• Title/Summary/Keyword: 비파괴 측정장비

Search Result 59, Processing Time 0.023 seconds

The study of nondestructive method for measuring the acidity of the recent record paper in Hanji by using FT-NIR spectroscopy and Integrating sphere (푸리에 변환 근적외선 분광분석기(FT-NIR)와 적분구를 이용한 근대 한지 기록물의 산성도 비파괴 평가방법에 대한 연구)

  • Shin, Yong-Min;Park, Soung-Be;Kim, Chan-Bong;Lee, Seong-Uk;Cho, Won-Bo;Kim, Hyo-Jin
    • Proceedings of the Korea Technical Association of the Pulp and Paper Industry Conference
    • /
    • 2011.10a
    • /
    • pp.255-269
    • /
    • 2011
  • The purpose of study has to analyze with non destructive method for researching the tool that could be measured with the status of record written on Hanji speedily. Because the original record should be destructed for analyzing with previous method in the case of the paper record, it was to develop the tool based on non destructive method for overcoming such limit. The study was used with FT NIR (Fourier transform NIR) for analyzing the Hanji for being written and preserved. The FT NIR spectrometer that of NIR spectrometer has the better performance of precision and accuracy than dispersive NIR spectrometer was used. Also the wavelength of FT-NIR was measured with 12,500 to 4,000 $cm^{-1}$, and the integrating sphere as diffuse reflectance type was used for analyzing Hanji. The moisture and acidity (pH) of chemical factors as quality evaluated factor of Hanji was studied for the correlation of NIR spectrum. And then The NIR spectrum was pretreated for showing the coefficients of optimum correlation. MSC and First derivative of Savitzky - Golay was used as pretreated method, and the coefficients of optimum correlation were shown by PLSR(Partial least square regression). And the coefficients of optimum correlation were calculated by PLSR(Partial least square regression). The correlation coefficients of acidity had 0.92 on NIR spectra without pretreatment. Also the SEP of acidity was 0.24. And then The NIR spectra with pretreatment would have more good correlation coefficients ($R^2=0.98$) and more good SEP(=019) on acidity. Therefore the data of correlation coefficients ($R^2$) and SEP with pretreatment was shown to be superior. And NIR spectra data of first derivative had best linearity on the correlation coefficients ($R^2=0.99$) and also SEP(=0.45) was superior. Therefore the correlation coefficients and SEP of first derivative had better than those of NIR spectra of no pretreatment. As such result, it was possible to evaluate the record status of Hanji speedily with integrated sphere and NIR analyzer as non destructive method.

  • PDF

Investigation on Impact-echo Testing Method for Rock Specimens (암석 시편의 충격반향(공진주) 시험에 관한 고찰)

  • Cho, Jung-Woo;Lim, Bo-Sung;Cho, Ho-Bum;Jeon, Seok-Won;Ha, Hee-Sang
    • Tunnel and Underground Space
    • /
    • v.17 no.2 s.67
    • /
    • pp.83-89
    • /
    • 2007
  • Impact-echo test is a non-destructive testing method to determine dynamic properties of a material. This presentation introduces the experimental set-up and procedure of the test for rock specimens. In addition, the test results of domestic rocks collected in 5 different areas, a cement mortar and aluminium alloy are presented. The test results include resonance frequencies of P- and S-wave as well as damping ratios of the described 7 different materials. The differences between dynamic and static values of elastic moduli are about 10%, while the dynamic Poisson's ratios are greater than the static Poisson's ratios by at least 0.07. The damping ratio is dependent on the joint density and degree of weathering of a rock specimen.

Application of Amplitude Demodulation to Acquire High-sampling Data of Total Flux Leakage for Tendon Nondestructive Estimation (덴던 비파괴평가를 위한 Total Flux Leakage에서 높은 측정빈도의 데이터를 획득하기 위한 진폭복조의 응용)

  • Joo-Hyung Lee;Imjong Kwahk;Changbin Joh;Ji-Young Choi;Kwang-Yeun Park
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.27 no.2
    • /
    • pp.17-24
    • /
    • 2023
  • A post-processing technique for the measurement signal of a solenoid-type sensor is introduced. The solenoid-type sensor nondestructively evaluates an external tendon of prestressed concrete using the total flux leakage (TFL) method. The TFL solenoid sensor consists of primary and secondary coils. AC electricity, with the shape of a sinusoidal function, is input in the primary coil. The signal proportional to the differential of the input is induced in the secondary coil. Because the amplitude of the induced signal is proportional to the cross-sectional area of the tendon, sectional loss of the tendon caused by ruptures or corrosion can be identified by the induced signal. Therefore, it is important to extract amplitude information from the measurement signal of the TFL sensor. Previously, the amplitude was extracted using local maxima, which is the simplest way to obtain amplitude information. However, because the sampling rate is dramatically decreased by amplitude extraction using the local maxima, the previous method places many restrictions on the direction of TFL sensor development, such as applying additional signal processing and/or artificial intelligence. Meanwhile, the proposed method uses amplitude demodulation to obtain the signal amplitude from the TFL sensor, and the sampling rate of the amplitude information is same to the raw TFL sensor data. The proposed method using amplitude demodulation provides ample freedom for development by eliminating restrictions on the first coil input frequency of the TFL sensor and the speed of applying the sensor to external tension. It also maintains a high measurement sampling rate, providing advantages for utilizing additional signal processing or artificial intelligence. The proposed method was validated through experiments, and the advantages were verified through comparison with the previous method. For example, in this study the amplitudes extracted by amplitude demodulation provided a sampling rate 100 times greater than those of the previous method. There may be differences depending on the given situation and specific equipment settings; however, in most cases, extracting amplitude information using amplitude demodulation yields more satisfactory results than previous methods.

Feasibility of Ultrasonic Inspection for Nuclear Grade Graphite (원자력급 흑연의 산화 정도에 따른 초음파특성 변화 및 초음파탐상의 타당성 연구)

  • Park, Jae-Seok;Yoon, Byung-Sik;Jang, Chang-Heui;Lee, Jong-Po
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.28 no.5
    • /
    • pp.436-442
    • /
    • 2008
  • Graphite material has been recognized as a very competitive candidate for reflector, moderator, and structural material for very high temperature reactor (VHTR). Since VHTR is operated up to $900-950^{\circ}C$, small amount of impurity may accelerate the oxidation and degradation of carbon graphite, which results in increased porosity and lowered fracture toughness. In this study, ultrasonic wave propagation properties were investigated for both as-received and degradated material, and the feasibility of ultrasonic testing (UT) was estimated based on the result of ultrasonic property measurements. The ultrasonic properties of carbon graphite were half, more than 5 times, and 1/3 for velocity, attenuation, and signal-to-noise (S/N) ratio respectively. Degradation reduces the ultrasonic velocity slightly by 100 m/s, however the attenuation is about 2 times of as-receive state. The results of probability of detection (POD) estimation based on S/N ratio for side-drilled-hole (SDHs) of which depths were less than 100 mm were merely affected by oxidation and degradation. This result suggests that UT would be reliable method for nondestructive testing of carbon graphite material of which thickness is not over 100 mm. In accordance with the result produced by commercial automated ultrasonic testing (AUT) system, human error of ultrasonic testing is barely expected for the material of which thickness is not over 80 mm.

An Experimental Study on a Solenoid Eddy Current Sensor to inspect Deteriorations in Overhead Distribution Lines (가공 배전선의 열화를 검출하기 위한 솔레노이드 와전류 센서의 실험적 연구)

  • 김성덕
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.13 no.1
    • /
    • pp.77-85
    • /
    • 1999
  • This paper deals with an experirrental study of a nondestructive testing system using a solenoid eddy currnet sensor to inspect deteriorations in overhead distribution lines, such as broken wires, severe local corrosion or zinc loss. Corrosion rrechanisrn for ACSR and ACSR-OC is discussed and characteristics for a solenoid sensor to insprt the georretrical pararreters of the coil and testing materials impOOance are briefly analyzed. A measurement system having a constant current source, a signal processing unit and a motor driver is impIemented. This instrument has such capabilities as detecting the sensor output and estimating dinHlsions of the testing conductors, continuously. As a result, it was shown that the eddy current sensor with an encircling coil could effectively estimate the diatreter change due to deteriorations in overhead distribution lines. lines.

  • PDF

Evaluation of Effects on Impact Resonance Test for Determining Modulus of Asphalt Concrete (아스팔트 콘크리트 탄성계수 결정을 위한 충격공진시험 영향요소 평가)

  • Kweon, Gi-Chul;Lee, Jae-Hoan
    • International Journal of Highway Engineering
    • /
    • v.9 no.2 s.32
    • /
    • pp.89-99
    • /
    • 2007
  • The stiffness of the asphalt concrete is represented by the complex modulus $E^*$, which is very important properties in the mechanistic design of flexible pavement system. The moduli of asphalt concrete were generally determined by dynamic modulus test. However, the dynamic modulus testing method is too complex, expensive, and time consuming to be applicable on a production basis. The IR(Impact Resonance) method has been shown to be a truly simple nondestructive testing method which produces very repetitive, consistent results. The major object of this study was to estimate of the effects on IR tests for determining modulus of asphalt concrete including impact position, specimen support condition, impact steel ball size and sampling rate. The variations of IR test results with various testing conditions are within ${\pm}2.7%$.

  • PDF

Review of the Current infrared Thermorgraphy Techniques for Detecting Defects in Civil Structures (토목 구조물의 손상 검출을 위한 적외선 열화상 기법의 적용 사례 분석)

  • Sim, Jungi;Zi, Goangseup;Park, Jin-Hyung;Cho, Hyo-Nam;Lee, Jong Seh
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.12 no.3
    • /
    • pp.71-83
    • /
    • 2008
  • In this paper, the basic principle, the application and the limitation of Infrared thermography technique to detect defects in different kinds of concrete structures are reviewed. Considered are voids beneath the concrete surface with experiments, delamination between concrete surface and fiber reinforced polymer sheet, the deterioration of steel bars in reinforced concrete, surface defects in historical buildings, pavements, bridges, and railway track graves. As a result, we conclude that infrared thermography methods are useful for fast detecting defects; however, they are influenced by environmental factors, specially temperature. Therefore it is recommended to use the infrared thermography technique with other NDT equipments to expect better result.

Evaluation of the Nonlinearity Parameter in Unbound Material for Asphalt Concrete Pavement using Field-NDT Equipment (현장 도로평가장비를 이용한 입상재료층의 비선형 재료상수 추정에 관한 연구)

  • Seo, Joo Won;Choi, Jun Seong;Kim, Soo Il
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.28 no.2D
    • /
    • pp.227-234
    • /
    • 2008
  • This study examines which models are more suitable for representing mechanical property of unbound materials to analyze behavior of asphalt pavement structure. Results from FWD (Falling Weight Deflectometer) test were used to apply to nonlinear elastic model. The new method which can deduct material constants of nonlinear elastic model is suggested from FWD test data rather than laboratory resilient modulus ($M_R$) test. It is confirmed that the material constants are within the common range in subbase. Test output from FWD and MDD (Multi-Depth Deflectometer) was used to verify reliability of the model. From the results of verification, this study shows that a non-linear elastic model agrees to MDD test data more than a linear elastic model does.

The Application of a Simplified Pullout Test for High-Strength Concrete (고강도 콘크리트에 대한 간이 인발시험법 적용)

  • Ko, Hune-Bum;Jeon, Doo-Jin;Lee, Min-Jae
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.21 no.5
    • /
    • pp.49-55
    • /
    • 2017
  • In the seventies, a number of researchers carried out experiments on pullout tests with prototype equipment, and the pullout test was certified as a reliable nondestructive testing(NDT) method for determining the strength of concrete. To estimate the strength of high-strength concrete, we propose a simplified pullout test that uses as a break-off bolt a standard 10mm bolt with a groove on the shaft, an insert nut, and a pullout instrument that includes a hydraulic oil pump without a load cell. To verify the advantages of the simplified pullout test(low cost, simplicity, and convenience), four wall specimens were tested with two levels of concrete strength, 30 MPa and 50 MPa, using a simplified pullout tester with a load cell. The pullout load and concrete compressive strength were measured every day until day 7, day 14, day 21 and day 28. It was found that the pullout load was very similar to the compressive strength. Therefore, we have verified that a simplified pullout test can be used to evaluate the in-place strength of high-strength concrete in structures. The prediction equation of the groove diameter of the break-off bolt(y) with the concrete strength(x) was derived as y=0.05x+3.79, with a coefficient of determination of 0.88 found through regression analysis.

Estimating Concrete Compressive Strength Using Shear Wave Velocity (전단파 속도를 이용한 콘크리트의 압축강도 추정연구)

  • An, Ji-Hwan;Nam, Jeong-Hee;Kwon, Soo-Ahn;Joh, Sung-Ho
    • International Journal of Highway Engineering
    • /
    • v.10 no.3
    • /
    • pp.171-178
    • /
    • 2008
  • Compressive strength of concrete has been regarded as a very important parameter of the quality control both in new and existing concrete pavement. It has been used a lot as the concrete strength evaluation both in the various-mixture-using laboratory and construction field using the same mixture. An error usually occurs in the test experiments of the strength, even in the test experiments with evenly mixed and compacted specimens of the compressive strength. It is caused by the 'manually operated' compressing testing, or by the specimens preparation with eccentricity. When compressive strength of evenly mixed concrete is investigated by the curing ages at the construction field, there have to be lots of specimens. And it needs much labor and cost. To substitute the endlessly repeated test experiments of compressive strength, presumption of compressive strength, by nondestructive tests, is needed. In this study, elastic waves were used among various nondestructive tests. Compressive strength of concrete was presumed according to the curing ages, by using the shear wave velocity which is not affected by restricted conditions. In the result, shear wave velocity is very closely related to the compressive strength at the evenly mixed concrete.

  • PDF