• Title/Summary/Keyword: 비커스

Search Result 147, Processing Time 0.021 seconds

Statistical Properties of Vickers Hardness of Post Weld Heat Treated Friction Welded Parts in Alloy718 (Alloy718 마찰용접 후열처리재의 비커스 경도의 통계적 성질)

  • Kong, Yu-Sik;Kwon, Hyeok-Yong;Kim, Seon-Jin
    • Journal of Ocean Engineering and Technology
    • /
    • v.23 no.6
    • /
    • pp.105-110
    • /
    • 2009
  • The objective of this paper is to investigate the statistical properties of Vickers hardness (HV) for friction welded parts in a Ni-based super alloy (Alloy718). In the case of post weld heat treatment (PWHT) parts, hardness tests were repeated for three different applied loads, 100, 200, and 300 g, with a duration time of 10 seconds. The arithmetic means of the Vickers hardness in heat affected zone (HAZ) materials were smaller than those of the base metal (BM) in all of the applied loads. The coefficient of variation (COV) for the BM and HAZ decreased by increasing the applied load. The probability distribution of the Vickers hardness followed the Weibull distribution well. The distribution of the Vickers hardness was not found to be symmetric. The shape parameter and scale parameter increased by increasing the applied load at both the BM and HAZ.

Weibull Statistical Analysis of Micro-Vickers Hardness using Monte-Carlo Simulation (몬테카를로 시뮬레이션에 의한 미소 비커스 경도의 Weibull 통계 해석)

  • Kim, Seon-Jin;Kong, Yu-Sik;Lee, Sang-Yeal
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.33 no.4
    • /
    • pp.346-352
    • /
    • 2009
  • In the present study, the Weibull statistical analysis using the Monte-Carlo simulation has been performed to investigate the micro-Vickers hardness measurement reliability considering the variability. Experimental indentation test were performed with a micro-Vickers hardness tester for as-received and quenching and tempering specimens in SCM440 steels. The distribution of micro-Vickers hardness is found to be 2-parameter Weibull distribution function. The mean values and coefficients of variation (COV) for both data set are compared with results based on Weibull statistical analysis. Finally, Monte-Carlo simulation was performed in order to evaluate the effect of sample size on the micro-Vickers hardness measurement reliability. For the parent distribution with shape parameter 30.0 and scale parameter 200.0 (COV=0.040), the number of sample data required to obtain the true Weibull parameters was founded by 20. For the parent distribution with shape parameter 10.0 and scale parameter 200.0 (COV=0.1240), the number of sample data required to obtain the true Weibull parameters was founded by 30.

The Signal Characteristics from Crack of Brittle Materials by Vickers Load (비커스 압입 하중에 의한 취성재료의 균열 신호특성)

  • Nam, Ki-Woo;Kim, Hyun-Soo
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.22 no.2
    • /
    • pp.125-131
    • /
    • 2002
  • we analyzed acoustic emission signals obtained from three kinds of brittle materials under compression load by Vickers hardness tester. The results obtained can be summarized as follows; The signal in each material could be divided into three signal based on the properties of load. All specimens were not detected acoustic emission signals in stage II which was load constant region., and were detected in stage I and stage III. Glass was detected high amplitude signals in stage III. $Al_2O_3\;and\;Al_2O_3/Sic$ were detected high amplitude signals in stage I.

Effects of Cerium Oxide Nano Particles(CNP) Containing on The Mechanical of Pit and Fissure Sealant (세륨옥사이드나노입자(CNP)첨가가 치면열구전색재 기계적 성질에 미치는 영향)

  • Jeong, Mi-Ae;Kim, Dong-Ae
    • The Journal of the Korea Contents Association
    • /
    • v.20 no.6
    • /
    • pp.433-438
    • /
    • 2020
  • The aim of this study was to investigate the mechanical properties of pit and fissure sealant containing cerium oxide nano particles(CNP). Used to mix with pit and fissure sealant (ConciseTM, USA). CNP was added into liquid (0- 4.0 wt%) of pit and fissure sealant. The specimens for the vickers hardness (VHN; 10 × 2 mm), Three-point flexure (FS; 2 × 2 × 25 mm) with flexure modulus (FM) were obtained from cements at 1, 7, and 14 days after storing in (37±1)℃ distilled water. All mechanical strength tests were conducted using machine (Instron 3344) with a cross-head speed of 1 mm/min. Data were statistically analyzed by one-way ANOVA and Duncan posthoc test(p<0.05). Mechanical properties of conventional pit and fissure sealant could be enhanced by addition of CNP. Three-point flexure and modulus of pit and fissure sealant containing CNP were showed a slightly higher value not significantly with the group(p>0.05). The vickers hardness values were increase significantly with incubation time(p<0.05). Results indicated that CNP can be used considered as potential reinforcing agent for increasing mechanical properties for conventional pit and fissure sealant. Therefore, it was suggest that the additional effects of CNP and research on a wide range of substances.

Antibacterial and Mechanical Properties of Glass Ionomer Cements Containing Functionalized Multi-wall Carbon Nanotube(MWCNT) (기능화 다중벽 탄소나노튜브를 첨가한 글라스아이오노머 시멘트의 항균효과 및 기계적 성질)

  • Jeong, Mi-Ae;Kim, Dong-Ae
    • The Journal of the Korea Contents Association
    • /
    • v.17 no.10
    • /
    • pp.300-306
    • /
    • 2017
  • The purpose of this study was to investigate the antibacterial effect of functional multiwall carbon nanotube (MWCNT) on the conventional glass ionomer cement(GIC). The MWCNT was incorporated into a commercial powder at 0.125, 0.25, 0.5 and 1.0 wt%. Specimens for vickers hardness(VHN) disks(Ø$10mm{\times}2mm$) each were prepared. Indention were made using a load of 200 N and 20 s dwell on four specimens for each distilled water storage time 1d, 7d, and 14days. The antibacterial effects using agar diffusion test with S. mutans and S. aureus. The diameters of the inhibition zones produced around the materials were measured. The results revealed that all the vickers hardness values were increase significantly with incubation time(p<0.05). Regarding the antibacterial effect for S. mutans, all the tested groups showed a slightly higher value not significantly with the control group(p<0.05). However S. aureus statistical analysis indicated a significant difference for antibacterial agents between control and MWCNT containing 0.25 wt%(p<0.05). These results of this study provide that the conventional GIC with containing MWCNT show good antibacterial effect against and favorable mechanical properties. Further this study on the efficient functionalization of multiwall carbon nanotube will be needed.

Correlation Between Mechanical and Magnetic Properties for Cold Rolled Carbon Steel Sheet (냉연강판의 기계적 물성과 자기적 특성의 상관관계)

  • Park, S.Y.;Ryu, K.S.;Yi, J.K.;Park, J.S.
    • Journal of the Korean Magnetics Society
    • /
    • v.16 no.4
    • /
    • pp.211-215
    • /
    • 2006
  • Measurement methods in order to measure the mechanical properties nondestructively have been studied. The mechanical properties of the structural and turbine rotor steels are related with their magnetic properties. If the magnetic properties of the cold rolled carbon steel sheet (CR) for a car are measured nondestructively, its mechanical properties are analogized by their magnetic properties. And then the mechanical properties are monitored on-line by measuring the magnetic properties. We prepared three CR materials, CBQ 3060, CBQ 3041, and CBQ 3036, were prepared in order to measure their mechanical and magnetic properties. The Vickers hardness,yield strength, and tensile strength were measured by ASTM E 8M, and the reversible magnetic permeability was measured by the surface type probe. The coercivity calculated by the peak interval of reversible magnetic permeability increased linearly with the increase of Vickers hardness, yield strength, and tensile strength. The amplitude of the peak interval of reversible magnetic permeability drastically decreased when the lift-off was increased.

An Experimental Study on the Relation between Flow Stress and Vickers Hardness (유동응력과 비커스경도의 관계 실험적 연구)

  • 이충호
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 1997.03a
    • /
    • pp.65-68
    • /
    • 1997
  • Vickers hardness is defined as indenting force per unit area indented by a pyramid-shaped diamond at the hardness test. It is well known that Vickers hardness has a direct relation with the flow stress of the strain-hardened material. This relation was theoretically investigated and the result was summerized in a form of algebraic equation in the last paper. In the present paper and experimental validation of this theoretical relation is given along with mathematical formulas for conversion of Vickers hardness into the flow stress in the strain-hardened material for practical use.

  • PDF

A Study on the Theoretical Relation between Flow Stress and Vickers Hardness (유동응력과 비커스경도의 이론적 관계 연구)

  • 이충호
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 1997.03a
    • /
    • pp.69-72
    • /
    • 1997
  • The indentation process in the Vickers hardness test is a kind of controlled local plastic deformation. Vickers hardness is defined as indenting force per unit area indented by a pyramid-shaped diamond at the hardness test. That is a measure of mechanical resistance against indentation of a rigid body into the deformable material. Therefore it is well known that Vickers hardness has a direct relation with the flow stress of the strain-hardened tmaterial. This relation is theoretically investigated and the result is given for use in practice.

  • PDF