• Title/Summary/Keyword: 선택적 방법

Search Result 7,896, Processing Time 0.039 seconds

Influence of water absorption on flexural strength and elastic modulus in several resinous teeth splinting materials (수분 흡수가 여러 레진계 치아고정 재료의 굴곡강도와 탄성계수에 미치는 영향)

  • Park, Bae-Young;Kim, Soo-Yeon;Kim, Jin-Woo;Park, Se-Hee;Cho, Kyung-Mo
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.34 no.2
    • /
    • pp.72-79
    • /
    • 2018
  • Purpose: The purpose of this study was to compare flexural strength and elastic modulus of several splinting materials dependent on water absorption. Materials and Methods: Three different materials; LightFix, G-FIX, G-aenial Universal Flo; were used in this study. Thirty rectangular bar specimens ($25{\times}2{\times}2mm$) of each materials were prepared. Fifteen specimens of each materials were stored in 100% relative humidity atmosphere, $37^{\circ}C$ for 24 hours. The other specimens were stored in distilled water, $37^{\circ}C$ for 30 days. Flexural strength and elastic modulus were calculated using Universal testing machine. One-way ANOVA and Scheffe's post hoc test at 95% level of significance were used on all test results. Results: In LightFix, flexural strength and elastic modulus were significantly decreased after aging. In G-FIX, there was no significant change in flexural strength and elastic modulus after aging. In G-aenial Universal Flo, flexural strength was significantly decreased, but elastic modulus did not change significantly. Statistical analysis reveals that flexural strength and elastic modulus increased in the order of LightFix, G-FIX, G-aenial Flo in both 24 hours and 30 days. Conclusion: It could be deduced from this study that flexural strength and elastic modulus of some resins could be changed when it aged in oral environment. Thus this should be considered when choosing a resin to perform a resin-bonded splint.

Study on the soluble exoression of recombinant human eoidermal growth factor using various fusion oartners in Escherichia coli (재조합 대장균에서 다양한 융합 파트너를 이용한 인간 상피세포성장인자의 발현 연구)

  • Kim, Byung-Lip;Baek, Jung-Eun;Kim, Chun-Sug;Lee, Hyeok-Weon;Ahn, Jung-Oh;Lee, Hong-Weon;Jung, Joon-Ki;Lee, Eun-Gyo;Kim, In-Ho
    • KSBB Journal
    • /
    • v.23 no.3
    • /
    • pp.205-212
    • /
    • 2008
  • The efficient soluble expression of human epidermal growth factor (hEGF) was achieved by using functional fusion partners in cytoplasm and periplasm of Escherichia coli (E. coli). hEGF was over-expressed in inactive inclusion body form in cytoplasm of E. coli due to improper disulfide bond formation and hydrophobic interaction, yielding about 5.9 mg/L in flask culture. Six functional fusion partners were introduced by linking to N-terminal part of hEGF gene for the high-level expression of soluble and active hEGF in cytoplasm and peri plasm region. Three fusion partners for cytoplasmic expression such as acidic tail of synuclein (ATS), thioredoxin (Trx) and lipase, and three fusion partners for periplasmic expression such as periplasmic cystein oxidoreductases (DsbA and DsbC) and maltose binding protein (MBP) were investigated. hEGF fused with ATS and DsbA showed over 90% of solubility in cytoplasm and periplasm, respectively. Especially DsbA was found to be an efficient fusion partner for soluble and high-level expression of hEGF, yielding about 18.1 mg/L and three-fold higher level compared to that of insoluble non-fusion hEGF in cytoplasm. Thus, heterologous proteins containing complex disulfide bond and many hydrophobic amino acids can effectively be produced as an active form in E. coli by introducing a suitable peptide or protein.

An Implementation of Lighting Control System using Interpretation of Context Conflict based on Priority (우선순위 기반의 상황충돌 해석 조명제어시스템 구현)

  • Seo, Won-Il;Kwon, Sook-Youn;Lim, Jae-Hyun
    • Journal of Internet Computing and Services
    • /
    • v.17 no.1
    • /
    • pp.23-33
    • /
    • 2016
  • The current smart lighting is shaped to offer the lighting environment suitable for current context, after identifying user's action and location through a sensor. The sensor-based context awareness technology just considers a single user, and the studies to interpret many users' various context occurrences and conflicts lack. In existing studies, a fuzzy theory and algorithm including ReBa have been used as the methodology to solve context conflict. The fuzzy theory and algorithm including ReBa just avoid an opportunity of context conflict that may occur by providing services by each area, after the spaces where users are located are classified into many areas. Therefore, they actually cannot be regarded as customized service type that can offer personal preference-based context conflict. This paper proposes a priority-based LED lighting control system interpreting multiple context conflicts, which decides services, based on the granted priority according to context type, when service conflict is faced with, due to simultaneous occurrence of various contexts to many users. This study classifies the residential environment into such five areas as living room, 'bed room, study room, kitchen and bath room, and the contexts that may occur within each area are defined as 20 contexts such as exercising, doing makeup, reading, dining and entering, targeting several users. The proposed system defines various contexts of users using an ontology-based model and gives service of user oriented lighting environment through rule based on standard and context reasoning engine. To solve the issue of various context conflicts among users in the same space and at the same time point, the context in which user concentration is required is set in the highest priority. Also, visual comfort is offered as the best alternative priority in the case of the same priority. In this manner, they are utilized as the criteria for service selection upon conflict occurrence.

Evaluation to Obtain the Image According to the Spatial Domain Filtering of Various Convolution Kernels in the Multi-Detector Row Computed Tomography (MDCT에서의 Convolution Kernel 종류에 따른 공간 영역 필터링의 영상 평가)

  • Lee, Hoo-Min;Yoo, Beong-Gyu;Kweon, Dae-Cheol
    • Journal of radiological science and technology
    • /
    • v.31 no.1
    • /
    • pp.71-81
    • /
    • 2008
  • Our objective was to evaluate the image of spatial domain filtering as an alternative to additional image reconstruction using different kernels in MDCT. Derived from thin collimated source images were generated using water phantom and abdomen B10(very smooth), B20(smooth), B30(medium smooth), B40 (medium), B50(medium sharp), B60(sharp), B70(very sharp) and B80(ultra sharp) kernels. MTF and spatial resolution measured with various convolution kernels. Quantitative CT attenuation coefficient and noise measurements provided comparable HU(Hounsfield) units in this respect. CT attenuation coefficient(mean HU) values in the water were values in the water were $1.1{\sim}1.8\;HU$, air($-998{\sim}-1000\;HU$) and noise in the water($5.4{\sim}44.8\;HU$), air($3.6{\sim}31.4\;HU$). In the abdominal fat a CT attenuation coefficient($-2.2{\sim}0.8\;HU$) and noise($10.1{\sim}82.4\;HU$) was measured. In the abdominal was CT attenuation coefficient($53.3{\sim}54.3\;HU$) and noise($10.4{\sim}70.7\;HU$) in the muscle and in the liver parenchyma of CT attenuation coefficient($60.4{\sim}62.2\;HU$) and noise ($7.6{\sim}63.8\;HU$) in the liver parenchyma. Image reconstructed with a convolution kernel led to an increase in noise, whereas the results for CT attenuation coefficient were comparable. Image scanned with a high convolution kernel(B80) led to an increase in noise, whereas the results for CT attenuation coefficient were comparable. Image medications of image sharpness and noise eliminate the need for reconstruction using different kernels in the future. Adjusting CT various kernels, which should be adjusted to take into account the kernels of the CT undergoing the examination, may control CT images increase the diagnostic accuracy.

  • PDF

Utilization of Tissue Compensator for Uniform Dose Distribution in Total Body Irradiation (전신방사선조사시 균등한 선량분포를 이루기 위한 조직보상체의 이용)

  • Park, Seung-Jin;Chung, Woong-Ki;Ahn, Sung-Ja;Nam, Taek-Keun;Nah, Byung-Sik
    • Radiation Oncology Journal
    • /
    • v.12 no.2
    • /
    • pp.233-241
    • /
    • 1994
  • Purpose : This study was performed to verify dose distribution with the tissue compensator which is used for uniform dose distribution in total body irradiation(TBI). Materials and methods : The compensators were made of lead(0.8mm thickness) and aluminum(1mm or 5mm thickness) plates. The humanoid phantom of adult size was made of paraffin as a real treatment position for bilateral total body technique. The humanoid phantom was set at 360cm of source-axis distance(SAD) and irradiated with geographical field size(FS) $144{\times}144cm^2(40{\times}40cm^2$ at SAD 100cm) which covered the entire phantom. Irradiation was done with 10MV X-ray(CLINAC 1800, Varian Co., USA) of linear accelerator set at Department of Therapeutic Radiology, Chonnam University Hospital. The midline absorbed dose was checked at the various regions such as head, mouth, mid-neck, sternal notch, mid-mediastinum, xiphoid, umbilicus, pelvis, knee and ankle with or without compensator, respectively. We used exposure/exposure rate meter(model 192, Capintec Inc., USA) with ionization chamber(PR 05) for dosimetry, For the dosimetry of thorax region TLD rods of $1x1x6mm^3$ in volume(LiF, Harshaw Co., Netherland) was used at the commercially available humanoid phantom. Results : The absorbed dose of each point without tissue compensator revealed significant difference(from $-11.8\%\;to\;21.1\%$) compared with the umbilicus dose which is a dose prescription point in TBI. The absorbed dose without compensator at sternal notch including shoulder was $11.8\%$ less than the dose of umbilicus. With lead compensator the absorbed doses ranged from $+1.3\%\;to\;-5.3\%$ except mid-neck which revealed over-compensation($-7.9\%$). In case of aluminum compensator the absorbed doses were measured with less difference(from $-2.6{\%}\;to\;5.3\%$) compared with umbilicus dose. Conclusion : Both of lead and aluminum compensators applied to the skull or lower leg revealed a good compensation effect. It was recognized that boost irradiation or choosing reference point of dose prescription at sternal notch according to the lateral thickness of patient in TBI should be considered.

  • PDF

The Role of Video-Assisted Thoracic Surgery in the Diagnosis and the Treatment of a Mediastinal Mass (종격동 병변의 진단 및 치료와 비디오 흉강경의 역할 -흉강경에 의한 종격동 병변 진단 치료-)

  • Baek, Hyo-Chae;Park, Han-Gi;Bae, Gi-Man;Lee, Du-Yeon
    • Journal of Chest Surgery
    • /
    • v.29 no.7
    • /
    • pp.769-776
    • /
    • 1996
  • The application of video-assisted thoracic surgery (VATS) in the examination of the thoracic cavity can be a new option in patients with mediastinal tumor because it provides outstanding visibility of the structures of the mediastinum. By clear viewing through the thoracoscope, a mediastinal tumor can be biopsied or resected, depending on the findings during an operation. We reviewed all patients who underwent curative or diagnostic operations from March 1990 to August 1995 under the impression of a mediastinal mass. The total number of patients were 113 with 59 males and 54 females. Group A underwent resection of tu or by thoracotomy(38 patients: 18 males, 20 females), and group B underwent resection of tumor by VATS (36 patients : 20 males and 16 females). Seven patients in group B were excluded because they underwent thoracotomy due to pleural adhesion or intra-operative bleeding ; therefore, the true VATS group numbered 29 cases. Group C underwent Iymph node biopsy by VATS(33 patients'16 males, 17 females), and group D(6 patients: 5 males, 1 female) underwent Iymph node biopsy through anterior mediastinotomy. The mean age in group A was 36.2 years compared to 41.3 years In group B. We compared operation time, frequency of injection for pain control, duration of chest tube insertion, postoperative hospital stay, and diagnostic yield. In group A, they were 164 minutes, 3.4 times, 5.2 days, and 11.3 days, respectively, in comparison to 152 minutes, 2 times, 4.7 days, and 8.3 days, respectively, in group B. These data revealed that the day of discharge was significantly shorter in group B (p valu : 0.03). In group C, the mean age was 45.8 years (range 1 ∼70). The operation time was from 30 to 335 minutes (mean 105), pain control was required from 0 to 15 times(mean 3.2), and a chest tube was needed for 1 to 36 days (mean 6.1). In group D, mean age was 53.3 years, operation time 121 minutes, pall control injec- tion frequency 2.6 times, and mean chest tube duration 10.5 days. The diagnostic yield in group C was 8 oyo compared to 100 oyo in group D although the number of patients in group D is small.

  • PDF

Changes in Acidity and Distributions of the Vancomycin-Resistant Lactic Acid Bacteria in the Kimchi Fermented at Different Temperatures (발효 온도에 따른 김치의 산도 변화와 Vancomycin 내성 젖산균의 분포)

  • 정의숙;김기환;신원철;송광영;윤성식
    • Microbiology and Biotechnology Letters
    • /
    • v.32 no.3
    • /
    • pp.249-255
    • /
    • 2004
  • Chinese cabbage ('Baechu') Kimchi was fermented at the three different temperatures right after it was prepared. Samples were taken everyday for measuring bacterial populations, pH, and titratable acidity through the whole periods of fermentation up to 50 days. pH values and developed acidity were significantly affected by the fermenting temperatures of 4, 10, and $20^{\circ}C$, suggesting that different bacterial flora has been established by the temperatures exposed. The modified MRS agar containing vancomycin (300 $\mu$g/mL) was used for isolating the vancomycin-resistant LAB strains and 127 isolates were finally obtained. Of the LAB isolates, 13 isolates were subjected to the identification experiments based on the biochemical characteristics and the molecular-typing approach, an ITS-PCR, whether they belong to the genus Leuconostoc or not. The data obtained from API 50 CHL kit resulted that six isolates were identified as the members of Leuconostoc and six as Lactobacillus brevis strains except for a single isolate YKI 30-0401, which was not able to be identified because its biochemical traits were not matched to the database of API 50 CHL kit. It was noted that some isolates were distinct in a couple of some biochemical characteristics compared with those of the reference Leuconostoc species. To overcome the limitations experienced in the commercial identification products above, an ITS-PCR experiment was also conducted for the isolates, resulting that eight isolates belong to Leu. mesenteroides ssp. mesenteroides or dextranicum with a single band of 564 bp, and four to L. brevis strains. The ITS-PCR profiles clearly differentiated the closely-related LAB isolates for which same results were obtained by the biochemical method. This molecular approach, however, failed to produce the amplicons for the YKI 20-1003, leaving the strain unidentified. Judging from the identification data obtained in the Kimchi fermented at $4^{\circ}C$ or $10^{\circ}C$, Leuconostoc spp. including Leu. mesenteroides/dextranicum were likely predominant species in the earlier stage and L. brevis occurred at the high level through the whole period. By contrast, L. brevis, as one of the major flora, possibly lead the fermentation from the beginning in the Kimchi fermented at $20^{\circ}C$.}C$.

Studies on Production of Heteropolysaccharide by Mutant of Xanthomonas malvacearum (Xanthomonas malvacearum 돌연변이주(突然變異株)의 Heteropolysaccharide 생산성(生産性)에 관(關)하여)

  • Lee, Ke-Ho;Kim, Mi-Sun;Park, Chan-Yung
    • Applied Biological Chemistry
    • /
    • v.30 no.1
    • /
    • pp.77-87
    • /
    • 1987
  • The mutant with high productivity, X. malvacearum SNUF 560-6, was acquired from the X. malvacearum SNUF 560 with low productivity by UV-light irradiation. It was preserved is lyophilized stock culture and it was transferred to PDA slant to maintain viability fortnightly. Fermentations were started by retransfering to MY agar slant from PDA stok culture. The experiments for optimal xanthan gum production were studied in a chemically defined medium. Of the carbon and nitrogen sources tested, 0.4% sucrose medium and 10mM glutamic acid medium yielded the highest xanthan gun production respectively. The addition of 10g/l succinic acid stimulated xanthan gum production. Also 65mM $PO_4\;^{-3}\;(12.6g/l\;KH_2PO_4)$ was effective on xanthan gum production. Finally, medium 1 and medium 2 which have high xanthan gum production potencies were achieved in this stud. The components of medium 1 and medium 2 were as follows: Medium 1 : sucrose 40g/l glutamate 10mM $PO_4\;^{-3}\;54mM\;(KH_2PO_4\;12.65g/l)$ Citrate 2g/l $MgSO_4{\cdot}7H_2O\;0.2g/l$ $H_3BO_3\;0.005/l$ ZnO 0.006/l $FeCl_2{\cdot}6H_2O\;0.0024g/l$ $CaCO_3\;0.02g/l$ Medium 2 : $Sucrose\;40g/l\;(NH_4)_2SO_4\;2g/l$ $PO_4\;^{-3}\;65mM\;(KH_2PO_4\;12.65g/l)$ Succinate 10g/l $MgSO_4{\cdot}7H_2O\;0.02g/l$ $H_3BO_3\;0.06g/l$ ZnO 0.006g/l $FeCl_2{\cdot}6H_2O\;0.0024g/l$ $CaCO_3\;0.02g/l$.

  • PDF

Evaluation of Site-specific Potential for Rice Production in Korea under the Changing Climate (지구온난화에 따른 우리나라 벼농사지대의 생산성 재평가)

  • Chung, U-Ran;Cho, Kyung-Sook;Lee, Byun-Woo
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.8 no.4
    • /
    • pp.229-241
    • /
    • 2006
  • Global air temperature has risen by $0.6^{\circ}C$ over the last one hundred years due to increased atmospheric greenhouse gases. Moreover, this global warming trend is projected to continue in the future. This study was carried out to evaluate spatial variations in rice production areas by simulating rice-growth and development with projected high resolution climate data in Korea far 2011-2100, which was geospatially interpolated from the 25 km gridded data based on the IPCC SRES A2 emission scenario. Satellite remote sensing data were used to pinpoint the rice-growing areas, and corresponding climate data were aggregated to represent the official 'crop reporting county'. For the simulation experiment, we used a CERES-Rice model modified by introducing two equations to calculate the leaf appearance rate based on the effective temperature and existing leaf number and the final number of leaves based on day-length in the photoperiod sensitive phase of rice. We tested the performance of this model using data-sets obtained from transplanting dates and nitrogen fertilization rates experiments over three years (2002 to 2004). The simulation results showed a good performance of this model in heading date prediction [$R^2$=0.9586 for early (Odaebyeo), $R^2$=0.9681 for medium (Hwasungbyeo), and $R^2$=0.9477 for late (Dongjinbyeo) maturity cultivars]. A modified version of CERES-Rice was used to simulate the growth and development of three Japonica varieties, representing early, medium, and late maturity classes, to project crop status for climatological normal years between 2011 and 2100. In order to compare the temporal changes, three sets of data representing 3 climatological years (2011-2040, 2041-2070, and 2071-2100) were successively used to run the model. Simulated growth and yield data of the three Japonica cultivars under the observed climate for 1971-2000 was set as a reference. Compared with the current normal, heading date was accelerated by 7 days for 2011-2040 and 20 days for 2071-2100. Physiological maturity was accelerated by 15 days for 2011-2040 and 30 days for 2071-2100. Rice yield was in general reduced by 6-25%, 3-26%, and 3-25% per 10a in early, medium, and late maturity classes, respectively. However, mid to late maturing varieties showed an increased yield in northern Gyeonggi Province and in most of Kwangwon Province in 2071-2100.

Evaluation of Skin Dose and Image Quality on Cone Beam Computed Tomography (콘빔CT 촬영 시 mAs의 변화에 따른 피부선량과 영상 품질에 관한 평가)

  • Ahn, Jong-Ho;Hong, Chae-Seon;Kim, Jin-Man;Jang, Jun-Young
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.20 no.1
    • /
    • pp.17-23
    • /
    • 2008
  • Purpose: Cone-beam CT using linear accelerator attached to on-board imager is a image guided therapy equipment. Because it is to check the patient's set-up error, correction, organ and target movement. but imaging dose should be cause of the secondary cancer when taking a image. The aim of this study is investigation of appropriate cone beam CT scan mode to compare and estimate the image quality and skin dose. Materials and Methods: Measurement by Thermoluminescence dosimeter (TLD-100, Harshaw) with using the Rando phantom are placed on each eight sites in seperately H&N, thoracic, abdominal section. each 4 methods of scan modes of are measured the for skin dose in three time. Subsequently, obtained average value. Following image quality QA protocol of equipment manufacturers using the catphan 504 phantom, image quality of each scan mode is compared and analyzed. Results: The results of the measured skin dose are described in here. The skin dose of Head & Neck are measured mode A: 8.96 cGy, mode B: 4.59 cGy, mode C: 3.46 cGy mode D: 1.76 cGy and thoracic mode A: 9.42 cGy, mode B: 4.58 cGy, mode C: 3.65 cGy, mode D: 1.85 cGy, and abdominal mode A: 9.97 cGy, mode B: 5.12 cGy, mode C: 4.03 cGy, mode D: 2.21 cGy. Approximately, dose of mode B are reduced 50%, mode C are reduced 60%, mode D are reduced 80% a point of reference dose of mode A. the results of analyzed HU reproducibility, low contrast resolution, spatial resolution (high contrast resolution), HU uniformity in evaluation item of image quality are within the tolerance value by recommended equipment manufacturer in all scan mode. Conclusion: Maintaining the image quality as well as reducing the image dose are very important in cone beam CT. In the result of this study, we are considered when to take mode A when interested in soft tissue. And we are considered to take mode D when interested in bone scan and we are considered to take mode B, C when standard scan. Increasing secondary cancer risk due to cone beam CT scan should be reduced by low mAs technique.

  • PDF