• Title/Summary/Keyword: 설계강우강도

Search Result 200, Processing Time 0.032 seconds

Derivation of Flood Hazard Curves for SOC Facilities under Local Intensive Precipitation (LIP(극한강우) 조건하에서 중요 SOC 시설물에 대한 재해도 곡선 작성)

  • Kim, Beom Jin;Han, Kun Yeun*
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.39 no.1
    • /
    • pp.183-194
    • /
    • 2019
  • In recent years, the risk of external flooding of major national facilities has increased significantly since 2000 due to the increase in local heavy rainfall events. For important domestic national facilities, it is necessary to analyze the risk of external flooding as flooding in major sites due to heavy rain can cause functional paralysis in major facilities and ultimately lead to massive trouble events. In order to manage the safety of main facilities and its related facilities at a high level, it is necessary to analyze the degree of disaster such as flood depth, flood flow rate, flood time and flood intensity when extreme floods (LIP) are introduced. In addition, the degree of vulnerability of these related facilities should be assessed and risk assessments should be reassessed through linkage analysis that combines the degree of disaster and vulnerability. By calculating a new flood hazard curve for the flood depth and flood intensity in major national facilities under the heavy rainfall conditions through this study, it is expected to be a basis for the waterproof design of important SOC facilities, flood prevention function design, advancement of flood prevention measures and procedures and evaluation of flood mitigation functions.

A Study on Development Standard Calculation Program of Forest Road Drainage Facilities (임도 배수시설 규격 산정 프로그램 개발에 관한 연구)

  • Choi, Yeon-Ho;Lee, Joon-Woo;Kim, Myeong-Jun
    • Journal of Korean Society of Forest Science
    • /
    • v.100 no.1
    • /
    • pp.25-33
    • /
    • 2011
  • The purpose of this study is to develop a standard calculation program of forest road drainage facilities that may help forest road designers to design forest road drainage facilities more conveniently and precisely. Especially, the characteristics of this program is that the forest road designers may calculate the amount of outflow in the basin using rainfall intensity data conveniently, without the data designers should acquire through site measurements when they carry out indoor preliminary measurements before they go out for outdoor measurements. In this manner, excessive design may be restrained by offering minimum standard calculation for drainage structures. And also this study was designed to facilitate proper layout of drainage structures by calculating outflow discharge of each basin where forest roads will be installed. Especially, this study will contribute to leveling-up of forest design techniques as the researcher has prepared the reports on whole process of drain pipe installation and provided them in the form of computer file or printout, which show a rational design process, and make it possible to modify in case of an error.

Study on Shear Strength Using a Portable Dynamic Cone Penetration Test and Relationship between N-Nc (소형동적콘관입시험을 이용한 전단강도 산정 및 N-Nc 상관관계 연구)

  • Kim, Hyukho;Lim, Heuidae
    • Economic and Environmental Geology
    • /
    • v.50 no.2
    • /
    • pp.145-157
    • /
    • 2017
  • Because of Recent intensive rainfall, nationally landslides and slope failure phenomenon has been frequently occur. Providing proposed-measures to the natural disasters that occur in these localities and the slope, must be derived ground of strength parameters(shear strength) as a design input data. However, it is such as extra deforestation and a lot of economic costs in order to make the access to the current area and the slopes ground survey is required. Thus, by small dynamic cone penetration test machine using the human to carry in the field, it is possible to easily measure the characteristics and strength constant of the ground of more than one region. In this study through researching analysis of the domestic and foreign small dynamic cone penetration test method, it has proposed a cone material and test methods suitable for the country. Cone penetration test Nc in the field has comparated with analysis of the value and the standard penetration test N value. And, in addition to this, direct shear test and borehole shear test were performed by depth, bedrock, and soil type and passing #200 and the correlation of the Nc value. In particular, in the present study, for the sandy soil that has distict distribute in mountain, it is proposed relation of shear strength corresponding to the Nc value (cohesion and internal friction angle) in order to calculate such effective ground shear strength.

Comparison of Critical Tractive Forces for Application of Soil Improvement Material to Bank Revetment Work (호안 제방사면 보강을 위한 지반개량재의 한계소류력 비교)

  • Kim, You-Seong;Kim, Jae-Hong;Seo, Se-Gwan;Bhang, In-Hwang
    • Journal of the Korean Geotechnical Society
    • /
    • v.31 no.2
    • /
    • pp.65-73
    • /
    • 2015
  • The bank revetment work which is conducted on the slope of river bank to protect against flowing water as a geotechnical structure has been applied as an average value of critical tractive force based on domestic and international standard design. Currently, an appropriate evaluation is needed for the hydraulic stability and geotechnical behavior analysis of bank revetments because of the effects of climate change and ambiguous design criterion. This study has compared the critical tractive forces of soil improvement material and conventional materials used for the bank revetment work. Through various experiments, the shear strength of mixtures with soil improvement material was investigated by curing time and mixture ratio. It was found that the critical tractive force of the mixture obtained from a scour test is suitable to the reinforcement of the slope of river bank which has problems such as seepage erosion and scour.

An Analysis of Characteristic Parameters for the Design of Detention Pond in Urbanized Area (도시유역에서 저류지 설계를 위한 특성인자 분석)

  • Lee, Jae-Joon;Kim, Ho-Nyun;Kwak, Chang-Jae
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.6 no.4 s.23
    • /
    • pp.37-47
    • /
    • 2006
  • Urban development results in increased runoff volume and flowrates and shortening in time of concentration, which may cause frequent flooding downstream. Flow retardation structures to limit adverse downstream effects of urban storm runoff are used. There are various types of flow retardation measures include detention basins, retention basins, and infiltration basins. In basic planning phase, a number of planning models of detention ponds which decide storage volume by putting main variables were used to design detention ponds. The characteristics of hydrological parameters $\alpha,\;\gamma$ which are used in planning models of detention pond were analyzed. In this study, detention ponds data of Disaster Impact Assessment report at 22 sites were analyzed in order to investigate correlation between characteristic of urban drainage basin parameter and characteristics of detention pond parameter due to urbanization effects. The results showed that storage volume was influenced by peak discharge ratio $\alpha$ more than runoff coefficient ratio $\beta$ and peak discharge ratio $\alpha$ was influenced by runoff coefficient ratio $\beta$ less than regional parameter n. Storage ratio was mainly influenced by duration of design rainfall in the case of trapezoidal inflow hydrograph such as Donahue et al. method.

Analysis of Intensity-Duration-Quantity (IDQ) Curve for Designing Flood Retention Basin (홍수저류지 설계를 위한 강우강도-지속시간-홍수량(IDQ) 곡선 해석)

  • Kim, Jin Gyeom;Kang, Boosik;Yoon, Byungman
    • Journal of Korea Water Resources Association
    • /
    • v.47 no.1
    • /
    • pp.83-93
    • /
    • 2014
  • This research was carried out for suggesting design criteria and procedure for maximizing flood control capacity by building flood control facilities like flood retention basin built in connection with existing facilities in order to cope with increased uncertainty due to factors such as urbanization and climate change. We suggested the procedure for the analysis under the various scenarios applicable for the cases of determining retention basin capacity as provision for the flood water level increase in main river channel or estimating flood water level reduction effect when retention basin capacity is given. Procedure for estimating design flood hydrograph at any duration using Intensity-Duration-Quantity (IDQ) originated from the existing IDF, and its application example were provided. Based on rainfall estimated by the IDQ analysis, it is possible to calculate an equivalent peak hydrographs under various scenarios, e.g. lower frequency hydrograph under same rainfall duration with water level higher than existing hydrograph, hydrograph with same peak and higher volume due to increased rainfall duration, hydrograph with higher peak and volume than existing hydrograph, etc.

Studies on the Overflow from Torrential Stream -A Case Study at the Samsung-cheon in Mt. Kwanak- (야계(野溪)의 월류발생(越流發生)에 관(關)한 연구(硏究) -관악산(冠岳山) 삼성천(三聖川)에서의 시험사례(試驗事例)-)

  • Woo, Bo Myeong;Kim, Kyong Ha;Jeong, Do Hyeon
    • Journal of Korean Society of Forest Science
    • /
    • v.77 no.3
    • /
    • pp.269-275
    • /
    • 1988
  • To investigate the cause of overflow in the torrential stream, the estimated peak flow of run-off and the maximum tarring capacity of the stream were measured at the upstream of Samsung-cheon located in Kwanak Aboretum during July, 1987. The results obtained from this study could be summarized as follows : 1. The surveyed catchment area was 477ha, which was 116 of the designed area (410ha) by the plan. 2. The maximum rainfall intensity measured was 99.5mm/hr and was almost same as the designed intensity(100mm/hr). 3. The surveyed run-off coefficient was 0.672 that was about twice as much as designed one(0.35). 4. The surveyed peak flow of run-off was $88.59m^3/sec$, 222% as large the designed one($39.9m^3/sec$). 5. The designed cross-sectional area of the stream was $17.25m^2$, which was 68% of the designed one$25.43m^2$. 6. The surveyed hydraulic mean radius was 0.94m, which was shorter than the designed one(1.28m). 7. The surveyed mean stream-bed gradient(0.998%) was almost the same as the designed one(1.00%). 8 The surveyed maximum velocity of flow passing through the stream was 2.87m/sec, 78.0 of the designed one(3.68m/sec). 9 The surveyed run-off capacity of the stream was $49.51m^3/sec$, 53% of the designed one ($93.5m^3/sec$).

  • PDF

A Study on Filter Performance of Materials in Embankment Slope during Heavy Rain (강우시 성토사면 재료의 필터조건검토에 대한 연구)

  • Kim, Sang-Hwan;Mha, Ho-Seong
    • Journal of Korean Society of societal Security
    • /
    • v.1 no.4
    • /
    • pp.65-71
    • /
    • 2008
  • This paper presents the characteristics of internal erosion of embankment slopes due to the localized heavy rain. In this study, the existing analysis methods of filter performance in embankment materials were reviewed. Based on the theoretical concept of filter conditions to prevent particles from being carried in from the adjacent embankment materials, new analysis method was suggested. According to the new analysis method for filter performance, experimental programs were carried out to investigate the filter performance for controlling and sealing any leak which develops through the embankment materials as a result of internal erosion. Three sets of small scale laboratory tests were carried out with changing the main influence factors such as rainfall intensity, gradient of slope, embankment material condition. It was found that the new analysis method for filter performance to prevent particles from being carried in from the adjacent embankment materials was more capable approach to design the filter materials in embankment slopes. The new criterion or method for satisfactory filter performance, therefore, was recommended.

  • PDF

A Case Study on the Stability Analysis of a Cutting Slope Composed of Weathered Granite and Soil (화강풍화암 및 풍화토층 지역 깍기 비탈면의 안정성 검토 사례 연구)

  • Han, Kong-Chang;Ryu, Dong-Woo;Cheon, Dae-Sung;Hong, Eun-Soo
    • Tunnel and Underground Space
    • /
    • v.18 no.4
    • /
    • pp.289-299
    • /
    • 2008
  • Based on the case study on the causes for the failure of cutting slope composed of weathered rock and soil, the factors influencing the design of a cutting slope have been examined, This type of rock and soil is widely distributed on the region whose parent rock is granite. To analyze the stability of the cutting slope, the following series of progress has been conducted: (1) ground characterization by geological survey and ground investigation, (2) the safety factor examination by limit equilibrium analysis and numerical analysis and (3) the comparison and analysis of rainfall and failure history. As a result, the main factors to cause the failure is determined to be the decrease of shear strength in the upper parts whose ground condition is weakened during localized heavy rain. Moreover, the analysis indicates the failure is also closely related to the groundwater inflow path. On the base of this investigation, a reinforcement method is proposed to ensure the stability of the cutting slope.

Development of Urban Flash Flood Warning System Using X-band Dual-Polarization Radar (X-밴드 이중편파 레이더를 이용한 도시 돌발홍수 경보시스템 개발)

  • Lee, Dong-Ryul;Jang, Bong-Joo;Han, Myung-Sun;Hwang, Suk-Hwan;Noh, Huiseong
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2017.05a
    • /
    • pp.21-21
    • /
    • 2017
  • 최근 서울, 부산, 울산 등에서 도시 돌발홍수가 빈번히 발생하고 있고 이에 따른 인명 손실 및 재산 피해가 빠르게 증가하고 있다. 그러나 집중 호우의 대부분은 저고도 대기에서 생성 및 발달되며, 소멸까지의 시간은 2-3 시간에 불과하여 기존의 우리나라 수문기상 관측시스템은 이러한 유형의 강우량 예측에 많은 어려움을 겪고 있는 실정이다. 이 문제를 해결하기 위해 기상, 재난 관련 정부 기관들이 저고도 수문기상 관측을 위한 도시형 X-밴드 레이더 네트워크 구축을 계획하고 있다. 본 연구의 목적은 그보다 선행하여 돌발성 수문기상 재해연구를 위해 한국건설기술연구원에서 도입한 X-band 이중 편파 레이더 시스템을 이용하여 보다 간단하고 정확한 재난 감시 및 예경보 시스템을 개발하는데 있다. 본 연구에서는 X-밴드 레이더 데이터로부터 추정된 정량적 강수량을 모니터링 하여 도시 지역의 돌발홍수를 자동으로 경고하는 방법을 제안한다. 또한 Google 어스 플랫폼을 사용하여 정확한 3D QPE-GIS 매칭 기법을 개발함으로써, 심각한 수문기상 현상이 발생하는 정확한 위치를 추적하고 직관적인 경보서비스를 가능케 한다. 본 연구에서 제안하는 경보시스템은 레이더 데이터 분석도구, 위험결정 도구 및 위험경고 표시 도구의 세 가지 기술로 구성된다. 제안된 돌발홍수 경보시스템은, 시뮬레이션을 통해 X-밴드 레이더 데이터로부터 정량적 강수량이 계산되며, GIS 상에서 레이더 반사도 및 강우강도가 3차원 이미지 형태로 표시된다. 그런 다음 Google 어스에서 3D 큐브 블록으로 대표되는 강수량이 동시에 누적표출 되도록 설계되었다. 또한 분석된 X-밴드 레이더 데이터로부터 지역별 누적 강수량을 업데이트 및 모니터링하고 기 설정된 돌발홍수 발생 한계치(trigger)에 도달하면 홍수경보 메시지를 표시한다. 향후, 제안된 경보시스템에 대한 기술적 도구를 개선하면서 대규모 수문기상 레이더 네트워크로 광범위한 강우를 모니터링하면 전국적인 돌발홍수 경보시스템으로 확대가 가능하다.

  • PDF