• Title/Summary/Keyword: 선원훈련

Search Result 61, Processing Time 0.025 seconds

A Study on Human Factor for Port State Control System (항만국통제제도에 대한 인적요인 연구)

  • Lee, Yun-Cheol;Kim, Jin-Kwon;Jeon, Hae-Dong
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.108-109
    • /
    • 2005
  • The aim of Port State Control(PSC) system is recognized as a proficient mechanism in preventing coastal traffic accident and protecting marine environment. Recently, PSC system is focused on human factor of International Maritime Convention, especially ILO and STCW Convention by considering many accidents resulted from human factor. Therefore, we have to understand of Consolidated Maritime Labour Convention which describes employment conditions and social welfare policy, the rights about the lowest wages, the overdue wages, the unemployment protection. a disaster reward, etc and STCW Convention which describes standards of training, certification and watchkeeping for seafarers. The aim of this study is to recognize inspection points about human factor of these Conventions. .

  • PDF

해난사고 분석을 위한 Full-mission Shiphandling Simulator(FMSS)시연

  • Lee, Dong-Seop;Gang, Jeong-Gu
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2011.06a
    • /
    • pp.87-88
    • /
    • 2011
  • 다기능 선박조종시뮬레이터(Full-mission Shiphandling Simulator)를 이용한 사고분석 방법을 한국해양수산연수원이 보유한 DNV(Det Norske Veritas)선급에서 "Integrated Simulator System, NAUT AW(SIM), DYNPOS-AUT(SIM), HSC, TUG, ICE" Class로 인정하고, STCW 협약 Regulation I/12를 충족한 Russia TRANSAS사의 "NAVI-TRAINER PROFESSIONAL 5000 NTPRO 5000" Full-mission Shiphandling Simulator를 이용하여 시행하였다.

  • PDF

해난사고 분석을 위한 Full-mission Shiphandling Simulator(FMSS) - 한국해양수산연수원 FMSS를 기준으로 -

  • Lee, Dong-Seop
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2011.06a
    • /
    • pp.71-73
    • /
    • 2011
  • 다기능 선박조종시뮬레이터(Full-mission Shiphandling Simulator)는 항해사, 선장 및 도선사의 자질 향상을 위한 교육뿐만 아니라 항만개발을 위한 사전 검토와 해난사고 발생 시, 원인규명을 위한 분석에도 이용되고 있다. 한국해양수산연수원에서는 이러한 목적을 위하여 2011년 2월 28일 Russia Transas 제품의 선박조종시뮬레이터를 설치 완료 하였다. 이 FMSS는 적어도 360도의 수평시각을 가진 대형 구형화면에 여섯(6) 자유도 운동을 하는 본선 및 타선을 실시간으로 표현하는 photo-realistic high resolution computer graphic visual system과 같은 최신기술을 사용하는 가장 현대화된 최고급 해상용 시뮬레이터로 해난 사고 윈인규명을 위한 분석 연구 목적을 위하여 광범위한 출처로부터 모델시험과 자료의 신뢰할만한 공식적 기록들에 근거한 매우 정확한 수력학적 선박 모델링 소프트웨어로 이루어졌다. 여기서는 이 FMSS의 형태와 복잡성을 상세하게 소개한다.

  • PDF

항해설비 표준모드 적용을 위한 개발 방안 연구

  • Jeong, Min;An, Yeong-Jung;Chae, Byeong-Geun
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2015.10a
    • /
    • pp.181-183
    • /
    • 2015
  • 2015년 6월 IMO MSC 95차에서 항해설비에 표준모드 적용을 위한 S-Mode 가이드라인 개발이 2019년까지의 e-Navigation 주요개발 과제로 승인되었다. S-Mode는 주요 사용자인 항해사, 선장 및 도선사에게 표준화된 화면, 기능 제공을 통해 친숙한 업무환경을 통해 상황인식에 기여함으로써 항해안전성을 향상시키고, 교육 훈련 측면에서 선원의 부담을 경감시키기 위한 목적으로 개발 예정이다. 주요 선상사용자요구사항에 기반하여 항해설비에 표준화된 화면 및 메뉴가 적용됨으로써, 인적 측면에서의 개선이 이루어 질 것으로 예상된다. 본 연구에서는 IMO에서의 S-Mode 논의 동향을 분석하였고, S-Mode 주요 표준화 항목 도출을 위한 개발 방안을 연구하였다.

  • PDF

골든레이호 전도사고 원인 분석

  • 김득봉;김진수;정창현;윤병원
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2022.11a
    • /
    • pp.154-154
    • /
    • 2022
  • 2019년 9월 8일 자동차운반선 골든레이호가 미국 브런즈윅항(Brunswick)항에서 출항 도중 전도되는 사고를 입었다. 도선사와 선원 23명은 모두 구조되었으나, 사고선박은 복구 불가로 전손(해체)처리 되었다. 미연방교통안전위원회(NTSB)는 담당사관이 선박 복원성 계산 프로그램에 평형수 양을 잘못 입력하였고, 충분한 GM 부족으로 선회 중 발생한 경사모멘트에 대응하지 못해 전도된 것으로 추정하였다. 우리나라 중앙해양안전심판원의 특별조사부에서도 미국과 동일한 원인에 의해 전도된 것으로 판단하였다. 본 연구에서는 골든레이호와 유사한 선박을 대상으로 상황별 GM를 계산하였고, 상황별/속력별 최대 횡경사각을 계산하였다. 선속 10노트 이하에서는 GM값이 작은 상황에서도 전도 위험은 높지 않았다. 다만, 13노트 이상이 되면 20도 이상의 횡경사각이 발생하여 전도 위험이 높아짐을 알 수 있었다. 이번 골든레이호 전도사고와 같은 사고를 방지하기 위해서는 담당사관이 복원성 계산능력을 충분히 갖출 수 있도록 복원성에 대한 교육 및 훈련을 강화할 필요가 있으며, 복원성 계산과정에서 발생할 수 있는 오류를 확인하기 위한 검증 절차를 선박과 회사에서 마련할 필요가 있다.

  • PDF

A study on the location of fire fighting appliances in cargo ships (화물선 소화설비 비치에 대한 연구)

  • Ha, Weon-Jae
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.40 no.9
    • /
    • pp.852-858
    • /
    • 2016
  • To safeguard the accommodation spaces on cargo ships from fire, structural fire protection provisions introduced by SOLAS and these measures retard the propagation of flames and smoke. SOLAS also specifies provisions for fire fighting drills. These provisions are a combination of regulations regarding structure and equipment and those dealing with the human element for the fire protection and effective responses in the event of fire. Requirements related to the human element play a supporting role to the requirements for structure and equipment because the present accommodation structure and equipment are insufficient for extinguishing a fire, therefore, fire-extinguishing activity performed by crew members is essential. To reduce human error and ensure effective fire fighting, it is necessary to install a fire-fighting system and improve the fire fighting process. The fundamental concept of fire fighting exercises is to commence fire fighting before the fire grows too big to extinguish. It is essential to relocate the storage place of fire fighting equipment to expedite the fire-fighting exercise. This study was carried out to reduce human risk for this purpose, the fire control station was relocated to a site that could be accessed from the open deck. Further, two sets of a fire fighter's outfit were stored at the same site. This relocation eliminated the risk of the crew reentering to operate the fire fighting system in the fire control station and allowed the crew to pick up the fire fighters' outfits quickly in the event of a fire. In addition, it was proposed that the IIC method be made mandatory. This method is combination of automatic fire detection system and sprinkler system which can reduce the risk of the fire fighting exercises for the crew and to suppress fire in the initial stage. This study was carried out to provide a foundation to the possible amendment of the relevant SOLAS regulations and national legislation.

Measuring external Radiation dose Ratio by Traits of Patients during Positron Emission Tomography(PET) (양전자단층촬영(PET)시 환자의 특성에 따른 외부 방사선량률 측정)

  • Cho, Yong-Gwi;Kim, Sung-Chul;Ahn, Sung-Min
    • The Journal of the Korea Contents Association
    • /
    • v.13 no.12
    • /
    • pp.860-868
    • /
    • 2013
  • The purpose of this study is to ensure safety by measuring External radiation dose ratio (ERDR) by traits of patients in many ways after administering radiopharmaceutical($^{18}F$-FDG) for PET Torso scan, and to decrease ERDR of those to RI technologist, caretakers, and those who frequently exposed to radiation by arousing attention to radiation dose. Radiopharmaceutical was administered to 80 patients who conducted PET Torso from January to June, 2013. Radiation dose emitted from the patients was measured according to body shape(BMI), water hydration, height, amount of radiation administration. From the moment immediately after the radiopharmaceutical was administered, ERDR was measured by personal traits of patients. The radiation dose increased in proportion to the administered amount of the radiopharmaceutical, and there was no significant difference depending on the body shape of the patients. When water was supplied and the height was normal, the radiation dose was lower compared with the cases where water was not supplied and height was not normal. There is a need for making efforts to minimize the working time through sufficient education and mock training before those who RI technologist with sources of radiation for complying the radiation safety management rule. And they should minimize the ERDR by wearing a protective gear.

An Empirical Study on the Satisfaction of Shipboard Training for Marine Engineering Part Cadets: The Case of Korea Maritime University (실습생의 승선실습 교육의 만족도에 관한 실증연구 -기관계열 실습생의 실습선 교육을 중심으로-)

  • 김성국
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.22 no.2
    • /
    • pp.146-173
    • /
    • 1998
  • It is one of the most important factors Seafarers Education Quality Assurance and management in Higher Maritime Education Institution. The educational process and result of Higher Maritime Educational Institution. The educational process and result of Higher Maritime Educational Institution should be evaluated according to the 1995 Amendments to the International Convention on Standards of Training Certification and Watchkddping for Seafares(STCW) 1978. Actuall above-mentioned evaluation is deemed to make foundation in order to enhance the efficiency of shipboard education by surveying the satisfaction of shipboard training for Marine Engineering part cadets by the group. In this paper we carried out the questionnaire survey to study stisfactory value and the reason of dissatisfaction of 89 cadets being trained on board the Training Ship in Maritime College of Korea Maritime University The results were calculated by frequency and percentage; the significance of difference among Department groups like Marine Engineering Maritime polic and Ship Operating Systems Engineering Engineering was analysed by $x^2$ inspection.

  • PDF

Strategies for Advancement of response management system on marine pollution (해양오염 방제체제의 선진화 방안)

  • Kim Dae Won
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.3 no.1
    • /
    • pp.3-24
    • /
    • 2000
  • The provability of major oil spill acidents around Korean coast is very high due to increase of sea traffic and decrease of quality of ships crews and increase of the old-ship. The Strategies of establishment of a advanced response management system against this mass pollution incident are as follows;. 1. Development of Regional Contingency Plan, which is scientifically illuminated, in order to implement the National Contingency Plan efficiently. 2. Early completion of a national response capability twenty thousand tons. 3. To strengthen training and exorcise specialized in the field of marine pollution response. 4. Establishment of a system of response cooperation among neighbor countries by promoting the NOWPAP tasks etc. The response policy in the 21th century should be concentrated to promote a practicle response capability through response operation scientifically specialized and internationalized by establishing the advanced response system early.

  • PDF

The Study of Radiation Reducing Method during Injection Radiopharmaceuticals (방사성의약품 투여 시 피폭선량 저감에 대한 연구)

  • Cho, Seok-Won;Jung, Seok;Park, June-Young;Oh, Shin-Hyun;NamKoong, Hyuk;Oh, Ki-Beak;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.1
    • /
    • pp.80-85
    • /
    • 2012
  • Purpose: The whole body bone scan is an examination that visualizing physiological change of bones and using bone-congenial radiopharmaceutical. The patients are intravenous injected radiopharmaceutical which labeled with radioactive isotope ($^{99m}Tc$) emitting 140 keV gammarays and scanned after injection. The 3 principles of radiation protection from external exposureare time, distance and shielding. On the 3 principles of radiation protection basis, radiopharmaceutical might just as well be injected rapidly for reducing radiation because it might be the unopened radiation source. However the radiopharmaceuticals are injected into patient directly and there is a limitation of distance control. This study confirmed the change of radiation exposure as change of distance from radiopharmaceutical and observed the change of radiation exposure afte rsetting a shelter for help to control radio-technician's exposure. Materials & methods: For calculate the average of injection time, the trained injector measured the injection time for 50 times and calculated the average (2 minutes). We made a source as filled the 99mTc-HDP 925 MBq 0.2 mL in a 1 mL syringe and measured the radiation exposure from 50 cm,100 cm,150 cm and 200 cm by using Geiger-Mueller counter (FH-40, Thermo Scientific, USA). Then we settled a lead shielding (lead equivalent 6 mm) from the source 25 cm distance and measured the radiation exposure from 50 cm distance. For verify the reproducibility, the measurement was done among 20 times. The correlation between before and after shielding was verified by using SPSS (ver. 18) as paired t-test. Results: The radiation doses according to distance during 2 minutes from the source without shielding were $1.986{\pm}0.052{\mu}$ Sv in 50 cm, $0.515{\pm}0.022{\mu}$ Sv in 100 cm, $0.251{\pm}0.012{\mu}$ Sv in 150 cm, $0.148{\pm}0.006{\mu}$ Sv in 200 cm. After setting the shielding, the radiation dose was $0.035{\pm}0.003{\mu}$ Sv. Therefore, there was a statistical significant difference between the radiation doses with shielding and without shielding ($p$<0.001). Conclusion: Because the great importance of whole body bone scan in the nuclear medicine, we should make an effort to reduce radiation exposure during radiopharmaceutical injections by referring the principles of radiation protection from external exposure. However there is a limitation of distance for direct injection and time for patients having attenuated tubules. We confirmed the reduction of radiation exposure by increasing distance. In case of setting shield from source 25 cm away, we confirmed reducing of radiation exposure. Therefore it would be better for reducing of radiation exposure to using shield during radiopharmaceutical injection.

  • PDF