• Title/Summary/Keyword: 삽입물

Search Result 573, Processing Time 0.037 seconds

Effect on the structural integrity and fatigue damage monitoring of smart composite structures with embedded intensity based optical fiber sensors (삽입된 광강도형 광섬유센서가 지능형 복합재 구조물의 건전성에 미치는 영향 및 피로손상 감시)

  • Lee, Dong-Chun;Lee, Jung-Ju;Seo, Dae-Cheol;Huh, Jeung-Soo
    • Journal of Sensor Science and Technology
    • /
    • v.10 no.1
    • /
    • pp.42-51
    • /
    • 2001
  • In this study, the effects of embedded optical fibers on the static properties under tensile load and dynamic properties under fatigue load of composite laminates were investigated by experimental tests and finite element analysis. Based on the results, it can be concluded that the embedded optical fiber sensors do not have significant effects on the structural integrity of the smart composite structures except when the sensors are embedded perpendicular to the adjacent reinforcing fibers under fatigue loading. An intensity-based optical fiber sensor was embedded in the crossply composite laminates to monitor the fatigue damage by detecting the stiffness changes of the laminates. The result of this experiment has shown that the intensity-based optical fiber sensor has large potential to monitor the fatigue damage of composite structures by detecting the stiffness changes of the structures with simple and inexpensive instruments and without complex post-processing of measured signals. In addition, the optical fiber sensor showed good resistance to fatigue loading and wide sensing ranges of stiffness.

  • PDF

Effects of Semi-Rigid Connection and Foundation Type on Static Behavior of Plastic Greenhouse (부재 교차부와 기초 조건이 비닐하우스의 정적거동에 미치는 영향)

  • Ryu, Hee-Ryong;Cho, Myeong-Whan;Yu, In-Ho;Lee, Eung-Ho;Woo, Jong-Gyu;Lee, Jae-Young
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2011.04a
    • /
    • pp.61-62
    • /
    • 2011
  • 비닐하우스는 매우 세장한 강관부재들을 교차 결합하여 조립한 철골 구조물의 한 종류이다. 현행 설계기준으로 단동 비닐하우스의 최대 구조성능은 풍하중 40m/s, 설하중 50cm에 달한다. 그러나 설계 단계에서는 부재들의 교차결합 특성 및 부재가 직접 지반에 삽입되는 기초의 특성이 적합하게 반영되지 않는 문제점이 있다. 따라서 가력시험을 통하여 반강접 특성을 갖는 부재 교차부 및 지반삽입기초 조건이 구조물의 거동에 미치는 영향을 분석하였다. 부재 교차부가 강접 조건일 경우와 비교하여 교차부가 반강접일 경우에는 재하지점의 수평강성이 최대 54% 작게 나타났으나 주변 교차절점들에서의 에너지 흡수로 인하여 재하지점과 수평으로 3m 떨어진 지점에서는 반대로 최대 39% 큰 값을 보였다. 지반삽입기초의 경우에는 고정조건과 비교하여 재하지점의 수평강성이 최대 32% 작게 나타났으며, 지점부에서는 기초 조건의 영향으로 최대 26%의 휨강성 증가 효과를 보였다. 부재 교차부와 기초 조건이 구조물의 정적거동에 미치는 영향을 확인하였으나 최대내력과 강성 산정을 통한 구조성능 평가 방법의 개발이 필요할 것으로 판단된다.

  • PDF

The Failure of Polyethylene Lock of MUTARS Distal Femur Tumor Endoprostheses: A Case Report (원위 대퇴골 종양 금속 대치물(MUTARS$^{(R)}$)의 폴리에틸렌 잠김(LOCK)부 파손: 증례 보고)

  • Jeong, Won-Ju;Park, Il-Hyung
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.19 no.2
    • /
    • pp.74-77
    • /
    • 2013
  • The guidelines for the treatment of massive bone defects caused by bone resection due to tumors have changed from amputation to limb salvaging surgery. Limb salvaging surgery using endoprotheses is a well-established procedure. However, Aseptic loosening, infection, and mechanical defect remain significant problems. Among them, we experienced the case with a breakage of polyethylene lock of MUTARS$^{(R)}$ distal femur tumor Endoprostheses.

Limb Salvage Surgery after Removal of Infected Tumor Prosthesis with Equalization of Leg Length (감염된 종양 대치물 제거와 하지 단축 보정 후 시행한 사지 구제술 - 증례 보고 -)

  • Kwon, Young-Ho;Kim, Jae-Do;Chung, So-Hak;Cho, Yool
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.12 no.2
    • /
    • pp.141-147
    • /
    • 2006
  • In 1996, a nine-year-old girl was treated with recycling autograft after wide resection of the distal femoral osteosarcoma. The leg lengthening and revision with growing tumor prosthesis were performed due to limb leg discrepancy and epiphyseal problem. However, deep infection developed after operation, and a temporary spacer with cement and Ender nail was inserted. After infection was controlled completely, the final leg lengthening was performed with mono-external fixator for limb length discrepancy (10 cm). Lastly, Tumor prosthesis was reinserted to preserve the joint function.

  • PDF

A Biomechanical Study on a New Surgical Procedure for the Treatment of Intertrochanteric Fractures in relation to Osteoporosis of Varying Degrees (대퇴골 전자간 골절의 새로운 수술기법에 관한 생체역학적 분석)

  • 김봉주;이성재;권순용;탁계래;이권용
    • Journal of Biomedical Engineering Research
    • /
    • v.24 no.5
    • /
    • pp.401-410
    • /
    • 2003
  • This study investigates the biomechanical efficacies of various cement augmentation techniques with or without pressurization for varying degrees of osteoporotic femur. For this study, a biomechanical analysis using a finite element method (FEM) was undertaken to evaluate surgical procedures, Simulated models include the non-cemented(i.e., hip screw only, Type I), the cement-augmented(Type II), and the cemented augmented with pressurization(Type III) models. To simulate the fracture plane and other interfacial regions, 3-D contact elements were used with appropriate friction coefficients. Material properties of the cancellous bone were varied to accommodate varying degrees of osteoporosis(Singh indices, II∼V). For each model. the following items were analyzed to investigate the effect surgical procedures in relation to osteoporosis of varying degrees : (a) von Mises stress distribution within the femoral head in terms of volumetric percentages. (b) Peak von Mises stress(PVMS) within the femoral head and the surgical constructs. (c) Maximum von Mises strain(MVMS) within the femoral head, (d) micromotions at the fracture plane and at the interfacial region between surgical construct and surrounding bone. Type III showed the lowest PVMS and MVMS at the cancellous bone near the bone-construct interface regardless of bone densities. an indication of its least likelihood of construct loosening due to failure of the host bone. Particularly, its efficacy was more prominent when the bone density level was low. Micromotions at the interfacial surgical construct was lowest in Type III. followed by Type I and Type II. They were about 15-20% of other types. which suggested that pressurization was most effective in limiting the interfacial motion. Our results demonstrated the cement augmentation with hip screw could be more effective when used with pressurization technique for the treatment of intertrochanteric fractures. For patients with low bone density. its effectiveness can be more pronounced in limiting construct loosening and promoting bone union.

Preparation of Natural Chemicals Intercalated Aminoclay via One-pot Synthesis and its Antimicrobial Property (One-pot 합성을 통해 천연 화합물이 삽입된 아미노클레이 제조 및 항균성 연구)

  • Kim, Seong Yeol;Choi, Yoo-Sung
    • Applied Chemistry for Engineering
    • /
    • v.28 no.5
    • /
    • pp.495-500
    • /
    • 2017
  • In this study, we synthesized the aminoclay (AC) with magnesium ions and 3-aminopropyl triethoxysilane (APTES). At the same time, propolis intercalated aminoclay (PIAC) and coptis extract intercalated aminoclay (CIAC) were synthesized by intercalating natural chemicals between clay sheets. Clay synthesis and natural chemical intercalation were confirmed through SEM, particle size analyze, FT-IR, TGA and XRD. In particular, the characterization of intercalation of natural chemicals was determined by analyzing the interlayer distance from XRD data. The antimicrobial property of PIAC and CIAC was checked by minimum inhibitory concentration (MIC) test and increased compared with that of the pristine aminoclay (AC).

Evaluating the Impact of Attenuation Correction Difference According to the Lipiodol in PET/CT after TACE (간동맥 화학 색전술에 사용하는 Lipiodol에 의한 감쇠 오차가 PET/CT검사에서 영상에 미치는 영향 평가)

  • Cha, Eun Sun;Hong, Gun chul;Park, Hoon;Choi, Choon Ki;Seok, Jae Dong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.1
    • /
    • pp.67-70
    • /
    • 2013
  • Purpose: Surge in patients with hepatocellular carcinoma, hepatic artery chemical embolization is one of the effective interventional procedures. The PET/CT examination plays an important role in determining the presence of residual cancer cells and metastasis, and prognosis after embolization. The other hand, the hepatic artery chemical embolization of embolic material used lipiodol produced artifacts in the PET/CT examination, and these artifacts results in quantitative evaluation influence. This study, the radioactivity density and the percentage error was evaluated by the extent of the impact of lipiodol in the image of PET/CT. Materials and Methods: 1994 NEMA Phantom was acquired for 2 minutes and 30 seconds per bed after the Teflon, water and lipiodol filled, and these three inserts into the enough to mix the rest behind radioactive injection with $20{\pm}10MBq$. Phantom reconfigure with the iterative reconstruction method the number of iterations for two times by law, a subset of 20 errors. We set up region of interest at each area of the Teflon, water, lipiodol, insert artifact occurs between regions, and background and it was calculated and compared by the radioactivity density(kBq/ml) and the% Difference. Results: Radioactivity density of the each region of interest area with the teflon, water, lipiodol, insert artifact occurs between regions, background activity was $0.09{\pm}0.04$, $0.40{\pm}0.17$, $1.55{\pm}0.75$, $2.5{\pm}1.09$, $2.65{\pm}1.16 kBq/ml$ (P <0.05) and it was statistically significant results. Percentage error of lipiodol in each area was 118%, compared to the water compared with the background activity 52%, compared with a teflon was 180% of the difference. Conclusion: We found that the error due to under the influence of the attenuation correction when PET/CT scans after lipiodol injection performed, and the radioactivity density is higher than compared to other implants, lower than background. Applying the nonattenuation correction images, and after hepatic artery chemical embolization who underwent PET/CT imaging so that the test should be take the consideration to the extent of the impact of lipiodol be.

  • PDF

A Study on Digital Fingerprinting Technology for the Copyright Protection of the Image Contents Printout (이미지 콘텐츠 출력물의 저작권보호를 위한 디지털 핑거프린팅 기술에 관한 연구)

  • Seo, Yong-Seok;Kim, Won-Gyum;Lee, Seon-Hwa;Suh, Young-Ho;Hwang, Chi-Jung
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2006.11a
    • /
    • pp.242-245
    • /
    • 2006
  • This paper addresses an image fingerprinting scheme for the print-to-capture model performed by a photo printer and digital camera. When capturing an image by a digital camera, various kinds of distortions such as noise, geometrical distortions, and lens distortions are applied slightly and simultaneously. In this paper, we consider several steps to extract fingerprints from the distorted image in print-and capture scenario. To embed ID into an image as a fingerprint, multi-bits embedding is applied. We embed 64 bits ID information as a fingerprint into spatial domain of color images. In order to restore a captured image from distortions a noise reduction filter is performed and a rectilinear tiling pattern is used as a template. To make the template a multi-bits fingerprint is embedded repeatedly like a tiling pattern into the spatial domain of the image. We show that the extracting is successful from the image captured by a digital camera through the experiment.

  • PDF

Reconstruction of Distal Radius Using Ultrahigh Molecular Weight Polyethylene Liner after Excision of Giant Cell Tumor - A Case Report - (원위 요골에 발생한 거대 세포종의 일괄 절제 후 초고분자량 폴리에틸렌 삽입물을 이용한 재건술 - 증례보고 -)

  • Jeon, Dae-Geun;Song, Won-Seok;Oh, Jung-Moon
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.10 no.1
    • /
    • pp.29-33
    • /
    • 2004
  • A giant cell tumor (GCT) of the distal radius is not common. Curettage with bone cementation is considered as a treatment of choice but, in the case of recurrence, marked cortical disruption, or articular invasion, en bloc excision and reconstruction with proximal fibular bone graft is usual procedure. In reconstruction of en bloc resected distal radius which had recurred GCT after conservative operation, we used the ultrahigh molecular weight polyethylene (UHMWPE) liner with intramedullary rod and bone cement, because the contamination was extent in previous operation and recurrence after fibular bone graft was fearful. This article introduce our new surgical procedure.

  • PDF

Elasto-plastic behaviour of joint by inserting length of H-beam and structural laminated timber (H형강과 구조용집성재의 삽입길이에 따른 접합부의 탄소성 거동)

  • Kim, Soon Chul;Yang, Il Seung;Moon, Youn Joon
    • Journal of Korean Society of Steel Construction
    • /
    • v.18 no.2
    • /
    • pp.251-259
    • /
    • 2006
  • In some cases, wooden structures are used for medium-rise buildings. It is therefore necessary to develop and test a new structural system for medium-rise buildings using wooden structures. This study deals with high-performance, laminated, timber-based composite members, which consist of structural laminated timber and H-beam. Simple beam tests were performed to determine the strength, stress distributions, and failure patterns of laminated timber. The main parameters are the insertinglength (1, 1.5, and 2 times the H-beam height) and the epoxy between the top/bottom flange of the H-beam and the top/bottom flange of the laminated timber. The results of the test show that the specimen with an inserting length that is 2 times the H-beam height was characterized by fairly god strength and stiffness.