• Title/Summary/Keyword: 사무용 건물

Search Result 33, Processing Time 0.022 seconds

Study of Design Strategy to Reduce Energy Consumption in a Standard Office Building (사무용 건물의 에너지 절감을 위한 요소별 성능 분석 및 디자인 전략에 관한 연구)

  • Yang, Ja-Kang;Kim, Chul-Ho;Kim, Kang-Soo
    • KIEAE Journal
    • /
    • v.16 no.2
    • /
    • pp.23-31
    • /
    • 2016
  • Purpose: Recently energy consumption is rapidly increasing due to continuous development of social evolution in various field. In this situation, there is a lot of effort to reduce this energy consumption in many ways, especially in building energy. Preceding studies already started to analyze the housing area such as zero energy house and passive house by researching annual building energy consumption, but to apply the results of housing to office building is insufficient since it has different consumption tendency. Method: In this study, eQuest program was used for simulation and the base model is selected among standard office building in ASHRAE 90.1. Variables are divided into passive and active factors for comparison. Result: In passive factors, glazing system showed the highest energy saving rate by 21.3% with triple low-e glass and enhancing wall u-value showed the lowest energy saving rate by 3.6% with 0.15 m2/K. In active factors, VAV system showed 30.9% energy saving rate when compared to CAV system, and heat exchanger showed 10.2% energy saving rate. For regeneration energy part, photovoltaic panel generated 10.4% of base annual energy usage.

A Comparative Analysis on Cooling Energy of Heat Recovery Ventilator and Air Handling Unit in the Office Building (사무용 건물에서 전열교환 환기시스템과 일반공조기의 냉방에너지 비교분석에 관한 연구)

  • Jang, Ji-Hoon;Kim, Hyeonsoo;Auh, Jin-Sun;Leigh, Seung-Bok;Kim, Byungseon-Sean
    • KIEAE Journal
    • /
    • v.16 no.6
    • /
    • pp.123-128
    • /
    • 2016
  • Purpose: In order to save the energy consumption of buildings, buildings have been constructed with high performance insulation or airtightness. However, high performance insulation or air tightness has led to a poor indoor air quality. Therefore, HRV(Heat Recovery Ventilator) has received attention to save the energy consumption and insure a good air quality. Because existing research is almost about the performance of HRV in residential buildings, This study analyzed the effect of HRV on cooling energy consumption in commercial office building. Method: This study was proceeded at commercial office building in In-cheon. In order to evaluate the energy consumption of HRV, this study proposed two methods: estimating energy consumption of the room installed AHU(Air Handling Unit) system; estimating energy consumption of the room installed HRV system. Therefore, comparison of two methods was proceeded to evaluate energy performance of each method. Result: As the result of comparison between rooms installed AHU and HRV, the experiment showed that energy consumption of the room installed HRV system is about 22% less than the room of AHU system. This conclusion is considered because the room installed HRV system have maintained temperature well at set point temperature $26^{\circ}C$.

Actual Conditions of Voltage and Current Harmonics on Low-voltage Power Systems Supplying Various Facilities (각종 시설물 전원계통의 전압과 전류고조파 실태)

  • Lee, Bok-Hee;Baek, Young-Hwan
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.4
    • /
    • pp.62-70
    • /
    • 2005
  • This paper presents the actual conditions and reform measures of voltage and current harmonics being made in low-voltage power systems supplying various loads. The measurements were carried out at the secondary output terminals of 22.9[kV]/380[V]220[V] customer's transformers, and the results were discussed on the basis of the comparison with IEEE and IEC harmonics control standards. The voltage THDs of the power systems employed in this survey were less than $5[\%]$ that is considered to be acceptable. On the contrary, the current distortions were significantly greater than the voltage distortions, and the current THDs were distributed over the wide-range from 15.7 to $60.4[\%]$. In particular, the current distortion on the low voltage power lines of office buildings in which many PC and fluorescent lamps are used is remarkably more serious than that of factory facilities. As a result, the voltage distortion factors are observed within the range of its allowable level or less than the limits, but the current distortion factors are significantly greater than the limits of IEEE and IEC standards.

Ambient Vibration Testing and System Identification for Tall Buildings (고층건물의 자연 진동실험 및 시스템판별)

  • Cho, Soon-Ho
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.16 no.3
    • /
    • pp.23-33
    • /
    • 2012
  • Dynamic response measurements from natural excitation were carried out for three 18-story office buildings to determine their inherent properties. The beam-column frame system was adopted as a typical structural form, but a core wall was added to resist the lateral force more effectively, resulting in a mixed configuration. To extract modal parameters such as natural frequencies, mode shapes and damping ratios from a series of vibration records at each floor, the most advanced operational system identification methods based on frequency- and time-domain like FDD, pLSCF and SSI were applied. Extracted frequencies and mode shapes from the different identification methods showed a greater consistency for three buildings, however the three lower frequencies extracted were 1.2 to 1.7 times as stiff as those obtained using the initial FE models. Comparing the extracted fundamental periods with those estimated from the code equations and FE analysis, the FE analysis results showed the most flexible behavior, and the most simple equation that considers the building height as the only parameter correlated fairly well with test results. It is recognized that such a discrepancy arises from the fact that the present tests exclude the stiffness decreasing factors like concrete cracking, while the FE models ignore the stiffness increasing factors, such as the contribution of non-structural elements and the actual material properties used.

A Study on the Harmonic Characteristics of GHP Cooling/Heating Load in an Institutional Building (교육용 건물의 GHP 냉/난방 부하의 고조파 특성에 관한 연구)

  • Kim, Kyung-Chul;Oh, Kyung-Hoon;Lee, Kyu-Jin
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.4
    • /
    • pp.29-38
    • /
    • 2009
  • The GHP(Gas Heat Pump) is an efficient cooling;11eating system in which a compressor is driven by a gas engine and is brodening its application to the facilities such as schools and office buildings. It is difficult to control the GHP system because of slow response, big time constant and time variant system. These nonlinear loads generate harmonic currents and create distortions on the sinusoidal voltage of the power system Harmonic field measurements have shown that the harmonic contents of a waveform varies with time. A cumulative probability approach is the most commonly used method to solve time varying harmonics. This paper provides an in depth analysis on harmonics field measurement of the GHP loads, harmonic assessment by me 61000-3-2, and harmonic simulation and harmonic filter application using EDSA program for the case study system.

Simulation platform for living environment to ensure quality life (쾌적한 생활 설계를 위한 주거 및 사무실 시뮬레이터개발)

  • Park, Se-Jin;Kim, Chul-Jung;Kim, Si-Kyung;Mazumder, Mohammad Mynuddin Gani
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.8 no.4
    • /
    • pp.853-860
    • /
    • 2007
  • In this modern era, human beings lead their life in complex environment where there are lots of parameters such as temperature, light, smell, sound, visual stimulus etc. that play important role for quality life. These parameters affect physical and mental behavior of a human being immensely. To ensure quality life the demand for quality products is always associated with human emotion and sensibility. Due to human sensibility and emotion involvement with quality life, the design stages of any kind of product must include some certain features related with emotion and sensibility. The cues for optimizing artificial environment are the physiological responses of human in that environment. The conventional approach of environmental physiology is to measure the relationship between environmental physical parameters and human psychological parameters under artificial conditions. Using that approach we tried to design an artificial environment for our daily lives and activities associated with both physiological and psychological behavior. We developed the technique to present the mock environment and software to measure and evaluate sensibility physiologically or psychologically and a simulator to measure and evaluate sensibility that can be utilized for large scale industrial production and design of environment. Simulator to measure and analyze human sensibility (SMAS) was constructed, which was utilized to estimate human sensibility and to simulate living and office environment.

  • PDF

Recommended Practice for Demand Factor using Regression Analysis Theory depending on Power Consumption Characteristics in Commercial Buildings (업무용빌딩의 전력소비 특성을 고려한 회귀분석이론을 이용한 수용률 기준 설정)

  • Kim, Se-Dong;Shin, Hyo-Seop;Kim, Soo-Gil;Oh, Kie-Bong
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.217-222
    • /
    • 2004
  • 고도 정보화 사회의 진전으로 전기에너지의 소비는 급격히 증가하고 있다. 특히 업무용 빌딩과 같은 전력다소비 건물에서는 전력의 효율적 이용에 의한 에너지절감은 물론 설계 단계에서의 합리적인 전기설비 설계가 요청되고 있다. 현재 우리나라의 기후 특성과 전력소비 특성을 고려한 합리적인 전기설비 설계를 위한 기초 자료가 매우 미흡한 실정이다. 본 연구에서는 합리적인 수용률 기준을 설정하기 위하여 사무소용 빌딩의 전력 소비 특성을 조사 분석하였고, 아울러 전기설비설계사무소에서 적용하고 있는 수용률을 조사 분석하였다. 조사된 자료 전체의 특징과 중심적인 경향을 알아내기 위해서 평균값, 중앙값, 표준편차, 최대 값, 최소 값, 회귀모형식, 최소제곱 평균오차 등의 확률 통계적 파라미터들을 수용률 기준 설정을 위한 특징 파라미터로 선택하였다. 그리고, 데이터의 신뢰성을 비교 분석하기 위하여 선형적인 방법과 비선형적인 방법으로 그 경향을 추정하여 곡선으로 나타내었다. 이러한 방법에 의하여 얻어진 분석 자료를 이용하여 적정 변압기 용량 설정을 위하여 데이터베이스화하였고, 변전설비용량의 합리적인 설계를 위하여 수용률 기준 적용시에 필요한 자료로 활용할 수 있으리라 사료된다.

  • PDF

A Study of the Friction Factor Unit Considering the Cost of Energy (에너지비용변화에 따른 경제적 단위마찰저항 값에 대한 고찰)

  • Shin, Dong-Shin;Kim, A-In;Lee, Byung-Hyun;Jung, Hyueong-Mok;Lee, Sung-Goo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.28 no.1
    • /
    • pp.29-34
    • /
    • 2016
  • The friction factor unit was studied to find a more economic alternative compared to the conventional 30 mmAq/m. The pipe and pump for cooling water piping used in a failing were selected, and the friction factor unit was changed to calculate the pipe diameter and the brake shaft power. Based on current electric charges, After the brake shaft power was converted into operational costs based on current electric charges, then an economic analysis was conducted considering that incorporated the initial installation costs and operational costs for the pump. We found that the friction factor unit when using 20 mmAq/m is more economical than that with 30 mmAq/m, if the piping is used for more than 4 years. The small friction factor unit is desirable when the piping is used for quite a long period of time, and the selection of a more economic friction factor unit should considering the period of usage will be important.

A Study on the Urban Freight TSM Techniques (도시 화물차량 TSM 기법에 관한 연구)

  • 김건영
    • Proceedings of the KOR-KST Conference
    • /
    • 1998.10a
    • /
    • pp.488-495
    • /
    • 1998
  • 대도시지역은 인구와 경제활동의 밀집도가 매우 높은 지역이나 계속되는 교통혼잡의 가중에의한 신속한 물자이동의 제약과 화물작업을 위한 공간의 부족 등으로 인하여 원활한 수송활동과 물류활동을 제한하는 장애요인들이 화물의 이동에 비하여 많은 실정이다. 도시가 존속하고 생산활동, 소비활동을 하기 위해서는 원자재, 에너지, 제품 등이 도시내·외를 통해 생산부문간과 개인·집단간에 원활한 수송이 이루어져야 한다. 하지만, 서울과 같은 대도시는 우리 나라 전체 경제에 미치는 영향이 매우 큼에도 불구하고 급속하게 증가하는 승용차 위주로 교통소통, 교통체계개선(TSM), 도로망 구축 등의 정책이 시행되어 왔다. 대규모 물류이동이 필수적인 서울의 남대문시장, 동대문시장, 용산전자상가 등 오래전부터 형성되어 온 도심상가지역은 굳이 언급하지 않더라도 서울 근교 신도시에 점차 확산되고 있는 대형 할인매장 등의 유통업무지구, 대형 사무용 건물 등에 원활하고 적시의 수송지원을 위해서는 체계적이고 합리적인 물류체계와 화물시스템 못지 않게 그에 따른 도로의 기하하적 구조나 화물차량을 고려한 신호체계 등이 필요하다. 따라서, 본 연구에서는 일반적인 도시 TSM기법 중에서도 화물차량 위주의 TSM기법에 중점을 두고 대도시에 적용 가능한 도로상의 화물차량 소통기법을 연구하여 그 적용성과 기대효과를 살펴보는데 그 목적이 있다. 본 연구는 크게 도시외곽을 경유하는 화물차량에 관한 도시외곽 화물 TSM 기법과 도시내 통과차량 소통기법, 주·정차 및 조업차량관리기법의도시내 화물TSM 기법으로 구성되어 있다. 도시외곽 화물 TSM 기법의 주내용은 신호체계 개선과 도로의 기하구조 개선 등이며, 도시내 화물 TSM 기법은 화물차량의 도시내 교통소통 기법과 화물차량의 주·정차 관리 및 조업차량 관리에 대한 연구를 수행한다. 대부분의 TSM 개선방안의 시행주체가 경찰청과 시이므로 본 연구의 결과는 도시의 원활한 화물교통소통을 위하여 적용가능할 것으로 예상된다.

  • PDF

Spatial Clustering Analysis based on Text Mining of Location-Based Social Media Data (위치기반 소셜 미디어 데이터의 텍스트 마이닝 기반 공간적 클러스터링 분석 연구)

  • Park, Woo Jin;Yu, Ki Yun
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.23 no.2
    • /
    • pp.89-96
    • /
    • 2015
  • Location-based social media data have high potential to be used in various area such as big data, location based services and so on. In this study, we applied a series of analysis methodology to figure out how the important keywords in location-based social media are spatially distributed by analyzing text information. For this purpose, we collected tweet data with geo-tag in Gangnam district and its environs in Seoul for a month of August 2013. From this tweet data, principle keywords are extracted. Among these, keywords of three categories such as food, entertainment and work and study are selected and classified by category. The spatial clustering is conducted to the tweet data which contains keywords in each category. Clusters of each category are compared with buildings and benchmark POIs in the same position. As a result of comparison, clusters of food category showed high consistency with commercial areas of large scale. Clusters of entertainment category corresponded with theaters and sports complex. Clusters of work and study showed high consistency with areas where private institutes and office buildings are concentrated.