• Title/Summary/Keyword: 생체물질

Search Result 999, Processing Time 0.041 seconds

Dependence of Ultrasonic Nonlinear Parameter B/A on Fat (지방질에 대한 초음파 비선형 파라메타 B/A의 의존성)

  • 김정구;배종림
    • The Journal of the Acoustical Society of Korea
    • /
    • v.19 no.4
    • /
    • pp.101-106
    • /
    • 2000
  • This study deals with the relationship between the magnitude of ultrasonic nonlinear parameter B/A, sound speed of amount of fat present in biological media for measuring B/A system using a wide band ultrasonic transducer. To represent this case, mixtures of egg white and egg yolk were studied. Even though the differences in density and sound speed of the two egg components were within 1% of each other, B/A were increases parabolically as a function of the fat density, which is not in agreement with the Yoshizumi et al's suggestion. In skim milk that does not contain fat, both the B/A and the sound speed increase with the solubility. It is proposed that protein could affect these values.

  • PDF

The study on Biomaterial Properties using the Optical Coefficient (광학계수를 이용한 생체물질의 특성에 관한 연구 (암조기진단을 위한 전단장치의 개발을 위한 기초연구))

  • 임현수;김부길;두재균
    • Progress in Medical Physics
    • /
    • v.9 no.2
    • /
    • pp.115-121
    • /
    • 1998
  • In this paper, basic study of diagnostic device development for early detection of cancer, we present the optical property measurements of 12 histologically classified biological tissue and blood specimens in order to determine whether significant optical contrast exists for detection of disease(cancer). In vitro, optical properties of each 630nm, 660nm, 780n, 880nm and 940nm shows consistent changes in effective absorbtion coefficients, ${\mu}$$\_$${\alpha}$/ with tissue classification of pig an chicken and human blood according to the 27.3%, 35.4%, 45.6% and 59.1% of HCT. We found differences in optical properties at each of specific wavelengths and histologically classified biological tissue.

  • PDF

A Study on Tissue Reflectance Spectrometry (생체조직의 반사 분광법에 관한 연구)

  • 임현수;김부길
    • Progress in Medical Physics
    • /
    • v.7 no.1
    • /
    • pp.25-35
    • /
    • 1996
  • Optical measurements of turbid biological tissue have provided a means to study tissue metabolism, tissue blood perfusion and blood oxygenation non-invasively. We used the red light of 660nm and infrared of 880nm to measure the blood fractional volume and oxygen saturation of biological tissue. In vivo reflectance data were obtained the physiological change from the deep tissue in human subject. The data evaluation was assessed by examining the slopes of the plotter index for the changes in oxygen saturation and blood fraction volume. The index is the natural logarithm of the ratio of reflected light intensity from measured medium to reference intensity at each wavelength. According to the experimental results, oxygen index changes significantly in the muscle of calf during exercise.

  • PDF

Study on Bio-compatible Packaging Technology for Non-enzymatic Glucose Micro-sensor Applications (마이크로 사이즈의 무효소 혈당센서 응용을 위한 생체적합한 패키징 기술에 관한 연구)

  • Park, Dae-J.;Lee, Yi-J.;Park, Jae-Y.
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.280-281
    • /
    • 2007
  • 본 논문에서는 생체 내에 삽입하거나 연속적으로 혈당을 모니터링하기 위하여 제작된 무효소 혈당세서의 바이오 패키징 및 특성 최적화에 관하여 고찰하였다. 3전극을 갖는 동일한 센서구조에서 sensitivity를 최대화하기 위해 평면형 백금전극을 사용한 센서, 메조포러스 구조가 작동전극에 형성된 센서, 메조포러스 구조가 작동전극과 보조전극에 형성된 무효소 혈당센서를 설계, 제작하고 비교하였다. 각각의 센서는 0.009${\mu}A$ $mM^{-1}cm^{-2}$, 5.46${\mu}A$ $mM^{-1}cm^{-2}$, 7.75${\mu}A$ $mM^{-1}cm^{-2}$의 sensitivity를 가졌다. 또한 생체 이식되었을 때 혈액 속에서 글루코스응답을 얻는 데에 있어 방해종인 Ascrobic Acid와 Acetaminophen의 반응을 최소화하고, 혈액 내의 단백질들이 전극에 엉겨 붙는 것을 막기 위해 생체 적합한 물질인 Nafion 을 패키징 멤브레인으로 적용하여 센서를 제작하였다. 이 센서는 0.36${\mu}A$ $mM^{-1}cm^{-2}$의 sensitivity를 가졌다.

  • PDF

최신특허 동향 바이오칩

  • 이한영
    • BT NEWS
    • /
    • v.11 no.2
    • /
    • pp.35-40
    • /
    • 2004
  • ‘바이오칩(biochip)’ 이란 컴퓨터 칩(computer chip)에서 유래되어 바이오(bio)와 관련된 어떤 집적회로의 요소와 관련된 용어로 지칭되어 왔으나, 최근 몇년 동안 기술개발이 구체으로 이루어 지면서, DNA를 포함한 생체분자(biomolecule)에 대하여 생화학적 분석에 사용되는 프로브(probe)를 정렬(array)시킨 물질 및 장치라고 정의되고있다.(중략)

  • PDF

Surface Modification of Functional Materials by a Bio-Inspired Poly(norepinephrine) Coating

  • Gang, Seong-Min
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2012.11a
    • /
    • pp.65-65
    • /
    • 2012
  • 카테콜아민의 일종인 노레피네프린을 이용하면 다양한 물질의 표면을 효과적으로 개질시킬 수 있음이 최근 보고되었다. 단순한 표면 개질뿐만 아니라 OH- 작용기의 도입이 가능하다는 장점을 갖는 노레피네프린 코팅법은 산화그래핀 혹은 흑연과 같은 비활성 표면에까지 성공적으로 적용되었으며, 그 결과 생체 적합성을 갖는 기능성 표면이 개발되었다.

  • PDF

산업보건편람 - 기업.작업별 산업보건편람

  • Korea Industrial Health Association
    • 월간산업보건
    • /
    • s.61
    • /
    • pp.29-33
    • /
    • 1993
  • 이 편람은 주요한 17가지 공정, 작업의 개요와 산업보건측에서 본 생체영향, 노동위생대책에 대하여 정의한 것이다. 특히 공장, 작업내용 등에 있어서는 직접관계자가 아니더라도 대략의 그 공정이나 유해성이 있는 물질 작업방법에 대하여 이해해 두도록 하자.

  • PDF