• 제목/요약/키워드: 삼첨판

Search Result 177, Processing Time 0.028 seconds

Clinical Experiences of Open Heart Surgery (개심술(開心術) 2,000례의 임상적 고찰)

  • 김하늘루;박경택;곽기오;한일용;소영환;최강주;이양행;조광현
    • Journal of Chest Surgery
    • /
    • v.31 no.12
    • /
    • pp.1183-1194
    • /
    • 1998
  • Background: From Sept. 1985 to Sept. 1997, 2,000 cases of open heart surgery(OHS) were performed in the Department of Thoracic & Cardiovascular Surgery, Pusan Paik Hospital, College of Medicine, Inje University. Material and Method: Among the total of 2,000 cases of OHS, 1532 cases were congenital heart disease(CHD) and 468 cases were acquired heart disease(AHD). The age distribution was 9 days(4.0kg) to 68 years in CHD and 11 to 66 years in AHD. In 1532 cases of CHD, there were 1403 acyanotic cases and 129 cyanotic cases. Result: The CHD cases consisted of 940 ventricular septal defects(61.4%), 324 atrial septal defects(21.1%), 112 tetralogy of Fallot(7.3%), 46 pulmonary stenosis(3%), 38 endocardial cushion defects(2.5%), 15 valsalva sinus ruptures(1%), 4 transposition of great arteries (0.3%), 4 double outlet right ventricles(0.3%), and etc. Corrective operations were applied for congenital heart disease with a result of 3.1% hospital mortality. Of 468 AHD, 381 cases were valvular heart diseases, 48 ischemic heart diseases, 12 cardiac tumors, 8 annuloaortic ectasias, 16 dissecting aortic aneurysms and etc. In the 381 valvular heart diseases, there were 226 single valve replacements(36 aortic valve replacements(AVR), 188 mitral valve replacements(MVR), and 2 tricuspid valve replacements(TVR), among these were 71 cases of double valve replacements(AVR & MVR), 54 cases of MVR with tricuspid valve annuloplasty(TVA), and 18 cases of AVR, MVR with TVA. The total implanted prosthetic valves were 466. In MVR, 123 St. Jude Medical valves, 90 Carpentier-Edwards valves, 65 CarboMedics valves, 42 Sorin valves and 16 other valves were used. In AVR, 68 St. Jude Medical valves, 36 CarboMedics valves, 14 Carpentier-Edwards valves and 9 other valves were used. Coronary Artery Bypass Surgery(CABG) were performed in 48 cases. The patterns of bypass graft were 14 patients of single vessel graft, 21 patients of two vessels graft, 10 patients of three vessels graft and 3 patients of four vessels graft. Conclusion: The hospital operation mortality rate of congenital acyanotic, cyanotic and acquired heart diseases were 2.0%, 15.5%, and 5.1% respectively. The overall mortality rate was 3.6%(72/2,000).

  • PDF

Surgical Treatment of Pulmonary Atresia with Intact Ventricular Septum -Effect of the size of tricuspid valve annulus on the surgical outcome- (영아기에 발견된 심실중격이 온전한 폐동맥 폐쇄증의 외과적 수술요법 술전 삼첨판륜 크기 가 수술 결과에 미치는 영향)

  • 이정렬;윤태진
    • Journal of Chest Surgery
    • /
    • v.29 no.10
    • /
    • pp.1081-1089
    • /
    • 1996
  • Pulmonary atresia with intact ventricular septum has continued to have a high surgical mortality and morbidity. This mAy attribute to the non-uniformity of the anomaly. We reviewed a total of 34 infants with pulmonary atresla and intact ventricular septum managed in this hospital between 1987 and 1995. Mean age and body weight were 57.2 (range, 3-208) days and 4.1 (range, B.3∼6.8) kg. The preoperative Z-value of the diameter of the tricuspid valve was less than -2 in 85.2% of patients and less than -4 in 33. 3% . It is well correlated w th right ventricular cavity size (n=27. r10.68, p< 0.05). Coronary artery-right ventricular fistulas were identified in 3 patients, and right ventricular dependency was suspected in 1 Over All hospital mortality was 23.5%(8/34), although it decreased to 16.6%(4124) in 1990s. Subsequent procedures were performed in 6 patients between 3 days and 58 months after Initial palliation : one bidirectional cavopulmonary shunt and 1 Fontan operation after systemic-pulmonary shunt, 3 transannular patch + atrial septal defect closure and 1 additional systemic-pulmonary shunt after polmonary valvectomy or valvotomy. Changes of Z-values of the diameter of tricuspid valve have been followed up in 11 patients between 1 and 66 months postoperatively. Z-values were increased In 5 out of 8 transannular right ventriculAr outflow tract enlargement group and in 1 out of 3 pulmonary valvectomy or valvotomy group. Our data suggest that tailoring a treatment to right ventricular cavity size and coronary anom lies may improve the surgical outcome. A Z-value of the tricuspid valve diameter could be used.

  • PDF

Pulmonary Valve Replacement with Tissue Valves After Pulmonary Outflow Tract Repair in Children (소아에서 폐동맥유출로 재건 후 시행한 조직판막을 이용한 폐동맥판 대치술)

  • Lee, Jeong-Ryul;Hwang, Ho-Young;Chang, Ji-Min;Lee, Cheul;Choi, Jae-Sung;Kim, Yong-Jin;Rho, Joon-Ryang;Bae, Eun-Jung
    • Journal of Chest Surgery
    • /
    • v.35 no.5
    • /
    • pp.350-355
    • /
    • 2002
  • Background: Most of pulmonary regurgitation with or without stenosis appears to be well tolerated early after the repair of pulmonary outflow tract. However, it may result in symptomatic right ventricular dilatation, dysfunction and arrhythmias over a long period of time. We studied the early outcome of pulmonary valve replacement with tissue valves for patients with the above clinical features. Material and Method: Sixteen consecutive patients who underwent pulmonary valve replacement from September 1999 to February 2002 were reviewed(9 males and 7 females). The initial diagnoses included tetralogy of Fallot(n=11), and other congenital heart anomalies with pulmonary outflow obstruction(n=5). Carpentier-Edwards PERIMOUNT Pericardial Bioprostheses and Hancock porcine valves were used. The posterior two thirds of the bioprosthetic rim was placed on the native pulmonary valve annulus and the anterior one third was covered with a bovine pericardial patch. Preoperative pulmonary regurgitation was greater than moderate degree in 13 patients. Three patients had severe pulmonary stenosis. Tricuspid regurgitation was present in 12 patients. Result: Follow-up was complete with a mean duration of 15.8 $\pm$ 8.5months. There was no operative mortality. Cardiothoracic ratio was decreased from 66.0 $\pm$ 6.5% to 57.6 $\pm$ 4.5%(n=16, p=0.001). All patients remained in NYHA class I at the most recent follow-up (n=16, p=0.016). Pulmonary regurgitation was mild or absent in all patients. Tricuspid regurgitation was less than trivial in all patients. Conclusion: In this study we demonstrated that early pulmonary valve replacement for the residual pulmonary regurgitation with or without right ventricular dysfunction was a reasonal option. This technique led to reduce the heart size, decrease pulmonary regurgitation and tricuspid regurgitation as well as to improve the patients'functional status. However, a long term outcome should be cautiously investigated.

The First 20 Cases of Cardiac Surgery Using the da $Vinci^{TM}$ Surgical System: A Single Center Experience (다빈치 수술로봇을 이용한 심장수술 20예 보고 - 단일 기관 보고 -)

  • Je, Hyoung-Gon;Lee, Yong-Jik;Jung, Sung-Ho;Jung, Jae-Seung;Kang, Pil-Je;Choo, Suk-Jung;Song, Hyun;Chung, Cheol-Hyun;Lee, Jae-Won
    • Journal of Chest Surgery
    • /
    • v.41 no.4
    • /
    • pp.423-429
    • /
    • 2008
  • Background: The interest in robotic cardiac surgery has recently grown but there has not been much clinical research reported on this. The aim of this study is to examine our initial experience, since August 2007, with robotic cardiac surgery using the da $Vince^{TM}$ surgical system and to evaluate the feasibility and safety of it. Material and Method: Between August and December 2007, a total of 20 patients underwent robotic cardiac surgery using the da Vinci surgical system. For mitral valve repair (n=11), tricuspid valve repair (n=1), and ASD repair (n=1), cannulation, antegrade cardioplegia and transthoracic aortic cross-clamping were conducted for the right femoral vessels and the right internal jugular vein. For minimally invasive direct CABG (MIDCAB) (n=7), the internal thoracic artery (ITA) was harvested with the da Vinci surgical system. Result: The mean age of the patients was 50.1 (range: $26{\sim}78$) years. Three concomitant Maze procedures and one tricuspid annuloplasty were combined with mitral valve repair. The mean cardiopulmonary bypass time was $208.0{\pm}61.3$ minutes and the aortic cross clamp time was $158.8{\pm}40.6$ minutes. No patients showed more than mild mitral regurgitation after repair and the median hospital stay was 4 days. The robotic-harvested ITA was used for either left ITA (n=6) or bilateral ITA (n=1). The mean harvest time was $43.2{\pm}12.0$ minutes. The harvested ITA showed good flow and it was anastomosed under direct vision after left anterolateral thoracotomy. The patency of all the grafts was 100% (18/18) in MIDCAB. Conclusion: Robotic cardiac surgery using the da Vinci surgical system was variously adapted to areas such as mitral and tricuspid valve repair, ASD repair and ITA harvest for MIDCAB. The early results of the robotic cardiac surgery showed its safety and feasibility. With this primary report, we anticipate that clinical applications and further studies on robotic cardiac surgery using the da Vinci surgical system will be actively conducted in Korea.

Echocardiographic Diagnosis of Pulmonary Arterial Hypertension in Chronic Lung Disease with Hypoxemia (만성 저산소성 폐질환의 폐동맥 고혈압에 대한 심초음파 검사)

  • Chang, Jung-Hyun
    • Tuberculosis and Respiratory Diseases
    • /
    • v.46 no.6
    • /
    • pp.846-855
    • /
    • 1999
  • Background : Secondary pulmonary hypertension is an important final endpoint in patients with chronic hypoxic lung disease, accompanied by deterioration of pulmonary hemodynamics. The clinical diagnosis of pulmonary hypertension and/or cor pulmonale could be difficult, and simple noninvasive evaluation of pulmonary artery pressures has been an relevant clinical challenge for many years. Doppler echocardiography might to be a more reliable method for evaluating pulmonary hemodynamics in such patients in terms of the accuracy, reproducibility and easiness for obtaining an appropriate echocardiographic window than M-mode echocardiography. The aim of this study was to assess echocardiographic parameters associated with pulmonary arterial hypertension, defined by increasing right ventricular systolic pressure(RVSP), calculated from trans-tricuspid gradient in patients with chronic hypoxic lungs. Method : We examined 19 patients with chronic hypoxic lung disease, suspected pulmonary hypertension under the clinical guidelines by two dimensional echocardiography via the left parasternal and subcostal approach in a supine position. Doppler echocardiography measured RVSP from tricuspid regurgitant velocity in continuous wave with 2.5MHz transducer and acceleration time(AT) on right ventricular outflow tract in pulsed wave for the estimation of pulmonary arterial pressure. Results : On echocardiography, moderate to severe degree of pulmonary arterial hypertension was defined as RVSP more than 40mmHg, presenting tricuspid regurgitation. Increased right ventricular endsystolic diameter and shortened AT were noted in the increased RVSP group. Increased RVSP was correlated negatively with the shortening of AT. Other clinical data, including pulmonary functional parameters, arterial blood gas analysis and M mode echocardiographic parameters were not changed significantly with the increased RVSP. Conclusion : These findings suggest that shortened AT on pulsed doppler can be useful when quantifying pulmonary arterial pressure with increased RVSP in patients with chronic lung disease with hypoxemia. Doppler echocardiography in pulmonary hypertension of chronic hypoxic lungs is an useful option, based on noninvasiveness under routine clinical practice.

  • PDF

Long-Term Results for Repair of Pulmonary Atresia with Intact Ventricular Septum (온전한 심실중격를 가진 폐동맥 폐쇄증에 대한 수술적 치료의 장기 결과)

  • Lee Chang-Ha;Hwang Seong Wook;Lim Hong Gook;Kim Woong-Han;Kim Chong Whan;Lee Cheul
    • Journal of Chest Surgery
    • /
    • v.38 no.6 s.251
    • /
    • pp.403-409
    • /
    • 2005
  • Pulmonary atresia with intact ventricular septum is morphologically heterogeneous, and the surgical outcome remains suboptimal compared to other complex congenital heart defects. We evaluated the long-term results for repair of pulmonary atresia with intact ventricular septum, Material and Method: Between January 1992 and June 2004, 38 patients underwent repair of pulmonary atresia with intact ventricular septum. The average age was 18 days $(2\~382\;days)$. The average Z-value of the tricuspid annulus diameter was -3.1$(-5.6\~0.8)$. Thirteen $(36\%)$ patients had right ventricle-to-coronary artery fistulas, and $4(11\%)$ patients had right ventricle-dependent coronary circulation. Average follow-up was 55 months $(3\;months\~2.2\;years)$, Result: Twenty-four patients under-went initial right ventricle (RV) decompression and 14 patients underwent systemic-to-pulmonary arterial shunt only. The average size of the tricuspid annulus of the patients who underwent RV decompression was significantly larger than that of the patients who underwent systemic-to-pulmonary arierial shunt only (Z-value -2.2 vs. -4.8, p=0.000). There were $5(13\%)$ early and 1 late deaths. Early deaths occurred in 3 patients who had undergone RV decompression, and in 2 patients who had undergone systemic-to-pulmonary arterial shunt only (p=1.0). Biventricular repair was achieved in $12(32\%)$ patients, single ventricular repair in $8(21\%)$, and one and a half ventricular repair in $4(l1\%)$ patients. Nine $(24\%)$ patients are waiting for the definitive repair. Kaplan-Meier survival at 5 and 8 years was $83.2\%$, respectively. Conclusion: Most of the deaths occurred after the initial palliation. Overall long-term survival was satisfactory. Early mortality should be reduced with careful preoperative evaluation and proper surgical strategy.

Long-Term Clinical Results with the St. Jude Medical Cardiac Valve Prosthesis (St. Jude Medical판막치 환술의 장기 임상성적)

  • 김윤규;류지윤
    • Journal of Chest Surgery
    • /
    • v.29 no.9
    • /
    • pp.964-970
    • /
    • 1996
  • One hundred eight patients (Feb.'86, through Jan.'96) underwent 53 mitral(MVR), 20 aortic(AVR), )5 double(DVR) valve replacement with SJM prosthesis. There were 55 males and 53 females whose mean age was 36.3 $\pm$ 10.4 years. We used 143 valves in mitral(88), aortic(54), and tricuspid(1) sites. The size and number of valves were 31 mm(32). 33inm(23), 29mm(20), 27mm(10), 25mm(2), and 35mm(1) in mitral site; 2)mm(21), 21mm(1 S), 19mm(7), 25mm(5), 27mm(2), and 33mm(1) in aortic site; and Blmm(1) in tricuspid site. Preoperative NYHA functional classes were II(14), III(73) and IV(21), and which were improved into I(89) and II(16) postoperatively. Early postoperative complications occurred in 15 cases(13.9%) in which LOS was the most common one(5 cases; 4.6%). fatly hospital death occurred in 3 cases(2.8%) due to LOS(1) and sudden cardiac arrest(2) he cummulative total follow-up period was 437.6 pl-yr with a mean of 4.1$\pm$2.9 years. There were 5 events of valve related'complications (2 TE, 1 paravalvular leak, 1 TE+paravalvular leak, 1 PVE) with the occurrence rate as 1.14%/pt-yr. Reoperation was performed in 2 cases and there were 2 cases of valve related death due to one PVE and one paravalvlllar leak. The complication free rate was 91.4$\pm$ ).4% at 10 years. Actuarial survival rate was 93.6 $\pm$ 3.1 % at 10 years.

  • PDF

Epicardial Repair of Acute Atrioventricular Groove Disruption Complicating Mitral Valve Replacement - A case report - (승모판막치환술 후 발생한 급성 제1형 좌심실 파열에 대한 심외막적 봉합 - 1예 보고 -)

  • Cho, Kwang-Ree;Kang, Jae-Geul;Jin, Sung-Hoon
    • Journal of Chest Surgery
    • /
    • v.40 no.12
    • /
    • pp.855-858
    • /
    • 2007
  • A left ventricular rupture might be one of the most disastrous complications after a mitral valve replacement. An acute atrioventricular groove rupture (type I) was detected in a 54-year-old female diagnosed with a mitral stenosis combined with severe tricuspid regurgitation. She had a prior medical history of an open mitral commissurotomy in Japan at 30 years ago. The surgical findings suggested that the previous procedure was not a simple commissurotomy but a commissurotomy combined with a posteromedial annuloplasty procedure. After a successful mitral valve replacement and a measured (De Vega type) tricuspid annuloplasty, the weaning from a cardiopulmonary bypass was uneventful. However, copious intraoperative bleeding from the posterior wall was detected and the cardiopulmonary bypass was restarted. Exposure of the posterior wall of the left ventricle showed bleeding from the atrioventricular groove 3 cm lateral to the left atrial auricle. Under the impression of a Type I left ventricular rupture, epicardial repair (primary repair of the Teflon felt pledgetted suture, continuous sealing suture using auto-pericardial patch and application of fibrin-sealant) was attempted. Successful local control was made and the patient recovered uneventfully. The patient was discharged at 14 postoperative days without complications. We report this successful epicardial repair of an acute type I left ventricular rupture after mitral valve replacement.

Long Term Experience of Mitral Valve Replacement (승모판치환수술의 장기 임상성적)

  • 조용길;류지윤
    • Journal of Chest Surgery
    • /
    • v.29 no.10
    • /
    • pp.1102-1110
    • /
    • 1996
  • Between Oct. 1985 and July 1995, 230 patients underwent mitral valve replacement. There were 77 men and 153 women whose mean age was 35.7 years, range 9 to 62 The concomitant operations were 40 aortic valve replacements(17.4%), 25 tricuspid annuloplasties(10.4%), 8 aortic valve replacements & tricuspid annuloplasties(3.5%), 2 tricuspid valve replacements(0.9%) and others, We used 139 mechanical (76 51. Jude medical, 33 CarboMedics, 30 Sorin) and 91 tissue 386 Carpentier-Edwards, 5 lonescu-Shiley) valves. The early postoperative complications occurred in 28 cases. There were 8 low cardiac output syndrome, 5 pleural effusion, 3 significant arrhythmia, 2 cardiac rupture and others. There were 6 early hospital deaths (2.6%) due to low cardiac output syndrome(2), arrhythmia(2) and ventricul r rupture(2). The cuAmulative notal follow-up period was 764. 4 patient-years with a mean of 4).9 months. The long term follow-up information was available for 212 patients(94.6%). There were 21 cases of valve-related complications. Prosthetic valve failure(10), anti-coagulation related bleeding (5), prosthetic valve endocarditis (4), and thromboembolism (2) occurred at rates of 1.3, 0.7, 0.5, and 0.3%Ipt-yr respectively. Late death occurred In 5 cases (0.7%/pt-yr) associated with prosthetic valve endocarditis (2), heart failure (2) and anti-coagulation related bleeding (1). There was no difference in the rate of freedom from prosthetic valve failure between the mechanical and tissue valve group at 6 years (100%), but there was significant difference at 9 years between the tissue (34.4%) and mechanical valve (100%) group (p=0.032). Actuarial survival rates were 98. 8% in tissue valve. 9).7% in mechanical valve group and 96.6% in total patients at 9 years.

  • PDF

Bivenrticular Repair of Double Outlet Right Ventricle with Remote Ventricular Septil Defect. (비상관성 심실중격결손중을 동반한 양대혈관우심실기시증 환자에서의 양심실성 교정)

  • 방정현;이영탁
    • Journal of Chest Surgery
    • /
    • v.30 no.7
    • /
    • pp.641-646
    • /
    • 1997
  • Understanding of the surgical anatomy of patients with double outlet right ventricle (DORV) is important in the planning of biventricular repair From May 1995 to September 1996, 7 patients underwent biventricular repair for DORV with remote ventricular septal defect. There were 5 males and 2 (tamales. Age at operation varied from 2 to 9 years(mean 3.4$\pm$ 2.7years). Preoperative diagnostic assessment was made by two-dimensional echocardiography and cardiac catheterization. Ventricular septal defect was perimembranous inlet type in all patients. Associated cardiac anomalies were pulmonary atresia in two, pulmonary stenosis in five and tricuspid chordal attachment to zonal septum in five. The operations were performed intraventricular repair and pulmonary enlargement in two, REV operation in two, and Rastelli operation in three. There was no early postoperative deaths and complications. The follow-up period war from 1 month to 18mon1hs, averaging 10: 6.1 months. In the past, we considered the Fontal operation indicative as primary choice when DORV was associated with abnormal tricuspid chordal attachment to the zonal septum, but now we believe that biventricular repair is feasible for those cases by making conal flap or reattachment method. Biventricular repair has theoretic advantages because it estabilishes normal anatomy and physiology, and it was concluded that the precise preoperative evaluation using both echocardiography and cardiac catheterization was essential to the successful surgery.

  • PDF