• Title/Summary/Keyword: 섬광법

Search Result 88, Processing Time 0.029 seconds

Experimental Analysis of Bubble Dynamics Induced by Pulsed-Laser Heating of Absorbing Liquid (흡광 액체의 펄스 레이저 가열에 의해 생성된 기포 거동의 실험적 해석)

  • Jang Deok-Suk;Hong Jong-Gan;Choa Sung-Hoon;Kim Dong-Sik
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.30 no.5 s.248
    • /
    • pp.413-421
    • /
    • 2006
  • The bubble dynamics induced by direct laser heating is experimentally analyzed as a first step to assess the technical feasibility of laser-based ink-jet technology. To understand the interaction between laser light and ink, the absorption spectrum is measured for various ink colors and concentrations. The hydrodynamics of laser-generated bubbles is examined by the laser-flash photography. When an Ar ion laser pulse (wavelength 488 nm) with an output power up to 600 mW is incident on the ink solution through a transparent window, a hemispherical bubble with a diameter up to ${\sim}100{\mu}m$ can be formed with a lifetime in a few tens of microsecond depending on the laser power and the focal-spot size. Parametric study has been performed to reveal the effect of laser pulse width, output power, ink concentration, and color on the bubble dynamics. The results show that the bubble generated by a laser pulse is largely similar to that produced by a thin-film heater. Consequently, the present work demonstrates the feasibility of developing a laser-actuated droplet generation mechanism for applications in ink-jet print heads. Furthermore, the results of this work indicate that the droplet generation frequency is likely to be further increased by optimizing the process parameters.

Visually evoked potential in children with mitochondrial respiratory chain defects (소아 사립체 질환에서 시각 유발전위검사의 유용성)

  • Song, Ji Eun;Kim, He Min;Lee, Sang-Chul;Park, Yoon-Gghil;Byeon, Suk-Ho;Lee, Young-Mock;Lee, Joon-Soo;Kim, Heung-Dong
    • Clinical and Experimental Pediatrics
    • /
    • v.52 no.4
    • /
    • pp.471-475
    • /
    • 2009
  • Purpose : Mitochondrial disorders are a clinical entity characterized by diverse symptoms and signs of involvement of various systems. Furthermore, the disorders are known to show ophthalmologic manifestations as well as neurological findings. Visually evoked potential is a sensitive measure to check the integrity of the visual pathway. In this study, we have investigated the value of visually evoked potential in mitochondrial disorders with respiratory chain defects. Methods : Nineteen patients diagnosed with mitochondrial respiratory chain complex I defect as confirmed by spectrophotometric enzyme assay in muscle samples were enrolled for this study. The patients underwent a visually evoked potential study. We classified the results into four groups and compared these with clinical ophthalmologic findings. Results : Among the 19 patients, 14 showed abnormal visually evoked potential findings. Seven patients showed abnormal clinical ophthalmologic findings. All patients with abnormal ophthalmologic findings showed abnormal visually evoked potential findings. Among the 12 patients with normal ophthalmologic findings, seven showed abnormal results in visually evoked potential. Conclusion : Visually evoked potential study could be used as an effective screening tool for mitochondrial disorders to detect ophthalmologic and neurological abnormalities.

Neutron Capture Resonance Energy Identification of Indium by Time-of-Flight Method (중성자 비행시간법을 이용한 인듐의 공명에너지 동정에 관한 연구)

  • Lee, Sam-Yol
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.5
    • /
    • pp.403-408
    • /
    • 2012
  • Prompt gamma ray from the natural Indium sample was measured by using an assembly of BGO($Bi_4Ge_3O_{12}$) scintillation detectors in the neutron energy region from 1 to 300 eV. The assembly was composed of pieces of BGO. The spectrometer was composed geometrically as total energy absorption detector. 46-MeV electron linear accelerator which is located at Research Reactor Institute, Kyoto University used for neutron sources from photonuclear reaction. The measurement of the neutron capture resonances was performed to below neutron energy 1 keV, because of strong X-ray effect from photonuclear reaction in Ta target and short distance from the target to an assembly of detector. The distance of neutron flight path is $12.7{\pm}0.02m$. The large neutron capture resonances were measured from 1 to 400 eV. The energy in the capture resonance was compared with the evaluated values. The large resonances were seen in the present measurement. General agreement can be seen between the present measurement and the previous evaluated data in relevant energy region. In the present study, we measured the continues resonance structure above 1 keV neutron energy region. 91.49 eV new neutron capture resonance was found in present measurement.

Comparison of the Diagnostic Performance of $^{14}C$-urea Breath Test According to Counting Method for the Diagnosis of Helicobacter pylori Infection (Helicobacter pylori 감염 진단 시 $^{14}C$-요소호기검사의 계수측정 방법에 따른 진단성능 비교)

  • Kim, Min-Woo;Lim, Seok-Tae;Lee, Seung-Ok;Sohn, Myung-Hee
    • The Korean Journal of Nuclear Medicine
    • /
    • v.39 no.1
    • /
    • pp.21-25
    • /
    • 2005
  • Purpose: $^{14}C$-urea breath test (UBT) is a non-invasive and reliable method for the diagnosis of Helicobacter pylori (HP) infection. In this study, we evaluated the diagnostic performance of a new and rapid $^{14}C$-UBT (Heliprobe method), which was equipped with $Geiger-M\ddot{u}ller$ counter and compared the results with those obtained by using the conventional method. Materials and Methods: Forty-nine patients with dyspepsia underwent gastroduodenoscopy and $^{14}C$-UBT. A 37 KBq $^{14}C$-urea capsule was administered to patients and breath samples were collected. In Heliprobe method, patients exhaled into a Hellprobe BreathCard for 10 min. And then the activities of the BreathCard were countered using Heliprobe analyzer. In the conventional method, results were countered using liquid scintillation counter. During gastroduodenoscopy, 18 of 49 patients were underwent biopsies. According to these histologic results, we evaluated the diagnostic performance of two different methods and compared them. Also we evaluated the concordant and disconcordant rates between them. Results: In all 49 patients, concordant rate of both conventional and Heliprobe methods was 98% (48/49) and the discordant rate was 2% (1/49). Thirteen of 18 patients to whom biopsies were applied, were found to be HP positive on histologic results. And both Heliprobe method and conventional method classified 13 of 13 HP-positive patients and 5 of 5 HP-negative patients correctly (sensitivity 100%, specificity 100%, accuracy 100%). Conclusion: The Heliprobe method demonstrated the same diagnostic performance compared with the conventional method and was a simpler and more rapid technique.

A Novel in Vitro Method for the Metabolism Studies of Radiotracers Using Mouse Liver S9 Fraction (생쥐 간 S9 분획을 이용한 방사성추적자 대사물질의 새로운 체외 측정방법)

  • Ryu, Eun-Kyoung;Choe, Yearn-Seong;Kim, Dong-Hyun;Lee, Sang-Yoon;Choi, Yong;Lee, Kyung-Han;Kim, Byung-Tae
    • The Korean Journal of Nuclear Medicine
    • /
    • v.38 no.4
    • /
    • pp.325-329
    • /
    • 2004
  • Purpose: Usefulness of mouse liver S9 fraction was evaluated for the measurement of the metabolites in the in vitro metabolism study of $^{18}F$-labeled radiotracers. Materials and Methods: Mouse liver S9 fraction was isolated at au early step in the course of microsome preparation. The in vitro metabolism studies were tarried out by incubating a mixture containing the radiotracer, S9 fraction and NADPH at $37^{\ciirc}C$, and an aliquot of the mixture was analyzed at the indicated time points by radio-TLC. Metabolic defluorination was further confirmed by the incubation with calcium phosphate, a bone mimic. Results: The radiotracer $[^{18}F]1$ underwent metabolic defluorination within 15 min, which was consistent with the results of the in vivo method and the in vitro method using microsome. Radiotracer $[^{18}F]2$ was metabolized to three metabolites including $4-[^{18}F]fluorobenzoic$ acid within 60 min. It is likely that the one of these metabolites at the origin of radio-TLC was identical with the one that obtained from the in vivo and in vitro (microsome) method. Compared with the in vitro method using microsome, the method using S9 fraction gave a similar pattern of the metabolites but with a different ratio, which can be explained by the presence of cytosol in the S9 fraction. Conclusion: These results suggest that the findings of the in vitro metabolism studies using S9 fraction can reflect the in vivo metabolism of novel radiotracers in the liver. Moreover, this method can be used as a tool to determine metabolic defluorination along with calcium phosphate absorption method.

Scintillation Characteristics of CsI(Li) Single Crystals (CsI(Li) 단결정의 섬광특성)

  • Lee, W.G.;Doh, S.H.;Ro, T.I.;Kim, W.;Kang, H.D.;Moon, B.S.
    • Journal of Sensor Science and Technology
    • /
    • v.8 no.5
    • /
    • pp.359-367
    • /
    • 1999
  • CsI(Li) single crystals doped with 0.02, 0.1, 0.2 and 0.3 mole% lithium as an activator were grown by Czochralski method. The lattice structure of grown CsI(Li) single crystal was bcc, its lattice constant was $4.568\;{\AA}$. The absorption edge of CsI(Li) single crystal was 245 nm, and the spectral range of luminescence was $300{\sim}600\;nm$, its maximum luminescence intensity appeared at 425 nm. The energy resolutions of CsI(Li) single crystal doped with 0.2 mole% lithium were 14.5% for $^{137}Cs$(662 keV), 11.4% for $^{54}Mn$(835 keV) and 17.7% and 7.9% for $^{22}Na$(511 keV and 1275 keV), respectively. The relation formula of $\gamma$-ray energy versus energy resolution was ln (FWHM%) = -0.893lnE + 8.456 and energy calibration formula was ${\log}E_r=1.455\;{\log}(ch.)-1.277$. The phosphorescence decay time of CsI(Li) crystal doped with 0.2 mole% lithium was 0.51 s at room temperature, and its time resolution measured by CFT(constant-fraction timing method) was 9.0 ns.

  • PDF

Simultaneous Separation and Determination of $^{l4}C\;and\;^3H$ in Spent Resins from PWR Nuclear Power Plants (가압경수로형 원전에서 발생된 폐수지의 $^{14}C$$^3H$ 동시 분리 및 측정)

  • Park, Soon-Dal;Kim, Jung-Suck;Kim, Jong-Goo;Han, Sun-Ho;Jee, Kwang-Yong
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.5 no.3
    • /
    • pp.179-188
    • /
    • 2007
  • In this work $^{14}C\;and\;^3H$ distribution characteristics of spent resins from nuclear power plants(NPPs), pressurized water reactors(PWRs), was investigated. It was found that the recovery percent of $^{14}C$ by the wet oxidation-acid stripping was $81%{\sim}100%$ for the added activity range of $^{14}C,\;0.72\;Bq{\sim}460\;Bq$, and it was not affected by the kinds of stripping acids, 3N-HCl, $3\;N-HNO_3\;and\;3\;N-H_2SO_4$. And the recovery percent of $^3H$ by distillation using the same apparatus was $81%{\sim}101%$ for the added activity range of $^3H,\;0.60\;Bq{\sim}435\;Bq$. Among the tested stripping acids, 3\;N-HCl, $3\;N-HNO_3\;and\;3\;N-H_2SO_4$, only the trapped $^3H$ solution by distillation in $3\;N-H_2SO_4$ was compatible with the 3H scintillator, Ultimagold XR. Neither of the $^{14}C\;and\;^3H$ trapping solutions from the spent ion exchange resin samples by the wet oxidation-3 $N-H_2SO_4$ stripping contained gamma nuclides. However, some gamma nuclides, $^{60}Co,\;^{134}Cs,\;^{137}Cs\;and\;^{54}Mn$, were found in the trapped $^3H$ solutions of the spent resins by the wet oxidation-3 N-HCl stripping. It was the same for the $^3H$ trapping solutions of the spent resins by Sample Oxidizer(PACKARD MODEL 307). Meanwhile only two nuclides, $^{134}Cs,\;and\;^{134}Cs$, were found in the $^{14}C$ trapping solutions of the spent resins by Sample Oxidizer(PACKARD MODEL 307). It was found that most of the $^{14}C$ in the spent resins existed as inorganic carbon form, more than about 70% of the total $^{14}C$ content. Among the analyzed 30 spent ion exchange resin samples, the average concentration of $^{14}C$ and $^3C$ for the high radioactive samples, 8 samples, was $19000\;Bq/g{\pm}41000\;Bq/g,\;670\;Bq/g{\pm}460\;Bq/g$ and that for the low radioactive samples, 22 samples, was $4.2\;Bq/g{\pm}4.3\;Bq/g,\;6.0\;Bq/g{\pm}5.3\;Bq/g$, respectively. And the average $^{14}C/^3H$ ratio for the high radioactive samples, was higher, 28, than that of low radioactive samples, 0.70. Some linear relationship trend was found between the activity concentrations of $^{14}C\;and\;^3H$.

  • PDF

Assessment of Natural Radiation Exposure by Means of Gamma-Ray Spectrometry and Thermoluminescence Dosimetry (감마선분광분석(線分光分析) 및 열형광검출법(熱螢光檢出法)에 의한 자연방사선(自然放射線)의 선량측정연구(線量測定硏究))

  • Jun, Jae-Shik;Oh, Hi-Peel;Choi, Chul-Kyu;Oh, Heon-Jin;Ha, Chung-Woo
    • Journal of Radiation Protection and Research
    • /
    • v.10 no.2
    • /
    • pp.96-108
    • /
    • 1985
  • A study for the assessment of natural environmental radiation exposure at a flat and open field of about $10,000m^2$ in area in CNU Daeduk campus has been carried out by means of gamma-ray scintillation spectrometry and thermoluminescence dosimetry for one year period of time from October 1984. The detectors used were 3'${\phi}{\times}$3' NaI(T1) and two different types of LiF TLD, namely, chip sealed in plastic sheet which tightly pressed on two open holes of a metal plate and Teflon disk. Three 24-hour cycles of in-situ spectrometry, and two 3-month and one 1-month cycles of field TL dosimetry were performed. All the spectra measured were converted into exposure rate by means of G(E) opertaion, and therefrom exposure rate due to terrestrial component of environmental radiation was figured out. Exposure rate determined by the spectrometry was, on average, $(10.54{\pm}2.96){\mu}R/hr$, and the rates of $(12.0{\pm}3.4){\mu}R/hr$ and $(11.0{\pm}3.6){\mu}R/hr$ were obtained from chip and disk TLD, respectively. Fluctuations in diurnal variation of the exposure rate measured by the spectrometry were noticeable sometime even in a single cycle of 24 hours. It is concluded that appropriately combined use of TLD with iu-sitn gamma-ray spectrometry system can give more accurate and precise measure of environmental radiation exposure, and further study for more adequate and sensitive TLD for environmental dosimetry, including improvement and elevation of accuracy in data assessment through inter-laboratory or international intercomparison is necessary.

  • PDF