature kidney of neonate, and 2 severe venal dysfunction, 1 vesicoureteral reflux. In diuretic renal scan without standardization the false-positive results by inadequate study were common, but false-positive results by inadequate study were not found after standardization. The false-positive results by dilated pelvocalyceal systems postpyeloplsty, extrarenal pelvis, and immature kidneys of neonates were not dissolved after standardization. In conclusion, diagnostic accuracy of diuretic renal scan with standardization was useful in children with renal outflow tract obstruction by improving specificity significantly.

  • PDF

Improvement of Korean Grammar Checker Using Partial Parsing based on Dependency Grammar and Disambiguation Rules (어휘적 중의성 제거 규칙과 부분 문장 분석을 이용한 한국어 문법 검사기 성능 향상)

  • So, Kil-Ja;Nam, Hyeon-Sook;Kim, Su-Nam;Won, Sang-Yeon;Kwon, Hyuck-Chul;Park, Dong-In
    • Annual Conference on Human and Language Technology
    • /
    • 1998.10c
    • /
    • pp.253-260
    • /
    • 1998
  • 한국어 문서에는 여러 어절을 검증해야만 처리할 수 있는 의미 오류와 문체 오류가 있다. 다수 어절 사이에 있는 오류는 부분 문장 분석을 한다. 논문에서는 의미 오류와 문체 오류를 처리할 때 어휘적 중의성 때문에 생기는 문제점을 제시하고 해결방법을 제안한다. 어휘적 중의성이란 한 단어가 두 가지 이상의 형태소 정보를 가짐을 뜻한다. 철자검사기와는 달리 문법 검사기에서는 어휘적 중의성을 제거하지 않으면 여러 가지 검사 오류가 발생한다. 이 논문에서는 의미, 문체 시스템에서 어휘적 중의성 때문에 검사 오류가 발생할 수 있는 과정을 크게 세 단계로 분류하였다. 연어 오류가 발생할 수 있는 검사단어가 어휘적 중의성을 가지면 표제어가 다른 규칙이 여러 개 존재한다. 이 때 규칙 선택 문제가 생긴다. 중의성 문제는 부분 문장분석 과정에서도 지배소와 의존소 사이의 의존관계를 정확하게 설정하기 어렵게 한다. 본 논문에서는 각 단계에서 발생한 문제를 최소화하여 문법 검사기의 성능을 향상시킨다.

  • PDF

The Hybrid Fault Tolerant Technique for Embedded System (임베디드 시스템을 위한 복합 결함 허용 기법)

  • Kook, Joong-Jin;Hong, Ji-Man
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2007.06b
    • /
    • pp.273-278
    • /
    • 2007
  • 검사점 및 복구 도구(Checkpointing & Recovery Facility)를 이용하여 임베디드 시스템에서 결함 허용(Fault Tolerance) 기법을 적용할 경우 쓰기 작업의 오버헤드로 인해 실용성이 크게 떨어지게 된다. 실시간 운영체제와 함께 어떠한 한계 상황에서 결함 허용 및 복구 도구가 오히려 시스템의 성능을 저하시키는 요인으로 작용하게 되면 이는 결국 쓸모없는 도구가 되어 사용되지 않을 것이다. 따라서 프로세스의 복구를 위해 저장하는 프로세스 이미지의 기록에 소요되는 시간을 크게 낮추어야만 비로소 검사점 도구가 그 진가를 발휘하게 될 수 있다. 본 논문에서는 NVSRAM(Non Volatile SRAM)을 검사점 및 복구 도구의 저장 장치로 활용함으로써 기존의 검사점 도구에서 성능을 저하시키는 주원인이었던 검사점 기록의 오버헤드를 개선하기 위한 연구를 수행하였다. 검사점 기록 시간을 줄이기 위한 방법으로 주 메모리에 저장된 프로세스의 복구와 관련된 데이터를 SRAM 특성을 갖는 비휘발성 저장 장치인 NVSRAM에 저장하여 디스크 접근에 소요되는 시간을 최소화시킴으로써 임베디드 시스템에서 실용적으로 사용 가능한 검사점 도구를 구현하였고, 이러한 연구의 결과를 검증하기 위해 기존 시스템에서 저장 장치로 사용되던 플래시 메모리, 주 메모리, 원격 메모리를 사용하는 경우의 성능과 NVSRAM을 활용할 때의 성능을 비교해 보았다. 본 연구에서 제안하는 결함 허용 도구는 실제 시스템에 적용하여 효과적인 성능을 발휘할 수 있을 것이며, 차세대 메모리를 이용한 결함 허용 도구의 연구에 기여를 할 수 있을 것으로 기대된다.ate첨가배지(添加培地)에서 가장 저조(低調)하였다. vitamin중(中)에서는 niacin과 thiamine첨가배지(添加培地)에서 근소(僅少)한 증가(增加)를 나타내었다.소시켜 항이뇨 및 Na 배설 감소를 초래하는 작용과, 둘째는 신경 경로를 통하지 않고, 아마도 humoral factor를 통하여 신세뇨관에서 Na 재흡수를 억제하는 작용이 복합적으로 나타내는 것을 알 수 있었다.으로 초래되는 복합적인 기전으로 추정되었다., 소형과와 기형과는 S-3에서 많이 나왔다. 이상 연구결과에서 입도분포가 1.2-5mm인 것이 바람직한 것으로 나타났다.omopolysaccharides로 확인되었다. EPS 생성량이 가장 좋은 Leu. kimchii GJ2의 평균 분자량은 360,606 Da이었으며, 나머지 두 균주에 대해서는 생성 EPS 형태와 점도의 차이로 미루어 보아 생성 EPS의 분자구조와 분자량이 서로 다른 것으로 판단하였다.TEX>개로 통계학적으로 유의한 차이가 없었다. Heat shock protein-70 (HSP70)과 neuronal nitric oxide synthase (nNOS)에 대한 면역조직화학검사에서 실험군 Cs2군의 신경세포가 대조군 12군에 비해 HSP70과 nNOS의 과발현을 보였으며, 이는 통계학적으로 유의한 차이를 보였다(p<0.05). nNOS와 HSP70의 발현은 강한 연관성을 보였고(상관계수 0.91, p=0.000), nNOS를 발현하는 세포가 동시에 HSP70도 발현함을 확인할 수 있었다. 결론: 우리는 cyclosporin A가 토끼의 25분간의 척수허혈에 대해 척수보호 효과가 있었으며 이는 HSP70의

  • PDF

Implementation of ATE to Maintain Pre-Amplifier of Thermal Imaging System (열상장비 전단증폭부 정비용 ATE의 구현)

  • Park, Jai-Hyo;Kim, Han-Kyung
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.49 no.1
    • /
    • pp.80-87
    • /
    • 2012
  • We have developed the ATE(Automatic Test Equipment) system for the performance test of pre-amplifier of thermal imaging devices. The device regenerates the electronic signals of photon detection module which is normally in weak energy, for the image signals processing. Previous ATE system was primarily and actively developed in the field of semiconductor devices quality parts inspection. Recently, it has been studied in the field of performance testing of equipment. In the field of thermal performance test equipment, however, it lacks the study of ATE compared to other areas, which causes the maintenance related to the core of military thermal imaging system maintenance to be limited. In this paper, a new study of ATE in the field of thermal imaging system is done. It is designed to be used universally for the ATE system with different types of circuit card of thermal imaging system by adopting matrix relays. Using the developed ATE measuring the pre-amplifier amplitude, an average amplified amplitude of 2.71Vpp was measured which confirms that it is within the range of theoretical analysis and also verifies the good performance of the developed ATE.