• Title/Summary/Keyword: 사이클변화

Search Result 488, Processing Time 0.029 seconds

Effect of Cyclic Drying-Wetting on Compressive Strength of Decomposed Granite Soils (습윤-건조 반복작용으로 인한 화강풍화토의 압축강도 특성 변화 연구)

  • Yoo, Chung-Sik
    • Journal of the Korean Geosynthetics Society
    • /
    • v.10 no.4
    • /
    • pp.19-28
    • /
    • 2011
  • This paper presents the results of an investigation into the effect of cyclic wetting-drying on the compressive strength characteristics of decomposed granite soils. A series of plane strain compression (PSC) tests were performed on test specimens with varying fine contents under different wetting-drying cycles to investigate the change in compressive strength under the process of wetting-drying cycles. The effect of wetting-drying cycles on the structural particle rearrangement at a micro-scale level was also examined using scanning electron microscope (SEM) tests. It was shown that the soil containing larger fines showed more significant decrease in compressive strength compared with the soils with less fines. Also found was that the wetting-drying cycle did not have significant effect on the particle arrangement.

A Study on Intelligent Charge and Discharge Control for Secondary Battery (2차 전지의 지능형 충방전 제어에 관한 연구)

  • Im, Geun-Uk;Jo, Hyeon-Chan;Kim, Gwang-Seon;Yu, Sang-Gil;Choe, Gyeong-Deok;Gang, Hui-Seon
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 2008.04a
    • /
    • pp.37-40
    • /
    • 2008
  • 본 논문은 2차전지의 최적화된 충 ${\cdot}$ 방전 제어를 위한 지능형 제어 알고리즘을 제안한다. 고용량화된 2차 전지는 높은 에너지 밀도를 갖게 되고, 과충전에 의한 발화와 과방전에 의한 열화 특성으로 위험성이 존재하므로 정밀하게 전안, 전류를 제어하지 않으면 그 성능을 발휘하기 어렵다. 전지의 위험성을 제거하고 성능을 최대로 활용하기 위해서는 모든 전지 셀의 충방전 전류량을 조절하여 모든 전지의 셀간 전압 차이를 밸런스 제어 해야 한다. 하지만 전지의 특성에 영향을 미치는 임피던스가 사이클 라이프와 온도 변화 등 외부 환경에 의해 비선형적으로 변화하기 때문에 전지의 셀간 밸런스 제어에 어려움이 있다. 따라서 본 논문에서는 지능형 충 ${\cdot}$ 방전 제어 알고리즘을 이용하여 임피던스의 변화에도 적응 가능 하고 2차 전지가 가질 수 있는 최대 에너지를 사용할 수 있는 최적화된 방법을 제안한다. 또한 제안하는 알고리즘과 제어회로의 컴퓨터 시뮬레이션을 통해 그 효용성을 입증한다.

  • PDF

Temperature characteristics of condenser and evaporator of Air-conditioner applying variable capacity compressor under cooling condition (가변용량 압축기를 적용한 에어컨의 냉방운전 시 응축 및 증발온도 특성)

  • Kwon, Young-Chul;Chun, Chong-Keun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.8 no.6
    • /
    • pp.1325-1331
    • /
    • 2007
  • In order to investigate the cooling capacity of an air-conditioner applying a variable capacity compressor and the temperature characteristics on a condenser and an evaporator, the experiment on the operation characteristics of the air-conditioner was performed along a compressor operation ratio and an indoor/outdoor temperatures, under a cooling operation mode. The system characteristics were measured by the psychrometric calorimeter. The cooling capacity increased with decreasing the outdoor temperature and increasing the indoor temperature. Also, it increased with increasing the compressor operation ratio. The temperature of the condenser was more sensitive for the variation of the outdoor temperature and the temperature of the evaporator was more sensitive for the variation of the indoor temperature. The operation characteristics of the cycle used in this present were also analyzed by a pressure-enthalpy chart.

  • PDF

Application of One-Sided Stress Wave Velocity Measurement Technique to Evaluate Freeze-Thaw Damage in Concrete (콘크리트 동결-융해 손상의 비파죄 평가를 위한 One-Sided 응력파 속도 측정기법의 적용에 관한 연구)

  • Lee, Joon-Hyun;Park, Won-Su
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.20 no.4
    • /
    • pp.269-275
    • /
    • 2000
  • It is well recognized that damage resulting from freeze-thaw cycles is a serious problem causing deterioration and degradation of concrete. In general, freeze-thaw cycles change the microstructure of the concrete ultimately leading to internal stresses and cracking. In this study, a new method for one-sided stress wave velocity measurement has been applied to evaluate freeze-thaw damage in concrete by monitoring the velocity change of longitudinal and surface waves. The freeze-thaw damage was induced in a $400{\times}350{\times}100mm$ concrete specimen in accordance with ASTM C666 using s commercial testing apparatus. A cycle consisted of a variation of the temperature from -14 to 4 degrees Celsius. A cycle takes 4-5 hours with approximately equal times devoted to freezing-thawing. Measurement of longitudinal and surface wave velocities based on one-sided stress wave velocity measurement technique was made every 5 freeze-thaw cycle. The variation of longitudinal and surface wave velocities due to increasing freeze-thaw damage is demonstrated and compared to determine which one is more effective to monitor freeze-thaw cyclic damage progress. The variation in longitudinal wave velocity measured by one-sided technique is also compared with that measured by the conventional through transmission technique.

  • PDF

Influence of Precooling Cooling Air on the Performance of a Gas Turbine Combined Cycle (냉각공기의 예냉각이 가스터빈 복합발전 성능에 미치는 영향)

  • Kwon, Ik-Hwan;Kang, Do-Won;Kang, Soo-Young;Kim, Tong-Seop
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.36 no.2
    • /
    • pp.171-179
    • /
    • 2012
  • Cooling of hot sections, especially the turbine nozzle and rotor blades, has a significant impact on gas turbine performance. In this study, the influence of precooling of the cooling air on the performance of gas turbines and their combined cycle plants was investigated. A state-of-the-art F-class gas turbine was selected, and its design performance was deliberately simulated using detailed component models including turbine blade cooling. Off-design analysis was used to simulate changes in the operating conditions and performance of the gas turbines due to precooling of the cooling air. Thermodynamic and aerodynamic models were used to simulate the performance of the cooled nozzle and rotor blade. In the combined cycle plant, the heat rejected from the cooling air was recovered at the bottoming steam cycle to optimize the overall plant performance. With a 200K decrease of all cooling air stream, an almost 1.78% power upgrade due to increase in main gas flow and a 0.70 percent point efficiency decrease due to the fuel flow increase to maintain design turbine inlet temperature were predicted.

A Study on the Effect of Sulfur Content in Fuel Oil on the Emission of Air Pollutants According to Operating Conditions of Small Ship Engines (선박용 소형 엔진에서 연료유 내 황 함유량이 운전 조건에 따라 대기오염물질 배출에 미치는 영향에 관한 연구)

  • Lee, Kyeong-yeol;Rho, Beom-seok;Lee, Won-Ju;Choi, Jae-hyuk
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.24 no.6
    • /
    • pp.834-840
    • /
    • 2018
  • In this study, the characteristics of air pollutant emissions from ships' engines have been investigated by conducting E2 and E3 cycle mode tests. A engine 360Ps (Doosan L126TIH engine) and 400kW dynamometer Horiba-Schenck were utilized for engine tests. The FTIR analyzer and SPC were used to measure exhaust gas (NOx, SOx etc.) and PM (particulate matter), respectively. The results showed that the emissions of THC and CO produced from engine were increased with the increase of sulfur content in fuel oils at E2 and E3 cycle modes. The kinetic viscosity of the fuel increased as the sulfur content of the fuel increased, thereby the specific fuel oil consumption (SFC) of the engine improved. This result is considered to be due to improved combustion conditions due to increased average diameters of sprayed particles and due to increased kinetic viscosity under constant fuel injection pressure in this study. In the case of NOx emission, this study showed no significant change in amount of sulfur content.

Experimental Study on the Control Characteristics of Each Channel in a Semiconductor Chiller (반도체 공정용 칠러의 채널별 제어특성에 관한 실험적 연구)

  • Kim, Hyeon-Joong;Kwon, Oh-Kyung;Cha, Dong-An;Kim, Yong-Chan
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.12
    • /
    • pp.1285-1292
    • /
    • 2011
  • The characteristics of a semiconductor chiller system with EEV have been experimentally studied. Three experiments on temperature changes (increase and decrease), load variation, and control precision were conducted to investigate the operating characteristics of the semiconductor chiller. The power consumption was 8.9 kW during increase in temperature. The required time was 37.5 min for CH1 and 39.5 min for CH2. Moreover, the time required for falling temperature was 26.5 min. The control precision for partial load operation was relatively low compared to that of a full load operation. In addition, the CH2 equipped with a step motor showed better control precision. The power consumed by the chiller for process cooling water was 1.8 kW, which was one-half of that consumed during the refrigeration cycle. The objective of this study is to provide an optimal control guideline for the semiconductor chiller design.

Durability Test of PEMFC Membrane by the Combination of Chemical/Mechanical Degradation (화학적/기계적 열화 병행방법에 의한 PEMFC 고분자막 내구성 평가)

  • Lim, Daehyeon;Oh, Sohyeong;Jung, Sunggi;Jeong, Jihong;Park, Kwonpil
    • Korean Chemical Engineering Research
    • /
    • v.59 no.3
    • /
    • pp.339-344
    • /
    • 2021
  • In order to improve the PEMFC (Proton Exchange Membrane Fuel Cell) durability, it is important to accurately evaluate the durability of the membrane in a short time. Recently, DOE (Department of Energy) reported a protocol that combines the chemical and mechanical durability of membranes to evaluate them effectively. This protocol applies chemical/mechanical deterioration to the membrane by repeating wet/dry while OCV (Open Circuit Voltage) holding. The problem of this protocol is that it is highly affected by electrode degradation due to change cycles in OCV and that the evaluation time is long. By using oxygen instead of air as the cathode gas while leaving the other conditions of the DOE protocol as it is, the durability evaluation time could be reduced from 408 hours to 144 hours. By reducing the number of voltage change cycles to 1/3, the electrode degradation due to the voltage change cycle was reduced to 1/12 when oxygen was used compared to air at the end, thereby enabling more accurate evaluation of polymer membrane durability.

A Study of Recycling Lithium-ion Battery Graphite by Eco-friendly Citric Acid Treatment Method (친환경 구연산처리를 통한 폐흑연 재활용 연구)

  • Dong-kyu Son;Won Jin Park;Jun Young Kim;Ji Hui Yun;Jung Eun Hyun
    • Korean Chemical Engineering Research
    • /
    • v.62 no.3
    • /
    • pp.246-252
    • /
    • 2024
  • In this study, impurities such as Li and F were removed from waste graphite through citric acid treatment, and changes in structural properties, capacity, and cycle stability of regenerated graphite were observed accordingly. Regenerated graphite pretreated in a nitrogen atmosphere was treated with citric acid, and its structure and characteristics were analyzed through SEM (Scanning Electron Microscope), FT-IR (Fourier Transform Infrared spectroscopy), XRD (X-ray Diffraction), and XPS (X-ray Photoelectron Spectroscopy). Waste graphite that was not treated with acid had a rapid decrease in capacity before 70 cycles, but graphite that had been treated with citric acid showed a capacity of 302.9 mAh g-1 and a capacity retention rate of 93.1% at 100 cycles. In addition, despite changes in current density in rate performance, samples treated with citric acid showed 340.2 mAh g-1 performance at 1.0C without change in capacity. As a result, it was confirmed that citric acid treatment not only effectively removed impurities and showed a high capacity retention rate, but also showed stability even at high current densities.

The Strategic Ambidexterity of Online Game Companies: The Exploitation and Exploration of NCsoft (온라인 게임회사의 전략적 양면성: 엔씨소프트의 활용과 탐험)

  • Bae, Joonheui;Koo, Dong Mo
    • Journal of Korea Game Society
    • /
    • v.15 no.1
    • /
    • pp.115-124
    • /
    • 2015
  • This research analyzed the case of Ncsoft to study the organizational learning, exploitation and exploration that create dynamic capability in hypercompetitive environment. First of all, we demonstrated the activities of exploitation and exploration in Ncsoft according to the life cycle of online game industry. An exploitation related to routine, learning and fit with existing environment brings about incremental innovation. In contrast, an exploration associated with non-learning, flexibility with changing environment results in radical innovation. We examined them based on the life cycle of its various game services. NCsoft that built the leading position in online game industry focused the exploitation activities at the stage of beginning period and growth, whereas NCsoft has increased the activities of exploration at period of mature. In addition, the firm conducts an exploration for its brand new game services and R&D. Conversely, An exploitation is conducted for sustainable updating of patch service and marketing and system building. The result implies that online game companies create sustainable competitive advantage using the balance between exploitation and exploration.