• Title/Summary/Keyword: 산소확산

Search Result 335, Processing Time 0.025 seconds

The Differences in Resting Pulmonary Function in Relation to the Nutritional status of Patients with Chronic Obstructive Pulmonary Disease (만성폐쇄성폐질환 환자의 영양상태에 따른 안정시 폐기능 차이)

  • Mun, Yeung-Chul;Yu, Sung-Keun;Park, Hye-Jung;Park, Jong-Won;Shin, Kyeong-Cheol;Chung, Jin-Hong;Lee, Kwan-Ho;Kim, Jung-Soon
    • Tuberculosis and Respiratory Diseases
    • /
    • v.51 no.6
    • /
    • pp.570-578
    • /
    • 2001
  • Background: With cases of chronic obstructive pulmonary disease(COPD), weight loss and low body weight have been found to correlate with increased mortality and poor prognosis. Therefore, nutritional aspects are an important part of the treatment in cases of COPD. In Korea, there is only limited data available for the changes of resting pulmonary function in relation to nutritional status. This study was carried out to investigate the differences of resting pulmonary function in relation to the nutritional status of patients with COPD. Method : 83 stable patients, with moderate to severe COPD, were clinically assessed for their nutritional status and resting pulmonary function. The patients' nutritional status was evaluated by body weight and fat-free mass (FFM), which was assessed by bioelectrical impedance analysis. According to their nutritional status, the 83 patients were divided into two groups, designated as the depleted, and non-depleted, groups. Result : Of the 83 patients, 31% were characterized by body weight loss and depletion of FFM, whereas 28% had either weight loss or depleted FFM. In the depleted group, significantly lower peak expiratory flow rate(p<0.05) and Kco(p<0.01), but significantly higher airway resistance(Raw, p<0.05) were noted. There was no difference for the non-depleted group in forced expiratory volume at one second, residual volume, inspiratory vital capacity, or total lung capacity. Maximal inspiratory pressure($P_{Imax}$) was also significantly lower in the depleted group(p<0.05). Conclusion : We conclude, from our clinical studies, that nutritional depletion is significantly associated with the change in resting pulmonary function for patients with moderate to severe COPD.

  • PDF

Analyze of I-V Characteristics and Amorphous Sturcture by XRD Patterns (XRD 패턴에 의한 비정질구조와 I-V 특성분석)

  • Oh, Teresa
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.7
    • /
    • pp.16-19
    • /
    • 2019
  • A thinner film has superior electrical properties and a better amorphous structure. Amorphous structures can be effective in improving conductivity through a depletion effect. Research is needed on the Schottky contact, where potential barriers are formed, as a way to identify these characteristics. $SiO_2/SnO_2$ thin films were prepared to examine the amorphous structure and Schottky contact, $SiO_2$ thin films were prepared using Ar = 20 sccm. $SnO_2$ thin films were deposited using mixed gas with a flow rate of argon and oxygen at 20 sccm, and $SnO_2$ thin films were added by magnetron sputtering and treated at $100^{\circ}C$ and $150^{\circ}C$. To identify the conditions under which the amorphous structure was constructed, the XRD patterns were investigated and C-V and I-V measurements were taken to make Al electrodes and perform electrical analysis. The depletion layer was formed by the recombination of electrons and holes through the heat treatment process. $SiO_2/SnO_2$ thin films confirmed that the pores were well formed when heat treated at $100^{\circ}C$ and an electric current was applied over the micro area. An amorphous $SiO_2/SnO_2$ thin film with heat treatment at $100^{\circ}C$ showed no reflection at $33^{\circ}\;2{\theta}$ in the XRD pattern, and a reflection at $44^{\circ}2\;{\theta}$. The macroscopic view (-30 V

Efficacy and Safety Evaluation of an Air Sterilizer Equipped With an Electrolytic Salt Catalyst for the Removal of Indoor Microbial Pollutants (염촉매 전기분해 공기살균기의 효능 평가)

  • Sun Nyoung Yu;Ho-Yeon Jeon;Bu Kyung Kim;Ae-Li Kim;Kyung Il Jung;Gye Rok Jeon;Soon Cheol Ahn
    • Journal of Life Science
    • /
    • v.34 no.7
    • /
    • pp.500-508
    • /
    • 2024
  • Recently, there has been increasing interest in enhancing the indoor air quality, particularly in response to the growing utilization of public facilities. The focus of this study was on assessing the efficacy and safety of an air sterilizer equipped with electrolytic salt catalysts. To that end, we evaluated the antimicrobial activity of the vapor spraying from the air sterilizer and its cytotoxicity in condensed form on human cell lines (HaCaT, BEAS-2B, and THP-1). Against the test organisms, which comprised five bacterial strains (Staphylococcus aureus, Bacillus subtilis, Escherichia coli, Pseudomonas aeruginosa, Salmonella typhimurium) and one fungal strain (Candida albicans), the air sterilizer exhibited relatively high antimicrobial activities ranging from 10.89 to 73.98% following 1 and 3 hr of vapor spraying, which were notably time-dependent. Importantly, cytotoxicity assessments on human cells indicated no significant harmful effect even at a 1.0% concentration. Comprehensive safety evaluations included morphological observations, gene expression (Bcl-2, Bax) tests, and FACS analysis of intracellular ROS levels. Consistent with previous cytotoxicity findings, these estimates demonstrated no significant changes, highlighting the air sterilizer's safety and antimicrobial activities. In a simulated 20-hr operation within an indoor environment, the air sterilizer not only showed an 89.4% removal of total bacteria but also a 100.0% removal of Escherichia sp. and fungi. This research outlines the potential of the developed electrolytic salt catalyst air sterilizer to effectively remove indoor microbial pollutants without compromising human safety, underscoring the solution that it offers for improving indoor air quality.

The Effect of Pulmonary Rehabilitation in Patients with Chronic Lung Disease (만성 폐질환 환자에서의 호흡재활치료의 효과)

  • Choe, Kang Hyeon;Park, Young Joo;Cho, Won Kyung;Lim, Chae Man;Lee, Sang Do;Koh, Youn Suck;Kim, Woo Sung;Kim, Dong Soon;Kim, Won Dong
    • Tuberculosis and Respiratory Diseases
    • /
    • v.43 no.5
    • /
    • pp.736-745
    • /
    • 1996
  • Background : It is known that pulmonary rehabilitation improves dyspnea and exercise tolerance in patient with chronic lung disease, although it does not improve pulmonary function. But there is a controversy whether this improvement after pulmonary rehabilitation is due to increased aerobic exercise capacity. We performed this study to evaluate the effect of pulmonary rehabilitation for 6 weeks on the pulmonary function, gas exchange, exercise tolerance and aerobic exercise capacity in patients with chronic lung disease. Methods : Pulmonary rehabilitations including education, muscle strengthening exercise and symptom-Umited aerobic exercise for six weeks, were performed in fourteen patients with chronic lung disease (COPD 11, bronchiectasis 1, IPF 1, sarcoidosis 1 ; mean age $57{\pm}4$ years; male 12, female 2). Pre- and post-rehabilitaion pulmonary function and exercise capacity were compared. Results: 1) Before the rehabilitation, FVC, $FEV_1$ and $FEF_{25-75%}$ of the patients were $71.5{\pm}6.4%$. $40.6{\pm}3.4%$ and $19.3{\pm}3.8%$ of predicted value respectively. TLC, FRC and RV were $130.3{\pm}9.3%$, $157.3{\pm}13.2%$ and $211.1{\pm}23.9%$ predicted respectively. Diffusing capacity and MVV were $59.1{\pm}1.1%$ and $48.6{\pm}6.2%$. These pulmonary functions did not change after pulmonary rehabilitation. 2) In the incremental exercise test using bicycle ergometer, maximum work rale ($57.7{\pm}4.9$) watts vs. $64.8{\pm}6.0$ watts, P=0.036), maximum oxygen consumption ($0.81{\pm}0.07$ L/min vs. $0.96{\mu}0.08$ L/min, P=0.009) and anaerobic threshold ($0.60{\pm}0.06$ L/min vs. $0.76{\mu}0.06$ L/min, P=0.009) were significantly increased after pulmonary rehabilitation. There was no improvement in gas exchange after rehabilitation. 3) Exercise endurances of upper ($4.5{\pm}0.7$ joule vs. $14.8{\pm}2.4$ joule, P<0.001) and lower extremity ($25.4{\pm}5.7$ joule vs. $42.6{\pm}7.7$ joule, P<0.001), and 6 minute walking distance ($392{\pm}35$ meter vs. $459{\pm}33$ meter, P<0.001) were significantly increased after rehabilitation. Maximum inspiratory pressure was also increased after rehabilitation ($68.5{\pm}5.4$ $CmH_2O$ VS. $80.4{\pm}6.4$ $CmH_2O$, P<0.001). Conclusion: The pulmonary rehabilitation for 6 weeks can improve exercise performance in patients with chronic lung disease.

  • PDF

Survey of Current Status of the Patients with Home Ventilator in Seoul and Kyunggi Province (가정용 인공호흡기를 사용하는 서울 및 경기 지역 환자의 실태)

  • Ahn, Jong-Joon;Lee, Ki-Man;Shim, Tae-Sun;Lim, Chae-Man;Lee, Sang-Do;Kim, Woo-Sung;Kim, Dong-Soon;Kim, Won-Dong;Koh, Youn-Suck
    • Tuberculosis and Respiratory Diseases
    • /
    • v.49 no.5
    • /
    • pp.624-632
    • /
    • 2000
  • Background : Home ventilation can decrease hospital-acquired infection, increase physical activity, improve nutritional status, enhance quality of life, and reduce medical costs. The number of patient using home ventilators has been increasing, particularly in Europe and United States. Although the number of patients with home ventilation has been increasing in Korea, the current status of these patients is not well known. This study was undertaken to obtain basic information upon these patients in addition to evaluating any problems related to patients' home care in our country. Methods : A register of 92 patients with home ventilators in Seoul and Kyunggi Province were obtained from commercial ventilator supply companies. The patients were contacted by phone and 29 of them accepted our visit. Information concerning education about home care before discharge, equipment cost, and problems related to home care were documented. The mode and preset variables of the home ventilator were checked; tidal volume (TV), peak airway pressure, and oxygen saturation were measured. Results : There were 26 males (90%) and their mean age was 48.0 (${\pm}20.1$) years. The underlying diseases were : 21 neuromuscular disorders, 2 spinal cord injuries, 6 chronic lung diseases. Among the caregivers, spouses (n=14) predominated. Education for home care before discharge was performed primarily by intensive care unit nurses and the education for ventilator management by commercial companies. Twenty-five of the 29 patients had tracheostomies. Volume targeted type (VTT ; n=20, 69%) was more frequently used than the pressure targeted type (PTT). Twenty-three of the 29 patients purchased a ventilator privately, which cost 7,450,000 (${\pm}$3,290,000) won for a PTT, and 14,280.000 (${\pm}$3,130,000) won for a VTT. Total cost for the equipment was 11,430,000 (${\pm}$634,000) won. The average cost required for home care per month was 1,120,000 (${\pm}$1,360, 000) won. Conclusion : The commonest underlying disease of the patients was neuromuscular disease. The VTT ventilator was primarily used with tracheostomy. Patients and their families considered the financial difficulties associated with purchasing and maintaining equipment for home care an urgent problem. Some patients were aided by a visiting nurse, however most patients were neglected and left without professional medical supervision.

  • PDF