• Title/Summary/Keyword: 사무소 건축

Search Result 1,321, Processing Time 0.028 seconds

Education Efficiency Analysis of Architectural Design Firms Using a Combined AHP and DEA Model (DEA/AHP 결합모형을 이용한 건축 설계사무소의 교육효율성 분석)

  • Seo, Hee-Chang;Oh, Jung-Keun;Kim, Jae-Jun
    • Korean Journal of Construction Engineering and Management
    • /
    • v.14 no.3
    • /
    • pp.78-87
    • /
    • 2013
  • The modern society has been drastically changed from the industrial economic society to the knowledge based society, to catch up with the knowledge and the change of technology required for the modern people, the people can not live in the modern society without the continued study or education. In case of architectural design firm, it is concentrating on the productivity of enterprise by cultivating the working level through the self education focused on the improvement of inner capacity. In connection with this, the efficiency of enterprises are analyzed by carrying out the Data Envelopment Analysis(DEA) utilizing the financial ratio index in the various field of industries recently, the analysis study for the efficiency utilizing DEA is increased in the construction industries as well. However, in case of construction industries, the study focused on the efficiency of administration only has been progressed, it is the real situation that the approach for the analysis of education efficiency of each enterprise is very insufficient. Therefore, this study analyzed the education efficiency of architectural design firm after the selection of input and output variables by utilizing the DEA model and utilizing the AHP analysis technique by deducting the variables through the preceding study in relation to the education efficiency and the interview with the specialists.

A Study on the Ward Module according to the External Design of the Hospital (병원 외주부 디자인에 따른 병실모듈 연구)

  • Lee, Hyunjin;Park, Wonbae
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.27 no.3
    • /
    • pp.71-78
    • /
    • 2021
  • Purpose: It is important to plan the ward module at a time when the size of beds, the floor area, and the construction budget are all set prior to the hospital design. In this context this study aims (1) to derive various factors affecting the ward module, and (2) to analyze the appropriate room module according to the type. Methods: Design factors related to hospital modules are derived through precedential studies, and the types of ward elevation are classified by reviewing the drawings of 18 case hospitals. And the detailed dimensions and area of the derived elements are analyzed. Results: The X-axis modules of the ward are switched to long span structural columns of 9.9 m, 12.6 m and 13.2 m, but the ward modules still represent 6.6 m. The Y-axis module of the ward shows a dimension of 9 to 9.9m in the process of changing a multi-person room into a four-person room. Type A of curtain wall with columns located on the wall of the room and type B of curtain wall located in the center of the room are analyzed due to their variations. The square window type, which forms the elevation of the square window by exposing the columns to the elevation, and the outframe type, which protrudes from the structural columns and beams, have elevation designs limited. There are, however, no obstacles to the interior space of the hospital room, so the wall composition and furniture arrangement are expected to be free. The ward area of Curtain Wall Type A, which can secure an effective area of 5.9m*5.0m, are 52.1m2. The Curtain Wall Type A, Square window type, and the outframe type are 49.8m2. Implications: As part of the hospital standard module plan for economical and reasonable hospital building planning, a type was proposed in this study in conjunction with the external design. It is hoped that it be a base for standard module research linked together to the Central Treatment department, Outpatient department and underground parking lot.

Energy Efficient Lighting Control Facilities Related to Daylight Levels (주광(晝光) 대등형 가변조명(可變照明) 제어설비의 적용 및 통합성능)

  • Kim, Jeong-Tai;Kim, Gon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.2
    • /
    • pp.8-15
    • /
    • 2006
  • To reduce costs and address other practical concern related to architectural lighting, we have been involved in various aspects of advanced daylighting design and control. If we look toward future building trends, we see that the advanced has already successfully deployed such complex lighting control systems. This paper takes a broad view of what advanced manufacturers have done to develop energy efficient lighting control technologies such as sensors, lumen maintenance, time of day scheduling, peak demand reduction and so forth. First of all strategies, daylighting controls would also need to be commissioned to respond to the specific daylighting signature of the zone. To translate the daylight in term of the amount of energy savings, an electric lighting system is designed and automatic on-off control system integrated with the contribution of daylighting has been applied to the operating of the artificial lighting. The lighting analysis program, Lumen-Micro predicts the optimal layout of conventional fluorescent and incandescent lighting fixtures to meet the designed lighting level and calculates unit power density, which translates the demanded amount of lighting energy.

Seismic Performance Assessment of a Composite Modular System Considering Stiffness of Connections (접합부 강성을 고려한 합성 모듈러 시스템의 내진 성능평가)

  • Choi, Young-Hoo;Lee, Ho-Chan;Kim, Jin-Koo
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.23 no.1
    • /
    • pp.9-18
    • /
    • 2019
  • Modular system can be divided into two types based on the methods of resisting load. The one is the open-sided modular system composed of beams and columns. The other is the enclosed modular system composed of panels and studs. Of the Modular systems, the use of open-sided modular system is limited because it consists of closed member sections. In order to solve this problem, Choi et al.(2017) proposed a composite modular system with folded steel members filled with concrete. However, it was assumed in the previous study that the connections between modules are composed of rigid joint. Therefore it didn't identify the effect of connection behavior in structure. This study used finite element analysis to calculate stiffness of the connections in the proposed modular system. The linearization method presented in FEMA 440 is used for seismic performance assessment of structures, considering the connection stiffness computed in this study. The result of analysis shows that the capacity and story drift ratio obtained in the model considering stiffness of connection are less than those in the model not considering connection stiffness. Based on this observation, it is concluded that the stiffness of connection has a considerable effect on structural behavior.

A Analysis of Generated Construction Waste and Dismantlement Method by Field Investigation (분별해체 현장조사에 의한 건설폐기물 발생량 및 공정 분석)

  • Lee, Jong-Chan;Song, Tae-Hyeob
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.4 no.1
    • /
    • pp.101-109
    • /
    • 2009
  • This CW(Construction wastes) are increasing as construction industry is growing, so many countries make efforts to recycle CW. Korea also made a stipulation for recycling CW. But the main content of this stipulation is for using recycled aggregates. Advanced countries try to increase reuse rate of not only recycled aggregate but also other kinds of wastes. So they are adopting SDM(separating dismantlement) method and we are also planning to make the system for SDM. This study is about SDM analysis through construction field investigation and difference analysis between SDM and UDM comparing predictive amount by UDM with real generated amount by SDM. First, the generated amount of construction wastes by SDM is more than estimated amount by UDM, and mixed waste was specially reduced more than UDM. The warehouse is easier than the office building to applicate SDM. But still there is no manual for SDM in the site, so establishment of SDM is demanded.

  • PDF

A Basic Study on BIM Library Business Model based on Building Material Information System (건축 자재 정보 시스템기반 BIM 라이브러리 비즈니스 모델에 관한 기초 연구)

  • Lee, Goon-Jae
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.4
    • /
    • pp.43-49
    • /
    • 2017
  • In recent years, the use of BIM in domestic construction has been increasing, but it is used mainly for internal and external visualization rather than for BIM design including drawings. For this reason, several studies have highlighted the lack of libraries and economic problems for BIM design. In other words, for the most economically small domestic design offices, activating the BIM design is a negative factor because it is difficult to invest the necessary manpower and cost to produce and use the required BIM library. The BIM design can be more applicable if the library can be supplied economically, easily, and quickly. In this study, BIM library business model and consideration factors that can provide BIM library service economically, easily, and quickly by considering the existing building material selection task and BIM library are presented. The proposed business model will increase the number of suppliers of BIM libraries, which are lacking in Korea, and will enable an effective BIM design at low cost and effort. If a service that reflects the business model proposed in this study is made, an integrated database that can consistently share information in the design, construction, and maintenance stages will be constructed. This can monitor the changes in material and equipment information during the life cycle of the building. The database can be used to monitor any changes in material and equipment information throughout the life cycle of a building, so that it can be used as historical data for effective design and maintenance as well as for material and equipment upgrades.

An Analysis of Operation Structure and Contribution of Civilian Expert Program for Landscape Architects focusing on Local Governments (지방자치단체의 조경분야 민간전문가 제도 운영현황 및 문제점 분석)

  • Park, Jeongeun;Kim, Youngmin
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.50 no.1
    • /
    • pp.78-90
    • /
    • 2022
  • This research analyzed the status and problems of civilian expert programs for landscape architects to suggest alternatives to improve the current system. Literature research focused on the issues of the legal definition of civilian experts, the background of the program, and related regulations. Based on the understanding of the legal system, the research analyzed the operation status, structure, roles of the civilian expert program of local governments where landscape architects were delegated as civilian experts. Currently, 50 local governments are running the civilian expert program, and landscape architects are working as civilian experts in 11 institutions. The majority of landscape architects are working as MA or general architects. Only SMG runs an independent general landscape architect program. Based on the literature research and interviews with 16 experts, the research examined four main issues related to the program. First, the legal system issues of the civilian expert programs are related to the regulations assuming architects as experts. Revising the current legal system is a better alternative than promulgating a new law for landscape architects. Second, the compensation issue was a main problem related to operation. Securing a sufficient budget and more effective administration is required to solve the problem. Third, related to the role, the tasks being limited to consultation were regarded as the main problem. Although landscape architects wanted more opportunities to directly participate in the project's design, the fairness of the public project contracting system needed to be considered. Fourth, the competence issue is related to the number of available landscape architects. This issue can be solved by expanding the pool of civilian experts to adjacent disciplines, such as public design or landscape management.

An application to HVAC control system based on occupants' thermal response in office buildings (공조제어 적용을 위한 재실자 온열반응 데이터의 유효성 분석에 관한 연구)

  • Han, Hyesim;Kim, Jonghun;Jeong, Hakgeun;Jang, Cheol-Yong
    • KIEAE Journal
    • /
    • v.14 no.4
    • /
    • pp.111-117
    • /
    • 2014
  • In South Korea, the government has recently enforced regulations associated with buildings. Temperature restriction in indoor environment is one of the common ways of energy reduction in order not to dissipate heating and cooling energy; however the people who are in restricted temperature feels uncomfortable. Furthermore, occupants cannot feel the same thermal sensation even they are in the same place. For the reason, occupants should express their thermal sensation and HVAC system should be able to apply their demand. It is proved by an adaptive principle. The adaptive model means that people react in ways which tend to restore their comfort, when change occurs such as to produce discomfort. In order to design HVAC control strategies based on adaptive model, we designated an existing office building as a reference building to gather data from actual field. Furthermore, we gathered occupants' thermal sensation and clothing insulation in real-time. We filtered the data with Kalman's filter method. The data was reasonable when there is an alarm messages for asking questionnaire. The response ratio were different in occupants' thermal condition. In conclusion, the filtered occupants' thermal sensation can be used as a real time HVAC control and input value of HVAC control.

A Study on Analysis for Energy Demand of the Heating, Cooling and Lighting in Office Building with Transparent Thin-film a-Si BIPV Window (투광형 박막 BIPV 창호 적용에 따른 냉난방 및 조명 부하 저감에 관한 연구)

  • Yoon, Jong-Ho;An, Young-Sub;Park, Jang-Woo;Kim, Bit-Na
    • KIEAE Journal
    • /
    • v.13 no.3
    • /
    • pp.91-96
    • /
    • 2013
  • The purpose of this study was to analyze the annual energy demand including heating, cooling and lighting according to kind of windows with transparent thin-film a-Si Building Integrated Photovoltaic(a-Si BIPV) for office building. The analysis results of the annual energy demand indicated that the a-si BIPV window was reduced by 8.4% than the clear gazing window. The base model A was combinate with a-Si BIPV window area of 67% and clear window area of 33% among the total exterior area. The model B is to be applied with low-e clear glass instead of clear glass of the base model A. The model B was reduced to annual energy demand of 1% more than the model A. Therefore, By using a-si BIPV solar module, the cooling energy demand can be reduced by 53%(3.4MWh) and the heating energy demand can be increase by 58%(2.4MWh) than clear glazing window in office building. Also, Model C applied to the high efficient lighting device to the model B was reduced to annual energy demand of 14.4% more than the Model D applied to the high efficient lighting device to the model A. The Model E applied with daylight dimming control system to the Model C was reduced to annual energy demand of 5.9% more than Model C.

Analysis characteristics of surface runoff rate of Nae-seong catchment at Nakdong River (낙동강 내성천유역의 표면유출비 특성분석)

  • Chang, Hyung Joon;Lee, Hyo Sang;Min, Byung Yun;Jo, Guk-Hui;Lee, Mu-Gyeong
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2015.05a
    • /
    • pp.440-440
    • /
    • 2015
  • 최근 급증하는 기후변화 영향으로 인한 자연재해의 위험이 증대되고 있다. 이러한 자연재해 중 가뭄은 그 빈도수나 피해의 규모가 홍수보다 작아 관련된 연구가 제한적이므로 유역의 특성을 반영한 장 단기 유출특성의 면밀한 검토가 요구되며, 향후 이를 반영한 홍수유출모형의 개발이 필요하다. 본 연구에서는 유역 수자원산정의 기초연구로서 낙동강 내성천 유역을 대상으로 유역의 유출수문자료를 구축하고 장기기저흐름지수(BFI: Base Flow Index), 표면유출지수(1-Base Flow Index)를 산정하여 유역의 유출특성을 분석하였다. 내성천유역은 낙동강 상류유역으로 본류길이는 110.69km, 유역면적은 $1,815.28km^2$이며, 분수계의 능선부가 대체로 1,000m이상의 고도를 나타내고, 유역분지의 평균 해발고도는 318.2m이다. 또한 영주댐이 검설 중에 있으며, 향후 댐 건설이 수자원에 끼치는 영향등을 분석 할 수 있는 유역이다. 본 연구에서는 내성천 유역을 분석하기 위해서 8개의 수위관측지점을 선정한 후, 2001년부터 2012년 기간의 일 유량자료를 바탕으로 유출비를 산정하였다. 내성천 8개 소유역의 유역 장기유출비를 분석한 결과 기저흐름지수는 0.24~0.47, 표면유출지수는 0.53~0.76의 분포를 나타내었다. 표면유출비는 미호(0.76), 월호(0.53), 점촌(0.71)유역을 제외한 5개 유역에서 0.62~0.65의 분포를 나타내었으므로 낙동강 상류인 내성천유역의 표면유출비로 0.63을 제시할 수 있을 것으로 판단된다. 향후 다수의 낙동강유역을 추가분석하여, 낙동강유역의 고유 유출특성을 제시 할 수 있을 것으로 기대된다.

  • PDF