• Title/Summary/Keyword: 설계시험평가

Search Result 1,945, Processing Time 0.033 seconds

Development of Reliability Measurement Method and Tool for Nuclear Power Plant Safety Software (원자력 안전 소프트웨어 대상 신뢰도 측정 방법 및 도구 개발)

  • Lingjun Liu;Wooyoung Choi;Eunkyoung Jee;Duksan Ryu
    • The Transactions of the Korea Information Processing Society
    • /
    • v.13 no.5
    • /
    • pp.227-235
    • /
    • 2024
  • Since nuclear power plants (NPPs) increasingly employ digital I&C systems, reliability evaluation for NPP software has become crucial for NPP probabilistic risk assessment. Several methods for estimating software reliability have been proposed, but there is no available tool support for those methods. To support NPP software manufacturers, we propose a reliability measurement tool for NPP software. We designed our tool to provide reliability estimation depending on available qualitative and quantitative information that users can offer. We applied the proposed tool to an industrial reactor protection system to evaluate the functionality of this tool. This tool can considerably facilitate the reliability assessment of NPP software.

Individual Bioequivalence Tests under 3 X 2 Design (3 X 2 교차설계법에서 개인 생물학적 동등성 검정)

  • Jung, Gyu-Jin;Lim, Nam-Kyoo;Park, Sang-Gue
    • The Korean Journal of Applied Statistics
    • /
    • v.23 no.1
    • /
    • pp.139-150
    • /
    • 2010
  • In recent years, more generic drug products became available. The current regulation for assessing the bioequivalence of two drug formulations is based on the concept of average bioequivalence. This approach has been indicated to be insufficient for assessing switchability between two drug formulations and US FDA has adopted individual bioequivalence as one of the bioequivalence criterion since 2001. The US FDA recommends that individual bioequivalence be assessed based on $2\;{\times}\;4$ crossover design, while a $2\;{\times}\;3$ crossover design may be used as an alternative design to reduce the length and cost of the study. In this paper, a statistical procedure for assessment of individual bioequivalence under $3\;{\times}\;2$ crossover designs is proposed and some statistical points are discussed with $2\;{\times}\;3$ crossover design and $2\;{\times}\;3$ extra-reference design through simulation studies.

Estimation of Coefficient of Earth Pressure At Rest During SCP Installation by Drained Triaxial Compression Test (배수삼축압축시험을 통한 SCP 시공과정 중 정지토압계수 평가)

  • Kwon, Youngcheul
    • Journal of the Korean GEO-environmental Society
    • /
    • v.13 no.11
    • /
    • pp.93-101
    • /
    • 2012
  • SCP is a construction method that maximizes the effects of ground improvement by creating sand piles, which are formed by the compaction within soft ground. SCP is mainly used for consolidation and drain effects in clayey soils, and as a liquefaction countermeasure through effects such as compaction in loose sandy soils. In the design of SCP, if the sand piles with high stiffness are not taken into account, it can become a design that overly considered safety, and increased construction costs are highly likely to cause economic disadvantages. The changes in stress conditions and compaction mechanisms in the subsurface have been identified to a certain extent by study findings to date. However, the studies that considered SCP and in-situ ground as composite ground are fairly limited, and therefore, those studies have not achieved enough results to fully explain the relevant topics. In this study, the ground improved by SCP was regarded as the composite ground that consists of SCP and in-situ ground. Moreover, employing a CID test, this study examined the changes in the stress conditions of in-situ ground according to the installation of SCP through the relations between $K_0$ and SCP replacement ratio. At the same, whether the SCP installation procedure can be recreated in a laboratory was examined using a cyclic triaxial test. According to the test results, the changes in the stress conditions of the original ground occurred most largely in an initial stage of SCP installation, and after a certain time point, the vibration for SCP installation did not have a great influence on the changes in the stress conditions of the ground. Moreover, in order to recreate the behaviors of in-suit ground according to SCP in a laboratory, cyclic loading, which corresponds to casing vibration, was concluded to be essentially required.

The Design and Protective Capacity Assessment of the Prefabricated PC Arch Ammo Magazines (아치형 조립식 PC 탄약고 설계 및 방호성능 평가)

  • Park, Jang-Kweon;Lim, Chul-Won;Ryu, Dong-Woo;Son, Ki-Young;Baek, Jong-Hyuk;Park, Young-Jun
    • Journal of the Korea Institute of Building Construction
    • /
    • v.14 no.6
    • /
    • pp.615-621
    • /
    • 2014
  • This study suggests the design and assembly drawing of the prefabricated precast concrete arch ammo magazines using the numerical analysis as well as the explosion verification test. The protective capacity of the proposed magazines is identified with the maximum support rotation angles measured by explosion verification tests according to the U.S. Unified Facility Criteria 3-340-02. Using numerical analysis, it is examined that oval-type members are better than the semi-circle ones in terms of protective capacity. Based on this numerical results, the design and assemble drawing for the prefabricated precast concrete arch ammo magazine are developed. It is identified that the structure constructed by invented design and assembly drawing has enough protective capacity against blast pressure caused by 133.75kg TNT explosion. The detonation point cannot be open due to the military security. In sum, it could be concluded that the ammo magazine proposed in this study has reliable protective capacity with enough redundancy. The redundancy means that there are more economic design approach with reducing the curved wall thickness.

Structural Performance of the Cast-in-place Anchor in Cracked Concrete used in Power Plant Facilities (균열 콘크리트에 매립된 발전설비 현장설치용 선 설치 앵커의 구조성능 평가)

  • Kim, Dong-Ik;Jung, Woo-young
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.23 no.7
    • /
    • pp.120-128
    • /
    • 2019
  • It is very important to verify the seismic performance and stability of the power plant fixture in the domestic power plant, because earthquakes have increased in frequency around the world which resulted in the frequent occurrence of power plant damage caused by the failure of electric power facilities. In this study, through the on-site inspection of power plant fixation unit installed in domestic power plants, we carried out structural performance evaluation of the fixation unit anchor bolts installed on the concrete slabs. The field survey showed M12 J hook anchor bolts were used. Anchor bolt pullout and shear performance evaluation were performed based on ASTM E 488-96 standard. Moreover, artificial crack with the width of 0.5 mm was applied during the experiment based on ATM355.4 and ETAG 001. The comparison of M12 J hook anchor bolt pullout and shear test result to design value required in domestic and international design standard, show a satisfactory result. M12 J hook anchor pullout and shear performance was found to be about 35% and 7%, respectively, higher than the required design value.

Design a Path Following Line-of-Sight Guidance Law based on Vehicle Kinematics (비행체 운동 역학 기반 경로 추종 시선각 유도 법칙 설계)

  • You, Dong-Il;Shim, Hyun-Chul
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.40 no.6
    • /
    • pp.506-514
    • /
    • 2012
  • This paper represents a method for designing of path following Line-of-Sight(LOS) guidance law based on vehicle kinematics. In general, a LOS guidance law which is composed of gains and approach length as design parameters is designed by empirical or trial-and-error method. These approaches cannot guarantee a precision tracking performance of guidance law consistently. Also, the design parameters should be redesigned with variations of vehicle maneuverability and flight velocity. Based on a vehicle kinematics with its velocity, the proposed method for designing of parameters not only minimizes the number of design parameters, also has a reliable and consistent tracking performance using variable guidance gain changed in accordance with flight velocity. This is validated by nonlinear simulation with $1^{st}$ order attitude response dynamics and flight experiments with given linear and circular path.

Experimental Performance Estimate of a 40m PSC I Girder for Railway Bridges (40m PSC I형 철도교의 동적 성능 평가)

  • Yeo, Inho
    • Journal of the Korean Society for Railway
    • /
    • v.16 no.5
    • /
    • pp.394-401
    • /
    • 2013
  • Here we report the results of an experimental laboratory test to verify the applicability to railway bridges of a PSC I girder of which the upper flange thickness was increased to improve sectional performance. The thicker this flange is, the further upward the neutral axis is moved. If in this way the span length can be increased to 40m long, the bridge may be constructed with four girders instead of five. Therefore, construction cost could be lowered by reducing the weight of the long span structure due to increased sectional efficiency. It was also necessary to be certain that the dynamic performance of this relatively flexible structure would be applicable to railway bridges. Therefore numerical analysis, as well as static and dynamic tests, was carried out for a full-size PSC I girder. Based on these results, it was verified that the performance of the PSC I railway bridge satisfied the performance criteria of the design code.

A Study on Durability Enhancement of Hopper of the Transplanter (정식기 호퍼 내구성 향상에 관한 연구)

  • Lee, Dongkeun;Kim, Young-Joo;Yang, Seung-Hwan;Lee, Sangdae;In, Hyunki
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2017.04a
    • /
    • pp.51-51
    • /
    • 2017
  • 정식기는 주로 노외에서 사용되므로 사용자에 따라 극심한 작업환경 하에 놓일 수 있다. 사용 중 정식기 호퍼에 토양이나 자갈, 돌 등에 의해 반복적인 하중이 가해지거나 순간적인 충격하중이 가해져 취약부가 파손될 가능성이 있으므로, 토양과 직접 맞닿는 삽날부의 경우 내구성을 고려한 설계/제작이 필수적이다. 본 연구에서는 보행형 반자동 정식기 개발에서 고추묘와 같은 초장이 긴 작물의 묘를 효과적으로 이식할 수 있도록 개선된 삽날에 대해 기존 삽날과 강도 및 강성을 비교하고, 그 결과가 삽날의 내구성에 미칠 영향에 대하여 고찰하였다. 실험에는 양날 개폐 방식의 기존 및 개선삽날 2종이 사용되었으며, 각각 3회씩 정적 강도를 평가하였다. 실제 정식기 사용시 하중이 가해지는 방향은 삽날에 수직한 방향의 압축하중으로 이를 모사하여 일정변위 속도로 삽날에 하중을 가하였으며, 시험 진행시 DAQ 시스템을 통해 실시간으로 하중 및 변위 데이터를 저장하여 시험 종료 후 해당 데이터를 이용하여 $P-{\delta}$ 선도를 도출하였다. 시험 결과 기존삽날의 평균 최대하중이 개선삽날에 비해 높은 것으로 나타났으며, 최대 하중이 나타나는 지점의 변위의 경우, 기존삽날이 개선삽날에 비해 짧게 나타났다. 정적 강도측면에서 개선삽날이 기존삽날에 비해 최대 강도가 낮은 것으로 판단할 수 있으나, 실제 호퍼의 내구성에 영향을 줄 수 있는 주요 인자는 반복적으로 가해지는 비교적 낮은 수준의 충격하중으로 볼 수 있다. 이러한 관점에서 볼 때 일정 수준 이상의 강도를 가지면서, 기존삽날에 비해 낮은 강성을 가지는 개선삽날이 변형을 통한 충격에너지 흡수로 오히려 삽날 조립체(호퍼)의 내구성 측면에서 유리할 수 있다. 따라서 향후에는 기존 및 개선삽날을 적용한 호퍼에 대해 피로시험을 수행하여 관련 내용을 실험적으로 검증하고자 한다.

  • PDF

A study on Development of Methods to Rehabilitate the Damaged Prestressed Concrete beam Using Glass Fiber (유리섬유를 이용한 손상된 프리스트레스트 콘크리트 보의 보강공법 개발연구)

  • Kang, Won-Ho;Han, Man-Yop;Lee, Taek-Sung;Rhu, Young-Min
    • Magazine of the Korea Concrete Institute
    • /
    • v.11 no.2
    • /
    • pp.167-175
    • /
    • 1999
  • Many composite girder bridges have been constructed for about thirty five years. Nowadays they are aged or deteriorated because of the increase in traffic and vehicle loads. In this study, the effect of strengthening with glass fiber sheet is investigated to estimate the possibility for applying to damaged prestressed concrete bridges. One normal and eight cracked specimens which had been preloaded were tested. The cracked specimens were strengthened with either external prestressing or bonding glass fiber sheet, or using both methods. The results showed that the maximum loads are almost same for both methods. So it seems that the strengthening with glass fiber sheet can be used for strengthening damaged prestressed concrete girders. It is important that proper devices should be selected to prevent glass fiber sheet from premature bonding failure below its maximum load, which is similar to end anchorage problem in external prestressing method. It is proved that the devices proposed in this paper have sufficient anchoring capability to increase load carrying capacity.

Comparative Study on the Characteristics of Ground Vibrations Produced from Borehole Blast Tests Using Electronic and Electric Detonators (전자뇌관과 전기뇌관을 사용한 시추공 발파시험에서의 지반진동 특성에 관한 비교 연구)

  • Choi, Hyung-Bin;Won, Yeon-Ho
    • Explosives and Blasting
    • /
    • v.28 no.2
    • /
    • pp.37-49
    • /
    • 2010
  • Ground vibration caused by blasting in the urban area close to structures can give some indirect damage to human body and may lead to structural damage to buildings. At the stage of design or when complaints were filed by residents, the test blasting in borehole, which is most practical for expressing simple vibration wave form quantitatively, is usually chosen for assessing the degree of damage to structures. In this paper, some lessons gained from the application of electronic detonator triggering system in borehole test blasting are presented. The difference in delay time of detonator when borehole is blasted by electronic detonator and electric detonator are discussed. The peak particle velocities measured at the structure embedded in the similar rock layer to main line of tunnel at test site and measured at the road surface just above the tunnel having different overburden layers were analysed to draw their relationship. By comparing the results with those appearing in some published literatures, the usefulness of the borehole test blasting and the importance of delay time of detonator are addressed.