• Title/Summary/Keyword: 설계 극한 하중

Search Result 284, Processing Time 0.028 seconds

An Experimental Study on Distribution of Ultimate Strength of Concrete-Filled Steel Tube Columns according to Concrete Strength and Section Properties Ratio (콘크리트강도 및 단면특성에 따른 콘크리트 충전강관(CFT) 기둥의 극한강도 분포에 관한 실험적 연구)

  • Jang, Gab-Chul;Chang, Kyong-Ho
    • Journal of Korean Association for Spatial Structures
    • /
    • v.8 no.5
    • /
    • pp.59-65
    • /
    • 2008
  • Recently, to improve the load carrying capacity of column structures such as bridge piers, application to concrete-filled steel tube(CFT) type columns are increased more and more. To design the concrete-filled steel tube(CFT) columns in accuracy, influence of material and geometry properties and aspect ratio on ultimate strength of the concrete-filled steel tube column is investigated by experimental researches. In this investigation, the ultimate strength distribution of the concrete-filled steel tube column in accordance with diameter-thickness ratio(D/t) and steel-concrete area ratio(As/Ac) are clarified by the compressive tests. Futhermore, parametric experimental investigation on concrete target strength is performed. It was known from experimental observation that ultimate strength of concrete-filled steel tube column under axial compressive loading more depends on section properties of steel tube rather than concrete strength.

  • PDF

Development of Short-span Precast Concrete Panels for Railway Bridge (철도교용 단지간 프리캐스트 콘크리트패널의 개발)

  • Seol, Dae-Ho;Lee, Kyoung-Chan;Kim, Ki-Hyun;Youn, Seok-Goo
    • Journal of the Korea Concrete Institute
    • /
    • v.28 no.5
    • /
    • pp.545-553
    • /
    • 2016
  • This paper presents experimental static test results of the precast concrete panels developed for short-span concrete bridge deck form. Different from LB-DECK, concrete rib attached to the bottom surface of concrete panel, and Top-bar is not used at the top surface of concrete panel. Number of concrete ribs and cross-section details of concrete rib are determined from the analytical results of parametric study considering the span length and the thickness of concrete bridge decks. Shear rebars are installed at the top surface of concrete panel for composite action between precast concrete panel and cast-in-place concrete. In order to evaluate the safety and the serviceability of the developed short-span concrete panel subjected to design load, static load test is conducted. Three test panels with span length of 1.6m are fabricated, and during the load test displacements, strains and cracks of test panels are measured and final failure modes are investigated. Serviceability of the test panels is evaluated based on the results of displacements, cracking load, and crack width at the design load level. Safety is also evaluated based on the comparison of the ultimate strength and the factored design load of test panels. Based on the test results, it is confirmed the short-span precast concrete panel satisfies the serviceability and safety regulated in design codes. In addition, the range of span length of concrete bridge decks for the short-span concrete panel is discussed.

Experimental Study on the Behavior Characteristics of Single Steel Pile in Sand Subjected to Lateral Loadings (사질토 지반에서 수평하중에 따른 단일강관말뚝의 거동특성에 관한 실험적 연구)

  • Kim, Daehyeon;Lee, Tae-Gwang;Kim, Sun-Hak
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.5
    • /
    • pp.3548-3556
    • /
    • 2015
  • In order to fulfill the needs of reliable and economically feasible foundation, engineers should consider not only the working load that can endure extreme conditions but also apprehending precise behavior of continuous dynamic load while designing the foundation of offshore wind power generators. To actualize the foundation, a model pile was made in miniature. Also, calibration chamber was made and a 500mm height of sand-bed was made to perform "static lateral load experiment" and "repetitive loading experiment", total of two Lateral load tests. As a result, in Static Lateral load test, the bigger length/diameter of model pile led an increase in load displacement. However, when performing "Cyclic Lateral load test", the increase in number of under loading led the decrease in horizontal displacement from each repeated lateral load. While performing Static Lateral load test and repeated loading experiment, we could observe the decreasing in the rate of ultimate lateral load capacity increase of the pile. Also, it turned out that the higher relative density of the ground, the lower ultimate lateral load capacity by repeated horizontal loading.

Design and Analysis of a Mooring System for an Offshore Platform in the Concept Design Phase (해양플랜트 개념설계 단계에서의 계류계 초기 설계 및 해석)

  • Sungjun Jung;Byeongwon Park;Jaehwan Jung;Seunghoon Oh;Jongchun Park
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.29 no.2
    • /
    • pp.248-253
    • /
    • 2023
  • Most offshore platforms utilize chain mooring systems for position keeping. However, information regarding related design modification processes is scarce in literature. This study focuses on the floating liquefied natural gas (LNG) bunkering terminal (FLBT) as the target of shore platform and analyzes the corresponding initial mooring design and model tests via numerical simulations. Subsequently, based on the modified design conditions, a new mooring system design is proposed. Adjusting the main direction of the mooring line bundle according to the dominant environmental direction is found to significantly reduce the mooring design load. Even turret-moored offshore platforms are exposed to beam sea conditions, leading to high mooring tension due to motions in beam sea conditions. Collinear environmental conditions cannot be considered as design conditions. Mooring design loads occur under complex conditions of wind, waves, and currents in different environmental directions. Therefore, it is essential appropriately assign the roll damping coefficients during mooring analysis because the roll has a significant effect on mooring tension.

A Study on LRFD Reliability Based Design Criteria of RC Flexural Members (R.C. 휨부재(部材)의 L.R.F.D. 신뢰성(信賴性) 설계기준(設計基準)에 관한 연구(研究))

  • Cho, Hyo Nam
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.1 no.1
    • /
    • pp.21-32
    • /
    • 1981
  • Recent trends in design standards development in some European countries and U.S.A. have encouraged the use of probabilistic limit sate design concepts. Reliability based design criteria such as LSD, LRFD, PBLSD, adopted in those advanced countries have the potentials that they afford for symplifying the design process and placing it on a consistent reliability bases for various construction materials. A reliability based design criteria for RC flexural members are proposed in this study. Lind-Hasofer's invariant second-moment reliability theory is used in the derivation of an algorithmic reliability analysis method as well as an iterative determination of load and resistance factors. In addition, Cornell's Mean First-Order Second Moment Method is employed as a practical tool for the approximate reliability analysis and the derivation of design criteria. Uncertainty measures for flexural resistance and load effects are based on the Ellingwood's approach for the evaluation of uncertainties of loads and resistances. The implied relative safety levels of RC flexural members designed by the strength design provisions of the current standard code were evaluated using the second moment reliability analysis method proposed in this study. And then, resistance and load factors corresponding to the target reliability index(${\beta}=4$) which is considered to be appropriate level of reliability considering our practices are calculated by using the proposed methods. These reliability based factors were compared to those specified by our current ultimate strength design provisions. It was found that the reliability levels of flexural members designed by current code are not appropriate, and the code specified resistance and load factors were considerably different from the reliability based resistance and load factors proposed in this study.

  • PDF

Structural Static Test of Pylon for External Attachment Separation Load (외부장착물 분리하중에 대한 파일런 구조 정적시험)

  • Kim, Hyun-gi;Kim, Sungchan;Hong, Seung-ho;Choi, Hyun-kyung;Cho, Sang-hwan;Park, Hyung-bae
    • Journal of Aerospace System Engineering
    • /
    • v.16 no.1
    • /
    • pp.104-109
    • /
    • 2022
  • The bomb rack unit (BRU) installed inside the pylon serves to fix external attachments such as external fuel tank or external weapon, and also serves to separate external attachments in case of emergency. In particular, the load generated when the external attachment is separated from the BRU is called the punching load. In this study, we present the results of a structural static test performed to verify the structural integrity of the pylon under the BRU punching condition acting on it. In the structural static test report, we present the implementation method for the separation load of the external attachment and the test profile for the BRU punching load condition, and compared the error between the load input signal and the feed-back signal to determine the appropriateness of load control in each test. Furthermore, we compared the strain results obtained in the numerical analysis and structural test at the main positions of the specimen. As a result, it was shown that the load of the actuators were properly controlled within the allowable error range in each test, and the numerical analysis effectively predicted the test result. Finally, through structural static tests conducted by design limit load and design ultimate load, we verified that the aircraft pylon dealt with in this study has sufficient structural strength for external attachment separation condition.

ZAn Experimental Study on Performance Evaluation of Simplified Composite Steel I-Beam Bridge (초간편 강합성 H형강 교량의 실험 성능평가 고찰)

  • Kim, Jae-Heung;Park, Jong-Sup;Lee, Son-Ho;Choi, Seung-Ho;Lee, Young-Ho
    • Proceedings of the KAIS Fall Conference
    • /
    • 2009.12a
    • /
    • pp.29-32
    • /
    • 2009
  • 본 연구는 도로교 설계 기준 바탕으로 H-형강을 사용하여 20~30m 사이의 지간장을 가진 중 소규모 교량에 적용이 가능한 초간편 교량의 모형실험 결과와 유한요소해석프로그램(ABAQUS)을 사용한 해석 결과와 비교 분석하여 초간편 교량의 성능을 평가한 것이다. 일반적으로 우리나라의 교량들은 시공과정에서 여러 단계를 거쳐 시공한다. 시공단계가 복잡할수록 공사기간은 늘어나기 때문에 기상 현상에 의한 파괴와 교량의 낙후로 인해 유지, 보수, 교체 또는 교량확장을 해야 하는 경우 교통 혼잡과 경제적 손실을 줄 수 있다. 따라서 본 연구는 이와 같은 경제적 손실을 줄일 수 있는 초간편 H형강 교량의 연구의 일환으로 기존의 연구 결과를 모형실험 수행 결과와 비교하여 최적성능을 평가하기 위해 실시하였다. 사용된 실험체는 실험장소인 건설기술연구소의 구조실험동 장소 여건에 따라 10m 안팎의 경간을 갖는 교량으로 제작하였다. 실험체의 설계 제작 과정에 대해 검토한 후 범용구조해석 프로그램을 이용하여 동일한 조건을 적용한 결과를 비교 후 최종적으로 초간편 교량의 성능에 대한 평가를 실시하여 김재흥 등(2009)의 의해 제안된 하중분배계수 값이 적용가능한지 판단하였고, 실험을 통해 응력 분포와 극한하중에 대해 검토하였다.

  • PDF

A Study on the Distribution of Residual Stress for Drilled Shaft (현장타설말뚝의 잔류응력 분포에 관한 연구)

  • Kim, Won-Cheul;Hwang, Young-Cheol;Ahn, Chang-Yoon
    • Journal of the Korean GEO-environmental Society
    • /
    • v.6 no.1
    • /
    • pp.45-51
    • /
    • 2005
  • The distribution of shaft resistance is measured by the static load test with the strain gauge or stress gauge, so that the long-term load distribution must be considered for the pile design. However, the measurement by strain gauge generally assumes the 'zero reading', which is the reading taken at 'zero time' with 'zero' load and the residual stress, which is the negative skin friction(or the negative shaft resistance) caused by the pile construction, is neglected. Therefore, the measured value by strain gauge is different from the true load-distribution because residual stresses were neglected. In this study, the three drilled shafts were constructed, and the strain measurements were carried out just after shaft construction. As a result of this study, it is shown that the true load-distribution of drilled shaft is quite different with known load distribution and the true load-distribution of drilled shaft changed from the negative skin friction to the positive skin according to the load increment.

  • PDF

Crack Width Prediction in Concrete Bridges Considering Bond Resistances affected by Corrosion (부식에 의한 부착저항감소를 고려한 콘크리트 교량의 균열폭 예측)

  • Cho, Tae-Jun;Cho, Hyo-Nam;Park, Mi-Yun
    • Journal of the Korea Concrete Institute
    • /
    • v.18 no.4 s.94
    • /
    • pp.543-552
    • /
    • 2006
  • The current design for crack width control in concrete bridges is incomplete in analytical models. As one of the important serviceability limit states, the crack width be considered with the quantitative prediction of the initiation and propagation of corrosion and corrosion-induced cracking. A serviceability limit state of cracking can be affected by the combined effects of bond, slip, cracking, and corrosion of the reinforcing elements. Considering life span of concrete bridges, an improved prediction of crack width affected by time-dependent general corrosion has been proposed for the crack control design. The developed corrosion models and crack width prediction equation can be used for the design and the maintenance of prestressed and non-prestressed reinforcements by varying time, w/c, cover depth, and geometries of the sections. It can also be used as the rational criteria for the maintenance of existing concrete bridges and the prediction of remaining life of concrete structures.

A Study on Flexural Strength and Buckling Behavior of Compressional Flange for Box Girder (상자형의 압축플랜지 휨강도 및 좌굴거동에 관한 연구)

  • Kim, Hong-Jun;Jung, Hee-Hyo
    • Journal of Korean Society of Steel Construction
    • /
    • v.23 no.6
    • /
    • pp.679-690
    • /
    • 2011
  • Since the elastic buckling problem of the plate has been studied both experimentally and theoretically, the buckling loads with various boundary conditions and loads can be easily determined. Currently, flange and web design specifications are based on the buckling stress and the post-buckling strength and include a safety-factor. Therefore, this study extended suchresearch to the linear buckling theory with ideal conditions and to the ultimate state with post-buckling. The current specifications are based on elastic buckling stress; and therefore, further research on the ultimate behavior of the plate is required. The ultimate strength design concept, which allows finite deflection, is used in this studyto maximize the post-buckling strength in a steel box. An empirical equation, which provides the ultimate strength of the steel box due to the change in the slenderness and optimum rigidity, are suggested based on the experiment results. Moreover, the appropriateness of the current design specifications was analyzed and discussed.