Inhibition of Over-oxidation of 11$\beta$-l7$\alpha$, 21-trihydroxy-pregna-1, 4-diene-3, 2-dione in Fermentative Process. (Prednisolone 발효중의 산화분해 저지법)

  • Bae, Moo
    • Microbiology and Biotechnology Letters
    • /
    • v.2 no.3
    • /
    • pp.127-131
    • /
    • 1974
  • Inhibition of over-oxidation of prednisolone in the fermentation has been studied by using vegetative cells as enzyme source. firstly, A. simplex (ATCC 6946) was demonst.ated to degrade p.ednisolone in the vegetative culture of the microorganism. Over 72% of hydrocortisone was transformed into prednisoloneby 3 hours of the fermentation. However, the prednisolone produced was considerably oxidized forming over-oxidation product in 8hours of fermentation period with the intact cells. Secondly, in order to depress the over-oxidation and the breakdown of the steroid skeleton of prednisolone, chelating agents such as $\alpha$$\alpha$'-dipyridyl, o-phenanthroline and 8-hydroxyruinoline were added to the fermentation broth. Conseauently, the breakdown of prednisolone by the iutact cells was able to be remarkably retatded and an intermediate regarded as an oxidized product derived from prednisolone was accumulated, by the addition of $\alpha$$\alpha$'-dipytidyl in the fermentation.

  • PDF

High Temperature Steam Electrolysis for Production of Hydrogen Using SOFC (스팀으로부터 고체산화물 연료전지를 이용한 수소제조)

  • Kang, Jung-Shik;Shim, Jae-Geum;Lee, Sang-Deuk;Lee, Byoung-Kyon;Hong, Suck-In;Moon, Dong-Ju
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2006.11a
    • /
    • pp.455-458
    • /
    • 2006
  • 최근 들어 고체산화물 연료전지(SOFC) 기술이 급성장함에 따라 고온 수증기 전기분해(HTE) 기술이 물로부터 수소를 대량으로 제조할 수 있는 환경 친화적인 기술로 주목 받고 있다 고온 수증기 전기분해는 기존의 액상 전기분해보다 총 에너지 요구량이 작고 전기분해에 필요한 최소의 전기에너지가 온도가 증가할수록 감소하며 고온 수증기 전기분해에 요구되는 에너지의 일부를 전기에너지 대신 열의 형태로 공급이 가능하여 보다 높은 효율을 기대할 수 있다. 따라서 off peak시 기저부하전력을 이용하고, 공정의 열원으로 고온가스의 폐열, 천연가스의 부분산화 반응열 또는 고온 가스원자로의 폐열을 활용하면 SOFC 이용 고온 수증기 전기분해 공정은 수소경제사회에서 요구되는 수소를 대량으로 제조할 수 있는 경제적인 공정이 될 것이다.

  • PDF

유류오염 토양의 화학.생물학적 통합처리 과정 중의 미생물 군집 변화

  • Choi Jeong-Hye;Bae Jae-Sang;Park Yeon-Jeong;Kim Su-Gon;Go Seong-Cheol
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2006.04a
    • /
    • pp.29-32
    • /
    • 2006
  • 화학적 산화처리와 bioremedation 기법을 개별적 또는 복합적으로 동시에 적용함으로써 한 개별 기법의 단점을 보완하고 현장적용성을 증대시킬 수 있는 통합기법을 개발하고자 하였다. 펜톤유사 반응을 통해 고농도의 유류를 산화분해 시킨 후 미생물 처리를 통해 잔류 유류 오염물질을 제거하고자 하였다. 유류 오염토양의 화학 생물학적 통합처리 공정의 현장 적용성 및 토양 미생물에 미치는 영향을 검증하기 위해 처리과정 전 후의 미생물 군집구조를 분석하였다. 또한 토양 내 유류 분해균을 분리하기 위해 탄소원으로 경유와 벙커C를 이용하여 농화배양을 수행하였다. 경유 분해균 10여종, 벙커 C 분해균 6종을 분리하여 분해능 및 동정을 시도하였다. 또한 유류 분해미생물의 consortia를 분자생물학적 기법으로 분석을 시도하였다.

  • PDF

3, 4성분계 DSA 전극의 제조와 성능 평가

  • Park, Yeong-Sik;Kim, Dong-Seok
    • Proceedings of the Korean Environmental Sciences Society Conference
    • /
    • 2008.11a
    • /
    • pp.482-487
    • /
    • 2008
  • 성능이 우수한 다성분계 전극을 개발하기 위하여 Ru를 주 전극성분으로 Pt, Sn, Sb 및 Gd를 보조 전극성분으로 하여 3, 4성분계 전극의 성능과 산화제 생성량 및 전극 표면 분석을 행하여 다음의 결과를 얻었다. 1. 2분 동안 단위 W당 제거된 RhB 농토는 Ru:Sn:Sb=9:1:1 > Ru:Pt:Gd=5:5:1 > Ru:Sn=9:1 > Ru:Sn:Gd=9:1:1 > Ru:Sb:Gd=9:1:1로 나타났다. Ru:Sn:Sb=9:1.1 전극에서 발생하는 free Cl, ClO$_2$ 및 H$_2$O$_2$농도가 다른 전극보다 높은 것으로 나타나 산화제 생성경향과 RhB 분해율과는 상관관계가 있는 것으로 사료되었다. 4성분계 전극 중에서 Ru:Sn:Sb:Gd 전극의 성능이 가장 우수한 것으로 나타났으나 3성분계 전극인 Ru:Sn:Sb=9:1.1 전극보다 성능이 떨어지는 것으로 나타났다. Ru:Sn:Sb=9:1:1 전극에서 생성되는 산화제 농도가 다른 두 종류의 산화제 농도보다 높은 것으로 나타났고 4성분 전극의 경우 Ru:Sn:Sb:Gd 전극의 산화제 농도가 Ru:Sn:Sb:Gd 전극이 높거나 유사한 경우로 나타나 산화제 생성 경향과 RhB분해 능과는 상관관계가 있는 것으로 나타났다. 초기 RhB 분해 속도가 높은 전극의 COD 제거율도 높은 것으로 나타났다. OH 라디칼은 발생하지 않지만 염소계 산화제 농도가 높고 RhB제거율이 높아 Ru를 주 성분으로 한 전극의 RhB분해는 주로 간접 산화작용에 의한 것이며, 개발된 3, 4성분계 산화물 전극은 간접 산화용 전극임을 알 수 있었다. 에칭을 하기 전의 Ti판은 표면이 매끄러운 것으로 나타났으며, 35% 염산으로 에칭한 후의 Ti메쉬는 매우 거친 표면조직을 가지는 것을 관찰할 수 있었다. Ru:Sn:Sb=9:1:1 전극과 Ru:Sn:Sb:Gd 전극의 SEM 사진을 관찰한 결과 두 전극 모두 전극 물질이 균일하게 도포되어 있었으며, 두 전극 모두 열소성을 통해 전극 성분을 코팅할 때 발생하는 "mud crack"이 발생한 것이 관찰되었다 EDX 분석에서 Cl이 관찰되었는데, 전극 성분의 불완전 산화로 인한 비양론적 산화물 때문이며 이는 RhB 분해성능과 관련 있는 것으로 사료되었다.

  • PDF

A study on the Ozone oxidation of Diesel-contaminated Groundwater (디젤로 오염된 지하수의 오존산화처리에 대한 연구)

  • 권충일;공성호;김무훈
    • Journal of Korea Soil Environment Society
    • /
    • v.5 no.3
    • /
    • pp.3-15
    • /
    • 2001
  • The ozone kinetics including ozone auto-decomposition. effect of pH, and solubility were investigated. Diesel decomposition process including TCE & PCE decomposition. effect of hydroxyl radical scavenger, effect of pH, and ozone/$H_2O$$_2$by ozonation process were also examined using deionized water, simulated groundwater. and actual groundwater. Reactions with deionized water and groundwater both stowed the second-order reaction rates, and the reaction rate was much higher in groundwater (half-life of 14.7 min) than in deionized water (hal(half-life of 37.5 min). The reaction rate was accelerated at high pH values in both waters. The use of ozone showed high oxidation rates of TCE. PCE and diesel. Though hydroxyl radical scavengers existing in groundwater were inhibitors for treating diesel, high pH condition and addition of hydrogen peroxide could accelerate to degrade diesel in groundwater, indicating ozone oxidation process could be applied to treating diesel contaminated-groundwater.

  • PDF

Decomposition of Dye Chemicals by Electrolytic Oxidation Method (전기분해법을 이용한 염료분해에 관한 연구)

  • Lee, Tae-Jin;Chun, Byoung Chul;Chung, Yong-Chan
    • Clean Technology
    • /
    • v.12 no.3
    • /
    • pp.145-150
    • /
    • 2006
  • Electrolysis of aqueous solution produces hydroxide ions and proton ions for the hydrolysis of reactive organic compounds, and oxidizing agent such as hypochlorite ions for the oxidative decomposition of organic chemicals. Electrolytic decomposition of dying chemicals was tested with our custom made system, and analyzed by HPLC and UV-VIS spectrophotometer. The electrolytic system could decompose dying chemicals with very high reactivity and low cost. Disposal of byproduct and refill of reactant during electrolysis was not necessary. Decomposition time of dying chemicals is compared under similar conditions, and application to water purification is discussed.

  • PDF

Manganese Oxide Catalyzed Fenton-like Reduction of Chlorinated Compounds (산화망간으로 촉매화된 펜톤유사반응을 적용한 염소계화합물의 환원분해)

  • 김상민;공성호;김용수
    • Journal of Soil and Groundwater Environment
    • /
    • v.7 no.3
    • /
    • pp.95-102
    • /
    • 2002
  • Manganese oxide/ hydrogen peroxide($MnO_2$/${H_2}{O_2}$) reactions were investigated as an alternative to Fenton-like reaction to reduce chlorinated organic compounds in groundwater This system showed high degradation of CT with low ${H_2}{O_2}$concentration($\leq$294mM) at neutral condition, and CT degradation increased with increasing pH values. The rate of CT degradation was not so much dependent on increase in $MnO_2$concentration since increase in production of oxygen during the reaction obstructed reaction of ${H_2}{O_2}$ on the surface of $MnO_2$. These results show that $MnO_2$catalyzed Ponton-like reaction could be a potential alternative method for treating chlorinated organic compounds in groundwater.

1, 2성분계 DSA 전극의 제조와 성능 평가

  • Park, Yeong-Sik;Kim, Dong-Seok
    • Proceedings of the Korean Environmental Sciences Society Conference
    • /
    • 2008.11a
    • /
    • pp.464-467
    • /
    • 2008
  • 성능이 우수한 다성분계 전극을 개발하기 위하여 Pt, Ru, Sn, Sb 및 Gd의 5 종류 금속을 이용하여 1성분계 전극의 성능과 산화제 생성량 및 2성분계 전극의 성능과 산화제 생성 경향을 고찰하여 다음의 결과를 얻었다. 1. RhB 농도 감소는 Ru/Ti > Sb/Ti > Pt/Ti > Sn/Ti > Gd/Ti 전극의 순서로 나타났으나 단위 전력당 2분간 제거된 RhB 농도 감소는 Ru/Ti > Sb/Ti > Pt/Ti > Gd/Ti > Sn/Ti 전극의 순서로 나타났다. 생성된 산화제 농도는 ClO$_2$ > free Cl > H$_2$O$_2$ > O$_3$의 순서였으며 Gd/Ti 전극의 경우 산화제가 거의 생성되지 않는 것으로 나타났다. 모든 전극에서 OH 라디칼이 거의 생성되지 않는 것으로 나타났다. Ru/Ti와 Sb/Ti 전극의 높은 RhB 분해와 산화제 생성 농도는 정확하지는 않지만 상관관계가 있는 것으로 나타났다. 2. Ru계 2성분 전극(Ru-Gd/Ti, Ru-Pt/Ti, Ru-Sn/Ti 및 Ru-Sb/Ti)은 모두 1성분계 전극보다 RhB 분해성능이 높아지는 것으로 나타났으며, Ru계 2성분 전극 중 가장 성능이 우수하였던 전극은 Ru:Sn=9:1 전극으로 나타났다. Sn-Sb/Ti 전극은 Sn:Sb=1:9의 전극 성능이 우수한 것으로 나타났으나 Sb/Ti 전극과의 차이는 크지 않은 것으로 나타났다. Pt계 전극(Pt-Gd/Ti, Pt-Sn/Ti, Pt-Sb/Ti)은 대체로 두 성분 혼합에 따른 RhB 분해효과 상승은 없는 것으로 나타났다. 2성분계 전극 중 RhB 제거 성능이 가장 우수하였던 Ru:Sn=9:1 전극에서 4종류의 산화제 생성 농도가 높은 것으로 나타났다. Ru:Pt=9:1 전극은 RhB 분해 성능이 5 전극 중 가장 낮았으며, 산화제도 생성량이 가장 적은 것으로 나타났다. Ru-Sn/Ti 계 전극의 RhB 분해 성능과 산화제 생성 농도가 실험한 모든 1, 2성분계 전극에서 높은 것으로 나타나 향후 3, 4성분계 전극 제조시 이를 바탕으로 제조하고 다른 물질들은 보조재료로서 사용할 필요성이 있는 것으로 사료되었다.

  • PDF

전기화학적으로 생성되는 Ag(II)에 의한 유기성 고체폐기물의 분해

  • 최왕규;이근우;김영민;박상윤;오원진
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1998.05b
    • /
    • pp.557-562
    • /
    • 1998
  • 방사성 물질로 오염된 유기성 고체폐기물의 분해를 위한 전기화학적 매개산화 공정을 개발할 목적으로 대상 폐기물로 셀룰로오스, latex 고무 및 플라스틱 물질에 대한 분해연구를 수행하였다. 매개체로써 Ag(II)를 사용하는 전기화학적 매개산화 공정에서 제어 가능한 인자인 전류밀도, 양극전해질의 농도 및 온도 등이 유기성 고체기물의 분해거동에 미치는 영향을 고찰하였다. 본 실험에서 사용한 유기성 고체폐기물은 전기화학적으로 생성되는 Ag(II)에 의해서 완전히 이산화탄소로 분해 되었으며, 한계전류밀도 이하에서 셀룰로오스 물질에 대해서는 80 %, latex 고무에 대해서는 76 %, 그리고 폴리프로필렌 물질에 대해서는 85 % 이상의 비교적 만족스러운 전류효율을 얻을 수 있었다. 질산의 농도 변화는 셀룰로오스 및 폴리프로필렌 물질의 분해에는 별 영향을 미치지 않았으나, latex 고무에 대해서는 비교적 큰 영향을 주었다. 또한 온도의 변화는 셀룰로오스 물질의 분해에는 거의 영향을 미치지 않았으나, latex 고무 및 폴리프로필렌 물질의 분해에는 비교적 큰 영향을 주었지만 전류효율 측면에서 85$^{\circ}C$ 이하에서 조업하면 충분함을 알 수 있었다. 결론적으로, Ag(II)에 의한 전기화학적 매개산화 공정은 혼성폐기물 중의 유기물을 저온에서 안전하게 분해 시킬 수 있으며, 소각 공정을 대체할 수 있는 한가지 방법이 될 수 있음을 확인하였다.

  • PDF