• Title/Summary/Keyword: 사각단면

Search Result 108, Processing Time 0.029 seconds

Natural Circulation Flow Investigation in a Rectangular Channel (사각 단면 채널에서의 자연순환 유동에 관한 연구)

  • Ha, Kwang-Soon;Kim, Jae-Cheol;Park, Rae-Joon;Kim, Sang-Baik;Hong, Seong-Wan
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.3086-3091
    • /
    • 2007
  • When a molten corium is relocated in a lower head of a reactor vessel, the ERVC (External Reactor Vessel Cooling) system is actuated as coolant is supplied into a reactor cavity to remove a decay heat from the molten corium during a severe accident. To achieve this severe accident mitigation strategy, the two-phase natural circulation flow in the annular gap between the external reactor vessel and the insulation should be formed sufficiently by designing the coolant inlet/outlet area and gap size adequately on the insulation device. For this reason, one-dimensional natural circulation flow tests were conducted to estimate the natural circulation flow under the ERVC condition of APR1400. The experimental facility is one-dimensional and scaled-down as the half height and 1/238 rectangular channel area of the APR1400 reactor vessel. As the water inlet area increased, the natural circulation mass flow rate asymptotically increased, that is, it converged at a specific value. And the circulation mass flow rate also increased as the outlet area, injected air flow rate, and outlet height increased. But the circulation mass flow rate was not changed along with the external water level variation if the water level was higher than the outlet height.

  • PDF

Low Loss Plastic Optical Fiber Coupler Incorporating a Polymer Tapering Waveguide Region (폴리머 테이퍼링 도파로 영역이 있는 저 손실 플라스틱 광섬유 커플러)

  • Kim, Kwang-Taek;Min, Seong-Hwan;Yun, Jung-Hyun
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.7 no.4
    • /
    • pp.867-871
    • /
    • 2012
  • In this paper, we proposed and demonstrated a low loss $1{\times}4$ type plastic optical fiber(POF) coupler incorporating a polymer tapering waveguide region. To avoid leakage loss at the interfaces between the POF and the polymer waveguide, we employed two POF transition regions, in which the cross section of the POF is adiabatically converted from a circular to a rectangular shape without change of its cross-section area. The device was fabricated based on a injection mold made of a silicon rubber. The fabricated POF coupler showed 1.33 dB of excess loss and 2.2 dB of flatness.

Prediction of Non-linear Behavior of Flexible Matrix Composites (유연수지를 기지재료로 하는 복합재료의 비선형거동 예측)

  • 서영욱;우경식
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.34 no.10
    • /
    • pp.24-31
    • /
    • 2006
  • In this paper, mechanical behavior of unidirectional composites with flexible matrix was predicted by geometrical non-linear finite element analysis. Two typical idealized unit cells of square and hexagonal fiber arrays were modeled and these were subjected to different loadings. The stress-strain behavior of composites was predicted from which the effective properties were calculated. The hyperelasticity of polyurethane matrix was considered using Mooney-Rivlin model. In result, the stress-strain behavior of flexible composites shows non-linearity, especially it is remarkable under transverse normal and shear loading conditions. In this cases, there are great difference between square and hexagonal fiber array models.

Three-Dimensional Flow Analysis around Rolling Stock with Square Cross Section Using Low Re ${\kappa}-{\epsilon}$ (사각 단면을 갖는 철도차량 주위의 3차원 유동해석)

  • Jang, Yong-Jun
    • Journal of the Korean Society for Railway
    • /
    • v.9 no.6 s.37
    • /
    • pp.772-777
    • /
    • 2006
  • Three-dimensional numerical study is performed for the flow analysis around the rolling stock with square cross section (Mugungwha train model). The height (H) of rolling stock is considered as the characteristic length and the total length of rolling stock is 40 which correspond to 1/2 unit of rolling stock. The gap between the surface and rolling stock is 0.17H which is average value. The relative velocity between the surface and rolling stock is assumed to be zero and Re=10,000 based on the characteristic length. Low Re ${\kappa}-{\epsilon}$[15] is employed for the calculation of turbulence which resolve all the way to the solid surface (laminar sub-layer). Large flow separation occurred at the front head of train and a pair of vortex is generated on both top and side of rolling stock. The behavior of vortices on the top of the rolling stock is believed to affect the performance of the pantograph which should be intensively investigated. The difference between the high pressure in the front stagnation region of train and the low pressure in the rear separated region causes a large pressure drag. A large pair or vortex are generated in the rear of train and the size of vortex is increased more than the size of cross section of train.

Plate Type New Distributor Development for Hydraulic Motors and Pumps (유압모터 및 펌프용 판 형태의 새로운 분배기 개발)

  • Jin, Seong-Mu;Kim, Hyeong-Ui
    • 한국기계연구소 소보
    • /
    • s.18
    • /
    • pp.75-85
    • /
    • 1988
  • The distributor for hydraulic pumps or motors, particularly radial piston motors, include rotary member which has equally both surface shape for dynamic balance and two fixed members, located in both side of rotary member, which have equal surface shape for dynamic balance and circular ring which use to retain predetermined clearance between two fixed members. Rotary member must have valve part for flow-distribution and can have hydrostatic bearing for excellently dynamic balance. At least two annular steps located on said pressure plate which use in compensation of bolt expansion.

  • PDF

A Study on storage caculation of Ungauged reservoir (미계측 저수지의 저수량 산정에 관한 연구)

  • Jang, Moon Yup;Song, Ju Il;Kim, Han Tae
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2018.05a
    • /
    • pp.400-400
    • /
    • 2018
  • 우리나라는 현재 17,310개소(2015년)의 저수지가 존재하고 있으며, 지자체가 13,916개소, 한국농어촌공사가 3,394개소를 관리하고 있다. 이중 30만㎥ 이상인 저수지가 전체 저수량의 대부분을 차지하기 때문에 1,500개소에 대해서는 저수위 등이 계측되고 있고, 그 외에 소규모 수리시설물의 경우 유역면적, 만수면적, 총저수량, 유효저수용량, 제원 등 현황만 관리되고 있다. 그러나 미계측 되는 10만$m^3$ 미만 소규모 수리시설물(15,175개소)의 총저수량은 약 2.5억$m^3$으로 전체의 4.2%에 불과 하지만, 수혜면적 32.9만ha로 전체의 약 65.9%를 차지하고 있어 소규모 수리시설물의 저수량을 파악할 필요가 있다. 미계측 수리시설물의 저수량 측정은 수문계측기를 이용하는 방법이 가장 정확한 방법이나 비용이 과다하게 소요되는 측면이 있어 전국 저수지에 설치하는 것은 현실적으로 불가능하기에 미계측 수리시설물의 저수면적-저수량 관계식을 개발하여 저수량을 도출하고자 한다. 미계측 수리시설물 저수량 산정은 저수지의 지리적 위치, 저수지의 형태(삼각, 사각, 원형 등), 총 저수량 등에 따라 단면 형태를 추정하여 구분한다. 저수면적-저수량 관계식을 형태별로 제시하여 실제 계측이 이루어지고 있는 자료와의 비교 검토를 통해 관계식을 검증하고자 한다.

  • PDF

A Study on the Installation of the Optimized Collapse Risk Detection Monitoring System for Small-Scale Private Buildings (소규모 민간 건축물을 위한 최적의 붕괴 위험 감지 모니터링 시스템 설치 방안 연구)

  • Heejae Kim;Geunyoung Kim
    • Journal of the Society of Disaster Information
    • /
    • v.20 no.1
    • /
    • pp.147-155
    • /
    • 2024
  • Purpose: The purpose of this study is to analyze the danger signs of buildings and present a plan to install a building monitoring system to develop measurement technology for small private buildings in the blind spot of disaster safety. Method: The cause of building risk behavior, components of monitoring measuring equipment, location of measuring equipment installation, management plan, etc. are presented. Result: Measuring instruments essentially include acceleration sensors, tilt sensors, gyro sensors, GPS, etc. The measuring instrument should take into account the height and cross-sectional area of the pillar. Conclusion: The results of this study can strengthen disaster safety capabilities in preparation for disasters arising from building collapses that may occur in small private buildings.

Numerical Simulation of Convection-dominated Flow Using SU/PG Scheme (SU/PG 기법을 이용한 이송이 지배적인 흐름 수치모의)

  • Song, Chang Geun;Seo, Il Won
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.32 no.3B
    • /
    • pp.175-183
    • /
    • 2012
  • In this study, Galerkin scheme and SU/PG scheme of Petrov-Galerkin family were applied to the shallow water equations and a finite element model for shallow water flow was developed. Numerical simulations were conducted in several flumes with convection-dominated flow condition. Flow simulation of channel with slender structure in the water course revealed that Galerkin and SU/PG schemes showed similar results under very low Fr number and Re number condition. However, when the Fr number increased up to 1.58, Galerkin scheme did not converge while SU/PG scheme produced stable solutions after 5 iterations by Newton-Raphson method. For the transcritical flow simulation in diverging channel, the present model predicted the hydraulic jump accurately in terms of the jump location, the depth slope, and the flow depth after jump, and the numerical results showed good agreements with the hydraulic experiments carried out by Khalifa(1980). In the oblique hydraulic jump simulation, in which convection-dominated supercritical flow (Fr=2.74) evolves, Galerkin scheme blew up just after the first iteration of the initial time step. However, SU/PG scheme captured the boundary of oblique hydraulic jump accurately without numerical oscillation. The maximum errors quantified with exact solutions were less than 0.2% in water depth and velocity calculations, and thereby SU/PG scheme predicted the oblique hydraulic jump phenomena more accurately compared with the previous studies (Levin et al., 2006; Ricchiuto et al., 2007).

Transmitted Noise Reduction Performance of Piezoelectric Single Panel through Piezo-damping (압전감쇠를 통한 압전단일패널의 전달 소음저감성능)

  • 이중근;김재환;김기선;이형식
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.2 no.2
    • /
    • pp.49-56
    • /
    • 2001
  • The possibility of a noise reduction of piezoelectric single Panels is experimentally studied. Piezoelectric single panel is basically a plate structure on which piezoelectric patch with shunt circuit is mounted. The use of piezoelectric shunt damping can reduce the transmission at resonance frequencies of the panel structure. Piezo-damping is implemented by using a newly proposed tuning method. This method is based on electrical impedance model and maximizing the dissipated energy at the shunt circuit. By measuring the electrical impedance at the piezoelectric patch bonded on a structure, an equivalent electrical model is constructed near the system resonance frequency. Resonant shunt circuit for piezoelectric shunt damping is composed of register and inductor in series, and they are determined by maximizing the dissipated energy throughout the circuit. The transmitted noise reduction performance of single Panel is tested on an acoustic tunnel. The tunnel is a tube with a square cross section and a loud speaker is mounted at one side of the tube as a sound source. Panels are mounted in the middle of the tunnel and the transmitted sound pressure across Panels is measured. By enabling the piezoelectric shunt damping noise reduction is achieved at the resonance frequencies as well. Piezoelectric single panel with piezoelectric shunt damping is a promising technology for noise reduction in a broadband frequency.

  • PDF

Broadband Transmission Noise Reduction Performance of Smart Panels Featuring Piezoelectric Shunt Damping and Passive Characteristics (압전감쇠와 수동적 특성을 갖는 압전지능패널의 광대역 전달 소음저감성능)

  • 이중근;김재환
    • The Journal of the Acoustical Society of Korea
    • /
    • v.21 no.2
    • /
    • pp.150-159
    • /
    • 2002
  • The possibility of a broadband noise reduction of piezoelectric smart panels is experimentally studied. Piezoelectric smart panel is basically a plate structure on which piezoelectric patch with shunt circuits is mounted and sound absorbing material is bonded on the surface of the structure. Sound absorbing materials can absorb the sound transmitted at mid frequency region effectively while the use of piezoelectric shunt damping can reduce the transmission at resonance frequencies of the panel structure. To be able to tune the piezoelectric shunt circuit, the measured electrical impedance model is adopted. Resonant shunt circuit composed of register and inductor in stories is considered and the circuit parameters are determined based on maximizing the dissipated energy through the circuit. The transmitted noise reduction performance of smart panels is investigated using an acoustic tunnel. The tunnel is a square crosses sectional tunnel and a loud speaker is mounted at one side of the tunnel as a sound source. Panels are mounted in the middle of the tunnel and the transmitted sound pressure across the panels is measured. Noise reduction performance of a double smart panel possessing absorbing material and air gap shows a good result at mid frequency region except the first resonance frequency. By enabling the piezoelectric shunt damping, noise reduction is achieved at the resonance frequency as well. Piezoelectric smart panels incorporating passive method and piezoelectric shunt damping are a promising technology for noise reduction in a broadband frequency.