• Title/Summary/Keyword: 선박 검출

Search Result 111, Processing Time 0.025 seconds

A Design Experience of Propeller Open Water Testing Dynamometer (소형 프로펠러 단독시험기 설계)

  • J.S. Kim;M. Song;H. Kim
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.32 no.4
    • /
    • pp.48-54
    • /
    • 1995
  • A new propeller open water testing device is developed and tested in a tow tank. The devised dynamometer consists of a torque measuring part, a thrust measuring part and a driving motor with an RPM counter. Torque is designed to be measured directly from the torsion of the structure holding the motor by using strain gauges and, consequently, conventional slip ring is removed. Also, in order to make the device fit in relatively small model ships, the weight and the size of the whole integrated structure are reduced in various ways. The developed tester is proved to be easily utilized in small circulating water channel experiments and is believed to have provided us with essential information for future design of various types of conventional or object oriented force measuring device.

  • PDF

A Study on the Ship's Heading Stabilization of GPS Compass Using Electromagnetic Compass (전자자기 컴퍼스를 이용한 GPS 컴퍼스의 선수방위 안정화에 관한 연구)

  • Jo, Hyeon-Jeong;Shin, Hyeong-Il;Lee, Dae-Jae;Hyun, Yun-Ki;Bae, Mun-Ki;Kim, Kwang-Sik
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.41 no.1
    • /
    • pp.70-77
    • /
    • 2005
  • The study was results obtained from the trial make of the hybrid GPS-electromagnetic(EM) compass which overcome shortcoming of GPS compass and EM compass. The results were summarized as follows: GPS compass detected the stable ship's heading at 0.1^{\circ}$ intervals with the turning angular velocity of less than 25^{\circ}$/sec in the experiment for the characteristics of turning angular velocity with stepmotor, but in case of over 25^{\circ}$/sec the compass did not detect it. On the contrary, the EM compass always indicated the ship's heading with no connection of the turning angular velocity, however the compass is low accuracy compared with GPS one owing to a compass error. The ship's headings by the hybrid GPS-EM compass were displayed at fixed point and moving by car; if the GPS compass work the headings were displayed by GPS compass, if not, the heading is provided stably by adding or subtracting of a compass error to the heading of EM compass. Also, each ship's heading was derived from not only the GPS compass but also the EM one by add or subtract of the compass errors, and then was worked covariance for the analogy. The results show that the ship's heading of two compasses has been verified the similarity to 95% confidence level.

The analysis of ethylene glycol and metabolites in biological specimens (생체시료에서 에틸렌 글리콜과 그 대사체 분석에 관한 연구)

  • Park, Seh-Youn;Kim, Yu-Na;Kim, Nam-Yee
    • Analytical Science and Technology
    • /
    • v.24 no.2
    • /
    • pp.69-77
    • /
    • 2011
  • Ethylene glycol (EG) is produced commercially in large amounts and is widely used as antifreeze or deicing solution for cars, boats, and aircraft. EG poisoning occurs in suicide attempts and infrequently, either intentionally through misuse or accidental as EG has a sweet taste. EG has in itself a low toxicity, but is in vivo broken down to higher toxic organic acids which are responsible for extensive cellular damage in various tissues caused principally by the metabolites glycolic acid and oxalic acid. The most conclusive analytical method of diagnosing EG poisoning is determination of EG concentration. However, victims are sometimes admitted at a late stage to hospitals or died during emergency treatment like a gastric lavage or found rotten dead, when blood EG concentrations are low or not detected. Therefore, in this study, the identification of EG was not only performed by gas chromatograpyc-mass spectrometry (GC-MS) following derivatization but also further toxicological analyses of metabolites, glycolic acid (GA) and oxalic acid (OA), were performed by ion chromatography in various biological specimens. A ranges of blood concentrations (3 cases) was $10\sim2,400\;{\mu}g/mL$ for EG, $224\sim1,164\;{\mu}g/mL$ for GA and ND $\sim40\;{\mu}g/mL$ for OA, respectively, In other biological specimens (liver, kidney, bile and pleural fluid), a range of concentrations (3 cases) was ND $\sim55,000\;{\mu}g/mL$ for EG, ND $\sim1,124\;{\mu}g/mL$ for GA and ND $\sim60\;{\mu}g/mL$ for OA, respectively. Liver and kidney tissues were recommended specimens including blood because OA, a final metabolite of EG, was identified large amounts in these despite no detectable EG caused by some therapy.

Packaging Technology for the Optical Fiber Bragg Grating Multiplexed Sensors (광섬유 브래그 격자 다중화 센서 패키징 기술에 관한 연구)

  • Lee, Sang Mae
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.24 no.4
    • /
    • pp.23-29
    • /
    • 2017
  • The packaged optical fiber Bragg grating sensors which were networked by multiplexing the Bragg grating sensors with WDM technology were investigated in application for the structural health monitoring of the marine trestle structure transporting the ship. The optical fiber Bragg grating sensor was packaged in a cylindrical shape made of aluminum tubes. Furthermore, after the packaged optical fiber sensor was inserted in polymeric tube, the epoxy was filled inside the tube so that the sensor has resistance and durability against sea water. The packaged optical fiber sensor component was investigated under 0.2 MPa of hydraulic pressure and was found to be robust. The number and location of Bragg gratings attached at the trestle were determined where the trestle was subject to high displacement obtained by the finite element simulation. Strain of the part in the trestle being subjected to the maximum load was analyzed to be ${\sim}1000{\mu}{\varepsilon}$ and thus shift in Bragg wavelength of the sensor caused by the maximum load of the trestle was found to be ~1,200 pm. According to results of the finite element analysis, the Bragg wavelength spacings of the sensors were determined to have 3~5 nm without overlapping of grating wavelengths between sensors when the trestle was under loads and thus 50 of the grating sensors with each module consisting of 5 sensors could be networked within 150 nm optical window at 1550 nm wavelength of the Bragg wavelength interrogator. Shifts in Bragg wavelength of the 5 packaged optical fiber sensors attached at the mock trestle unit were well interrogated by the grating interrogator which used the optical fiber loop mirror, and the maximum strain rate was measured to be about $235.650{\mu}{\varepsilon}$. The modelling result of the sensor packaging and networking was in good agreements with experimental result each other.

The Study on the Marine Eco-toxicity and Environmental Risk of Treated Discharge Water from Ballast Water Management System using Plasma and MPUV (Plasma와 MPUV를 이용한 평형수관리장치의 배출수에 대한 해양생태독성 및 해양환경위해성에 관한 연구)

  • Shon, M.B.;Son, M.H;Lee, J.;Lee, S.U.;Lee, J.D.;Moon, C.H.;Kim, Y.S.
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.15 no.4
    • /
    • pp.281-291
    • /
    • 2012
  • In this study, WET (whole effluent toxicity) test with Skeletonema costatum, Tigriopus japonicus and Paralichthys olivaceus and ERA (environmental risk assessment) were conducted to assess the unacceptable effect on marine ecosystem by emitting the treated discharge water from 'ARA Plasma BWTS' BWMS (ballast water management system) using filtration, Plasma and MPUV module. 34 psu treated discharge water from ARA Plasma BWTS shown slight chronic toxicity effect on the P. olivaceus ($7d-LC_{50}{\Rightarrow}100.00%$ treated discharge water, $7d-LC_{25}{\Rightarrow}85.15%$ treated discharge water). Bromobenzene, chlorobenzene and 4-chlorotoluene in 34 psu treated discharge water from ARA Plasma BWTS were higher than in the background original content of seawater. The PECs (predictive environmental concentrations) of bromobenzene, chlorobenzene and 4-chlorotoluene calculated by MAMPEC (marine antifoulant model to predict environmental concentrations) program (ver. 3.0) were 3.34E-03, 2.10E-03 and 1.73E-03 ${\mu}g\;L^{-1}$, respectively and PNECs (predicted no effect concentrations) of them were 1.6, 0.5 and 1.9 ${\mu}g\;L^{-1}$. The PEC/PNEC ratio of bromobenzene, chlorobenzene and 4-chlorotoluene did not exceed one and 3 substances did not consider as persistence, bioaccumulative and toxic. Therefore, it was suggested that treated discharge water from ARA Plasma BWTS did not pose unacceptable effect on marine ecosystem.

Lifetime test of batteries for BLE modules for site identification of vessel's crews and passengers (SIVCP) (SIVCP용 BLE 모듈의 배터리 수명시험)

  • Kwon, Hyuk-joo;Kim, Min-Gwon;Kim, Yoon-Sik;Lee, Sung-Geun
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.39 no.7
    • /
    • pp.754-759
    • /
    • 2015
  • Nowadays, short distance communication systems with low power energy (LPE) are developed for identification and monitoring of site identification of vessel crews and passengers (SIVCP). LPE communication modules, such as Bluetooth low energy (BLE) and Zigbee, are used for short distance communications with LPE. These modules enable 1:N communications and their popularity is growing since the modules can be mounted on movable objects, such as mobile devices and human body. When these modules are used, the important factor that affects their operation time and design are the capacity and size of battery. Therefore, they must be made as small as possible, and the battery should be selected to be slightly smaller than the module. In this study, we calculate the theoretical life of batteries used in SIVCP BLE modules using data sheet and discharge characteristic graph under the condition of a 1/250 transmission-ratio (TR). We thus calculate experimental life by measuring transmission current for the same TR, and low speed mode current for a 1/5000 TR and measure long-term experimental life using 1/25 TR for days. Through these experiments, we verify experimental methods for the prediction and extension of battery life that would enable us to select appropriate sizes of batteries based on vessel usage and passenger types. The selections of the module TR and battery size are important factors affecting the cost reduction of module design, the battery maintenance, and passenger convenience.

A Study of the characteristics of NOx measurement and analysis methods of the SCR system for ships (선박용 SCR 시스템 NOx 측정 및 분석 방식의 특성 연구)

  • Kim, Sung-Yoon;Lee, Young-Ho;Kim, Min;Park, Sam-Sik
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.39 no.4
    • /
    • pp.387-392
    • /
    • 2015
  • A method for measuring and analyzing the $NO_x$ in ships is described in $NO_x$ Technical Code 2008. The analysis device, as required by the Code, has been to use a Chemi-luminescence detection method or Heated Chemi-luminescence detection. on the other hand, selective catalytic reduction using $NH_3$ as a reducing agent has an interference effect on the analyzer, and causes measurement error. In this study, the Chemi-luminescence detection method was examined according to how it affects the concentration of $O_2$, CO, $SO_2$, $NH_3$. Fourier transform infrared spectrometry analysis equipment and measurement methods were compared. In order to confirm the effect of the physical interference of the measuring device, it was confirmed by decomposing a measuring device. Consequently, white precipitate and moisture were generated inside the chemiluminescence detection system and I found that affecting interference. The influence of interference highlights the need to consider the minimized $NO_x$ measurement method.

Distribution of Antifouling Agent Using Headspace Solid Phase Microextraction(HS-SPME) Method in Southwestern Coast of Korea (HS-SPME법을 이용한 한국 서남해 연안 해역에서의 방오제 분포 특성)

  • Han, Sang-Kuk
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.18 no.2
    • /
    • pp.85-93
    • /
    • 2012
  • We study on the distribution characteristics of antifouling agents such as Sea-nine 211, Irgarol 1051, Diuron using HS-SPME method in southwestern coast of Korea. Short half-life of Sea-nine 211 was distributed in very low concentrations and/or below detection limits in all of the sampling points, both water and sediments samples. Irgarol 1051 was detected to have the highest concentration respectively $6.98{\mu}g/L$, 28.50 ng/g-dry wt in the seawater and sediments, and regional distribution characteristics did not appeared. Strong bioaccumulation and long half-life of Diuron was distributed higher concentration than in all sampling point and was analyzed to have the highest concentration(3882.22 ng/g-dry wt) Mo7(Mokpo)'s sediment. Irgarol 1051 and Diuron distributed in the shipbuilding industry and ship marina are located just at the point to found in high concentrations. In addition, the distribution of the antifouling agent materials were lower in concentration than in inner bay to outter bay in sediments. Antifouling agent materials from these results were contaminated high potential from port and shipbuilding industry located in inner bay.

Development of Bioelectric Signal Sensor System using Band Type ECG (밴드형 심전도 생체신호 전극시스템의 구현)

  • Kang Sung-Chul;Kim Gi-Ryon;Kim Kwang-Nyeon;Jung Dong-Keun;Kim Min-Sung;Jeong Do-Wun;Jeon Gye-Rok
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2006.05a
    • /
    • pp.1023-1026
    • /
    • 2006
  • There are some cases in trouble with monitoring emergency patient by existing electrode sensor in measuring instrument in home and hospital etc. And there are problem to measure because of coming down electrode in emergency car or vessel of shaking and fat, humidity of patient. In this study, it has designed band-type for patient to put on the breast easily and go around anywhere freely putting band electrode on his body. Gold has used as electrode material in this electrocardiogram because of its excellent electronic resistance peculiarity and no trouble with skin. And it is able to monitor multi-body-signal by additional design of periphery temperature. There are good results of body signal transmission in the breast or the rib, and get a little body signal in abdomen. We get a result it is better case of gold than usual electrode on signal detection, and know usual electrode was disposable, but we have more correct result from gold electrode sensor, being semi-permanent ana. great contact ability even if movement.

  • PDF

A Study on the Low Sidelobe Doppler Filter Bank Design Algorithm for Coherent Radar Equipment in Complex Air-Defense System (복합 방공망 구축물에서의 Coherent 레이다 설비의 저부엽 도플러 필터 뱅크 설계 알고리즘에 관한 연구)

  • 허경무;김태형
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.10 no.2
    • /
    • pp.63-70
    • /
    • 1996
  • In this paper, we propose the low sldelobe digital doppler filter bank design algorithm which is practically applicable to coherent radar equipment in complex air-defense system. Using the proposed algorithm, we can obtain a digital doppler filter bank of lower peak sidelobe level and higher clutter suppression capability. In this method, it is possible to achieve higher target-detectability without loss of Target SNR. The proposed algorithms are verified by simulations and experiments.

  • PDF