• Title/Summary/Keyword: 상재도

Search Result 256, Processing Time 0.027 seconds

The Earth Pressure on the Effect of Surcharge Load at the Narrowly Backfilled Soil (좁은 공간 되메움 지반에서의 상재하 영향에 의한 토압)

  • 문창열;이종규
    • Geotechnical Engineering
    • /
    • v.13 no.6
    • /
    • pp.165-180
    • /
    • 1997
  • The structure such as underground external walls of buildings, conduit and box culvert supports the surcharge loads (point, strip and line loads) . The vertical and horizontal stresses in a soil mass depend on the backfill width and wall friction, etc. The investigations described in this paper is designed to identify the magnitude and the distributions of the lateral and vertical pressure which is occurred by the narrowly backfilled soil in an open cut by the surcharge loads. For these purposes, model tests were performed for various width of backfill in a model test box by considering the wall friction using carbon rods. The results of test were compared with the theories of Weissenbach and VS Army Code and also with the results of the numerical analysis using finite difference method which introduces Mohr-Coulomb failure hypothesis.

  • PDF

Horizontal Active Thrusts and Design of GRS-RW System for Distanced Surcharge (상재하중 이격거리를 고려한 GRS-RW 공법의 토압해석 및 설계)

  • 방윤경
    • Journal of the Korean Geotechnical Society
    • /
    • v.15 no.1
    • /
    • pp.15-29
    • /
    • 1999
  • This study presents an analytical method of estimating the developed horizontal active thrusts against GRS-RW( Geosynthetic Reinforced Soil Retaining Wall) system adapted to the case of distanced surcharge. In addition, the design charts that could be used for preliminary design of GRS-RW system are presented. The proposed method of analysis uses two body translation mechanism as well as force polygon concept. taking into account the effect of facing's rigidity. Besides. the effect of tension cracks in c-\Phi$ soils, seismic effects and horizontal distance from the back face of wall to uniformly distributed surcharge loadings are also included. The results of horizontal active thrusts obtained from the developed method of analysis are compared with those from Jarquio's modified Boussinesq equation.

  • PDF

Effects of Overburden Stress on Stability in Unsaturated Weathered Soil Slopes (불포화 풍화계열 사면의 안정성에 미치는 상재응력의 영향)

  • Park, Seong-Wan;Park, Jai-Young
    • Journal of the Korean Geotechnical Society
    • /
    • v.25 no.10
    • /
    • pp.55-65
    • /
    • 2009
  • It has been well known that the infiltration of rainfall causes major surfacial slope failures in Korea. However, the hydrological and mechanical behaviors in unsaturated slopes are somewhat complex. When an analysis on unsaturated slope problems is performed, soil-water characteristics curves (SWCC) are considered as major parameters to apply. Since the weathered soil slopes are layered and stressed by overburden pressures, the response of SWCCs should account for its overburden pressure. To deal with this situation, in this study, laboratory testings were conducted to evaluate the SWCC under various overburden stress. In addition, the unsaturated shear strength was estimated using SWCC. Then the performance of unsaturated weathered soil slopes was evaluated under various conditions after applying the effect of overburden pressure on SWCCs. The results demonstrated that the effect of overburden pressure on SWCC could be substantial and the proper application to analysis is very important to enhance the prediction of slope stability.

Wall Displacement of Geosynthetic Reinforced Soil Walls with Different Surcharge Loads - Model Test (상재하중 변화에 따른 토목섬유 보강토옹벽의 벽체변위)

  • Lee, Kwang-Wu;Cho, Sam-Deok
    • Journal of the Korean Geosynthetics Society
    • /
    • v.7 no.2
    • /
    • pp.41-47
    • /
    • 2008
  • This paper describes the results of model experiments in the laboratory, which were conducted to assess the behavior characteristics of geosynthetic reinforced soil walls according to different surcharge loads and reinforcement types. The model walls were built in the box having dimension, 100 cm tall, 140 cm long, and 100cm wide. Three types of geosynthetics, geonet, geogrid A and geogrid B, are used as the reinforcements. Decomposed granite soil (SM) was used as a backfill material. Seven model walls are constructed and tested. After the construction of the model wall, the LVDTs are installed to obtain the displacements of the wall face. As the results of the model tests, the maximum horizontal displacements of the model walls occurred due to uniform surcharge pressure were measured at the 0.7H from the bottom of the wall. The more the reinforcement strength increases, the more the wall displacements decrease, and also the reduction ratio of the wall displacement decrease with increasing the surcharge pressure.

  • PDF

Model Tests on the Behavior of Geogrid Reinforced Soil Walls with Vertical Spacing of Reinforcement Layers (보강재 설치 간격에 따른 지오그리드 보강토옹벽의 변형거동에 관한 모형실험)

  • 조삼덕;안태봉;이광우;오세용
    • Journal of the Korean Geotechnical Society
    • /
    • v.20 no.5
    • /
    • pp.109-116
    • /
    • 2004
  • The model tests are conducted to assess the behavior characteristics of geogrid reinforced soil walls according to different surcharge pressures and reinforcement spacings. The models are built in the box having dimension, 100cm tall, 140cm long, and 100cm wide. The reinforcement used is geogrid(tensile strength 2.26t/m). Decomposed ganite soil(SM) is used as a backfill material. The strain gauges and LVDTs are Installed to obtain the strain in the reinforcements and the displacements of the wall face. From the results, it can be concluded that the more the reinforcement tensile strength increases, the more the wall displacements and the geogrid strains decreases. The maximum wall displacements and geogrid strains of the model walls occur due to the uniform surcharge pressure at the 0.7H from the bottom of the wall. The horizontal displacements of the wall face nonlinearly increase with the increase of surcharge pressures, and this nonlinear behavior is significantly presented for larger surcharge due to the nonlinear tensile strength-strain relationship of the reinforcements.

A Thermodynamic Study on Freezing Characteristics of Weathered Tuff Soil- Freezing Point Depression with the Variation of Overburden Pressure - (응회암 풍화토의 동결특성에 관한 열역학적 연구-상재하중과 동결점 저하를 중심으로-)

  • 서상열
    • Journal of the Korean Geotechnical Society
    • /
    • v.15 no.6
    • /
    • pp.297-306
    • /
    • 1999
  • In this research, the frost heave mechanism of the weathered tuff soil sampled from the area tying between Ulanbator and Beijing was studied. The frost heave tests were carried maintaining the constant temperature at both upper$(+5^{\circ}C)\; and\; lower(-5^{\circ}C)$ ends of the sample. Here, main emphasis is given on variation of the freezing point depression with the variation of applied overburden pressure. The expansion of ice lens and migration of the pore water towards freezing front were observed in the test. It was found that with the increase in overburden pressure there is decrease in heave rate and increase in the absolute value of a segregation-freezing temperature. Hence the equation between segregation-freezing temperature and overburden pressure could be suggested. Also the water content of the samples at the frozen side was shown to be higher than those at the unfrozen side. Similarly, the water at warmer part of the frozen tuff was found much higher than that of the cooler part.

  • PDF

Evaluation of Lateral Deformation and Vertical Stress of Geosynthetics Reinforced Walls by the Scale Model Test (축소모형실험을 통한 토목섬유 보강토옹벽의 수평변위 및 수직응력 평가)

  • Cho, Sam-Deok;Lee, Kwang-Wu;You, Seung-Kyong
    • Journal of the Korean Geosynthetics Society
    • /
    • v.16 no.4
    • /
    • pp.119-127
    • /
    • 2017
  • This paper presents a study of reinforced earth model wall reinforced by geosynthetics subjected to vertical surcharge. 7 types of reinforced earth model wall were constructed in the model box($100cm{\times}140cm{\times}100cm$) to assess the deformation and stress behavior of model walls according to different tensile strength and laying number of reinforcement and surcharge pressures. 3 types of geosynthetics that have different tensile strength were used as reinforcement. The test was carried out by changing the number of reinforcement to 5, 7, 9, and surcharge pressure to 50, 100, 150, 200, 250 kPa. The model test found that the maximum lateral displacements occurred at the 0.7 H (H : Wall height) position from the bottom of the model wall and vertical stress was low in the smaller surcharge pressure and the larger tensile strength of reinforcement.

Antimicrobial Activity of Niaouli (Melaleuca quinquenervia) Leaf Extracts against Skin Flora (피부 상재균에 대한 니아울리 잎 추출물의 항균활성)

  • Jang, Ha Na;Park, Soo Nam
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.40 no.3
    • /
    • pp.313-320
    • /
    • 2014
  • In this study, the antimicrobial activity of niaouli leaf extracts was evaluated against skin flora. The skin flora used for experiments were three gram-positive bacteria such as Bacillus subtilis (B. subtilis), Staphylococcus aureus (S. aureus), Propionibacterium acnes (P. acnes), and two gram-negative, Escherichia coli (E. coli), Pseudomonas aeruginosa( P. aeruginosa), and the yeast, Plasmodium ovale (P. ovale). The bioassay applied for determining the antimicrobial effects of niouli leaf extracts or fraction included the disc diffusion assay and broth dilution assay. Minimum inhibitory concentration (MIC) values of 50% ethanol extract on B. subtilis, S. aureus, P. acnes, E. coli and P. aeruginosa were 0.25%, 0.50%, 1.00%, 0.13% and 0.25% respectively and the MIC values of water fraction were 0.25%, 0.25%, 4,00%, 0.25% and 0.25%. P. ovale did not show antimicrobial activities. The MIC values of methyl paraben used as positive control indicated 0.25%, 0.25%, 0.25%, 0.13% and 0.50%. Also, Minimum bactericidal concentration (MBC) values of 50% ethanol extract were 2.00%, 2.00%, 1.00%, 0.50% and 2.00% individually and the MBC values of water fraction were 0.50%, 0.25%, 4.00%, 0.50% and 1.00%. The MBC values of methyl paraben indicated 1.00%, 0.500%, 0.50%, 0.50% and 1.00%. These results showed that water fraction was as good as methyl paraben except for P. acnes. The 50% ethanol extract also showed activity similar with it. Thus, it is concluded that the 50% ethanol extract/fraction of niaouli could be applicable to cosmetics as a natural preservatives effective in antimicrobial activity against skin flora.

Reinforcing Efficiency of Micro-Pile with Precast Retaining Wall (프리캐스트 옹벽 마이크로 파일의 보강 효율)

  • Moon, Changyeul
    • Journal of the Korean GEO-environmental Society
    • /
    • v.9 no.7
    • /
    • pp.61-71
    • /
    • 2008
  • This study investigates the lateral resistance of micro-pile system when surcharge load is acting on the back of retaining wall. Both laboratory experiments and numerical analysis were performed. The experimental retaining wall model was developed on the laboratory-sized foundation. While surcharge load was acting, the interval and length varied as experimental variables. From the investigation it is known that the micro-pile system can effectively control the lateral displacement which is developed on the precast retaining wall. The effectiveness became increased as the pile interval reduced and the length of pile increased. The greatest reinforcing efficiency was shown when the pile length was 0.5H and the interval was 7D.

  • PDF