• Title/Summary/Keyword: 선형경사접합

Search Result 6, Processing Time 0.019 seconds

Performance Evaluation of Steel Moment Frame and Connection including Inclined Column (경사기둥을 포함한 철골모멘트 골조 및 접합부의 성능평가)

  • Kim, Yong-Wan;Kim, Taejin;Kim, Jongho
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.26 no.3
    • /
    • pp.173-182
    • /
    • 2013
  • The building design projects which are being proceeded nowadays pursue a complex and various shape of structures, escaping from the traditional and regular shape of buildings. In this new trend of the architecture, there rises a demand of the research in the structural engineering for the effective realization of such complex-shaped buildings which disassembles the orthogonality of frames. As a distinguished characteristics of the buildings in a complex-shape, there frequently are inclined columns included in the structural frame. The inclined column causes extra axial force and bending moment at the beam-column connection so it is necessary to assess those effects on the structural behavior of the frame and the connection by experiment or analysis. However, with comparing to the studies on the normal beam-column connections, the inclined column connections have not been studied sufficiently. Therefore, this study evaluated the beam-column connections having an inclined column using nonlinear and finite element analysis method. In this paper, steel moment frames having inclined columns were analyzed by the nonlinear pushover analysis to check the global behavior and beam-column connection models were analyzed by the finite element analysis to check the buckling behavior and the fracture potentials.

Analysis of Behavior of Metal Plate Connection by Nonlinear Finite Element Method (비선형 유한요소법을 이용한 메탈 플레이트 접합부의 거동해석)

  • Hyun, Jae-Hyuk;Kun, Gwang-Chul;Lee, Jun-Jae
    • Journal of the Korean Wood Science and Technology
    • /
    • v.27 no.3
    • /
    • pp.23-30
    • /
    • 1999
  • have been many studies to analyze the behavior of metal plate connector that most widely used to connect light frame wood trusses. Finite element method{FEM) was one of the methods for those studies. FEM using linear model may well be applicable to predict the initial slope of load-displacement curve for metal plate connection. However, displacement may be overestimated above experimental results with the increase of load. Therefore, linear model cannot be used for the nonlinear behavior part. To predict real behavior more exactly, nonlinear term was included to FEM model in this study. It was found out that EA and AA mode showed the high agreement between predicted results and experimental ones. However, EE and AE mode showed a little difference between predicted results and experimental ones in nonlinear part. This results might be caused by insufficient reflection of the slip effect. Consequently, the effect of slip shall be considered to approve the accuracy of nonlinear analysis for the behavior of metal plate connection.

  • PDF

The Scattering Performance of a Junction of Rectangular Waveguide to Coaxial Line with Two Skewed Conducting Posts (두 개의 경사진 금속봉을 가진 구형 도파관과 동축 선로의 접합부의 산란 특성)

  • 이상호;신철재
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.13 no.4
    • /
    • pp.351-358
    • /
    • 2002
  • To determine a scattering performance of a rectangular waveguide with two skewed conducting posts in approximation by the mode matching method and the generalized scattering method is presented in this paper. We determined the optimized result from effective analysis to select the adequate eigenmode number in mode matching method for the skewed two conducting posts. And we obtained the scattering performance of the junction of the waveguide to coaxial line with two skewed conducting posts by application of above method. By this result, it can be seen that the transmission performance at output port of waveguide to coaxial line is 3 ㏈ at the angle, 50°And we obtained the reflection performance to decrease linearly along the skewed angle at input port.

An Analytical Study for the Stair Joints Constructed with Prefabricated Form System (선시공 조립식 거푸집 공법을 이용한 계단 접합부의 접합방식에 따른 해석적 연구)

  • Lee, Eun-Jin;Jin, Byung-Chang;Chang, Kug-Kwan
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.301-304
    • /
    • 2008
  • The stair joints constructed with prefabricated system are general method doing structure design at hinge. If you regarded joints to come in contact with a flight of stairs and a slope of stairs as hinge, the moment performance of joints is not in the least moment, so as the bending moment of the stair case is increased, the reinforcement increase. Also the use is decreased because increasing the joint damage of the vibration & fatigue load. No less the reason constructed with pin the stair joints because the construction efficiency of field work is useable. Recently, they are considering the construction efficiency, while the semi-rigid detail for bending performance of joints is proposed, but for now they don't reflect the detail. Therefore, we proposed that reflecting the method at design semi-rigid joints. We compared the moment performance with the stair joints designed at the rigid joints, semi-rigid joints and pin joints. The nonlinear behavior of staircase core statically indeterminate structure. The result of research is that a bending stiffness modulus bring to reflect the semi-rigid performance, the performance of the semi-rigid joint is better than pin joints, and that is judged the system better seismic and vibration performance because have excellent ductility more than rigid joint.

  • PDF

A study on I-V characteristics in JBS rectifiers according to PN junction structures (JBS(Junction Barrier-controlled Schottky)정류기의 PN접합구조에 따른 I-V 특성에 관한 연구)

  • 안병목;정원채
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.13 no.1
    • /
    • pp.13-20
    • /
    • 2000
  • In this paper, we demonstrated an analytical description method of forward votage drop and reverse leakage current of the junction barrier controlled schottky rectifier with linearly graded junction and abrupt junction models. In this case, the vertical depths of device are 1[${\mu}{\textrm}{m}$] and 2[${\mu}{\textrm}{m}$], respectively. Through ion implantation and annealing process, we obtain the data of lateral and depth from implanted 2-dimensional profiles. Also we applied these data to models that indicate the change of depletion each on linearly-graded and abrupt juction as the forward and revers bias. After applied depletion changes to electric characteristics of JBS rectifiers, we calculated the forward I-V, the reverse leakage current and temperatures vs. power dissipations according to each junction. When we compared the rectifier with calculated and measured data, from the calculated results, forward votage drop with linearly graded junction is lower than that of abrupt junction and reverse leakage current with linearly graded junction is lower(≒1$\times$10\ulcorner times) than that of abrupt junction. Also, the power dissipations according to different juction depth(1[${\mu}{\textrm}{m}$], 2[${\mu}{\textrm}{m}$]) of device are calculated. Seeing the calculated results, we confirmed it from analytic model that the rectifier with linearly graded junction retained a low power dissipation up to 600[$^{\circ}C$] in comparison with the rectifier with abrupt junction.

  • PDF

Simulation of Tsunamis in the East Sea Using Dynamically-Interfaced Multi-Grid Model (동적결합둥지형 모형에 의한 동해안 쓰나미 시뮬레이션)

  • Choi, Byung-Ho;Efim, Pelinovsky;Woo, Seung-Buhm;Lee, Jong-Woong;Mun, Jong-Yoon
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.7 no.1
    • /
    • pp.41-55
    • /
    • 2003
  • A dynamically-interfaced multi-grid finite difference model for simulation of tsunamis in the East Sea(Choi et al.) was established and further applied to produce detailed feature of coastal inundations along the whole eastern coast of Korea. The computational domain is composed of several sub-regions with different grid sizes connected in parallel of inclined directions with 16 innermost nested models. The innermost sub-region represents the coastal alignment reasonably well and has a grid size of about 30 meters. Numerical simulations have been performed in the framework of shallow-water equations(linear, as well as nonlinear) over the plane or spherical coordinate system, depending on the dimensions of the sub-region. Results of simulations show the general agreements with the observed data of run-up height for both tsunamis. The evolution of the distribution function of tsunami heights is studied numerically and it is shown that it tends to the log-normal curve for long distance from the source.