• Title/Summary/Keyword: 선형불안정 이론

Search Result 44, Processing Time 0.019 seconds

Digital Modeling of a Time delayed Continuous-Time System (시간 지연 연속 시간 시스템의 디지털 모델링)

  • Park, Jong-Jin;Choi, Gyoo-Seok;Park, In-Ku;Kang, Jeong-Jin
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.12 no.1
    • /
    • pp.211-216
    • /
    • 2012
  • Control Theory for continuous-time system has been well developed. Due to the development of computer technology, digital control scheme are employed in many areas. When delays are in control systems, it is hard to control the system efficiently. Delays by controller-to-actuator and sensor-to-controller deteriorate control performance and could possibly destabilize the overall system. In this paper, a new approximated discretization method and digital design for control systems with multiple state, input and output delays and a generalized bilinear transformation method with a tunable parameter are also provided, which can re-transform the integer time-delayed discrete-time model to its continuous-time model. Illustrative example is given to demonstrate the effectiveness of the developed method.

Analytical Analysis of Segmented Arc Plasma Torch for Plasma Wind Tunnel Facility (플라즈마 풍동 시설용 분절형 아크 플라즈마 토치의 이론적 설계변수 해석)

  • Seo, Jun-Ho;Choi, Soo-Seok;Choi, Seong-Man;Hong, Bong-Guen
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.15 no.4
    • /
    • pp.85-93
    • /
    • 2011
  • A parametric study is conducted for the design of segmented arc plasma torch with the input power and current of 0.4 MW and 300 A, respectively. For this purpose, we use the analytical relationship between input power, current condition, plasma temperature, inner diameter (R) and length (L) of the torch constrictor based on arc channel model. The results reveal that arc plasma temperatures increase monotonically as ��L increases or R decreases for the ranges of R ${\leq}$ 7.5 mm and L ${\leq}$ 1.25 m. For larger valuse of ��R and L than 7.5 mm and 1.25 m, respectively, however, they show non-linear behavior corresponding to the variations of ��L, which stands for the generation of unstable arc plasma. From this parametric study, optimum ranges of R and L are suggested as 5.5 mm ${\leq}$ R ${\leq}$ 7.5 mm and 0.25 m ${\leq}$ L ${\leq}$ 0.5 m for 0.4 MW class segmented arc plasma torch, under which stable arc plasma can be achieved at the input currents of ~300 A.

The Electron Trap Analysis in Thermoluminescent LiF Crystal

  • Park, Dae-Yoon;Ko, Chung-Duck;Lee, Sang-Soo
    • Nuclear Engineering and Technology
    • /
    • v.4 no.3
    • /
    • pp.214-222
    • /
    • 1972
  • In the optic,11 grade LiF crystal, the electron traps corresponding to the thermoluminescence(abbreviated to TL) glow peak develop as irradiation dose is increased. Originally the electron trap of the crystal has two levels but as the dose reaches to the order of 10$^4$rontgen, it attains five levels as observed in the TL glow curves. The five trap depths are determined from the glow peak temperatures for two different heating rates, $\theta$=6.6$^{\circ}C$/sec and 3.4$^{\circ}C$/sec. The electron trap depths have the following values E$_1$=0.79 eV, E$_2$=0.93 eV, E$_3$=1.02 eV, E$_4$=1.35 eV, E$_{5}$=1.69eV. The special feature of thermoluminescence of optical grade LiF is that the traps, except E$_1$and E$_2$corresponding to 12$0^{\circ}C$ glow peak and 15$0^{\circ}C$ glow peak for $\theta$=6.6$^{\circ}C$/sec, have severe thermal instability, namely E$_3$, E$_4$and E$_{5}$ levels disappear during bleaching process. These defects in the optical grade LiF crystal seem annealed out during the course of TL measurement. The fresh or long time unused LiF(Mg) crystal shows only two glow peaks at 17$0^{\circ}C$ and 23$0^{\circ}C$ for $\theta$=6.6$^{\circ}C$/sec, but upon sensitization with r-ray irradiation, it converts to the six glow peak state. The four electron traps, E$_1$, E$_2$, E$_3$, and E$_{6}$ created by r-ray irradiation and corresponding to the glow peaks at T=10$0^{\circ}C$ 13$0^{\circ}C$, 15$0^{\circ}C$ and 29$0^{\circ}C$ are stable and not easily annealed out thermally, The sensitization essentially required to LiF(Mg) dosimeter is to give the crystal the stable six levels in the electron trap. In optical grade LiF, the plot between logarithm of total TL output versus logarithm of r-ray dose gives more supra-linear feature than that of LiF(Mg). However, if one takes the height of 12$0^{\circ}C$ glow peak(S=6.6$^{\circ}C$/sec), instead of the total TL output, the curve becomes close to that of LiF(Mg).

  • PDF

Practical Output Dosimetry with Undefined $N_{dw}{^{Co-60}}$ of Cylindrical Ionization Chamber for High Energy Photon Beams of Linear Accelerator ($N_{dw}{^{Co-60}}$이 정의되지 않은 원통형 이온전리함을 이용한 고에너지 광자선의 임상적 출력선량 결정)

  • Oh, Young-Kee;Choi, Tae-Jin;Song, Ju-Young
    • Progress in Medical Physics
    • /
    • v.23 no.2
    • /
    • pp.114-122
    • /
    • 2012
  • For the determination of absorbed dose to water from a linear accelerator photon beams, it needs a exposure calibration factor $N_x$ or air kerma calibration factor $N_k$ of air ionization chamber. We used the exposure calibration factor $N_x$ to find the absorbed dose calibration factors of water in a reference source through the TG-21 and TRS-277 protocol. TG-21 used for determine the absorbed dose in accuracy, but it required complex calculations including the chamber dependent factors. The authors obtained the absorbed dose calibration factor $N_{dw}{^{Co-60}}$ for reduce the complex calculations with unknown $N_{dw}$ only with $N_x$ or $N_k$ calibration factor in a TM31010 (S/N 1055, 1057) ionization chambers. The results showed the uncertainty of calculated $N_{dw}$ of IC-15 which was known the $N_x$ and $N_{dw}$ is within -0.6% in TG-21, but 1.0% in TRS-277. and TM31010 was compared the $N_{dw}$ of SSDL to that of PSDL as shown the 0.4%, -2.8% uncertainty, respectively. The authors experimented with good agreement the calculated $N_{dw}$ is reliable for cross check the discrepancy of the calibration factor with unknown that of TM31010 and IC-15 chamber.