• Title/Summary/Keyword: 설계 극한 하중

Search Result 284, Processing Time 0.028 seconds

Evaluation of the Resistance Bias Factors to Develop LRFD for Gravel Compaction Piles (LRFD 설계를 위한 쇄석다짐말뚝공법의 저항편향계수 산정)

  • Han, Yong-Bae;Park, Joon-Mo;Jang, Yeon-Soo
    • Journal of the Korean Geotechnical Society
    • /
    • v.28 no.2
    • /
    • pp.43-55
    • /
    • 2012
  • In this study, the resistance bias factors are calculated to determine the resistance factor of Gravel Compaction Piles which is one of the soft ground improvement methods. In order to calculate resistance bias factors for gravel compaction piles, two ultimate bearing capacities were analyzed. One is the ultimate bearing capacity in 2.54 cm settlement measured using data of the field loading test on 41 piles and the other is the ultimate bearing capacity calculated using the seven equations concerning bulging failure. The results of analysis show that the probability density function of the calculated ultimate bearing capacities has a lognormal distribution. Resistance bias factor and the coefficient of variation for Greenwood equation are 0.91 and 0.38, respectively, and for those of Hughes & Withers are 1.19 and 0.39. The two equations are suitable for calculating resistance factors for LRFD of soil improvement using gravel compaction piles.

Characteristics of Ultimate Load in a Wind Turbine for IEC 61400-1 DLC1.1 and DLC1.3 (IEC 61400-1 DLC1.1과 DLC1.3에 대한 풍력터빈의 극한하중 특성)

  • Kim, Chung-Ok;Nam, Hyun-Woo;Eum, Hark-Jin;Kim, Gui-Shik
    • Journal of the Korean Solar Energy Society
    • /
    • v.32 no.1
    • /
    • pp.15-24
    • /
    • 2012
  • IEC 61400-1 requires design lifetime of wind turbines at least 20 years, thus wind turbine should be assured for structural safety through load assessment. DLCs have been defined with respect to the load assessment in IEC 61400-1. In addition, if the extreme design values for DLC1.3 are equal or exceed the extreme design value for DLC1.1, DLC1.1 may be omitted. To omit DLC1.1, scale factor (c) will be increased in DLC1.3. However, this particular adjustment is not specified guidelines. Thus, this study was conducted. DLC1.1 was calculated for extrapolation of 50 years-extreme events using several probability distribution functions and fitting methods. And DLC1.3 was calculated for up to seven different values of scale factor (c) with $2{\leq}c{\leq}5$ in steps of 0.5. Finally, in this study, scale factor (c) that was the value of 4.51 was determined.

Bearing Capacity of Shallow Foundation on Geogrid-Reinforced Clay (지오그리드로 보강된 점성토사의 얕은 기초의 지지력)

  • Shin, Bang Woong;Das, Braja M.;Shin, Eun Chul;Chung, Kee Taek
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.14 no.6
    • /
    • pp.1439-1444
    • /
    • 1994
  • Laboratory model test results for the ultimate bearing capacity and allowable bearing capacity at various settlement levels conducted on a strip foundation supported by geogrid-reinforced clay soil have been presented. For mobilization of the maximum possible load-carrying capacity, the optimum width and depth of the reinforcement layers, and the location of the first layer of reinforcement with respect to the bottom of the foundation have been determined.

  • PDF

Experimental Study on Combined Failure Damage of Bi-directional Prestressed Concrete Panel under Impact-Fire Loading (충돌 후 화재에 대한 이방향 프리스트레스트 콘크리트 패널부재의 복합 파괴손상에 관한 실험적 연구)

  • Yi, Na-Hyun;Lee, Sang-Won;Choi, Seung-Jai;Kim, Jang-Ho Jay
    • Journal of the Korea Concrete Institute
    • /
    • v.26 no.4
    • /
    • pp.429-440
    • /
    • 2014
  • Since the World Trade Center and Pentagon attacks in 2001, terror, military attack, or man-made disaster caused impact, explosion, and fire accident have frequently occured on civil infrastructures. However, structural behavior researches on major Prestressed Concrete (PSC) infrastructures such as bridges, tunnels, Prestressed Concrete Containment Vessel (PCCVs), and LNG tanks under extreme loading are significantly lacking. Especially, researches on possible secondary fire scenarios after terror, bombing, collision of vehicles and vessels on concrete structures have not been performed domestically where most of the past researches related to extreme loadings on structures focused on an independent isolated extreme loading scenario. Due to the outcry of public concerns and anxiety of potential terrorist attacks on major infrastructures and structures, a study is urgently needed at this time. Therefore, in this study, the bi-directional prestressed concrete $1400{\times}1000{\times}300mm$ panels applied with 430 kN prestressing force using unbonded prestressing thread bars were experimentally evaluated under impact, fire, and impact-fire combined loadings. Due to test site restrictions, impact tests were performed with 14 kN impactor with drop heights of 10m and 3.5 m to evaluate impact resistance capacity. Also, fire and impact-fire combined loading were tested using RABT fire loading curve. The measured residual strength capacities of PSC and RC specimens applied with impact, fire, impact-fire combined loadings were compared with the residual strength capacity of undamaged PSC and RC specimens for evaluation. The study results can be used as basic research data for related research areas such as protective design and numerical simulation under extreme loading scenarios.

Full Scale Airframe Static Test of 4 Seater Canard Airplane (4인승 선미익 경항공기 전기체 정적 구조시험)

  • Shin, Jeong-Woo;Kim, Sung-Chan;Kim, Sung-Jun;Chae, Dong-Chul;Lee, Sang-Wook;Kim, Tae-Uk;Shim, Jae-Yeul
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.9 no.4
    • /
    • pp.15-23
    • /
    • 2006
  • In this paper, full-scale airframe static test of 4-seater canard airplane(the Firefly) was explained. From the results of the structural analysis, 5 design limit loads test conditions and 11 design ultimate loads test conditions were selected. Test loads analysis was performed and test fixtures and load control system(LCS) were prepared to realize the test loads. To protect the test article during the test, the overload protection system was prepared. Strain and deflection values were acquired through the data acquisition system(DAS) to verify the structural analysis results.

An Assessment Study for Design Load of a Small Wind Turbine (소형풍력발전기의 설계하중 평가 연구)

  • Hyun, Seung-Gun;Kim, Keon-Hoon;Huh, Jong-Chul
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2011.04a
    • /
    • pp.48-53
    • /
    • 2011
  • In this study, it is to verify the applicability for a simplified model(IEC61400-2, Design Require-ments for Small Wind Turbines, 2006-03) is the international standard is used to the structural design. In the design process of a wind turbine, the safety of a designed wind turbine is one of the most important factors. The simplified model can be used to determine the design load for small wind turbines. So, this paper has been re-evaluated a small wind turbine design loads that produced already. As a result, the material characteristic value(Rchar) of Blade, Rotor shaft and the tower are $90E6[N/m^2]$, $441E6[N/m^2]$ and $94E6[N/m^2]$. Therefore, the value of the applied safety factor to each part of the survival probability of 95% are satisfied.

  • PDF

Safety Evaluation Method of Transmission Tower Subjected to Special Load Case According to Broken Wires (전력선 단선으로 인한 이상시 송전철탑의 안전성 평가방법)

  • Jin, Seok Won;Kim, Jong Min;Park, Jong Sup;Kang, Young Jong
    • Journal of Korean Society of Steel Construction
    • /
    • v.20 no.1
    • /
    • pp.131-149
    • /
    • 2008
  • A transmission tower was designed according to general and special load cases based on KEPCO Design Specifications. The special load case such as unbalanced load a cording to some broken wires has not been considered significantly. Therefore, this paper presents investigations on the stability and safety of main post members subjected to unbalanced load and design wind load. In this study, all cases totally considered. From the finite element analyses using LUSAS program, the stresses on the tower subjected to unbalanced load and design wind load were very high in comparison to the allowable stresses of the steel post member that was used. Some of the post member had higher stresses than the yield stress of the steel member. This paper also shows an example to improve the capacity of the post members using increased cross-section members. Based on the analyses results, when investigating the safety of the transmission tower, one must consider thenew design philosophy including ultimate strength of the member and reliability of the special loading cases.

A Study on Equivalent Design Wave Approach for a Wave-Offshore Wind Hybrid Power Generation System (부유식 파력-해상풍력 복합 발전시스템의 등가설계파 기법 적용에 관한 연구)

  • Sohn, Jung Min;Shin, Seung Ho;Hong, Keyyong
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.18 no.3
    • /
    • pp.135-142
    • /
    • 2015
  • Floating offshore structures should be designed by considering the most extreme environmental loadings which may be encountered in their design life. The most severe loading on a wave-offshore wind hybrid power generation system is wave loads. The principal parameters of wave loads are wave length, wave height and wave direction. The wave loads have different effects on the structural behavior characteristic depending on the combination of wave parameters. Therefore, the process of investigation for critical loads based on the individual wave loading parameter is need. Namely, the equivalent design wave should be derived by finding the wave condition which generates the maximum stress in entire wave conditions. Through a series of analysis, an equivalent regular wave height can be obtained which generates the same amount of the hydrodynamic loads as calculated in the response analysis. The aim of this study is the determination of equivalent design wave regarding to characteristic global hydrodynamic responses for wave-offshore wind hybrid power generation system. It will be utilized in the global structural response analysis subjected to selected design waves and this study also includes an application of global structural analysis.

A Study on the Limit State of Steel Structures Under Earthquake (내진해석을 위한 강구조물의 극한상태에 관한 연구)

  • Lee, Seung-Joon;Koo, Min-Se;Chung, Lan;Shin, Dong-Ki
    • Computational Structural Engineering
    • /
    • v.4 no.3
    • /
    • pp.79-88
    • /
    • 1991
  • The procedure of the elastic response spectrum method which is used in the codes of many countries involves the computation of a static horizontal substitute loading resulting from the earthquake. The substitute loading is divided by a behavioral factor in order to take energy dissipation due to the real nonlinear structural behavior and damping effects ect. into account. The behavioral factors widely used in many countries are based not on the exact calculation but only on the empirical data. In order to determine the behavioral factors analytically, it is necessary to define the limit state of structures as a first step. In this work, the methods of the determination of limit state for the steel structures are discussed in the geometric, serviceabile and material apsects, and the behavioral factors for the three types of structures are calculated.

  • PDF

Osterberg Cell $(O-cell^{\circledR})$ method of Static Pile Load Testing in Korea (오스터버그 셀$(O-cell^{\circledR})$을 이용한 말뚝 정재하시험의 국내 적용)

  • Molnit, Thomas
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2006.03a
    • /
    • pp.520-529
    • /
    • 2006
  • 그 동안 몇 차례 오스터버그 셀$(O-cell^{\circledR})$을 이용한 양방향 말뚝 재하시험기법이 국내에 성공적으로 소개/적용된 바 있다. 이 방법은 상대적으로 새롭고 독특한 방법으로서 시험비용과 기존 재래적인 시험방법이 적용상 제한을 받는 경우나 대규모 시험에서 발생할 수 있는 문제점들을 극복할 수 있다. 국내에서는 설계목적을 위한 시험말뚝 뿐 아니라 설계하중이 큰 실제말뚝에 대한 시험이 증가하는 추세에 있다. 이 논문에서 소개하는 양방향 재하시험 방법을 적용하면 기존의 소규모 재하시험 방법에서 발생될 수 있는 주면 마찰력과 선단지지력의 분리측정이나 각각의 지지력에 대한 극한상태를 확인하지 못하는 한계를 극복할 수 있고 시험하중이 270MN을 초과하는 경우까지 적용할 수 있는 장점을 갖고 있다. 본 논문에서는 오스터버그 셀을 이용한 정적 재하시험 방법에 대하여 말뚝종류별로 상세히 기술하였으며 이 시험방법의 장점과 국내현장에 적용되었던 사례를 소개하였다.

  • PDF