• Title/Summary/Keyword: 선형조사선

Search Result 302, Processing Time 0.033 seconds

A method of background noise removal of Raman spectra for classification of liver disease (간 질병 분류를 위한 라만 스펙트럼의 배경 잡음 제거 방법)

  • Park, Aaron;Baek, Sung-June
    • Smart Media Journal
    • /
    • v.2 no.2
    • /
    • pp.33-38
    • /
    • 2013
  • In this paper, we investigated baseline estimation methods for remove background noise using Raman spectra from acute alcohol liver injury and acute ethanol-induced chronic liver fibrosis. Far the baseline estimation, we applied first derivative, linear programming and rolling ball method. Optimal input parameter of each method were determined by the training rate of MAP (maximum a posteriori probability) classifier. According to the experimental results, classification results baseline estimation with the rolling ball algorithm gave about 89.4%, which is very promising results for classification of acute alcohol liver injury and acute ethanol-induced chronic liver fibrosis. From these results, to determined the appropriate methods and parameters of baseline estimation impact on classification performance was confirmed.

  • PDF

Safely Improving Method to Zero-Harmonics Current with 4-Pole Low Voltage Circuit Breaker Equipped N-phase Trip Device (4극 저압차단기 N상 Trip장치를 사용한 영상고조파 안전성 개선방안)

  • Ki, Che-Ouk;Kim, Ju-Chul;Choi, Chang-Kyu
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2009.05a
    • /
    • pp.458-461
    • /
    • 2009
  • In 3-phase 4 wire system, appearance of the $3^{rd}$ harmonic current by increasing non-liner load is the one of causes overheating neutral wire of power line, and apparatus. So it is necessary to protect power-factor decreasing by the $3^{rd}$ harmonic, and electric power apparatus, and line safely, in this study, power system accidents caused by the $3^{rd}$ harmonic were investigated, then harmonic components analysis and unbalanced load analysis got accomplished. As result, we proposed the method to protect the power line and apparatus from over-current of neutral line by using the most economic 4-pole low voltage circuit breaker.

  • PDF

Calculation of depth dose for irregularly shaped electron fields (부정형 전자선 조사면의 심부선량과 출력비의 계산)

  • Lee, Byoung-Koo;Lee, Sang-Rok;Kwon, Young-Ho
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.14 no.1
    • /
    • pp.79-84
    • /
    • 2002
  • The main cause factor for effective the output, especially in small & irregular shaped field of electron beam therapy, are collimation system, insert block diameter and energy. In the absorption deose of treatment fields, we should consider the lateral build-up ratio (LBR), which the ratio of dose at a point at depth for a given circular field to the dose at the same point for a 'broad-field', for the same incident fluence and profile. The LBR data for a small circular field are used to extract radial spread of the pencil beam, ${\sigma}$, as a function of depth and energy. It's based on elementary pencil beam. We consider availability of the factor, ${\sigma}$, in the small & irregular fields electron beam treatment.

  • PDF

Study on Dosimetric Properties of Radiophotoluminescent Glass Rod Detector (유리선량계의 선량 특성에 관한 연구)

  • Rah, Jeong-Eun;Shin, Dong-Oh;Hong, Ju-Young;Kim, Hee-Sun;Lim, Chun-Il;Jeong, Hee-Gyo;Suh, Tea-Suk
    • Journal of Radiation Protection and Research
    • /
    • v.31 no.4
    • /
    • pp.181-186
    • /
    • 2006
  • A radiophotoluminescent glass rod detector (GRD) system has recently become commercially available. We investigate the dosimetric properties of the GRD regarding the reproducibility of signal, dose linearity and energy dependence. The reproducibility of five measurements for 50 GRDs is presented by an average of one standard deviation of each GRD and it is ${\pm}1.2%$. It is found to be linear in response to doses of $^{60}Co$ beam in the range 0.5 to 50 Gy with a coefficient of linearity of 0.9998. The energy dependence of the GRD is determined by comparing the dose obtained using cylindrical chamber to that by using the GRD. The GRD response for each beam is normalized to the response for a $^{60}Co$ beam. The responses for 6 and 15 MV x-ray beams are within ${\pm}1.5%$ (1SD). The energy response of GRD for high-energy photon is almost the same as the energy dependence of LiF:Mg:Ti (TLD-100)and shows little energy dependence unlike p-type silicon diode detector. The GRDs have advantages over other detectors such diode detector, and TLD: linearity, reproducibility and energy dependency. It has been verified to be an effective device for small field dosimetry for stereotactic radiosurgery.

A Study of an Collarette Extraction in Iris Image (홍채 영상에서 자율신경환 추출에 관한 연구)

  • 강진영;김장형
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2003.10a
    • /
    • pp.754-757
    • /
    • 2003
  • In Oriental medicine, the shape of collarette that formed with position in iris of patients often used by health diagnotcian to grasp health condition. In this paper, we present method that effectively extract collarette that exist in Iris image. After proposed method detert iris area using circular edge detector, derides boundary candidate point through radial line search and threshold value establishment. And boundary candidate line is treated to use nearest neighbor calculation at each boundary candidate point, finally extracts collarette through linear interpolation. As a result of experimenting about iris images, We Confirmed that can be used as assistant tool of diagnostic system that can presume state of ventriculus of human body.

  • PDF

Study on the Scale Effect of Viscous Flows around the Ship Stern (선미 점성 유동장에 미치는 척고효과에 관한 연구)

  • Kwak, Y.K.;Min, K.S.;Oh, K.J.;Kang, S.H.
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.34 no.1
    • /
    • pp.1-10
    • /
    • 1997
  • Viscous flow around actual ship is calculated by an use of RANS equations. The propriety of this computing method, usefulness to hull form design and the scale effect which is the effect of viscous flow depending on the scale of ship model are investigated. Reynolds stress is modelled by using k-${\varepsilon}$ turbulence model and the law of wall is applied near the body. Body fitted coordinates are introduced for the treatment of the arbitrary 3-dimensional shape of the ship hull form. The transformed equations in the computational domain are numerically solved by an employment of FVM. In the calculation of pressure, SIMPLE method is adopted and the solution of the discretized equation is obtained by the line-by-line method with the use of TDMA The calculations of two ships, 4410 TEU container carrier and 50,000 DWT class bulk carrier, are performed at model and actual ship scale. The results are compared and discussed with the model test results which are viscous resistance, nominal wake distribution at propeller plane and limiting streamline on the hull surface. They describe the effect of stem form and the scale effect very well. In particular, the calculated nominal wake distribution and limiting streamline are agreed qualitatively with the experiments and the viscous resistance values are estimated within ${\pm}5%$ difference from the resistance tests.

  • PDF

X-ray properties measurement of Flat panel Digital X-ray gas detector (평판형 디지털 엑스레이 가스 검출기의 엑스선 특성 측정기술에 관한 연구)

  • Yoon, Min-Seok;Cho, Sung-Ho;Oh, Kyung-Min;Jung, Suk-Hee;Nam, Sang-Hee;Park, Ji-Goon
    • Journal of the Korean Society of Radiology
    • /
    • v.3 no.1
    • /
    • pp.17-21
    • /
    • 2009
  • The Recently, large area matrix-addressed image detectors are investigated for X-ray imaging with medical diagnostic and other applications. In this paper, a new flat panel gas detector for diagnostic X-ray imaging is proposed, and its characteristics are investigated. The research of flat panel gas detector is not exist at all. Because of difficulty to inject gas against to atmospheric pressure. So almost gas detector made by chamber shape. We made flat panel sample by display technique. (ex: PDP, Fed, etc.) The experimental measurements, the transparent electrodes, dielectric layer, and the MgO protection layer were formed in front glass. And, the X-ray phosphor layer and address electrodes are formed in the rare glass. The dark current, the x-ray sensitivity and linearity as a function of electric field were measured to investigate the electrical properties. From the results, the stabilized dark current density and the significant x-ray sensitivity were obtained. And the good linearity as a function of exposure dose was showed in wide diagnostic energy range. These results means that the passive matrix-addressed flat panel gas detector can be used for digital x-ray imaging.

  • PDF

Dosimetric Properties of LiF:Mg,Cu,Na,Si TL pellets (LiF:Mg,Cu,Na,Si TL 소자의 선량계적 특성)

  • Nam, Young-Mi;Kim, Jang-Lyul;Chang, Si-Young
    • Journal of Radiation Protection and Research
    • /
    • v.26 no.1
    • /
    • pp.7-12
    • /
    • 2001
  • Sintered LiF:Mg,Cu,Na,Si thermoluminescence (TL) pellets were developed for application in radiation dosimetry. In the present study, the TL dosimetric properties of LiF:Mg,Cu,Na,Si TL pellets have been investigated for emission spectrum, dose response, energy response, and fading characteristics. LiF:Mg,Cu,Na,Si TL pellets were made by using a sintering process, that is, pressing and heat treatment from TL powders. Photon irradiations for the experiments were carried out using X-ray beams and a $^{137}Cs$ gamma source at the Korea Atomic Energy Research Institute (KAERI). The average energies and the dose were in the range of 20-662 keV and $10^{-6}-10^{-2}\;Gy$, respectively. The glow curves were measured with a manual type TLD reader(System 310, Teledyne) at a constant nitrogen flux and a linear heating rate. For a constant heating rate of $5^{\circ}C\;s^{-1}$, the main dosimetric peak of glow curve appeared at $234^{\circ}C$, the activation energy was 2.34 eV and frequency factor was $1.00{\times}10^{23}$. TL emission spectrum is appeared at the blue region centered at 410 nm. A linearity of photon dose response was maintained up to 100 Gy. The photon energy responses relative to $^{137}Cs$ response were within ${\pm}20%$ at overall photon energy region. The fading of TL sensitivity of the pellets stored at the room temperature was not found for one year.

  • PDF

Double crystal X-ray diffraction characteristics of $Al_xGa_{1-x}As$ grown by LPE (LPE법으로 성장시킨$Al_xGa_{1-x}As$의 이중결정 X-선 회절 특성)

  • 김인수;이철욱;최현태;배인호;김상기
    • Electrical & Electronic Materials
    • /
    • v.6 no.6
    • /
    • pp.565-572
    • /
    • 1993
  • LPE(liquid phase epiraxy)법으로 성장시킨 $Al_{x}$ Ga$_{1-x}$As (0.15.leq.x.leq.0.67) 에피층의 구조적 특성을 이중결정 X-선 회절장치를 사용하여 조사하였다. GaAs기판과 $Al_{x}$ Ga$_{1-x}$As 에피층의 격자상수 차이로 인해 피이크가 분리되었고 이는 조성비가 증가함에 따라 선형적으로 증가하였다. 그리고 조성비는 Vegard의 법칙으로 구한 값과 기판 및 에피층 피이크 사이 각도분리(.DELTA..theta.)를 측정함으로써 구한 값이 일치하였으며 이때 관계식은 .DELTA..theta.=354.x을 얻었다. 또한 성장된 에피층은 compressive stress를 받고 있으며 조성비(x)가 0.15에서 0.67로 증가함에 따라 응력은 증가하였으며 그리고 피이크의 반치폭으로 부터 계산된 전위밀도가 역시 증가하였다.

  • PDF

Modification of Late Radiation Response of Rat Salivary Glands by Pentoxifylline and Diltiazem (쥐의 타액선 방사선조사 후 만성반응에 Pentoxifylline과 Diltiazem이 미치는 영향)

  • Suh, Hyun-Suk;Yang, Kwang-Mo;Kang, Yun-Kyung
    • Radiation Oncology Journal
    • /
    • v.17 no.3
    • /
    • pp.230-237
    • /
    • 1999
  • Purpose : To elucidate the effects of pentoxifylline and diltiazem on the late response of the salivary glands of the rat after irradiation. Materials and Methods : Sixteen Sprague-Dawley rats were divided into 4 groups : (a) irradiation alone (b) irradiation with pentixifylline (PTX) (c) irradiation with diltiazem (DTZ) (d) irradiation with both PTX and DTZ. Irradiation was given in a single fraction of 16 Gy using 4 MV photon energy through an anterior port encompassing the left side of the salivary gland leaving the right side of salivary gland as a control. PTX, 20 mg/kg and/or DTZ, 50 mg/kg were infused intraperitoneally before irradiation, Two rats from each group were sacrificed on the 10th week and the rest was sacrificed on the 16th week after irradiation. Histopathologic examinations were undertaken for each section and the proportion of vacuolated cells out of the total number of cells under light microscopic fields was calculated. The statistical significance in the difference of the proportion of the vacuolated cells among the experimental groups was evaluated by a $x^2$-test. Results : Irradiated salivary glands of the 10th week group revealed markedly increased number of vacuolated cells compared to those of unirradiated control. The proportion of vacuolated cells was significantly reduced in both the PTX group (p value=0.001) and the combined PTX and DTX group compared to those of irradiation alone group. The DTZ alone group did not reveal the significant reduction of vacuolated cells compared to those of irradiation alone group (p value, >0.05). The 16th week groups revealed similar findings to those of the 10th week group, but the degree of chronic inflammatory cell infiltrates and interstitial fibrosis was increased and the number of acinar cells was reduced compared to those of the 10th week group. Conclusions : PTX significantly reduced the late radiation response of salivary glands, but DTZ did not reduce the same degree as PTX did. Taking the positive results of this study into consideration, it seems reasonable to apply PTX into the clinical trial for the head and neck irradiation to reduce the late radiation sequelae of salivary glands in the near future. At the same time the further experiment to clarify the subcellar mechni는 involved in PTX should be preceded.

  • PDF