Study on the test results of ITER CS superconducting magnet power supply (ITER CS 초전도 코일 전원장치 시험 결과에 대한 고찰)

  • Song, Inho;Choi, Jungwan;Seo, Jae Hak;Shin, Hyun Kook;Oh, Jong-Seok
    • Proceedings of the KIPE Conference
    • /
    • 2019.11a
    • /
    • pp.130-131
    • /
    • 2019
  • 국제 핵융합실험로(ITER)를 위해 한국이 제작, 시험, 설치 및 시운전을 하기로 되어 있는 CS(Central Solenoid) 초전도 자석용 전원장치의 시험 및 그 결과에 관하여 논의하고자 한다. 토카막 운전에서 플라즈마 발생 및 제어를 위한 대전류, 고전압, 270 kA 단락 용량 및 4상한 운전 특성을 갖는 45 kA/1050 V의 12펄스 싸이리스터 AC/DC 컨버터 및 제어기를 제작완료하였으며, ITER 부지로 운송하기 전에 공장의 전원 및 부하용량을 고려하여 시험절차서를 개발하였으며, 공장시험(FAT, Factory Acceptance Test)를 진행하였다.

  • PDF

Parallel Operation Algorithm of UPS Considering Line Impedance (선로임피던스를 고려한 200kVA 모듈형 UPS의 병렬 운전 알고리즘)

  • Ahn, Chang-Hoen;Jang, Ju-Hyeong;Lim, Seung-Beom;Kim, Ji-Soo
    • Proceedings of the KIPE Conference
    • /
    • 2017.07a
    • /
    • pp.427-428
    • /
    • 2017
  • 최근 통신 기술의 발달과 대용량화에 의하여 UPS장비를 모듈화하여 용량 증설 시 모듈을 추가로 설치하는 모듈형 UPS의 수요가 증가하고 있다. 모듈형 UPS는 용량 증설 및 수리 시 모듈 교체로 가능하고 높은 전력 밀도를 갖는 장점이 있다. 이러한 특징을 갖는 모듈형 UPS개발을 위해서는 병렬 제어가 필수이다. 본 논문에서는 저항성의 선로임피던스를 고려한 수하(Droop)제어를 이용하여 단일 모듈 33kVA를 최대 6대 병렬운전하여 총 200kVA로 동작하는 Module형 UPS의 병렬 운전기법을 제안한다.

  • PDF

High Voltage Electron Microscopy DataBase System Using Data Grid (데이터 그리드를 이용한 초고전압 투과전자현미경 데이터베이스 시스템)

  • Ahn Young-Heon;Kweon Hee-Seok;Kim Youn-Joong
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2005.07a
    • /
    • pp.583-585
    • /
    • 2005
  • 바이오 및 재료 분야 등 NT(Nano Technology), BT(Bio Technology)에 관련된 연구를 보다 더 수월하게 하기 위해 본원에 설치되어 있는 초고전압 투과전자현미경(High Voltage Electron Microscopy - 이하 HVEM)을 이용한다. HVEM을 통해 획득한 이미지의 정보는 매우 방대하여 하나의 시료를 관찰하는데 있어서 수백 메가 이상의 용량을 차지하고, 연구를 수행하는데 있어서 데이터를 여러 형태로 관찰 분석하기 때문에 수월한 지원을 위해 체계적으로 관리할 수 있는 데이터베이스 시스템이 필요하다. 그러나 일반적인 범용 데이터베이스로는 이러한 대규모의 데이터를 저장할 수 없다. 따라서 본 논문에서는 이러한 용량 데이터를 체계적으로 관리할 수 있도록, 데이터 그리드와 연구 데이터의 정보를 갖는 metadata 테이블을 통해 서로 먼 거리에 있는 연구원들이 데이터를 접근하고 대규모 저장 공간을 갖는 데이터베이스 시스템을 제안한다.

  • PDF

Reconfiguration and Capacitor Control in Distribution System Using PC Cluster System (PC Clustering을 이용한 배전계통 선로재구성 및 커패시터 설치 방안)

  • Song, Myoung-Kee;Mun, Kyeong-Jun;Kim, Hyung-Su;Park, June-Ho;Lee, Hwa-Seok
    • Proceedings of the KIEE Conference
    • /
    • 2003.11a
    • /
    • pp.113-115
    • /
    • 2003
  • 본 논문에서는 확률적인 전역 최적해 탐색 방식인 유전알고리즘과 경험적인 최적화 알고리즘인 Tabu 탐색법을 이용하여 실시간으로 적용 가능한 배전계통 선로 재구성 및 커패시터 용량결정 방안을 제안하고자 한다. 제안한 알고리즘은 PC Cluster System으로 병렬처리하여 배전계통의 손실 최소화를 위한 선로 재구성 및 커패시터 용량 결정문제의 최적해 탐색에 소요되는 계산시간을 단축하고, 실시간 지원시스템의 성능 개선을 도모하고자 한다. PC Cluster System은 이용자의 편의를 위해서 MS Windows 환경에서 구축하였고, Visual C++ 환경에서 개발하였다. 제안한 방법의 유용성을 입증하기 위해 참고 문헌의 예제 계통에 적용한 후 종래의 방법과 비교함으로써 제안한 방법이 해의 탐색속도 및 해의 성능면에서 우수함을 입증하였다.

  • PDF

Characteristics of Utility Transformer on Residential ESS-PCS by PWM Switching (가정용 ESS-PCS의 PWM 스위칭에 따른 상용변압기의 특성 분석)

  • Jung, Haemin;Kim, Hyosung
    • Proceedings of the KIPE Conference
    • /
    • 2015.07a
    • /
    • pp.241-242
    • /
    • 2015
  • 최근 전력수요가 늘어남에 따라 전력공급의 부족 현상이 빈번히 발생하고 있다. 이런 문제점의 예방책으로써 Energy Storage System (ESS)가 고려되고 있으며, 그 중 가정용 ESS는 3kW 정도의 용량이 선호되고 있다. 이러한 레벨의 용량을 갖는 ESS는 40~50V의 공칭전압으로 설계하는 것이 일반적이다. 3kWh 급 가정용 ESS를 220V 교류 계통과 연계하기 위해 계통 연계 인버터는 낮은 ESS의 배터리 전압을 승압하여야 한다. 이 때, 인버터의 AC 출력 전압을 증가하는 방법으로 상용주파수의 변압기를 사용하는 방법을 생각할 수 있다. 이때 LC필터는 변압기의 1차 측 또는 2차 측에 설치 될 수 있다. 후자의 경우 Power Conditioning System (PCS)에 의한 스위칭 주파수의 구형파를 상용변압기에 통과시킬 때 변압기 내의 기생성분들이 나타나는 현상으로 인하여 출력효율이 낮아지게 된다. 본 논문에서는 가정용 ESS의 스위칭 파형에 따른 상용 변압기의 특성에 대하여 연구한다.

  • PDF

A Study on the Increase of the System Performance of wireless Network Using Wireless Sector Beam System (가변 섹터 빔 시스템을 이용한 무선 망011서의 시스템 용량 증대에 대한 연구)

  • Park, Jong;Kim, Woo-Shik;Lee, Kyung-Geun
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2003.04d
    • /
    • pp.424-426
    • /
    • 2003
  • 최근 이동전화를 이용한 무선인터넷, IMT-2000의 화상전화서비스 등 무선 Multimedia의 시대가 도래하고 있다. 그러나. 3G 서비스를 시작한 유럽, 일본의 서비스 사업자들은 막대한 앙 설치비용으로 꿈의 이동전화서비스가 활성화되기 전에 자금 압박으로 몸살을 알고 있다. 이동전화서비스는 유한한 자원인 주파수 밴드를 얼마나 효율적으로 사용하느냐가 양사업자들의 성공과 실패를 가름하는 경쟁력의 무기로 작용한다. 이러한 주파수를 효율적으로 사용할 수 있는 방법 중에 몇 년 전부터 스마트안테나가 제조사, 서비스사업자는 물론 학계의 비상한 관심을 모으고 있다. 본 논문에서는 이동전화서비스 사업자 입장에서 스마트안테나를 현장적용 시험을 통해 시스템 용량증대에 효과가 있는지 확인하고자 한다.

  • PDF

Library Deletion in Ruby on Rails based Application (Ruby on Rails 기반 어플리케이션의 라이브러리 축소)

  • Park, Kyu-Tae;Ji, Jeong-Hoon;Kim, Won-Young;Woo, Gyun
    • Annual Conference of KIPS
    • /
    • 2009.11a
    • /
    • pp.431-432
    • /
    • 2009
  • 근래에 클라우드 컴퓨팅 개념이 도입되면서 수많은 데스크톱 어플리케이션들이 웹기반 어플리케이션으로 옮겨가거나 비슷한 기능의 웹-어플리케이션으로 재차 제작 되고 있는 추세이다[1]. 이에 Ruby on Rails 프레임워크는 웹-플랫폼을 쉽게 개발하고, 유지 보수가 편리한 장점으로 인하여 많은 웹 어플리케이션 개발에서 사용된다[2]. 따라서 Ruby on Rails 기반의 이동형 서버 어플리케이션 형태를 배포하기 위해서는 Ruby 언어를 탑재해야 한다. 하지만 Ruby 전체의 용량은 개발하는 어플리케이션의 절반 이상이거나 상당부분을 차지한다. 이러한 Ruby의 용량을 줄이고, 해당 어플리케이션의 설치 속도를 줄이고자한다. 이는 Ruby 언어의 필수 사용 라이브러리와 개발하려는 어플리케이션에서 참조하는 라이브러리를 찾아낸 다음 불필요한 부분들을 제거해 나가는 방법으로 연구하였다.

A fundamental study on the development of feasibility assessment system for utility tunnel by urban patterns (도심지 유형별 공동구 설치 타당성 평가시스템 개발에 관한 기초 연구)

  • Lee, Seong-Won;Sim, Young-Jong;Na, Gwi-Tae
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.19 no.1
    • /
    • pp.11-27
    • /
    • 2017
  • The road network system of major domestic urban areas such as city of Seoul was rapidly developed and regionally expanded. In addition, many kinds of life-lines such as electrical cables, telephone cables, water&sewerage lines, heat&cold conduits and gas lines were needed in order for urban residents to live comfortably. Therefore, most of the life-lines were individually buried in underground and individually managed. The utility tunnel is defined as the urban planning facilities for commonly installing life-lines in the National Land Planning Act. Expectation effectiveness of urban utility tunnels is reducing repeated excavation of roads, improvement of urban landscape; road pavement durability; driving performance and traffic flow. It can also be expected that ensuring disaster safety for earthquakes and sinkholes, smart-grind and electric vehicle supply, rapid response to changes in future living environment and etc. Therefore, necessity of urban utility tunnels has recently increased. However, all of the constructed utility tunnels are cut-and-cover tunnels domestically, which is included in development of new-town areas. Since urban areas can not accommodate all buried life-lines, it is necessary to study the feasibility assessment system for utility tunnel by urban patterns and capacity optimization for urban utility tunnels. In this study, we break away from the new-town utility tunnels and suggest a quantitative assessment model based on the evaluation index for urban areas. In addition, we also develop a program that can implement a quantitative evaluation system by subdividing the feasibility assessment system of urban patterns. Ultimately, this study can contribute to be activated the urban utility tunnel.

A Research on PV-connected ESS dissemination strategy considering the effects of GHG reduction (온실가스감축효과를 고려한 태양광 연계형 에너지저장장치(ESS) 보급전략에 대한 연구)

  • Lee, Wongoo;KIM, Kang-Won;KIM, Balho H.
    • Journal of Energy Engineering
    • /
    • v.25 no.2
    • /
    • pp.94-100
    • /
    • 2016
  • ESS(Energy Storage System) is an important source that keeps power supply stable and utilizes electricity efficiently. For example, ESS contributes to resolve power supply imbalance, stabilize new renewable energy output and regulate frequency. ESS is predicted to be expanded to 55.9GWh of installed capacity by 2023, which is 30 times more than that of 2014. To raise competitiveness of domestic ESS industry in this increasing world market, we have disseminated load-shift ESS for continuous power supply imbalance with FR ESS, and also necessity to secure domestic track record is required. However in case of FR ESS, utility of installing thermal power plant is generally generated within 5% range of rated capacity, so that scalability of domestic market is low without dramatic increase of thermal power plant. Necessity of load-shift ESS dissemination is also decreasing effected by surplus backup power securement policy, raising demand for new dissemination model. New dissemination model is promising for $CO_2$ reduction effect in spite of intermittent output. By stabilizing new renewable energy output in connection with new renewable energy, and regulating system input timing of new renewable energy generation rate, it is prospected model for 'post-2020' regime and energy industry. This research presents a policy alternatives of REC multiplier calculation method to induce investment after outlining PV-connected ESS charge/discharge mode to reduce GHG emission, This alternative is projected to utilize GHG emission reduction methodology for 'Post-2020' regime, big issue of new energy policy.

A Study on the Optimization of Ventilation Fan Position and Flow Rate for a Turbine Building of a Power Plant (화력발전소 터빈 본관의 환풍기 위치 및 용량 최적화에 관한 연구)

  • Kim, T.K.;Ha, J.S.;Park, C.H.
    • Journal of Energy Engineering
    • /
    • v.25 no.2
    • /
    • pp.86-93
    • /
    • 2016
  • The existence of high temperature equipment such as steam pipe, deaerator, steam storage tanks and main steam stop valves makes relatively higher workplace temperature in a power plant of the turbine building. In order to cool down the air temperature in the turbine building, the outside air flow with lower temperature passes through the window and the hotter air in the building is extracted to the outside by installing the ventilation fan on the roof. Nevertheless, higher temperature regions near the high temperature equipment still exist in the turbine building and additional fans for the temperature reduction in the higher temperature region should be examined for the optimal location and mass flow rate. The purpose of the present study is to suggest the optimized location and capacity of the additional ventilation fans for a comfortable working environment. From the present study, it has been elucidated that the additional ventilation fans might be located near the high temperature deaerator and it could reduce the mean temperature in the turbine building by $3.0^{\circ}C$ and the temperature near the deaerator could be reduced by $4.2^{\circ}C$.