• Title/Summary/Keyword: 선택과 제거

Search Result 1,492, Processing Time 0.028 seconds

THE STAINLESS STEEL CROWN RESTORATION OF CARIOUS PRIMARY MOLARS WITH HALL TECHNIQUE : A CASE REPORT (Hall technique을 이용한 우식 유구치의 기성 금속관 수복 : 증례보고)

  • Yu, Seong-Goo;Jeong, Tae-Sung;Kim, Shin
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.39 no.2
    • /
    • pp.199-205
    • /
    • 2012
  • Although the stainless steel crowns have been recognized as the most effective and durable form of restoration for primary molars, they have been regarded by many dentists as having definite demerits such as invasive nature of procedural complexity and behavioral aspects of children. As an alternative to conventional technique of stainless steel crown restoration, the Hall technique was first introduced in 1988, which is characterized by just pushing the pre-contoured, cement filled crown form onto the abutment molar with no local anesthesia, no caries removal, no tooth preparation. According to several reports, this can slow, arrest, or even reverse the progress of caries. In addition, its atraumatic feature gives less discomfort and stress to children than conventional one, which is thought excellent especially in younger children. Also, It has been reported to be effective and acceptable to dentist, child patients and their parents. In this case study, three children with age of 4 years 5 months, 4 years 10 months, 6 years 4 months were treated with stainless steel crowns using Hall technique on first primary molar respectively. The teeth were free from pulpal, periapical pathology. After follow up of about 3 to 6 months period, the results showed clinically successful outcomes without any marked complication in pulp, tooth or soft tissue till now. But, it should be kept in mind that this technique is not proper to every child, every carious molar, or every dentist. Thorough distinction of indicated cases and continuous follow-up check is highly required. Conclusively, Hall technique might be an effective and realistic minimally invasive alternative for the carious primary molars especially in younger or disabled children, despite potential doubts on its efficacy and some definite limitations.

Preparation of Asymmetric PES Hollow Fiber Gas Separation Membranes and Their $CO_2/CH_4$ Separation Properties (비대칭구조의 폴리이서설폰 기체분리용 중공사막의 제조 및 이를 이용한 $CO_2/CH_4$ 분리특성)

  • Park, Sung-Ryul;Ahn, Hyo-Seong;Kim, Jeong-Hoon
    • Membrane Journal
    • /
    • v.21 no.4
    • /
    • pp.367-376
    • /
    • 2011
  • Huge amount of $CH_4$ mixtures has been emitted from landfills and organic wastes via anaerobic digestion. The recovery of high purity $CH_4$ from these gases has two merits: reduction of green house gases and production of renewable fuels. Membrane technology based on polymeric materials can be used in this application. In this study, asymmetric gas separation hollow fiber membranes were fabricated to develop the membrane-based bio-gas purification process. Polyethersulfone (PES) was chosen as a polymer materials because of high $CO_2$ permeability of 3.4 barrer and $CO_2/CH_4$ selectivity of 50[1]. Acetone was used as a non-solvent additive because of its unique swelling power for PES and highly volatile character. The prepared PES hollow fiber showed excellent separation properties: 36 GPU of $CO_2$ permeance and 46 of $CO_2/CH_4$ selectivity at optimized preparation conditions: 9wt% acetone content, 10cm air-gap and 4wt% PDMS coating processes. With the PES hollow fiber membranes developed, mixed $CO_2/CH_4$ test was done by changing various operating conditions such as pressures and feed compositions to meet the highest recovery of CH4 with 95% purity. High $CH_4$ recovery of 58 wt% was observed at 10 atm feed pressure for the 50 vol% of $CO_2$ in $CO_2/CH_4$ mixture.

Size and Shape Effect of Metal Oxides on Hydrocarbon Selective Catalytic Reduction of Nitrogen Oxides (금속 산화물 촉매의 크기와 형태에 따른 질소산화물의 탄화수소 선택적 촉매환원 특성)

  • Ihm, Tae-Heon;Jo, Jin-Oh;Hyun, Young Jin;Mok, Young Sun
    • Journal of the Korean Institute of Gas
    • /
    • v.19 no.5
    • /
    • pp.20-28
    • /
    • 2015
  • This work investigated the size and shape effect of ${\gamma}$-alumina-supported metal oxides on the hydrocarbon selective catalytic reduction of nitrogen oxides. Several metal oxides including Ag, Cu and Ru were used as the catalysts, and n-heptane as the reducing agent. For the Ag/${\gamma}$-alumina catalyst, the $NO_x$ reduction efficiency in the range of $250{\sim}400^{\circ}C$ increased as the size of Ag decreased (20 nm>50 nm>80 nm). The shape effect of metal oxides on the $NO_x$ reduction was examined with spherical- and wire-shape nanoparticles. Under identical condition, higher catalytic activity for $NO_x$ reduction was observed with Ag and Cu wires than with the spheres, while spherical- and wire-shape Ru exhibited similar $NO_x$ reduction efficiency to each other. Among the metal oxides examined, the best catalytic activity for $NO_x$ reduction was obtained with Ag wire, showing almost complete $NO_x$ removal at a temperature of $300^{\circ}C$. For Cu and Ru catalysts, considerable amount of NO was oxidized to $NO_2$, rather than reduced to $N_2$, leading to lower $NO_x$ reduction efficiency.

Development and validation of analytical methods for pyrifluquinazon residues determination on agricultural commodities by HPLC-UVD (HPLC-UVD를 이용한 농산물 중 pyrifluquinazon 잔류시험법 개발 및 검증)

  • Do, Jung-Ah;Kwon, Ji-Eun;Kim, Mi-Ra;Lee, Eun-Mi;Kuk, Ju-Hee;Cho, Yoon-Jae;Chang, Moon-Ik;Kwon, Kisung;Oh, Jae-Ho
    • Analytical Science and Technology
    • /
    • v.26 no.3
    • /
    • pp.174-181
    • /
    • 2013
  • Pyrifluquinazon is classified with a quinazoline insecticide that regulates food intake by controling the feeding behavior acting on the endocrine or nervous system of pests such as aphids and white fly. To keep safety on pyrifluquinazon residues in agricultural commodities a simple, accurate and rapid analytical method was developed and validated using high performance liquid chromatograph (HPLC-UVD). The pyrifluquinazon residues acidified with 1% formic acid in samples were extracted with acetonitrile and partitioned with hexane subsequently to dichloromethane then purified with silica solid phase extraction (SPE) cartridge. The purified samples were detected using HPLC-UVD. The method was validated using apple and pear spiked with pyrifluquinazon at 0.02, 0.05 and 0.1 mg/kg and hulled rice, pepper, soybean at 0.05 and 0.1 mg/kg. Average recoveries were 70.5~107.9% with relative standard deviation less than 10%. The result of recoveries and overall coefficient of variation of a laboratory results in Gwangju regional FDA and Daejeon regional FDA was followed with Codex guideline (CODEX CAC/GL 40). This method is appropriated at pyrifluquinazon residues determination and will be used as official method of analysis.

A COMPARISON OF MASTER APICAL FILE SIZE ACCORDING TO INSTRUMENTATION IN TYPE II ROOT CANAL (제2형 근관의 확대에 따른 최종근관장파일 크기의 비교)

  • Jeong, Eun-Ju;Lee, Dong-Kyun;Baek, Shin-Young;Hwang, Ho-Keel
    • Restorative Dentistry and Endodontics
    • /
    • v.33 no.5
    • /
    • pp.435-442
    • /
    • 2008
  • Type II root canal was defined that two canals leave the chamber and merge to form a single canal at short of the apex. The aim of this study was to analyse the master apical file (MAF) size according to various instrumentation techniques in the type II root canal when each canal was enlarged to working length. Eighty mesial roots of molar with ISO #15 initial apical file (IAF) size in type II root canals were randomly divided into four experimental groups with 20 teeth each. According to enlarging instruments, four groups are: K-$FLEXOFILE^{(R)}$ (KF), engine-driven Ni-Ti $P_{RO}T_{APER}{^{(R)}}$ (PT), HERO $Shaper^{(R)}$ (HS), $K^{3\;TM}$ (K3). All canals were enlarged to each working length with ISO #30 size: #30 in KF, F3 in PT, .04/30 in HS, and .06/30 in K3. The master apical file (MAF) size was confirmed by tactile sensation and universal test- ing machine (EZ test, Shimadzu Co., Kyoto, Japan). The mean MAF size was statistically compared using one-way ANOVA and Tukey HSD test at the 0.05 probability level. These results show that the MAF size was appeared one or two sizes larger than the final enlarging instrument when all canal in type II configuration were enlarged to each working length. Therefore, the clinician have to confirm the apical stop once more after instrumentation of type II root canal.

Analytical Methods for Diethylstibestrol and Zeranol in Muscle Foods (근육 식품 중의 diethylstibestrol과 zeranol 분석법)

  • Ha, Jae-Ho
    • Korean Journal of Food Science and Technology
    • /
    • v.34 no.3
    • /
    • pp.385-389
    • /
    • 2002
  • Analytical method for diethylstibestrol (DES) and zeranol, which are growth promoters, in muscle foods was studied. Through selected ion monitoring analysis by GC-MSD for hormones, $M^+$ 412, 420, 416, and 433 for DES, $D_8DES$, ${\beta}-estradiol$, and zeranol, respectively, were selected for quantitative analysis. Removal of interferences in meat was done by passing the meat through 1 cc of strong anion exchanges resin, Dowex $2{\times}8$, 400 mesh, whereby the recoveries of DES and zeranol were achieved. Recoveries of DES and zeranol were ranged from 85 to 110%, and 75 to 110%, respectively, in meat using $D_8DES$ as an internal standard, while were 82 to 105%, and 65 to 120%, respectively, using ${\beta}-estradiol$ as an internal standard. These results show that both $D_8DES$ and ${\beta}-estradiol$ can be adopted as the internal standard for the analysis of DES and zeranol in muscle foods. Limits of detection of DES and zeranol were 0.05 and 1.0 ng/g, and limits of quantitation were 0.5 and 1.0 ng/g, respectively. The results of this study revealed no DES and zeranol were present in 14 samples of beefs, porks, ducks, chickens, mutiplicated flat fish, and trout.

Efficient 3D Object Simplification Algorithm Using 2D Planar Sampling and Wavelet Transform (2D 평면 표본화와 웨이브릿 변환을 이용한 효율적인 3차원 객체 간소화 알고리즘)

  • 장명호;이행석;한규필;박양우
    • Journal of KIISE:Computer Systems and Theory
    • /
    • v.31 no.5_6
    • /
    • pp.297-304
    • /
    • 2004
  • In this paper, a mesh simplification algorithm based on wavelet transform and 2D planar sampling is proposed for efficient handling of 3D objects in computer applications. Since 3D vertices are directly transformed with wavelets in conventional mesh compression and simplification algorithms, it is difficult to solve tiling optimization problems which reconnect vertices into faces in the synthesis stage highly demanding vertex connectivities. However, a 3D mesh is sampled onto 2D planes and 2D polygons on the planes are independently simplified in the proposed algorithm. Accordingly, the transform of 2D polygons is very tractable and their connection information Is replaced with a sequence of vertices. The vertex sequence of the 2D polygons on each plane is analyzed with wavelets and the transformed data are simplified by removing small wavelet coefficients which are not dominant in the subjective quality of its shape. Therefore, the proposed algorithm is able to change the mesh level-of-detail simply by controlling the distance of 2D sampling planes and the selective removal of wavelet coefficients. Experimental results show that the proposed algorithm is a simple and efficient simplification technique with less external distortion.

Treatment of Cerebral Arteriovenous Malformations by Preoperative Embolization and Microsurgery (술전 색전술과 미세수술을 이용한 뇌동정맥기형의 치료)

  • Kim, Kyu Hong;Rho, Myung Ho;Lee, Woon Gi;Choi, Jeong Hoon;Lee, In Chang;Bae, Sang Do
    • Journal of Korean Neurosurgical Society
    • /
    • v.29 no.4
    • /
    • pp.500-506
    • /
    • 2000
  • Objective : To determine the role of preoperative embolization on postoperative neurological outcome in the treatment of cerebral AVMs, we retrospectively evaluated an effectiveness of combining preoperative embolization and microsurgery for arteriovenous malformations(AVM) of the brain. Method : Two groups(10 patients who underwent preoperative superselective embolization and surgery versus 27 patients who underwent surgery only) were compared and categorized by Spetzler-Martin grade, the size of AVM and postoperative clinical outcome using Glasgow Outcome Scale. The 37 patients included 23 males and 14 females, ranging in age from 11 to 74 years(mean 36 years). Results : The arteriovenous malformations in preoperative embolization and surgery group had a larger average greatest diameter(4.45cm versus 3.83cm) and were of higher Spetzler-Martin grade(80% versus 52% grade III through V). At 1 week after surgery, the preoperative embolization and surgery group represented a better outcome(60% versus 44% with Glasgow Outcome Scale score of 5). And over 6 months after surgery, the embolization and surgery group displayed more favorable clinical outcome(80% versus 63% with Glasgow Outcome Scale score of 5). Conclusion : Combined treatment with superselective preoperative embolization using N-butyl cyanoacrylate and direct surgery may help neurosurgeon treating the high grade AVMs thus improving the postsurgical outcome.

  • PDF

An analysis of benzoic acid, methyl paraben and butyl paraben in soy sauce using isotope dilution liquid chromatography mass spectrometry (동위원소희석 질량분석법을 이용한 간장 중의 안식향산, 메틸파라벤, 부틸파라벤의 분석)

  • Ahn, Seonghee
    • Analytical Science and Technology
    • /
    • v.31 no.6
    • /
    • pp.225-231
    • /
    • 2018
  • Benzoic acid, methyl paraben, and butyl paraben are preservatives that have been used in pharmaceutical, cosmetic, and food products. However, as their toxicities for human have been reported, many nations and organizations including Korea have established a regulation limit for thier usage of these preservatives in food products. The present study developed the isotope dilution liquid chromatography mass spectrometry method for accurate determination of three target preseratives in soysauce. In this study, the isotope dilution liquid chromatography mass spectrometry method was developed for accurate determination of three target preservatives in soy sauce. LC separation was optimized considering the pKa of benzoic acid which is lower than those of methyl and butyl parabens. A C18 column was used with 5 mM ammonium acetate and methanol as mobile phases. Mass spectrometry was operated in negative mode and selected reaction monitoring mode (SRM). Soy sauce sample was cleaned-up with C18 SPE cartridge for removing matrix inferences and color material. Optimized conditions and the method were validated with soy sauce reference materials for the analysis of food preservatives from Health Science Authority in Singapore. The measured values of benzoic acid, methyl and butyl paraben agreed well with reference values within their uncertainties.

A Reaction Kinetic for Selective Catalytic Reduction of NOx with NH3 over Manganese Oxide (NMO, MnO2, Mn2O3) at Low Temperature (망간산화물(NMO, MnO2, Mn2O3)을 이용한 저온에서의 NH3-SCR의 반응속도 연구)

  • Kim, Min Su;Hong, Sung Chang
    • Clean Technology
    • /
    • v.24 no.4
    • /
    • pp.307-314
    • /
    • 2018
  • In this study, NMO (Natural Manganese Ore), $MnO_2$, and $Mn_2O_3$ catalysts were used in the selective catalytic reduction process to remove nitrogen oxides (NOx) using $NH_3$ as a reducing agent at low temperatures in the presence of oxygen. In the case of the NMO (Natural Manganese Ore), it was confirmed that the conversion of nitrogen oxides in the stability test did not change even after 100 hours at 423 K. The Kinetics experiments were carried out within the range where heat and mass transfer were not factors. From a steady-state Kinetics study, it was found that the low-temperature SCR reaction was zero order with the respect to $NH_3$ and 0.41 ~ 0.57 order with the respect to NO and 0.13 ~ 0.26 order with the respect to $O_2$. As temperature increases, the reaction order decreases as a result of $NH_3$ and oxygen concentration. It was confirmed that the reaction between the $NH_3$ dissociated and adsorbedon the catalyst surface and the gaseous nitrogen monoxide (E-R model) and the reaction with the adsorbed nitrogen monoxide (L-H model) occur.