• Title/Summary/Keyword: 선상비교시험

Search Result 19, Processing Time 0.028 seconds

Study on Penetration Performance of Precision Linear Shaped Charge (정밀선상성형장약의 침투·관통 성능에 관한 연구)

  • Lee, Si-Eun;Lee, Juho;Moon, Mi-Ae
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.47 no.6
    • /
    • pp.397-404
    • /
    • 2019
  • Linear Shaped Charge (LSC) that is widely used as separation system in aerospace system has to charge lots of explosives due to lack of uniformity. In addition, it is hard to optimize shape of liner and explosives because of manufacturing process. In order to overcome aforementioned drawbacks, Precision Linear Shaped Charge (PLSC) is currently under development. PLSC is made in two steps: prepare liner independently and charge explosive uniformly. In this study, PLSC is designed to have proper amount of explosives and penetration test of PLSC with different stand-off distance from liner to target is conducted to confirm penetration performance. Based on the penetration test results of PLSC, the numerical analysis method using AUTODYN is established and verified. Penetration mechanism and characteristics of PLSC is analyzed from the numerical and experimental results.

On Board Comparison of Total Hydrogen Ion Concentration (pH) and Total Alkalinity Measurements in Seawater (해수의 총수소이온농도(pH)와 총알칼리도 측정방법에 대한 선상 비교 연구)

  • Kang, Dong-Jin;Tishchenko, Pavel Ya;Kahng, Sung-Hyun
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.14 no.3
    • /
    • pp.205-211
    • /
    • 2011
  • On board comparison of pH and total alkalinity measurement in seawater was carried out during the JES expedition on R/V Roger Revelle in the East Sea using 550 real seawater samples from the surface to the bottom. Spectrophotometry and potentiometry without liquid junction were compared for pH measurement. The pH values of two methods are generally in a good agreement. Spectrophotometry with a pipette provides higher value compare with the potentiometry in the deep layer, where pH values are lower. However, spectrophotometry without a pipette shows same values with potentiometry within their precision range. The pipetting procedure may remove of $CO_2$ in the sample, which causes increase of pH. Potentiometric titration methods using a closed-cell and an open-cell were compared for the total alkalinity measurement. Values from open cell method are smaller by about 5~10 ${\mu}mol\;kg^{-1}$ than those from closed cell method. This may be caused by the bubble formed in the closed cell during the experiment. Although any analytical method compared in this study for the pH or TA measurement can be applied, special attentions should be paid for satisfactory results.

인장시편 및 응력동결된 디스크의 프린지 상수 측정에 의한 다목적 편광기 성능시험

  • Baek, Tae-Hyun;Kim, Myung-Soo;Kim, Dong-Hyun;Lee, Chun-Tae;Kim, Hwan;Park, Tae-Geun
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.05a
    • /
    • pp.178-178
    • /
    • 2004
  • 본 연구에서는 폴리카보나이트의 재료로 만들어진 인장시편과 원형시편을 다목적 광탄성 측정기를 사용하여 프린지 차수를 측정한 후 프린지 상수를 도출하였다. 특히, 새로 개발된 다목적 광탄성기를 이용하여 지랫대 형식으로 프린지 차수를 측정하였고, 시편에 직접 응력을 가하는 방식의 직접(DIRECT) 실험법으로 프린지 차수를 측정하였다. 위와 같은 방식은 나타난 결과를 가지고 프린지 상수를 서로 비교할 수 있다는 장점이 있어 다목적 광탄성기에 대한 신뢰도를 얻을 수 있다 아울러 광탄성 4단계 위상 이동법에서는 주응력 방향, 즉 등경선이 일정한 선상에서는 연속적인 응력분포를 얻을 수 있다.(중략)

  • PDF

Effect of Serrated Disk of Electrostatic Rotary Atomizer on Transfer Characteristics (정전 회전무화형 도장기기의 빗살무늬 디스크가 도착성능에 미치는 영향)

  • Cha, SangWon;Lee, Chan;Ko, YongSeo
    • Clean Technology
    • /
    • v.8 no.1
    • /
    • pp.45-51
    • /
    • 2002
  • The effect of outer edge serrations of a rotating disk in the electrostatic rotary atomizer has been experimentally investigated. In this study, the edge serrations of the rotating disk are designed and fabricated to maintain the ligament atomization for wide range of paint flow rates. A series of experiments have been conducted using optimally-designed or off-designed disks to investigate the surface characteristics, i.e., transfer efficiencies, thicknesses and bubbles. The optimally-designed disk has experimentally shown the best surface characteristics compared to other disks, especially for an existing non-serrated disk.

  • PDF

A Study on the Interpolation Methods for the Laboratory Compaction Test Results (흙의 실내(室內)다짐시험결과(試驗結果)에 대한 해석적(解析的)인 산정(算定)에 관한 연구(研究))

  • Lee, Ho Choon
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.12 no.2
    • /
    • pp.169-175
    • /
    • 1992
  • The Maximum Dry Density (${\gamma}_{dmax}$) and the Optimum Moisture Content (${\omega}_{opt}$) of the soil samples are determined from the compaction curve plotted with the laboratory compaction test results. But in this study three reported tests, and tests on the silty clay and the sandy silt samples are reviewed through the interpolation methods using an equation of the Moisture-Density relations induced from Lagrange's Interpolation Formula without drawing the compaction curves. As the results of the study ${\gamma}_{dmax}$ and ${\omega}_{opt}$, were calculated rapidly and simply using the equation and approached to the results from the compaction curves, and also due to the differences of the ${\gamma}_{dmax}$ and ${\omega}_{opt}$, calculated from the equation between the compaction curves were within $0.01g/cm^3$(0.5%) and 0.4% respectively the method in this study be recommended as a simple method determining ${\gamma}_{dmax}$ and ${\omega}_{opt}$, during the laboratory compaction tests.

  • PDF

Comparison of Flow Characteristics for the Development of a C-Type Strainer with Its Inlet and Outlet on a Straight Line (유입·유출구가 일직선상인 C형 스트레이너 개발을 위한 유동특성 비교)

  • Shin, Byung-kyun;Kwon, Chang-Hee
    • Journal of Digital Convergence
    • /
    • v.14 no.11
    • /
    • pp.257-265
    • /
    • 2016
  • The purpose of this study was to develop a strainer that could protect a flow system by blocking the introduction of foreign substances into the pipe of industrial or architectural facilities. Strainers are installed at the front tip of valves, machines, or pumps in the piping line of clean water, oil, or gas. There are Y-type, U-type, and T-type strainers. The study identified problems with the Y-type strainers, develop a "C-type strainer with its inlet and outlet on a straight line" as a more improved new model, and compared them in functions in a full-scale strainer test. The study conducted a full-scale strainer test according to four situations at the flow laboratory of Korea Research Institute of Standards and Science by using the old Y-type strainer and C-type strainer 50A. The test results show that the C-type strainer had a higher capacity coefficient(Kv) than the Y-type one, recording 74.9% when there was no screen, 54.5% when there were no foreign substances in the screen, 54.2% when there was a 15% accumulation of foreign substances, and 52.4% when there was a 30% accumulation of foreign substances. The investigator conducted a test only with the 50A type due to the limitations of life-size strainers, but the results demonstrate that the C-type strainer had better flow characteristics than the Y-type one.

A Development of Embankment Stability Evaluation Method on Soft Foundation (연약지반상의 흙쌓기 안정관리 기법 개발)

  • Kim, Jeong-Seon;Chang, Yong-Chai;Park, Sung-Su
    • Journal of the Korean Geotechnical Society
    • /
    • v.29 no.9
    • /
    • pp.43-54
    • /
    • 2013
  • This study proposed a new embankment stability control method to analyze the measurement data on the slope activities of the soft ground, using the Stability Control Index (SCI) obtained from the p-q stress paths. In order to validate this new technique, the data from triaxial compression tests (CU) and field measurement were compared. SCI is calculated from the current path of the effective stress points ($p^{\prime}=p-{\Delta}u$) using the relative position between the Total Stress Path $p_{max}$ and the point of $k_f$ line $p_f$. From this result, the point of effective stress $p^{\prime}(=p-{\Delta}u)$ will have access to the point $p_f$ of $k_f$ line when the pore water pressure occurs or the point of total stress pass $p^{\prime}_{max}$ when the pore pressure dissipates. Thus, the Stability Control Index (SCI) can evaluate quantitatively the safety of embankment from the relative position of the effective stress path.

Implementation Algorithms and Performance Analysis of Maritime VHF Data System Based on Filtered Multi-Tone Modulation (FMT 변조 기반의 해상 초단파 데이터 시스템의 구현 알고리즘 및 성능분석)

  • Park, Ok-Sun;Ahn, Jae-Min
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.38C no.3
    • /
    • pp.254-262
    • /
    • 2013
  • This paper proposes FMT(Filtered Multi-Tone)-based digital radio implementation algorithms and the results obtained by various field tests especially in terms of transmitter characteristics. In this study, we predefined frame structure and protocols used for the CSTDMA(Carrier Sensing Time Division Multiple Access) scheme, designed digital filters and RF front end to fulfill the system characteristics such as the spectral mask and processing delays given by the Recommendation ITU-R M.1842-1. The proposed system supports exchange of data for e-Navigation with the usage of wider channel of 50-100kHz bandwidth, Turbo coding and FMT modulation. Furthermore, the common Ethernet protocol makes connection to local WLAN(Wireless Local Area Network) on board the ship for other data services.

On the Derivation of Material Constants Associated with Dynamic Behavior of Heat Formed Plates (열성형 판 부재의 동적거동에 관련된 재료상수 산출에 관한 연구)

  • Lee, Joo-Sung;Lim, Hyung-Kyun
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.29 no.2
    • /
    • pp.105-114
    • /
    • 2016
  • When impact load is applied to a plate structure, a common phenomenon that occurs in structures is plastic deformation accompanied by a large strain and eventually it will experience a fracture accordingly. In this study, for the rational design against accidental limit state, the plastic material constants of steel plate which is formed by line heating and by cold bending procedure have been defined through the numerical simulation for the high speed tension test. The usefulness of the material constants included in Cowper-Symonds model and Johnson-Cook model with the assumption that strain rate can be neglected when strain rate is less than the intermediate speed is verified through comparing the present numerical results with those in references. This paper ends with describing the future study.

An Experimental Study of Characteristics of Plate Deformation by Heating Process (열간가공에 의한 판의 변형특성에 관한 실험적 연구)

  • Chang-Doo Jang;Dae-Eun Ko;Byeong-Il Kim;Jeong-Ung Park
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.38 no.2
    • /
    • pp.62-70
    • /
    • 2001
  • As the ship hull is a compound-curved structure, plate bending process is indispensible. The process includes press bending process for forming major 1st curvature and heating process for forming the rest curvature. Especially the heating process that is above 50 percents of entire bending work is carried out exclusively by skillful workers. Many researches have been made to automate the heating process but most of these are about line heating process and researches for triangle heating process are rare. This study is a fundamental study to develop a efficient analysis method for triangle heating and focused on clarifying the deformation characteristics of plate by triangle heating. In this paper, we carried out heating experiments and analysed the deformation characteristics of plate to explain the deformation characteristics of plates rationally by showing the phase transformed high temperature region. Also we investigated the heating effect on the hull material properties by mechanical tests.

  • PDF