Comparison of Shade Changes According to Dry/Wet Condition of Tooth using Intra-Oral Colorimeter (건조정도에 따른 자연치아의 색조비교)

  • Choi, Mee-Ra
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • 제26권3호
    • /
    • pp.265-271
    • /
    • 2010
  • One of the most important aspect of esthetic dentistry is shade selection. Alterations to perception of color can occur as a result of numerous factors, including light source, tooth surface texture, observer's ability, surrounding colors, the angle of observation, light and dark adaptation and others. During the clinical procedures, tooth might be in dry or semi-dry condition. The purpose of this study was to compare the shade changes in wet and dry conditions of natural tooth. Groups of measurement are an initial wet condition as control, dry in 10seconds, 1 minute, 5minutes and 30seconds air dry. Using Shadeeye, color difference(${\Delta}E$) between measurements were analyzed and there were significant differences between groups. But most of the differneces were <3.7 ${\Delta}E$ unit. Such differences are below the threshold for perceivable color mismathces in intraoral condition. Shade selection with an intraoral colorimeter could be changes in dry and wet condition but there might be no significant differences in visual color mathing.

Shade Comparative Analysis of Natural tooth Measured by Visual and Two Colorimeters(ShadeEye®,Shadepilot®) (2종 측색기와 시각을 이용한 자연치아의 색조 비교 분석)

  • An, Jin-Hee;Choi, Mee-Ra;Shim, Hye-Won
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • 제29권1호
    • /
    • pp.81-93
    • /
    • 2013
  • The objectives were to evaluate the accuracy of shade selection by human visual system(VS) and 2 different colorimeters ($ShadeEye^{(R)}$(SE) and Shadepilot (SP)). Maxillary anterior teeth of 30 volunteers which had no caries or restorations were included in the study. Firstly, the accordance in shade selection by 3 dentists and 2 colorimeters was investigated. Secondly, the color of the teeth were measured by 1 observer's naked eye and 2 colorimeters under different illumination conditions (Sunny versus cloudy day). Additionally testing of inter-observer variability selected colors by 2 novice and 2 experienced dentists were compared. For comparing visual and 2 different colorimeters, SP(60%) showed significantly highest rate of accordance than the visual (23.3%) or SE (16.7%) and lowest mean ${\Delta}E$ ($2.62{\pm}0.74$ versus $3.83{\pm}1.38$;SE or $4.04{\pm}1.61$;VS)(p<0.001). If accuracy of shade selection were measured using VS, the mean ${\Delta}E$ value of cloudy day was higher than that of sunny day ($4.35{\pm}1.70$ versus $3.53{\pm}1.31$; p<0.001). There were no significant difference of the mean ${\Delta}E$ value between sunny and cloudy day in both SE and SP. Inter- observer repeatability was higher in 2 experienced group (73.3%) than novice group (36.7%). The mean ${\Delta}E$ of experienced group was lower than that of novice group ($3.60{\pm}1.47$ versus $4.70{\pm}1.67$; p<0.001). Colorimeters (SE or SP) is more accurate and more reproducible compared with human shade assessment. Using visual system may be limited by cloudy and inexperience of tester, then more experience and using colorimeters may be helpful of raising the accurate repeatability of shade selection.

Shade comparative analysis of natural tooth measured by visual and spectrophotometric methods (육안과 분광 측정기를 이용한 자연 치아의 색조비교분석)

  • Kim, Bum-Suk;Shin, Soo-Yeon;Lee, Jong-Hyuk
    • The Journal of Korean Academy of Prosthodontics
    • /
    • 제46권5호
    • /
    • pp.443-454
    • /
    • 2008
  • Statement of problem: A clinically successful color match is one of the important factor to get an esthetic dental restoration. Dental shade guides are commonly used to evaluate tooth color in restorative procedure. But numerous reports have indicated that common shade guides do not provide sufficient spectral coverage of the natural tooth colors. To address issues associated with the shade guide, distinct avenues have been pursued objective spectrophotometric / colorimetric assessment. Purpose: This study compared the accuracy of tooth color selection of spectrophotometer with that of human visual determination. Three main factors were investigated, namely, the effect of light, the individual variation and the experience of the observer. Material and methods: At the first experiment, on ten patients, one operator independently selected the best matching shade to the unrestored maxillary central incisor, using a Vita Classical Shade Guide in the morning, at noon and in the afternoon. The same teeth were measured by means of a reflectance spectrophotometer. At the second experiment, on ten patients, ten operators (5 experts, 5 novices) selected and measured by the same method above at noon. At the third experiment, the results of the second experiment were divided into two groups, expert and novice, and analyzed. Results: 1. There was significant difference between visual and spectrophotometric assessment (mean ${\Delta}E$ values) in experiment 1, 2, 3 (P < .05). 2. There was no significant difference between experts and novices group, when comparing with each visual and spectrophotometric assessment (mean ${\Delta}E$ values). Conclusion: Spectrophotometer could be used to analyze the shade of natural tooth objectively. Thereby, this method offers the potential tominimize considerably the need for corrections or even remakesafter intraoral try-in of restoration. Furthermore, to achieve its advantage, both the shade-matching environment and communication between dentist and technician should be optimized with use of visual and instrumental shade-matching systems.

ShadeScan system의 반복 재현성에 관한 연구

  • Jo, Cheol-Hui;Lee, Seok-Jin;Seo, Jong-Cheol;Lee, Jong-Yeop
    • Journal of the Korean Academy of Esthetic Dentistry
    • /
    • 제13권2호
    • /
    • pp.29-35
    • /
    • 2004
  • 최근 심미적인 보철 치료에 대한 사람들의 관심이 높아짐에 따라 자연치와 더욱 조화롭게 보철 치료를 하는 것이 요구되고 있다. 이는 구조적인 심미성과 함께 자연스러운 색조 재현을 통하여 이루어지는데, 자연치의 색조는 매우 다양하고 부위별로 달라질 수 있기 때문에 단순히 shade guide상의 비교만으로는 정확한 색조를 얻기가 어렵다. 이러한 색조 선택의 부정확성 때문에 객관적으로 색조를 분석하는 많은 기계적 장치들이 고안되었고, 최근에 ShadeScan system(CYNOVAD, Canada), Vita Easyshade system(Vident, Canada) 등 디지털로 색조를 평가하는 시스템이 각광을 받고 있다. ShadeScan system은 한 번의 클릭으로 치아 이미지를 채득할 수 있고, 바로 컴퓨터를 통해서 이를 분석하여 원하는 shade map, translucency map 등을 얻을 수 있다. 또한 세 방향에서 조사되는 빛은 자체 calibration을 거쳤기 때문에 주변 광원이나 환경의 영향 없이 객관적으로 치아의 이미지를 채득할 수 있다고 한다. 사실 그 동안 이미지 채득이 객관적이라고 주장하는 많은 system이 있었지만 임상의들은 그 신뢰성에대해 의구심을 보였던 것이 사실이다. 이에 본고에서는 ShadeScan system이 반복 촬영 시 같은 색조재현을 할 수 있는지 실험하여 그 객관성에 대해 살펴보았다.

  • PDF

A Spectrophotometric Study on Color Differences between Various Light-Cured Composite Resins and Shade Guides (광중합형 복합레진과 shade guide의 색차에 관한 연구)

  • Lim, Kyung-Min;Lee, Min-Ho;Song, Kwang-Yeob
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • 제25권1호
    • /
    • pp.13-22
    • /
    • 2009
  • The composite resin, due to its esthetic quality, is considered the material of choice for restoration of anterior teeth. To get a satisfactory result in the composite resin restorations, it is necessary to choose right shade. At present, most of the commercial composite resins are based on the Vita Lumin shade guides or shade guides that are provided by their company, but color differences among them might be expected even using the same shade in various materials. This study is to measure color differences between various light-cured composite resins and shade guides and to provide the clinicians with information which may aid in improved color match of esthetic restoration. Four kinds of light-cured composite resins (Gradia Direct (GD), Z250 (Z250), Clearfil AP-X (AP-X), Esthet X (E X)) and shade guides with A2 and A3 shade were used. Three specimens of each material and one specimen of each shade guide were made. Each composite resin was filled into the Teflon mold (1.35 mm depth, 8 mm diameter), followed by compression, polymerization and polishing with wet sandpaper. Shade guides were grinded with polishing stones and rubber points to a thickness of approximately 1.35 mm. Color characteristics were performed with a spectrophotometer(color i5, GretagMacbeth, USA). A computer-controlled spectrophotometer was used to determine CIELAB coordinates ($L^*$, $a^*$, $b^*$) of each specimen and shade guide. The CIELAB measurements made it possible to evaluate the amount of the color difference values (${\Delta}E^*ab$) between composite resins and shade guides. CIE standard D65 was used as the light source. The results were as follows : 1. Among the $L^*$, $a^*$, $b^*$ values of most of 4 kinds of composite resin specimens which are produced by same shade, there were significant differences(p<0.05). 2. Among all 4 kinds of composite resin specimens which are produced by same shade, there were color differences that is perceptible to human eye(${\Delta}E^*>3.3$). 3. Between most of composite resin specimens investigated and their corresponding shade guides, there were color differences that is perceptible to human eye(${\Delta}E^*>3.3$). 4. In the clinical environment, it is recommended that custom shade guides be made from resin material itself for better color matching. Shade guides supplied by manufacturers or Vita Lumin shade guide may not provide clinicians a accurate standard in matching color of composite resins, and there are perceptible color differences in most of products. Therefore, it is recommended that custom shade guides be made from resin material itself and used for better color matching.

Color cast detection based on color by correlation and color constancy algorithm using kernel density estimation (색 상관 관계 기반의 색조 검출 및 핵밀도 추정을 이용한 색 항상성 알고리즘)

  • Jung, Jun-Woo;Kim, Gyeong-Hwan
    • Journal of Korea Multimedia Society
    • /
    • 제13권4호
    • /
    • pp.535-546
    • /
    • 2010
  • Digital images have undesired color casts due to various illumination conditions and intrinsic characteristics of cameras. Since the color casts in the images deteriorate performance of color representations, color correction is required for further analysis of images. In this paper, an algorithm for detection and removal of color casts is presented. The proposed algorithm consists of four steps: retrieving similar image using color by correlation, extraction of near neutral color regions, kernel density estimation, and removal of color casts. Ambiguities in near neutral color regions are excluded based on kernel density estimation by the color by correlation algorithm. The method determines whether there are color casts by chromaticity distributions in near neutral color regions, and removes color casts for color constancy. Experimental results suggest that the proposed method outperforms the gray world algorithm and the color by correlation algorithm.

Evaluation of color matching ability according to the color temperature and the experience of practitioner (색 온도 및 술자의 숙련도에 따른 비색 능력 평가 원저)

  • Kim, Ji-Hyun;Kim, Sun-Jai;Lee, Keun-Woo;Shim, June-Sung;Yoon, Joonho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • 제50권4호
    • /
    • pp.299-304
    • /
    • 2012
  • Purpose: The aim of this study is to investigate the effect of different experience level and different light source on shade selection ability comparing prosthodontist group and dental student group under 4,000 K and 5,500 K light. Materials and methods: After color difference of Vitapan 3D-master shade guides was measured, 3 sets of 5 shade tabs were selected with similar value but have different chroma (set a, b, c). Also 3 sets of 5 shade tabs were selected with similar chroma but have different values (set d, e, f). Under 4,000 K and 5,500 K light sources, ten prosthodontists and ten dental students were allowed to match in one set of 5 tabs the same shade tab with the tab which was originally selected in the other set of 5 tabs. Color differences of original tab and matched tab were measured by spectrophotometer and the shade selection ability was evaluated with those data. Evaluation of color difference value was performed in regard to different light conditions and different level of experience, followed by t-test with 95% confidence interval. Results: Color difference values under 4,000 K and 5,500 K light source were $1.62{\pm}2.0$, and $1.33{\pm}1.7$ respectively. In addition, color difference values of prosthodontist group and dental student group were $1.34{\pm}1.7$, and $1.61{\pm}2.0$ respectively. Difference of shade selection ability was not found under either different light sources (P=.398), or different experience level (P=.221). Conclusion: Level of experience did not affect on the shade selection ability when prosthodontists and dental students matched the shades with the same shade tab under the same light source.

Analysis of Sensibility for Color Transformation using Apparel Fabric Sound (직물 소리의 색 변환을 위한 감성분석)

  • 이명은;최순남;조길수
    • Proceedings of the Korean Society for Emotion and Sensibility Conference
    • /
    • 한국감성과학회 2003년도 추계학술대회 논문집
    • /
    • pp.1341-1345
    • /
    • 2003
  • 직물의 소리에 의해 유발되는 감성을 토대로 직물의 소리를 색채와 매치시키는 실험을 실시하여 직물의 소리를 색으로 변환해 봄으로써 시각과 생각에 의한 복합감성을 활용한 직물 디자인을 제안해 보고자 하였다. 의류소재 30개의 소리를 녹음하여 군집분석한 후 각 군집별로 섬유의 종류를 고려하여 총 6개의 소리를 선택하여 주관적 감성평가와 색 변환실험에 사용하였다. 직물의 소리는 섬유의 조성에 관계없이 주로 Blue, Purple Blue 그리고 무채색으로 표현되었다. 그런, wool은 Gr(grayish), silk는 Dk(dark), polyester는 Dl(dull), nylon은 Dk(dark)등의 차분하고, 안정되고, 점잖은 느낌의 색조로, cotton과 flax는 P(pale)와 Vp(very pale) 같은 부드럽고 가벼운 느낌의 색조로 표현되었다. 따라서 직물의 소리 감성을 설명하는 요소는 색상보다는 색조에 있음을 알 수 있었다.

  • PDF

Evaluation of Color Change according to Process Step of Fused Porcelain to SLM Method (치과용 레이저 선택가공 금속체의 도재 소성단계에 따른 색조변화 관찰)

  • Kim, Chi-Young;Chung, In-Sung
    • The Journal of the Korea Contents Association
    • /
    • 제10권12호
    • /
    • pp.236-242
    • /
    • 2010
  • The porcelain fused metal was made through the progressive fused process of porcelain on substructure of metal material. The substructure was made using novel SLM method. The objective of this study was to observe the color change of porcelain using spectrophotometer equipment according to porcelain fused step and production methods after conducting the process of casting and SLM method of the substructure. The color change by step was indicated that fused opaque porcelain groups(CN1, CC1, CT1, SC1, ST1) had color difference(${\Delta}E$=30) by comparison with fused body porcelain groups(CN2, CC2, CT2, SC2, ST2) and fused glazing porcelain groups(CN3, CC3, CT3, SC3, ST3) (p<0.05). and there was no color difference between the substrates(CN, CC, CT) made by the casting method and the substrates(SC, ST) made by the SLM method. so, the color change was expressed by fused change of porcelain, and this study showed that the color of porcelain fused metal made by the SLM method can be applied clinical trials.

A Study on Color Differences Between Composite Resins and Shade Guides (복합레진과 shade guide의 색차에 관한 연구)

  • Kim, Hee-Sun;Um, Chung-Moon;Kahng, Myong-Whai
    • Restorative Dentistry and Endodontics
    • /
    • 제21권1호
    • /
    • pp.107-120
    • /
    • 1996
  • 복합레진은 조작이 용이하고 강도가 우수하며 중합시간이 짧고 법랑질과 상아질에 접착이 가능하며 연마성이 뛰어나고 자연스러운 색상을 나타내므로 심미적 수복에 가장 일반적으로 선택되는 재료의 하나이다. 대부분의 복합레진 kit에는 shade guide가 포함되어 있어 이를 기준으로 중합된 후의 복합레진 색조를 예상하여 선택하게 된다. 그러나 이러한 shade guide들은 대개 복합레진이 아닌 plastic으로 제조된 것으로 중합된 복합레진의 실제 색조와는 차이가 생기게 되며 결국 shade guide 자체의 문제점으로 인해 이상적인 색조선택이 어려워진다. 이에 본 연구에서는 국내에 시판되고 있는 5종의 복합레진 제품을 선정하여 분광 광도계를 이용해서 shade guide와 중합된 복합레진 사이의 색조차이를 측정, 비교 연구하였다. 직경 16mm. 두께 1.6mm의 plastic mold에 5종의 광중합형 복합레진(Z100, Prisma TPH, Tetric, Silux Plus, Herculite XR)을 충전하고 응축기에 넣어 압축한 후 제조사의 지시에 따라 광중합기로 중합시킨 후 mold에서 시편을 제거하여 보관했다가 젖은 sandpaper 상에서 순차적으로 연마하였다. shade guide는 step부분을 갈아내어 복합레진 시편과 동일한 두께로 만든후 연마하였다. 분광광도계에 shade guide를 넣고 CIE illuminant D65 하에서 spectral reflectance를 측정하고 해당 색조의 복합레진 시편도 통일한 방법으로 측정하고 $L^*$, $a^*$, $b^*$값과 ${\Delta}E^*$값을 얻은후 분석하여 다음과 같은 결과를 얻었다. 1. Z100의 D3, A3, B2 shade와 Prisma TPH의 B2 shade를 제외한 모든 시편에서 shade guide와 복합레진간에 육안으로 인지할 수 있는 색차(${\Delta}E^*$ > 1.0)가 관찰되었다. 2. 평균적으로 Z100이 가장 적은 색차를 나타내었고 Prisma TPH, Tetric, Silux Plus, Herculite XR 순으로 색차가 증가하였다. 3. Prisma TPH의 A2 shade. Tetric의 W shade. Silux Plus의 YB, U shade, Herculite XR의 L, LY shade는 ${\Delta}E^*$값이 3.3 이상으로 나타났다. 4. Z100, Prisma TPH, Tetric, Silux Plus에서는 복합레진보다 shade guide가 더 높은 $L^*$값을 보이는 경향이 나타났으며, Herculite XR에서만 복합레진이 더 높은 $L^*$값을 나타냈다. 5. 모든 시편에서 $b^*$ 값은 (+)로 관찰되었고, Z100, Prisma TPH, Tetric, Silux Plus의 shade guide는 복합레진에 비해 높은 $b^*$값을 보였다. 6. 모든 시편에서 $a^*$값은 (-)로 관찰되었고. Herculite XR 및 Silux Plus에서는 복합레진이 shade guide 에 비 해 낮은 $a^*$값을 나타냈다.

  • PDF