• Title/Summary/Keyword: 설계침투량

Search Result 115, Processing Time 0.026 seconds

Experimental Study on the Effect of Drilling Fluid with Different Mix Designs for Bore Hole Collapse Prevention (시추 안정액 배합설계에 따른 공벽 붕괴방지 효과에 관한 실험적 연구)

  • Yoo, Chung-Sik;Choi, Jung-Hyuk;Han, Yun-Su
    • Journal of the Korean Geotechnical Society
    • /
    • v.31 no.1
    • /
    • pp.15-24
    • /
    • 2015
  • This paper presents the results of a reduced-scale physical model investigation into the effect of drilling fluid with different mix designs for bore hole collapse prevention. The bore hole collapse prevention mechanism for the bentonite based drilling fluid was first discussed together with the effect of conditioning with different additives on engineering characteristics of bentonite based drilling fluid. Reduced-scale model tests were then carried out considering field procedures for cases with a decomposed granitic soil with 20% fines and a sand with various drilling fluids with different mix designs. The results indicated that the addition of polymer to the bentonite based drilling fluid decreases the amount of drilling fluid injected, the drilling fluid infiltration thickness and increases the final depth of excavation. Also revealed is that the effect of polymer on the performance of drilling fluid is more pronounced in the decomposed granite soil with 20% fines than the sand. Practical implications of the findings from this study are discussed in great detail.

Design Technique of First Flush Treatment System Using Waterside Land (제외지 지하공간을 활용한 초기우수 제어 시스템 설계기술)

  • Seo, Dongil;Koo, Young Min;Kim, Jaeyoung;Kim, Byung R.
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2015.05a
    • /
    • pp.652-652
    • /
    • 2015
  • 도시유역의 소하천은 불투수 면적의 증가 및 우수관거의 설치로 인해 오염물질 및 강우의 유달률이 증가한 반면 침투 및 저류 기능의 감소로 인해 지하수위가 저하되어 비강우시에 현저하게 유량이 감소되어 하천환경에 심각한 문제를 나타내고 있다. 이러한 문제를 해결하기 위해 다수의 연구에서 유역에 저영향개발기술을 제안하고 있으나 이들은 과다한 면적을 필요로 함에 따라 설치 및 유지관리에 많은 비용이 발생하고 기존에 개발되어 있는 도시유역에 적용하기 어렵다는 문제점이 있다. 본 연구에서는 도시 소하천의 유량과 수질 문제를 저감하기 위해 위와 같은 문제점을 고려하여 하천 제외지 지하공간을 이용하여 초기 우수 제어 시스템을 개발하고자 하였다. 본 시스템은 도시유역에서 강우에 의해 초기에 오염물질이 다량으로 유출되는 소위 초기세척효과를 제어하기 위해 침전시스템을 설치하고 및 교체가 가능한 카트리지형 여과 시스템으로 구성하였다. 여과 시스템에서 섬유필터를 이용하여 수질을 개선하고 또한 침전 및 여과시스템에 저류가 가능하도록 하여 도시 소하천의 유량에 따라 방류를 조절함으로써 도시 하천의 건천화 감소에 도움이 되도록 구성하였다. 또한 초기우수 제어 시스템을 효율적으로 운영하기 위해 SWMM(Storm Water Management Model) 적용 결과와 자동모니터링 스시템을 활용하는 종합설계 및 관리시스템을 개발하고 있다. 이를 위해 시범 유역에 SWMM을 구축하고 보정 및 검증을 실시하였다. ?측 및 SWMM을 이용하여 계산한 결과 연구대상 지역에서 처리시설에서 수용할 수 있는 초기우수유출량의 적정량은 초기강우 4시간 또는 6 mm의 누적강우량으로 산정되었으며 이를 토대로 현장의 지형여건에 따라 시스템의 설계기준이 수립될 수 있다.

  • PDF

Development of minimum-salinity feedwater for reduction of unit production cost of reverse-osmosis desalination plants (역삼투 담수화 시설의 생산단가 절감을 위한 저 염도 지하 기수 개발)

  • Park, Namsik;Jang, Chi Woong;Babu, Roshina
    • Journal of Korea Water Resources Association
    • /
    • v.49 no.5
    • /
    • pp.431-438
    • /
    • 2016
  • Large energy consumption is one of the main weaknesses of RO desalination. A new method is proposed to reduce the energy consumption of RO desalination which depends on the salinity of the feedwater. Low salinity feedwater can be obtained using groundwater wells which extracts both fresh groundwater and subsurface sea water. Subsurface feedwater is advantageous in overcoming other problems associated with surface seawater intakes. Salinities of groundwater depend on a number of factors. In this work a new simulation-optimization model is proposed to identify well locations and pumping rates with would provide the required design flow rate with the minimum salinity. When groundwater is developed in a coastal area, the saltwater wedge advances inland and may contaminate existing groundwater wells, which must be prevented. The model can protect existing wells while developing minimum salinity feedwater. Examples are provided to demonstrate the usage of the model.

Consolidation Analysis of Dredged Fill Ground Installed with Horizontal Drains (I) - Program Development and Verification - (수평배수재가 포설된 준설매립지반의 압밀해석(I) - 프로그램 개발 및 검증 -)

  • Park Chung-Yong;Jang Yeon-Soo;Park Chung-Soon
    • Journal of the Korean Geotechnical Society
    • /
    • v.21 no.10
    • /
    • pp.27-39
    • /
    • 2005
  • A finite difference program with 3-D governing equation expanded from 1-D self-weight consolidation is developed to analyze the consolidation behavior of surface dredged soil with horizontal drains. Various boundary conditions with horizontal drains and seepage pressure of pore water infiltrated to the drains are considered in the program. A laboratory soil chamber experiment for the consolidation of dredged soil is performed to validate the program and the measured settlement-time result is compared with the one predicted by the program. The influence of design conditions of horizontal drains such as horizontal installation spacing, installation depth and number of drain layers, on the consolidation is analyzed.

Injection Characteristics Evaluation of Conductive Grout Material According to Carbon Fiber Mixing Ratio (탄소섬유 배합비에 따른 전도성 그라우트 재료의 주입특성평가)

  • Hyojun Choi;Wanjei Cho;Hyungseok Heo;Teawan Bang;Chanyoung Yune
    • Journal of the Korean GEO-environmental Society
    • /
    • v.24 no.1
    • /
    • pp.15-23
    • /
    • 2023
  • The grouting method is a method of construction for the purpose of waterproofing and reinforcing soft ground. When grout is injected into the ground, there are various types of penetration and diffusion of grout depending on the shape of the ground, the size of soil, the porosity, and the presence or absence of groundwater. the current situation. Therefore, in this study, to investigate the penetration performance of the grouting to conductive material, laboratory tests were performed on the addition of the conductive material. In the injection test, 0%, 3%, and 5% of the mixed water were added as conductive materials to the grout, and the original ground condition was composed of various types of ground composed of gravel and silica sand. Conductive grout is injected by pressure into the model ground using a dedicated injection device, and the injection time (t), pressure (p), flow rate (v) and injection amount (q) are measured, and the hardened body injected in the model ground is collected. Penetration performance was evaluated. In the results of the grout injection experiment, the amount of conductive material used and the grout injection rate showed an inverse relationship, and it was confirmed that the penetration pattern was changed according to the size of the soil particles in the model ground. The grout containing the conductive material has relatively good penetration into the ground and excellent strength and durability of the hardened body, so it was judged that it could be used as an additive for measuring the penetration range of the grout.

Numerical Analysis on Pressurization System of Smoke Control in Consideration of Flow Rate of Supply and Leakage (보충량과 누설량을 고려한 급기가압 제연시스템의 수치해석 연구)

  • Kim, Jung-Yup;Shin, Hyun-Joon
    • Fire Science and Engineering
    • /
    • v.24 no.5
    • /
    • pp.87-93
    • /
    • 2010
  • The fact that the smoke hinders evacuation and fire-fighting activities as well as becomes the major cause of life casualty emphasizes the importance of smoke control system. As one of the fire safety standards designed to secure the smoke safety, NFSC501A (Design Guide for Smoke Control System of Special Evacuation Stairwell and Lobby) has been proposed, preventing smoke from penetrating into the smoke-free escape route by raising the pressure of the smoke control zone higher than fire area. For model building of 20 stories, pressurization system was designed according to standard and pressure field of compartments in whole building induced by pressurization system was analyzed using the network model.

Correlation analysis of pollutants using IoT technology in LID facilities (LID 시설 내 IoT 기술을 활용한 오염물질 상관성 분석)

  • Jeon, Minsu;Choi, Hyeseon;kevin, Geronimo Franz;Reyes, N.J.DG.;Kim, Leehyung
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2021.06a
    • /
    • pp.453-453
    • /
    • 2021
  • 도시지역 비점오염원관리, 물순환 회복, 침투 및 증발산량 증가, 열섬현상 저감을 위한 주요한 방안으로 저영향개발(low impact development, LID)과 그린인프라 기법의 적용되고 있다. LID 시설은 소규모 분산형 시설로써 넓은 지역에 많고 다양한 시설들이 적용되어 시설의 개수가 많으며, 수질 및 토양 내 기성제품에 대한 센서들의 가격은 고가로 형성되어 있어 기기의 경제성 및 유지관리 등 적용하는데 제한적이다. 따라서 과거 모니터링 자료를 기반으로 오염물질들과의 상관성 분석을 통하여 계측이 어려운 항목들을 계측가능한 항목들로부터 예측 가능하며, 선정된 항목들에 대한 비용효율적인 센서를 개발하여 실시간 LID 모니터링이 가능한 비용효율적 모니터링을 개발하였다. 공주대학교 천안캠퍼스의 LID 시설들은 2013년에 조성되어 현재까지 시설이 운영되고 있으며, 5년이상의 과거 강우시 모니터링 자료들을 이용하여 오염물질 상관성 분석을 수행가능 하기에 대상지로 선정하였다. 오염물질 상관성 분석은 2013년부터 2017년도에 침투도랑에서 수행된 강우시 모니터링 자료를 활용하여 각 오염물질들의 상관성을 분석을 수행하였다. 침투도랑 내 유입되는 평균 유입수는 TSS 286.1±318.3 mg/L, BOD 22.6±39.5 mg/L, TN 8.96±5.85 mg/L, TP 1.01±1.11 mg/L로 나타났다. 겨울철에 비해 여름철에서의 오염물질의 유입농도가 높은 것으로 분석되었다. 이는 여름철 고온건조로 인한 노면 내 차량의 주행으로 인한 중금속, 폐타이어 등과 장마철 강우 시 유출된 토사로 인하여 유입수의 농도가 높은 것으로 분석되었다. 오염물질 부하량은 TSS와 COD 0.66으로 유의성이 높은 것으로 나왔으며, COD와 TSS, TP, TN 등 유의성이 높은 것으로 분석되었다. Arduino와 Raspberry PI를 활용하여 저비용 센서와 LTE 모뎀통신과 데이터 베이스 연결하여 개발된 프로그램을 통해서 무선으로 LID 시설에 대한 모니터링을 침투화분2와 식생체류지에 조성하였다. 전력공급이 어려운 식생체류지의 경우 태양열(Solar system) 시스템과 보조 전력 배터리를 조성하여 장마철이나 장기적인 악천후로 인한 전력을 생산하지 못할 경우 보조전력배터리에서 전력을 제공하여 지속적인 모니터링이 이루어지도록 설계하였다. 토양함수량, 토양온도와 Conductivity 등 3종류의 센서를 적용하였으며, 프로그램은 현재 2단계를 통한 2차수정을 통하여 프로그램을 구축하였다. 오차, 오작동, 계측값에 대한 검·보정 작업이 필요하다. 또한 대기자료의 구축을 통해 보다 토양과 LID 시설에 대한 영향분석이 필요한 것으로 사료된다.

  • PDF

Estimation of Reinforcement Effect of Superannuated Fill Dam Repaired by the Permeable Grouting Method (침투그라우팅이 시공된 노후필댐의 보수보강효과 평가)

  • Kim, Yungjin;Heo, Yol;Oh, Byunghyun
    • Journal of the Korean GEO-environmental Society
    • /
    • v.8 no.6
    • /
    • pp.45-52
    • /
    • 2007
  • Maintenance of structural and hydrological safety of the superannuated fill dam is very important subject on the viewpoint of disaster prevention. Mainly, the core of the superannuated fill dams have been damaged continuously by the various harmful external forces such as the typhoons, flash floods and earthquake, and these can be connected to the large scaled general dam failure. Therefore, the research on the repair, remediation and reinforcement of dam is necessary. In this study, the permeable grouting method for the remediation of fill dam was examined by the electrical resistivity survey and the change of permeability of core front. As a result, the permeable grouting method can be useful remediation method for the superannuated fill dam, the leakage from the core front decreased greatly before and after the construction of grouting. Furthermore, it can be said that the turbidity of fill dam may not be greatly increased by grouting.

  • PDF

The Effects of HDPE by Landfill Settlements in the Final Cover System (침하에 의한 폐기물 매립지 최종복토층 HDPE의 영향에 관한 연구)

  • Moon, Chul-Hwan;Lee, Jai-Young;Jeon, Han-Yong
    • Journal of the Korean Geosynthetics Society
    • /
    • v.2 no.3
    • /
    • pp.11-18
    • /
    • 2003
  • The one of the most important concerns in the design of the final cover system is to restrict percolation of water into the waste body. To minimize entering the water, the final cover system has the barrier layer that consists of a single compacted clay liner(CCL) or a composite liner with high density polyethylene(HDPE) overlying CCL. The HDPE as well as CCL can be damaged by landfill settlements. Therefore, this study was conducted to assess the effects of HDPE induced by settlements in the final cover system after closure. The results of the three test that is field test, lysimeter test in laboratory, and prediction of settlement represent that the HDPE in the final cover system is not pretty much affected by settlements and stable on settlements.

  • PDF

Analyzing the effect of LID(Low Impact Development) using the CAT(Catchment hydrologic cycle Assessment Tool) (CAT을 이용한 LID(Low Impact Development) 효과 분석)

  • Jang, Cheol-Hee;Kim, Hyeon-Jun
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2012.05a
    • /
    • pp.278-278
    • /
    • 2012
  • 최근 녹색도시를 지향하면서 도시 내에서의 물의 순환에 대한 관심이 높아지고 있으며 도시계획 단계에서부터 물의 순환을 고려하려는 시도가 이루어지고 있다. 국토해양부, 환경부, 소방방재청 및 지방자치단체들은 법령, 기준, 지침 및 조례 등을 제정하여 물순환을 도시개발 이전의 상태가 될 수 있도록 시설 설치를 유도하고 있다. 그러나, 개별시설들의 조합이 유역규모의 물순환에 미치는 영향 평가는 이루어지고 있지 못한 실정이다. 종래에는 홍수저감을 목적으로 홍수저류지와 침투시설에 대하여 설계하고 시공을 하였으나 장기적인 관점에서 LID 시설의 효과를 평가하여 도시 계획 단계에서 반영하지는 못하였다. 그리고 이들 개별 LID 시설(침투, 저류 등)에 대한 단위 시설의 규모 설계에 그치고 있어 개선 시설이 다중으로 조합되어 분산 계획되었을 경우, 유역 규모에서 물순환의 긍정적인 변화를 판단하기는 어려운 형편이다. 도시지역에서의 LID(Low Impact Development) 효과 분석과 연계된 유역 물순환 해석을 위하여 독일, 호주 및 미국에서는 STORM, Urban Developer, SUSTAIN(System for Urban Stromwater Treatment, and Analysis INtegratration) 및 SWMM LID(Storm Wastewater Management Model LID) 등의 모형을 출시하고 실무에 적용하고 있다. 그러나, 해외에서 개발된 기술은 국내의 유역 환경을 충분히 반영하기 어렵다. 저수지 혹은 하천에서의 취수 등과 같이 국내의 복잡한 물순환 형태를 반영하는데 한계가 있으며, 기존의 물순환 해석모형에 의한 LID 시설을 계획하는 방법은 홍수저감에 국한되어 있고, 하천 유량이나 지하수위 측정 자료가 부족한 대상지역에 대한 장기적인 유역 물순환 및 도시 개발과 같은 토지이용 변화가 물순환에 미치는 영향을 해석하는데 있어 제한이 있고, 개별적으로 설치된 LID 시설들이 유역의 물순환을 개선하는 효과를 종합적, 정량적으로 구현하는데 한계가 있다. 본 연구에서는 도시 개발 지역의 장기간에 걸친 물순환의 변화를 예측하고 물순환을 개선시키는 대안 시설의 효과를 사전에 평가하는 것을 목표로 김현준 등(한국건설기술연구원, 2011)이 개발한 유역 물순환 해석 모형인 CAT(Catchment hydrologic cycle Assessment Tool)을 이용하였다. 특히, CAT은 사용자의 목적에 맞는 다양한 물순환 개선시설(침투시설, 저류지, 습지, 빗물저장 시설, 리사이클 및 외부급수 등)의 구현 및 모의가 가능하도록 개발되었다. 대상유역으로는 경기도 Y지구를 선정하였으며 도시개발 시나리오(전원도시 및 산업도시 등)에 따른 LID 효과 분석을 실시하였다. 대상지역에 대한 도시유형별 개발계획에 따른 개발 전 후 물순환 변화량 분석 및 LID 시설 계획에 의한 물순환 개선효과를 살펴보면 1998년부터 2007년까지의 평균 강우량을 1,271mm라고 할 때 산업도시의 경우 도시 개발 전의 증발산, 직접유출 및 기저유출은 각각 53%, 29%, 19%로 나타났으며 도시 개발 후 35%, 54%, 12%로 직접유출이 개발 전에 비해 86%나 증가하여 개발에 따른 영향이 큰 것으로 나타났다. 따라서, 이러한 개발에 따른 영향을 최소화하기 위하여 LID 시설을 계획하여 효과를 분석한 결과 증발산, 직접유출, 기저유출이 44%, 34%, 13%로 나타나 도시 개발 후의 왜곡된 물순환 체계가 개발전의 수준과 근접하게 나타나 LID 시설의 긍정적인 효과를 검토할 수 있었다. 이상에서와 같이 CAT 모형을 사용하여 도시유역의 물순환 체계를 진단하고, LID 시설의 효과를 평가할 수 있게 됨으로써 향후 도시유역에 대한 물순환 정상화를 실현하기 위한 정책 수립에 기초자료를 제공하고, 설계 실무에 활용될 수 있을 것이다.

  • PDF