• Title/Summary/Keyword: 설계시험평가

Search Result 1,945, Processing Time 0.03 seconds

Constructing Database and Probabilistic Analysis for Ultimate Bearing Capacity of Aggregate Pier (쇄석다짐말뚝의 극한지지력 데이터베이스 구축 및 통계학적 분석)

  • Park, Joon-Mo;Kim, Bum-Joo;Jang, Yeon-Soo
    • Journal of the Korean Geotechnical Society
    • /
    • v.30 no.8
    • /
    • pp.25-37
    • /
    • 2014
  • In load and resistance factor design (LRFD) method, resistance factors are typically calibrated using resistance bias factors obtained from either only the data within ${\pm}2{\sigma}$ or the data except the tail values of an assumed probability distribution to increase the reliability of the database. However, the data selection approach has a shortcoming that any low-quality data inadvertently included in the database may not be removed. In this study, a data quality evaluation method, developed based on the quality of static load test results, the engineering characteristics of in-situ soil, and the dimension of aggregate piers, is proposed for use in constructing database. For the evaluation of the method, a total 65 static load test results collected from various literatures, including static load test reports, were analyzed. Depending on the quality of the database, the comparison between bias factors, coefficients of variation, and resistance factors showed that uncertainty in estimating bias factors can be reduced by using the proposed data quality evaluation method when constructing database.

Evaluation of Fracture Behaviours of Cementitious Composites by High-velocity Projectile Impact (고속 비상체 충격에 의한 시멘트 복합체의 파괴거동 평가)

  • Min, Ji-Young;Cho, Hyun-Woo;Lee, Jang-Hwa;Kim, Sung-Wook;Moon, Jae-Heum
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.19 no.6
    • /
    • pp.55-62
    • /
    • 2015
  • An importance of infrastructures' protection against crash or blast loading has been an emerging issue as structures are becoming much bigger and population densities in downtown are growing up. However, there exists no such a standard to evaluate the protection performance of construction material itself. Prior to building standards for protection assessment techniques, this study performed gas-gun propelled projectile impact tests with series of contact-type monitoring systems to investigate the applicability of each sensing type. Through the impact tests, failure modes and protection performances of both normal concrete and UHPC (Ultra High Performance Concrete) reinforced by steel fibers were also evaluated. The results showed that LVDT could be applicable for the impact test among contact-type sensors and UHPC with fibers had a remarkable potential to improve protection against impact loading.

Performance Evaluation on Blast-resistant of Gastight Door using Numerical Simulation (수치해석을 활용한 가스차단문의 폭발압력저항 성능평가)

  • Shin, Baegeun;Kim, Jiyu;Kim, Euisoo
    • Journal of the Korean Institute of Gas
    • /
    • v.26 no.1
    • /
    • pp.27-33
    • /
    • 2022
  • As the scale of explosions diversifies along with the expansion of gas handling and storage facilities, studies on explosion-proof facilities in preparation for accidents is being actively conducted. The gastight door blocks the expansion pressure caused by blast waves or internal fires, and at the same time protects the personnel and equipment inside. For gastight doors, the regulations related to explosion-proof design are not clearly presented, and studies on the explosion pressure resistance performance evaluation of the facility are insufficient. In this study, the gastight door was modeled in a 3D shape with reference to the regulation ASTM regarding the gastight door standard. Afterwards, evaluation for blast-resistant performance of gastight door using Numerical simulation was evaluated by using ANSYS Explicit Dynamics to compare the deformation.

Assessment on Applicability of Recycled Aggregates for Backfill Materials of Underground Transmission Lines Based on Field Demonstration Tests (지중 송전관로 되메움용 순환골재의 현장실증시험을 통한 적용성 평가)

  • Kang, Sung-Chur;Lee, Kang-Ryel;Ahn, Tae-Bong
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.3 no.1
    • /
    • pp.72-83
    • /
    • 2015
  • Underground transmission lines always generate heat and transmit heat through surrounding backfill materials. Therefore, in the design of power lines it becomes a very crucial factor to transfer heat effectively into the neighbouring soils. In this study, in order to enhance field applicability of recycled aggregates for backfill material of transmission lines, quality criteria and construction criteria were proposed, and thermal stability of power lines through field demonstration tests were analyzed. In the field tests, two types of recycled aggregates and sand which is currently used for backfilling were compared in terms of thermal behaviour. Test results showed that recycled aggregates represented similar trends with sand in temperature and moisture content corresponding to time lapse and distance from the heat source. Consequently, recycled aggregates can be utilized for backfill materials of underground transmission lines as a substitute material of sands.

Full Scale Structural Testing of Small Wind Turbine Composite Blade (풍력발전용 소형복합재 블레이드의 실규모 구조시험)

  • Kim, Hong-Kwan;Kim, Tae-Seong;Lee, Jang-Ho;Moon, Byung-Young;Kang, Ki-Weon
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.35 no.11
    • /
    • pp.1407-1413
    • /
    • 2011
  • In this paper, the structural design for composite blade was performed and full scale structural test was conducted to verify the structural design and integrity of composite blade. Firstly, FE analysis was performed using commercial software ABAQUS under conditions of rated wind speed and Case H in IEC 61400-2. Lay-up sequence and ply thickness were designed based on FE results. And to verify the structural design, full scale structural test was conducted according to IEC 61400-2 under identical loading conditions of FE analysis. Finally, the force-deflection and local strain behavior of composite blade were evaluated.

Deformation Characteristics of the Pressurized Grouting Soil Nailing Systems from the Field Pull-out Tests (현장인발시험을 통한 가압 그라우팅 쏘일네일의 변형특성)

  • Chun, Byungsik;Park, Joosuck;Park, Sisam;Jung, Jongju;Kong, Jinyoung
    • Journal of the Korean GEO-environmental Society
    • /
    • v.9 no.2
    • /
    • pp.61-65
    • /
    • 2008
  • In this study, a newly modified soil nailing technology named as the PGSN (Pressurized Grouting Soil Nailing) system is proposed. Effects of various factors related to the design of the pressurized grouting soil nailing system, such as the length of re-bars and type of reinforcement materials, were examined throughout a series of the displacement-controlled field pull-out tests. 9 displacement-controlled field pull-out tests were performed and the ratio of injected grout volume to grout hole volume were also evaluated based on the measurements. In addition, short-term characteristics of pull-out deformations of the newly proposed PGSN system were analyzed and compared with those of the ordinary soil nailing system by carrying out field pull-out tests. The test results were shown that the displacements of pressurized grouting soil nailing system were decreased 30~36% in comparison with using gravity grouting soil nailing system by the pressurized effect. The displacements of steel tube were diminished 31~32% comparison with using deformed bar by the reinforcement type change from the field pull-out tests.

  • PDF

Evaluation of Freeze-Thaw Effect on the Modulus of Subgrade Soils from Impact Resonance Test (충격공진시험을 이용한 동결.융해에 따른 노상토의 탄성계수 평가)

  • Lee, Jae-Hoan;Kweon, Gi-Chul
    • International Journal of Highway Engineering
    • /
    • v.12 no.3
    • /
    • pp.71-77
    • /
    • 2010
  • Anti-freezing layer does not used in case of non frost heaving in subgrade soils. In this case, the modulus of subgrade soils were varied with freezing and thaw cycles under non frost heaving. That effect should be properly considered in pavement design. Impact resonance test that is nondestructive testing method was used for continuously determining the modulus of subgrade soils during freezing and thaw cycle. The modulus of subgrade soils was identical with freezing and thaw cycles under closed freezing and thaw system which is no water supplement into specimen during testing. There was also no difference in the modulus of subgrade soil between before and after freezing-thaw cycles for all specimens with different water content and density. That is thaw-weakening of subgrade soils do not occur under closed freezing and thaw system. The moduli at freezing conditions are varied with water content and density, but it can be ignored in practical design sense.

Design Method and Evaluation of the Applicability of the Complex AAM Permanent Anchor (복합 AAM 영구 앵커의 설계법 및 적용성 평가)

  • Lee, Hyuk-Jin;Jung, Dae-Hoon;Kim, Jin-Hong;Lee, Chong-Ha;Kim, Hong-Taek
    • 한국방재학회:학술대회논문집
    • /
    • 2007.02a
    • /
    • pp.538-541
    • /
    • 2007
  • In this study, the complex AAM permanent anchor was introduced and the design method for the complex AAM permanent anchor was showed by examining the relationship of the forces applied to the anchor, the ground failure, the loads inducing the tensile failure between the anchors, etc. In order to understand the behavioral characteristics of the complex AAM permanent anchor, the field pullout test was carried out, and the results obtained with the design method were compared with those of the field pullout test.

  • PDF

A compressor Performance Prediction Method for Analyzing the Off-Design Effect of the Gas Turbine Cycle in IGCC Power Plant (IGCC 발전소용 가스터빈 사이클 탈설계점효과 분석을 위한 압축기 성능예측 방법)

  • Kim, Sung-Gon;Lee, Chan
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 1997.10a
    • /
    • pp.99-104
    • /
    • 1997
  • 기존의 천연가스 가스터빈 시스템을 IGCC 발전소에 적용함에 있어 야기되는 탈설계점효과를 고려할 수 있는 압축기 성능곡선의 예측방법을 제안하였다. 압축기 성능해석방법으로는 익렬요소방법에 전압력손실, 유동편차각 모델들을 결합하여 사용하였으며, 본 방법에 의한 예측결과와 실제 압축기 성능실험결과를 비교하였다. 예측결과가 다양한 압축기 운전조건에 대해 시험결과와 비교적 잘 일치하였으며, 이를 통해 본 예측방법이 IGCC 공정설계 및 성능평가시 가스터빈 탈설계점 효과를 분석할 수 있는 기본 모듈로 사용될 수 있을 것이다.

  • PDF

Development of Traffic Information Management System using GIS (GIS를 이용한 교통정보관리 시스템 개발)

  • Park, Min-Soo;Hirofumi, Imach;NamGung, Moon
    • 한국지형공간정보학회:학술대회논문집
    • /
    • 2002.03a
    • /
    • pp.113-118
    • /
    • 2002
  • 본 연구에서는 최종목표인 교통 정보 관리시스템을 개발하기 위하여 1) GIS, 2) 교통시설정보, 3) 교통사고정보를 하나로 통합 운영하는 시스템을 구현하였다. 이를 위해 현재 이용되고 있는 교통시설정보 및 교통사고정보의 관리 현황을 분석하고 교통 정보 관리시스템 설계를 위한 정보를 획득하였다. 수집된 설계 정보를 바탕으로 교통 정보 관리시스템 Logic을 설계하고 설계된 Logic을 기반으로 교통시설관리 시스템과 교통사고관리 시스템을 각각 구현하였으며, 구현된 시스템을 통합하여 교통 정보 관리시스템을 구축하였다. 마지막 단계로 개발한 시스템의 평가를 위해 통합 시험을 실시하고 문제점을 파악함으로써 효율성 높은 교통 정보 관리시스템을 개발하였다. 고도의 정보화 사회에서 지형공간과 관련된 시설물 정보를 비롯한 다량의 정보를 신속히 처리하고 계획 변경 및 시설물의 위치, 보수 및 관리에 있어서 본 연구의 기법을 활용하면 계획수립 및 의사결정에 효율성을 높일 수 있다고 사료된다.

  • PDF