• Title/Summary/Keyword: 상대 차이법

Search Result 208, Processing Time 0.024 seconds

Fine Structure of the Primary and the Secondary Tissues in a Coniferous Wood (침엽수재(針葉樹材)의 1차조직(次組織)과 2차조직(次組織)의 미세구조(微細構造))

  • Lee, Weon Yong;Kim, Nam-Hoon
    • Journal of Forest and Environmental Science
    • /
    • v.6 no.1
    • /
    • pp.1-7
    • /
    • 1989
  • The fine structures of the Primary and the secondary tissues in Pinus densiflora were examined by X-ray diffraction method. The results obtained are summarized as follows; 1. D-spacings of (200) and (004) Planes had little difference in both tissues. 2. The crystallinity index of the primary tissue as observed was 23%, while that of the secondary tissue was 35%. 3. The lateral crystallite size of both tissues had almost equal values. 4. The crystalline substances of the primary and the secondary tissues showed different patterns of orientation. The former had a random orientation, whereas the latter showed an orientation of 20 to 25'.

  • PDF

Effects of Metal Ions Mole Ratio, pH and Heat Treatment Condition on the Magnetic Properties and Formation of Co-precipitated M-type Barium Ferrite Powders (공침법으로 합성한 바륨 페라이트(BaM)의 형성과 자기적 성질에 미치는 금속이온 몰 비 및 pH와 열처리 조건의 영향)

  • Baek, In-Seung;Nam, In-Tak
    • Journal of the Korean Magnetics Society
    • /
    • v.19 no.6
    • /
    • pp.209-215
    • /
    • 2009
  • M-type barium ferrite (BaFe12O19) powders were synthesized through the co-precipitation method. Starting material composition $Fe^{3+}:\;Ba^{2+}$ mole ratio was fixed as 8 and the relative amount of $Fe^{3+}$ and $Ba^{2+}$ was controlled. Structure and magnetic properties and powder morphology were investigated using XRD, SEM, VSM. Powder showing high coercivity and small magnetization was obtained at pH8 and $Fe_{3+}:\;Ba_{2+}$ of 12 : 1.5. Small magnetization value was originated from the existence of ${\alpha}-Fe_2O_3$. Single-phase Mtype barium ferrite were obtained regardless of the heat treatment condition and the amount of $Fe_{3+}\;and\;Ba_{2+}$ at pH$\approx$10. The largest value of magnetization (55.7 emu/g) under investigation were obtained when $Fe_{3+}:\;Ba_{2+}$ of 13.6 : 1.7 and furnace cooled powder in $O_2$. Particle size of powder was in the range of 50~200 nm.

Optimization of Illite Polytype Quantification Method (일라이트 폴리타입 정량분석법의 최적화)

  • Chung, Donghoon;Song, Yungoo;Kang, Il-Mo;Park, Chang-Yoon
    • Economic and Environmental Geology
    • /
    • v.46 no.1
    • /
    • pp.1-9
    • /
    • 2013
  • We proposed the revised full-pattern-fitting method of illite polytype quantification with background correction and scale factor correction of WILDFIRE(C) simulated pattern, and R% value ((${\sum}$|simulated-measured|/simulated)/ $n{\times}100$) calculation, and then verified the reliability of this method by applying for the test sample ($2M_1$:1M$$\frac{._-}{.}$$1:1), and by comparing the result with Grathoff and Moore method (1996). We confirmed that the proposed method showed the error range of less than 3.6%, which is much lower than the previous full-pattern-fitting methods, in spite of the impurities of the test sample. In the comparison with Grathoff and Moore method for 2 tested samples, we obtained the relatively higher $2M_1$ contents using Grathoff and Moore method, whereas we obtained the reliable results with less than 10% of R% values.

형상계수법을 이용한 크라이오펌프용 냉각판의 기체분자 포획능력 해석

  • Im, Jeong-Bin;Gang, Byeong-Ha;Park, Seong-Je;In, Sang-Ryeol
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.08a
    • /
    • pp.86-86
    • /
    • 2011
  • 첨단 공정이 필요한 반도체와 LCD, PDP, LED 등의 디스플레이 및 IT 부품을 제조하는데 필요한 장비의 고성능화와 작업환경의 고청정화에 따른 초고진공펌프의 수요 확대와 앞으로 전개될 한-미 FTA에 따른 시장 확대로 인해 크라이오펌프의 국산화가 시급한 실정이다. 고성능 크라이오펌프를 만들기 위해서는 냉각판을 극저온으로 냉각하기 위한 극저온 냉동기 개발도 중요하지만 냉각판(cryoarray)에 최대한 많은 분자를 포획시키는 것 또한 최우선적으로 고려되어야 할 사항 중 하나이다. 이에 본 논문은 크라이오펌프용 냉각판의 기체분자 포획능력에 대하여 연구하였다. 냉각판의 분자포획능력의 해석은 형상계수법(view factor method)을 이용해 수행하였다. 해석에 이용한 냉각판은 현재 상용화된 모델들 중 원형 중앙판에 45$^{\circ}$ 하향 skirt가 달린 형태이며 8장의 냉각판이 일정한 간격을 두고 아래쪽으로 적층되어있고 이를 기본 모델로 하여 skirt의 형상이 다른 3장의 냉각판을 가진 네 가지 모델을 해석하였다. 해석에 이용한 냉각판의 기체분자 포획능력이 구속된 형상에서 얼마나 우수한가를 알아보기 위해 크라이오펌프의 입구 직경과 냉각판 중앙 원판의 직경비, 냉각판 사이의 거리, 그리고 skirt의 길이를 변화시켜가며 극저온 냉각판에 직접 응축되는 typeII가스와 흡착제가 도포된 부분에 의해 흡착되는 typeIII가스로 분류하여 해석을 수행하고 그 결과를 비교, 분석하였다. 크라이오펌프의 입구 직경과 냉각판 중앙 원판의 직경비가 증가함에 따라 typeII가스와 typeIII가스 모두 기체분자 포획능력이 증가하며 극저온 냉각판 사이 거리의 변화에 따른 기체분자 포획능력은 typeII가스의 경우 극저온 냉각판 사이의 거리가 증가할수록 증가한다. 하지만 typeIII가스는 모델 A, C의 경우 증가하고 모델 B, D의 경우 증가하다가 다시 약간 감소한다. skirt 길이 변화에 따른 기체분자 포획능력은 두 가스 모두 skirt 길이가 증가함에 따라 점점 급격하게 증가하고 모델 B, D는 나머지 두 모델에 비해 큰 값을 갖는다. 기체분자 포획능력을 해석한 결과를 실제 배기속도와 비교할 경우 절대적 수치로써의 비교는 어려우나 각 모델의 형상의 차이에 의한 상대적인 비교는 가능하다.

  • PDF

Determination of Plutonium in HANARO Irradiated Fuel by IDMS (동위원소희석 질량분석법에 의한 조사 후 하나로 핵연료 중 Pu 정량)

  • Jeon, Young Shin;Son, Sae Chul;Kim, Jung Suk
    • Analytical Science and Technology
    • /
    • v.16 no.3
    • /
    • pp.191-197
    • /
    • 2003
  • Two methods, IDMS (Isotope Dilution Mass Spectrometry) and controlled potential coulometry are compared by the determination of Pu for the NBL, CRM No.122, $PuO_2$. The recovery of Pu was found to be $1.002176{\pm}0.000452$ within the relative standard deviation of 0.045% (95% conf. level) although a small size of sample ($0.9{\mu}g$-Pu) was used in IDMS. The recovery using controlled potential coulometry were obtained in the range of 0.9923~0.9960. The analytical results of IDMS and controlled potential coulometry were good agreement within 0.6~1%. Base on these experiment results, The plutonium in HANARO irradiated fuel rod that separated portion of top, middle, and bottom were determined. The measured values of Pu are 1.155 mg, 2.483 mg and 1.920 mg in one gram of sample(fuel+clad), respectively.

Differential Pulse Voltammetric Determination of Co(II) Ion with a Chemically Modified Carbon Paste Electrode Containing ${\iota}$ -Sparteine (${\iota}$ -Sparteine으로 변성된 Carbon Paste 전극을 사용한 Co(II) 이온의 펄스 차이 전압-전류법 정량)

  • Eu-Duck Jeong;Mi-Sook Won;Deog-Su Park;Yoon-Bo Shim;Sung-Nak Choi
    • Journal of the Korean Chemical Society
    • /
    • v.37 no.10
    • /
    • pp.881-887
    • /
    • 1993
  • A cobalt(II) ion-selective carbon-paste electrode (CPE) was constructed with ${\iota}$-sparteine. Cobalt(II) ion in aqueous solution was chemically deposited through the complexation with ${\iota}$-sparteine onto the CPE. The surface of CPEs were characterized by cyclic voltammetry and differential pulse voltammetry in an acetate buffer solution, separately. Exposure of the CPEs to an acid solution could regenerate surface to reuse it for the deposition. In more than 5 deposition / measurement / regeneration cycles, the response was reproducible and linear up to $5.0{\times}10^{-6}$M with linear sweep voltammetry. The peaks at 0.17V / 0.27V were correspond to the redox of Co(II)-SP complex deposited on CPE. The anodic peak of which appeared after scan over the cathodic peak of 0.17 V to more negative scan. In case of using the differencial pulse voltammetry (DPV), we have obtained the linear response $2.0{\times}10^{-7}$M with relative standard deviation ${\pm}5.6%$. The detection limit was $1.0{times}10^{-7}$M for 20 minutes of the deposition. We have also investigated the interference effect of various metal ions, which are expected to form the complex with the ligand on the electrode.

  • PDF

Influences of Fractionation of Stable Isotopic Composition of Rain and Snowmelt on Isotopic Hydrograph Separation (강우와 융설의 안정동위원소 변동에 의한 동위원소 수문분리법의 계통오차계산)

  • Lee, Jeonghoon;Koh, Dong-Chan;Choo, Mi Kyung
    • Journal of the Korean earth science society
    • /
    • v.35 no.2
    • /
    • pp.97-103
    • /
    • 2014
  • An isotopic hydrograph separation technique has been able to determine the contribution of new water (event water such as rain or snowmelt) and old water (pre-event water like groundwater) to a stream hydrograph for last several decades using stable water isotopes. It is based on the assumption that the isotopic compositions of both new water and old water at a given instant in time are known and the stream water is a mixture of the two waters. In this study, we show that there is a systematic error (standard error in the new water fraction) in the isotopic hydrograph separation if the average isotopic compositions of new water were used ignoring the temporal variations of those of new water. The standard error in the new water fraction is caused by: (1) the isotopic difference between the average value and temporal variations of new water; (2) the new water fraction as runoff contributing to the stream during rainfall or spring melt; and (3) the isotopic differences between new and old water (inversely). The standard error is large, in particular, when new water dominates the stream flow, such as runoff during intense rainfall and in areas of low infiltration during spring melt. To reduce the error in the isotopic hydrograph separation, incorporation of fractionation in the isotopic composition of new water observed at a point should be considered with simultaneous sampling of new water, old water and stream water.

A simple approach to refraction statics with the Generalized Reciprocal Method and the Refraction Convolution Section (GRM과 RCS 방법을 이용한 굴절파 정적 시간차를 구하는 간단한 방법)

  • Palmer Derecke;Jones Leonie
    • Geophysics and Geophysical Exploration
    • /
    • v.8 no.1
    • /
    • pp.18-25
    • /
    • 2005
  • We derive refraction statics for seismic data recorded in a hard rock terrain, in which there are large and rapid variations in the depth of weathering. The statics corrections range from less than 10 ms to more than 70 ms, often over distances as short as 12 receiver intervals. This study is another demonstration of the importance in obtaining accurate initial refraction models of the weathering in hard rock terrains in which automatic residual statics may fail. We show that the statics values computed with a simple model of the weathering using the Generalized Reciprocal Method (GRM) and the Refraction Convolution Section (RCS) are comparable in accuracy to those computed with a more complex model of the weathering, using least-mean-squares inversion with the conjugate gradient algorithm (Taner et al., 1998). The differences in statics values between the GRM model and that of Taner et al. (1998) systematically vary from an average of 2ms to 4ms over a distance of 8.8 km. The differences between these two refraction models and the final statics model, which includes the automatic residual values, are generally less than 5 ms. The residuals for the GRM model are frequently less than those for the model of Taner et al. (1998). The RCS statics are picked approximately 10 ms later, but their relative accuracy is comparable to that of the GRM statics. The residual statics values show a general correlation with the refraction statics values, and they can be reduced in magnitude by using a lower average seismic velocity in the weathering. These results suggest that inaccurate average seismic velocities in the weathered layer may often be a source of short-wavelength statics, rather than any shortcomings with the inversion algorithms in determining averaged delay times from the traveltimes.

Spectral Analysis of Resting EEG in Brain Compartments (휴지기 뇌파의 구역별 주파수 분석)

  • Lee, Migyung
    • Sleep Medicine and Psychophysiology
    • /
    • v.27 no.2
    • /
    • pp.67-76
    • /
    • 2020
  • Objectives: Brain maturation involves brain lateralization and asymmetry to achieve efficient information processing and cognitive controls. This study elucidates normal brain maturation change during the gap between ages 6-9 and age 14-17 using resting EEG. Methods: An EEG dataset was acquired from open source MIPDB (Multimodal Resource for Studying Information Processing in the Developing Brain). Ages 6-9 (n = 24) and ages 14-17 (n = 26) were selected for analysis, and subjects with psychiatric illness or EEG with severe noise were excluded. Finally, ages 6-9 (n = 14) and ages 14-17 (n = 11) were subjected to EEG analysis using EEGlab. A 120-sec length of resting EEG when eyes were closed was secured for analysis. Brain topography was compartmentalized into nine regions, best fitted with brain anatomical structure. Results: Absolute power of the delta band and theta band in ages 6-9 was greater than that of ages 14-17 in the whole brain, and, also is relative power of delta band in frontal compartment, which is same line with previous studies. The relative power of the beta band of ages 14-17 was greater than that of ages 6-9 in the whole brain. In asymmetry evaluation, relative power of the theta band in ages 14-17 showed greater power in the left than right frontal compartment; the opposite finding was noted in the parietal compartment. For the alpha band, a strong relative power distribution in the left parietal compartment was observed in ages 14-17. Absolute and relative power of the alpha band is distributed with hemispheric left lateralization in ages 14-17. Conclusion: During the gap period between ages 6-9 and ages 14-17, brain work becomes more complicated and sophisticated, and alpha band and beta band plays important roles in brain maturation in typically developing children.

The Calculation of Energy Distributions for Clinical Electron Beams from Mono Energetic Depth dose Data (단일에너지 깊이선량률 자료에 의한 치료용 전자선의 에너지분포 계산)

  • 이정옥;정동혁
    • Progress in Medical Physics
    • /
    • v.15 no.1
    • /
    • pp.39-44
    • /
    • 2004
  • The energy distributions for clinically used electron beams from measured and calculated mono energetic depth dose values were calculated. The energy distributions having the minimum difference between the measured and reduced values of depth dose are determined by iterations based on least square method. The nominal energies of 6, 9, 12, 15 MeV clinical electron beams were examined. The Monte Carlo depth dose calculations with determined energy distributions were peformed to evaluate those distributions. In a comparison of the calculated and measured depth dose data, the standard errors are estimated within $\pm$ 3% from surface to R$_{80}$ depth and within $\pm$4% from the surface to near the range for all electron beams. This can be practically applied to determine the energy distributions for clinically used electron beams.

  • PDF