Analysis of Fission Products on Irradiated Fuels using EPMA (EPMA를 이용한 사용후핵연료의 연소도 측정에 관한 연구)

  • Jung, Yang-Hong;Yoo, Byung-Ok;Oh, Wan-Ho;Lee, Hong-Gy;Choo, Yong-Sun;Hong, Kwon-Pyo
    • Applied Microscopy
    • /
    • v.35 no.3
    • /
    • pp.113-119
    • /
    • 2005
  • The Methodology of burnup calculation with EPMA test set up in this study. The spent fuel from PWR nuclear power plant was used as specimen. This $UO_2$ fuel with 3.2% of enrichment had been irradiated up to 35,000 MWd/MTU. The burnup is very important factor for nuclear fuel to estimate all fuel behaviors in reactor. To measure amounts of fission products and actinides for the burnup calcualation, destructive method analysis has been used but it makes long experimental time and second radio-wastes. In this study, EPMA test was available to measure amount of fission products. Neodymium is able to be detected and quantified. It can be compared with the results from chemical analysis and ORIGEN-2 code calculation. Concentration of Nd from EPMA test showed good agreement with result of ORIGEN-2 code in the same burnup.

Neutron Activation Analysis of Human Hair for Human Health Assessment (인체보건 환경평가를 위한 모발의 중성자방사화분석)

  • Chung, Young-Sam;Kang, Sang-Hoon;Moon, Jong-Hwa;Kang, Young Hwan;Cho, Seung-Yon
    • Analytical Science and Technology
    • /
    • v.14 no.2
    • /
    • pp.131-139
    • /
    • 2001
  • There is personal difference in the concentrations of trace elements in human hair according to human life or history suck as occupation, race, sex, age, food habit, social condition and so on. It is also found that the individual's deviation of elemental concentrations is reflecting the degree of environmental pollutants exposure to human body, intakes of food and metabolism. To compare the degree of accumulation in the hair tissue, human hair samples were collected from five positions of head and analyzed by non-destructive neutron activation analysis with and without washing according to IAEA's recommended method. Analytical quality control is performed using the certified reference material. The relative error of Cu, Cr, Na, Co, Mg, As, Se, Zn and those of Mn, Ca, Fe, Sr are within ${\pm}5%$ and ${\pm}10%$, respectively and the relative standard deviation of elements are within ${\pm}10%$. The deviations between the individuals and hair sampling positions were estimated. The deviation of individual was seven times more than that of positions. Under the defined condition, the difference and the correlation of elemental concentrations were compared with two different groups, office and factory workers. The result can be used as a fundamental data for human health and environment assessment.

  • PDF

Discrimination of Geographical Origin for Herbal Medicine by Mineral Content Analysis with Energy Dispersive X-Ray Fluorescence Spectrometer (에너지분산형 X-선 형광분석기를 이용한 한약재의 무기질 분석 및 이에 의한 원산지 판별)

  • Jeong, Myeong-Sil;Lee, Soo-Bok
    • Korean Journal of Food Science and Technology
    • /
    • v.40 no.2
    • /
    • pp.135-140
    • /
    • 2008
  • In this study, the macromineral content ratios of four herbal medicine samples(Saposhnikoviae Radix, Bupleuri Radix, Cnidii Rhizoma, and Astragali Radix) were analyzed to discriminate their geographical origins using an energydispersive x-ray fluorescence (EDXRF) technique. EDXRF is a rapid, non-destructive, and multi-elemental analysis technique. Initially, samples of both domestic and imported herbal medicines were pulverized, and then their macromineral contents, including P, S, K, and Ca, were analyzed using EDXRF. For the discrimination of their geographical origins, canonical discriminant analysis was carried out based on the estimated macromineral relative content ratios of the samples. According to the results, the discrimination accuracies were as follows: 93.3% for Saposhnikoviae Radix, 95.7% for Bupleuri Radix, 98.8% for Cnidii Rhizoma, and 87.5% for Astragali Radix. Overall, the results imply that this technique could be used as a standard method, to discriminate their geographical origins between domestic and imported herbal medicines.

Determination of volatile and residual iodine during the dissolution of spent nuclear fuel (사용 후 핵연료 용해 중 휘발 및 잔류 요오드 분석)

  • Kim, Jung Suk;Park, Soon Dal;Jeon, Young Shin;Ha, Young Keong;Song, Kyuseok
    • Analytical Science and Technology
    • /
    • v.22 no.5
    • /
    • pp.395-406
    • /
    • 2009
  • The determination of iodine in the spent nuclear fuel and the volatile behavior during its acid dissolution have been studied by NAA(neutron activation analysis) and electron probe microanalysis (EPMA). Simulated spent fuels (SIMFUELs) were dissolved in $HNO_3$(1+1) at $90^{\circ}C$ for 8 hours. The iodine remained in a dissolver solution after dissolution, and that condensed in dissolution apparatus and trapped in the adsorbent by volatilization during the dissolution were determined, respectively. The condensed iodine was recovered by the redistillation with $HNO_3$(1+1) after transfer of the dissolver solution. The iodines in the dissolver and redistilled solution were separated by solvent extraction followed by ion exchange or precipitation method and determined by RNAA (radiochemical neutron activation analysis). The ion exchange column and filtration kit used for the isolation of iodine, which were prepared with a polyethylene tube, were used as an insert in the pneumatic tube for neutron irradiation. The iodine volatilized during the dissolution of SIMFUELs was collected in a trapping tube containing Ag-silica gel (Ag-impregnated silica gel) adsorbent, and the distribution of iodine trapped in the adsorbents were determined by EPMA. The adsorbing characteristics shown with the SIMFUELs were compared with those shown with a real spent fuel from the nuclear power plant.

Elemental Analysis by Neutron Induced Nuclear Reaction - Prompt Gamma Neutron Activation Analysis for Chemical Measurement - (중성자 핵반응을 이용한 원소 검출기술 - 즉발감마선 중성자 방사화분석법을 이용한 검출기술 -)

  • Song, Byung Chul;Park, Yong Joon;Jee, Kwang Yong
    • Analytical Science and Technology
    • /
    • v.16 no.5
    • /
    • pp.1041-1051
    • /
    • 2003
  • Neutron induced prompt gamma activation analysis (PGAA) offers a nondestructive, sensitive and relatively rapid method for the determination of trace and major elements and is proven to be convenient for online analysis of minerals, metals, coal, cement, petrochemical, coating, paper as well as many other materials and products. The technique has found many uses in medicine, industry, research, security and the detection of contraband items. This report reviews the present status and future trends of the PGAA techniques. Requirements for the system are neutron source, high resolution HPGe detectors with a high-voltage power supply, an amplifier, analog-to-digital converter, and a multichannel analyzer for the detection and measurement of prompt ${\gamma}$-ray emit form the neutron capture elements. Introducing a ${\gamma}$-${\gamma}$ coincidence system also improves the quality of the ${\gamma}$-ray spectrum by suppressing the background created from the Compton scattering of high energy prompt ${\gamma}$-rays. A PGAA system using a $^{252}Cf$ neutron source is currently under construction for the on-line measurement of several elements in aqueous samples at KAERI. The system can be applied for the detection of chemical weapons and explosives as well as various narcotics.

Assessment of Early Dental Caries by Using Optical Coherence Tomography (Optical Coherence Tomography를 이용한 초기 치아우식 검사)

  • Min, Ji-Hyun
    • Journal of dental hygiene science
    • /
    • v.16 no.4
    • /
    • pp.257-262
    • /
    • 2016
  • The purpose of this study was to assess the correlation between integrated mineral loss (volume % mineral${\times}{\mu}m$, ${\Delta}Z_{TMR}$) determined using transverse microradiography (TMR) and integrated reflectivity ($dB{\times}{\mu}m$, ${\Delta}R_{OCT}$) determined using optical coherence tomography (OCT) for detecting early dental caries with lesion depth more than $200{\mu}m$. Sixty tooth specimens were made from sound bovine teeth. They were immersed in a demineralized solution for 20, 30, and 40 days. The ${\Delta}R_{OCT}$ was obtained from the cross-sectional OCT image. The ${\Delta}Z_{TMR}$ was obtained from the TMR image. The correlation between ${\Delta}R_{OCT}$ and ${\Delta}Z_{TMR}$ was examined using Pearson correlation. The Bland-Altman plot was constructed using the ${\Delta}R_{OCT}$ and ${\Delta}Z_{TMR}$ values. A significant correlation between ${\Delta}R_{OCT}$ and ${\Delta}Z_{TMR}$ was confirmed (r=0.491, p=0.003). Moreover, most of the difference between ${\Delta}R_{OCT}$ and ${\Delta}Z_{TMR}$ was included in the error section of the Bland-Altman plot. Therefore, OCT could be used as a substitute for TMR when analyzing mineral loss in early dental caries.

Evaluation of Beef Freshness Using Visible-near Infrared Reflectance Spectra (가시광선-근적외선 반사스펙트럼을 이용한 쇠고기의 신선도 평가)

  • Choi, Chang-Hyun;Kim, Jong-Hun;Kim, Yong-Joo
    • Food Science of Animal Resources
    • /
    • v.31 no.1
    • /
    • pp.115-121
    • /
    • 2011
  • The objective of this study was to develop models to predict freshness factors (total viable counts (TVC), pH, volatile basic nitrogen (VBN), trimethylamine (TMA), and thiobarbituric acid (TBA) values) and the storage period in beef using a visible and near-infrared (NIR) spectroscopic technique. A total of 216 beef spectra were collected during the storage period from 0 to 14 d at a $10^{\circ}C$ storage. A spectrophotometer was used to measure reflectance spectra from beef samples, and beef freshness spectra were divided into a calibration set and a validation set. Multi-linear regression (MLR) models using the stepwise method were developed to predict the factors. The MLR results showed that beef freshness had a good correlation between the predicted and measured factors using the selected wavelength. The correlation of determination ($r^2$), standard error of prediction (SEP), and ratio of standard deviation to SEP (RPD) of the prediction set for TVC was 0.74, 0.64, and 2.75 Log CFU/$cm^2$, respectively. The $r^2$, SEP, and RPD values for pH were 0.43, 0.10, and 1.10; those for VBN were 0.73, 1.45, and 2.00 mg%; those for TMA were 0.70, 0.19, and 2.58 mg%; those for TBA values were 0.73, 0.13, and 2.77 mg MA/kg; and those for storage period were 0.77, 1.94, and 2.53 d, respectively. The results indicate that visible and NIR spectroscopy can predict beef freshness during storage.

Structural Integrity Evaluation of Nozzle Assembly using Acoustic Emission Technique (음향방출법을 응용한 노즐 조립체의 구조건전성 평가)

  • 설창원;이기범
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.34 no.10
    • /
    • pp.32-39
    • /
    • 2006
  • An acoustic emission technique was applied to the structural strength test for the structural integrity evaluation of the nozzle assembly. These AE results were compared with data from the strain gages and displacement transducer. NDT using X-ray technique was performed to improve the test reliability before and after each test. In this structural integrity evaluation of the nozzle assembly, the internal crack initiation in the structure could not be precisely revealed by the strain and displacement results but the location and load level of the initiated crack could be precisely evaluated by using AE technique. From this test, it was proven that some new cracks can be generated in composite liner of nozzle assembly under the unexpected load due to interference between obturator and nozzle and these can be a cause of the unexpected abnormal failure.

Establishment of Ultrasonic Measurement Method for Stone Cultural Heritage Considering Water Content and Anisotropy (함수율과 이방성을 고려한 석조문화유산의 초음파 측정방법 설정)

  • Jo, Young Hoon;Lee, Chan Hee
    • Journal of Conservation Science
    • /
    • v.30 no.4
    • /
    • pp.467-480
    • /
    • 2014
  • This study was focused on measurement methods for stone cultural heritages by analyzing Ultrasonic (P-wave) velocity variations according to the water content and anisotropy of rocks. As a result of analyzing of rock properties, the water content and saturation degree were rapidly changed at the beginning of drying and then showed exponential curve which their rates of change gradually decreased. However, P-wave velocity and its rate of change maintained constant values after natural drying of 10 hours. Therefore, the ultrasonic measurement for stone cultural heritages should be performed after natural drying of 10 hours considering the weather and moisture conditions. In addition, the highest values of anisotropy coefficient exhibited in granite and limestone, and indirect method was insensitive to anisotropy compared to direct method. However, all rocks remained anisotropy by indirect method. Accordingly, ultrasonic measurement considering various directions is required. The research results will contribute to customized non-destructive testing and precise diagnosis for lithological characteristics of stone cultural heritage.

Evaluation of Layer Moduli of 4 Layered Flexible Pavement Structures Using FWD (FWD에 의한 4층 아스팔트 포장 구조체의 층별 탄성계수 추정)

  • Kim, Soo Il;Yoo, Ji Hyeung
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.10 no.2
    • /
    • pp.67-78
    • /
    • 1990
  • An inverse self-iterative procedure is developed to determine layer moduli which are significant for the structural evaluation of pavements in developing rational and analytical rehabilitation technique. Falling weight deflectometer(FWD) is adopted as a non-destructive testing(NDT)device. The layer elastic theory is used to interpret NDT data. The theoretical deflection basins of pavement structures obtained by full factorial design are used for a parametric study on the characteristics of deflection basins and regression analyses. Regression equations to estimate layer moduli of flexible pavements are proposed through the regression analyses of theoretical deflection basins. The relationships between the rate of change of moduli and deflections are developed for the efficient iteration. An inverse self-iterative procedure to ensure the accuracy of the layer moduli is proposed. Validity and applicability of the developed procedure are verified through various numerical model tests.