• Title/Summary/Keyword: 선택적 회전 각도

Search Result 59, Processing Time 0.033 seconds

Evaluation of canal preparation for apical sealing with various Ni-Ti rotary instruments (수 종의 Ni-Ti 회전 기구들을 이용한 치근단 폐쇄 향상을 위한 근관 확대 평가)

  • Shin, Yoo-Seok;Shin, Su-Jung;Song, Min-Ju;Kim, Eui-Seong
    • Restorative Dentistry and Endodontics
    • /
    • v.36 no.4
    • /
    • pp.300-305
    • /
    • 2011
  • Objectives: The aim of this study was to evaluate the various NiTi rotary instruments regarding their ability to provide a circular apical preparation. Materials and Methods: 50 single canal roots were selected, cut at the cementodentinal junction and the coronal 1/3 of the canals was flared using Gates Glidden burs. Samples were randomly divided into 5 experimental groups of 10 each. In group I, GT files, Profile 04 and Quantec #9 and #10 files were used. In Group II Lightspeed was used instead of Quantec. In Group III, Orifice shaper, Profile .06 series and Lightspeed were used. In Group IV, Quantec #9 and #10 files were used instead of Lightspeed. In Group V, the GT file and the Profile .04 series were used to prepare the entire canal length. All tooth samples were cut at 1 mm, 3 mm and 5 mm from the apex and were examined under the microscope. Results: Groups II and III (Lightspeed) showed a more circular preparation in the apical 1mm samples than the groups that used Quantec (Group I & IV) or GT files and Profile .04 series.(Group V)(p < 0.05) There was no significant difference statistically among the apical 3, 5 mm samples. In 5 mm samples, most of the samples showed complete circularity and none of them showed irregular shape. Conclusions: Lightspeed showed circular preparation at apical 1 mm more frequently than other instruments used in this study. However only 35% of samples showed circularity even in the Lightspeed Group which were enlarged 3 ISO size from the initial apical binding file (IAF) size. So it must be considered that enlarging 3 ISO size isn't enough to make round preparation.

Development of KD- Propeller Series using a New Blade Section (새로운 날개단면을 이용한 KD-프로펠러 씨리즈 개발)

  • J.T. Lee;M.C. Kim;J.W. Ahn;H.C. Kim
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.28 no.2
    • /
    • pp.52-68
    • /
    • 1991
  • A new propeller series is developed using the newly developed blade section(KH18 section) which behaves better cavitation characteristics and higher lift-drag ratio at wide range of angle-of-attack. The pitch and camber distributions are disigned in order to have the same radial and chordwise loading distribution with the selected circumferentially averaged wake input. Since the geometries of the series propeller, such as chord length, thickness, skew and rate distribations, are selected by regression of the recent full scale propeller geometric data, the performance prediction of a propeller at preliminary design stage can be mure realistic. Number of blades of the series propellers is 4 and the expanded blade area ratios are 0.3, 0.45, 0.6 and 0.75. Mean pitch ratios are selected as 0.5, 0.65, 0.8, 0.75 and 1.1 for each expanded area ratio. The new propeller series is composed of 20 propellers and is named as KD(KRISO-DAEWOO) propeller series. Propeller open water tests are performed at the experimental towing tank, and the cavitation observation tests and fluctuating pressure measurements are carried out at the cavitation tunnel of KRISO. $B_{P}-\delta$ curves, which can be used to select the optimum propeller diameter at the preliminary design stage, are derived from a regression analysis of the propeller often water test results. The KD-cavitation chart is derived from the cavitation observation test results by choosing the local maximum lift coefficient and the local cavitation number as parameters. The caviy extent of a propeller can be predicted more accurately by using the KD-cavitation chart at a preliminary design stage, since it is derived from the results of the cavitation observation tests in the selected ship's wake, whereas the existing cavitation charts, such as the Burrill's cavitation chart, are derived from the test results in uniform flow.

  • PDF

In-situ Phase Transition Study of Minerals using Micro-focusing Rotating-anode X-ray and 2-Dimensional Area Detector (집속 회전형 X-선원과 이차원 검출기를 이용한 광물의 실시간 상전이 연구)

  • Seoung, Dong-Hoon;Lee, Yong-Moon;Lee, Yong-Jae
    • Economic and Environmental Geology
    • /
    • v.45 no.2
    • /
    • pp.79-88
    • /
    • 2012
  • The increased brightness and focused X-ray beams now available from laboratory X-ray sources facilitates a variety of powder diffraction experiments not practical using conventional in-house sources. Furthermore, the increased availability of 2-dimensional area detectors, along with implementation of improved software and customized sample environmental cells, makes possible new classes of in-situ and time-resolved diffraction experiments. These include phase transitions under variable pressure- and temperature conditions and ion-exchange reactions. Examples of in-situ and time-resolved studies which are presented here include: (1) time-resolved data to evaluate the kinetics and mechanism of ion exchange in mineral natrolite; (2) in-situ dehydration and thermal expansion behaviors of ion-exchanged natrolite; and (3) observations of the phases forming under controlled hydrostatic pressure conditions in ion-exchanged natrolite. Both the quantity and quality of the in-situ diffraction data are such to allow evaluation of the reaction pathway and Rietveld analysis on selected dataset. These laboratory-based in-situ studies will increase the predictability of the follow-up experiments at more specialized beamlines at the synchrotron.

Robust Semi-auto Calibration Method for Various Cameras and Illumination Changes (다양한 카메라와 조명의 변화에 강건한 반자동 카메라 캘리브레이션 방법)

  • Shin, Dong-Won;Ho, Yo-Sung
    • Journal of Broadcast Engineering
    • /
    • v.21 no.1
    • /
    • pp.36-42
    • /
    • 2016
  • Recently, many 3D contents have been produced through the multiview camera system. In this system, since a difference of the viewpoint between color and depth cameras is inevitable, the camera parameter plays the important role to adjust the viewpoint as a preprocessing step. The conventional camera calibration method is inconvenient to users since we need to choose pattern features manually after capturing a planar chessboard with various poses. Therefore, we propose a semi-auto camera calibration method using a circular sampling and an homography estimation. Firstly, The proposed method extracts the candidates of the pattern features from the images by FAST corner detector. Next, we reduce the amount of the candidates by the circular sampling and obtain the complete point cloud by the homography estimation. Lastly, we compute the accurate position having the sub-pixel accuracy of the pattern features by the approximation of the hyper parabola surface. We investigated which factor affects the result of the pattern feature detection at each step. Compared to the conventional method, we found the proposed method released the inconvenience of the manual operation but maintained the accuracy of the camera parameters.

Autograft Versus Allograft Bone-Patellar Tendon-Bone in Anterior Cruciate Ligament Reconstruction - A Comparison Of Mid-Term Follow-Up Results - (자가 및 동종 골-슬개건-골을 이용한 전방 십자 인대 재건술 -중기 추시 결과의 비교-)

  • Cho, Sung-Do;Cho, Su-Hyun;Woo, Jong-Ken;Yoo, Chang-Hyun;Park, Moon-Su;Lew, Sog-U
    • Journal of the Korean Arthroscopy Society
    • /
    • v.8 no.1
    • /
    • pp.14-18
    • /
    • 2004
  • Purpose: To compare the mid-term follow-up results of anterior cruciate ligament(ACL) reconstruction with the bone-patellar tendon- bone(BTB) autograft to those with the BTB allograft. Materials and Methods: Retrospective study was performed in 59 cases with BTB autograft and 42 cases with BTB allograft. Evaluations include Lysholm score, 2000 IKDC subjective knee score, Shelbourne patello-femoral pain score , Lachman test, pivot shift test, KT-1000 arthrometer test and 2000 IKDC knee examination. Results: There were no significant statistic differences between two groups in Lysholm score and 2000 IKDC subjective knee score of more than 70 (p<0.05). Five cases(8.5%) showed the patello-femoral pain score less than 80 according to Shelboume with autograft group and two cases(4.8%) with allograft group (p<0.05). Lachman test, pivot shift test and KT-1000 arthrometer test showed no significant statistic differences between two groups(P<0.05). Fifty-four cases(91.5%) were normal or nearly normal according to the 2000 IKDC knee examination with autograft group and thirty-eight cases(90.4%) with allograft group(p<0.05).Conclusion: BTB allograft as well as BTB autograft is considered to be an acceptable choice for ACL reconstruction.

  • PDF

Effect of the lower third molar on the treatment of Class III malocclusion (하악 제3대구치 발거 시기가 III급 부정교합의 치료에 미치는 영향)

  • Son, Myung-Ho;Chang, Young-Il
    • The korean journal of orthodontics
    • /
    • v.34 no.5 s.106
    • /
    • pp.394-407
    • /
    • 2004
  • The Purpose of this study was to evaluate the effect of the lower third molar on treatment time and distal en masse movement of the lower dentition in Giass III malocclusions. Thirty subjects (9 males and 27 females) were selected, all of whom were diagnosed as Glass III malocclusion and treated by fixed appliances without premolar and/or molar extraction. They were divided into three groups Group 1 consisted of 12 subjects. whose lower third molars were not extracted during the whole orthodontic treatment. Group 2 consisted of 8 subjects. whose lower third molars were extracted after WEAW application and before removal of the orthodontic appliances. Group 3 consisted of 10 subjects whose lower third molars were extracted before MEAW application. For each subject. overall treatment time and duration of MEAW application were determined. In addition. pre-treatment and post-treatment lateral cephalometric radiographs were analyzed. All data were Processed statistically with ANOVA, and the conclusions were as follows: There was no significant difference among the groups in overall treatment time However, duration of MEAW application was longer in Group 2 than in Group 1 or Group 3. The overjet that was established after orthodontic treatment was largest in Group 3, in which the lower third molars were extracted befor MEAW application. After orthodontic treatment, IMPA decreased in Group 3. but increased in Group 1 and Group 2. There was no significant difference among the three groups in the translation of lower second molars However the tipping movement of lower second molars was significantly different, highest in Group 2 and lowest in Group 1 Therefore. it is thought to be better for the orthodontic treatment of Class III malocclusions to extract the lower third molars before MEAW application. In Group 2, the mandibular plane angle was decreased as a result of forward rotation of the mandible This skeletal change was thought to bring about the difficulty of treatment.

Postoperative Radiotherapy in the Rectal Cancers Patterns of Care Study for the Years of $1998\~1999$ (직장암의 방사선치료에 대한 Patterns of Care Study: $1998{\sim}1999$년도 수술 후 방사선치료 환자들의 특성 및 치료내용에 대한 분석결과)

  • Kim, Jong-Hoon;Oh, Do-Hoon;Kang, Ki-Moon;Kim, Woo-Cheol;Kim, Won-Dong;Kim, Jung, Soo;Kim, June-Sang;Kim, Jin-Hee;Kil, Hak-Jae;Suh, Chang-Ok;Sohn, Seung-Chang;Ahn, Yong-Chan;Yang, Dae-Sik
    • Radiation Oncology Journal
    • /
    • v.23 no.1
    • /
    • pp.22-31
    • /
    • 2005
  • Purpose : To conduct a nationwide survey on the principals in radiotherapy for rectal cancer, and produce a database of Korean Patterns of Care Study. Materials and Methods : We developed web-based Patterns of Care Study system and a national survey was conducted using random sampling based on power allocation methods. Eligible patients were who had postoperative radiotherapy for rectal cancer without gross residual tumor after surgical resection and without previous history of other cancer and radiotherapy to pelvis. Data of patients were Inputted to the web based PCS system by each investigators in 19 institutions. Results : Informations on 309 patients with rectal cancer who received radiotherapy between 1998 and 1999 were collected. Male to female ratio was 59 : 41, and the most common location of tumor was lower rectum ($46\%$). Preoperative CEA was checked in $79\%$ of cases and its value was higher than 6 ng/ml in $32\%$. Pathologic stage were I in $1.5\%$, II in $32\%$, III in $53\%$, and IV in $1.6\%$. Low anterior resection was the most common type of surgery and complete resection was peformed in $95\%$ of cases. Distal resection margin was less than 2 cm in $30\%$, and number of lymph node dissected was less than 12 in $31\%$. Chemotherapy was peformed in $91\%$ and most common regimen was 5-FU and leucovorine ($59\%$). The most common type of field arrangement used for the initial pelvic field was the four field box (Posterior-Right-Left) technique ($65.0\%$), and there was no AP-PA parallel opposing field used. Patient position was prone in $81.2\%$, and the boost field was used in $61.8\%$. To displace bowel outward, pressure modulating devices or bladder filling was used in $40.1\%$. Radiation dose was prescribed to isocenter in $45.3\%$ and to isodose line in 123 cases ($39.8\%$). Percent delivered dose over $90\%$ was achieved in $92.9\%$. Conclusion : We could find the Patterns of Care for the radiotherapy in Korean rectal cancer patients was similar to that of US national survey. The type of surgery and the regimen of chemotherapy were variable according to institutions and the variations of radiation dose and field arrangement were within acceptable range.

A study of the plan dosimetic evaluation on the rectal cancer treatment (직장암 치료 시 치료계획에 따른 선량평가 연구)

  • Jeong, Hyun Hak;An, Beom Seok;Kim, Dae Il;Lee, Yang Hoon;Lee, Je hee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.28 no.2
    • /
    • pp.171-178
    • /
    • 2016
  • Purpose : In order to minimize the dose of femoral head as an appropriate treatment plan for rectal cancer radiation therapy, we compare and evaluate the usefulness of 3-field 3D conformal radiation therapy(below 3fCRT), which is a universal treatment method, and 5-field 3D conformal radiation therapy(below 5fCRT), and Volumetric Modulated Arc Therapy (VMAT). Materials and Methods : The 10 cases of rectal cancer that treated with 21EX were enrolled. Those cases were planned by Eclipse(Ver. 10.0.42, Varian, USA), PRO3(Progressive Resolution Optimizer 10.0.28) and AAA(Anisotropic Analytic Algorithm Ver. 10.0.28). 3fCRT and 5fCRT plan has $0^{\circ}$, $270^{\circ}$, $90^{\circ}$ and $0^{\circ}$, $95^{\circ}$, $45^{\circ}$, $315^{\circ}$, $265^{\circ}$ gantry angle, respectively. VMAT plan parameters consisted of 15MV coplanar $360^{\circ}$ 1 arac. Treatment prescription was employed delivering 54Gy to recum in 30 fractions. To minimize the dose difference that shows up randomly on optimizing, VMAT plans were optimized and calculated twice, and normalized to the target V100%=95%. The indexes of evaluation are D of Both femoral head and aceta fossa, total MU, H.I.(Homogeneity index) and C.I.(Conformity index) of the PTV. All VMAT plans were verified by gamma test with portal dosimetry using EPID. Results : D of Rt. femoral head was 53.08 Gy, 50.27 Gy, and 30.92 Gy, respectively, in the order of 3fCRT, 5fCRT, and VMAT treatment plan. Likewise, Lt. Femoral head showed average 53.68 Gy, 51.01 Gy and 29.23 Gy in the same order. D of Rt. aceta fossa was 54.86 Gy, 52.40 Gy, 30.37 Gy, respectively, in the order of 3fCRT, 5fCRT, and VMAT treatment plan. Likewise, Lt. Femoral head showed average 53.68 Gy, 51.01 Gy and 29.23 Gy in the same order. The maximum dose of both femoral head and aceta fossa was higher in the order of 3fCRT, 5fCRT, and VMAT treatment plan. C.I. showed the lowest VMAT treatment plan with an average of 1.64, 1.48, and 0.99 in the order of 3fCRT, 5fCRT, and VMAT treatment plan. There was no significant difference on H.I. of the PTV among three plans. Total MU showed that the VMAT treatment plan used 124.4MU and 299MU more than the 3fCRT and 5fCRT treatment plan, respectively. IMRT verification gamma test results for the VMAT plan passed over 90.0% at 2mm/2%. Conclusion : In rectal cancer treatment, the VMAT plan was shown to be advantageous in most of the evaluation indexes compared to the 3D plan, and the dose of the femoral head was greatly reduced. However, because of practical limitations there may be a case where it is difficult to select a VMAT treatment plan. 5fCRT has the advantage of reducing the dose of the femoral head as compared to the existing 3fCRT, without regard to additional problems. Therefore, not only would it extend survival time but the quality of life in general, if hospitals improved radiation therapy efficiency by selecting the treatment plan in accordance with the hospital's situation.

  • PDF

Clinical Experience of LINAC-based Stereotactic Radiosurgery for Angiographically Occult Vascular Malformations (혈관조영상 잠재혈관기형에 대한 선형가속기형 정위방사선수술의 임상경험)

  • Kim Dae Yong;Ahn Yong Chan;Lee Jung Il;Nam Do-Hyun;Lim Do Hoon;Lee Jeong Eun;Yeo Inhwan;Huh Seung Jae;Noh Young Joo;Shin Seong Soo;Hong Seung-Chyul;Kim Jong Hyun
    • Radiation Oncology Journal
    • /
    • v.19 no.1
    • /
    • pp.1-9
    • /
    • 2001
  • Purpose : To establish the role of stereotactic radiosurgery (SRS) for the treatment of patients with angiographically occult vascular malformation (AOVM). Materials and Methods : Eleven patients (12 lesions) with AOVM were treated with linear accelerator-based SRS between February 1995 and December 1999. A magnetic resonance imaging of each patients showed well-circumscribed vascular lesion with reticulated core of heterogeneous signal intensity and peripheral rim of low signal intensity. SRS were peformed with the median peripheral dose of 16 Gy (range 13~25). A single isocenter was used with median collimator size of 14 mm (range 8~20) diameter. Results : With a median follow-up period of 42 months (range 12~56), rebleeding occurred in 3 AOVMS at 5, 6 and 12 months after SRS but no further bleeding did. Two patients experienced radiation-induced necrosis associated with permanent neurologic deficit and one patient showed transient edema of increased 72 signal intensity. Conclusion : SRS may be effective for the prevention of rebleeding in AOVM located in surgically inaccessible region of the brain. Careful consideration should be needed in the decision of case selection and dose prescription because the incidence of radiation-induced complications is too high to be accepted.

  • PDF