• Title/Summary/Keyword: 비침습

Search Result 712, Processing Time 0.032 seconds

Frequency-domain Diffuse Optical Tomography System Adopting Lock-in Amplifier (Lock-in 증폭기를 채용한 주파수영역 확산 광단층촬영 시스템)

  • Jun, Young-Sik;Baek, Woon-Sik
    • Korean Journal of Optics and Photonics
    • /
    • v.22 no.3
    • /
    • pp.134-140
    • /
    • 2011
  • In this paper, we developed a frequency-domain diffuse optical tomography(DOT) system for non-invasively imaging in vivo. The system uses near-infrared(NIR) light sources and detectors for which the photon propagation in human tissue is dominated by scattering rather than by absorption. We present the experimental reconstruction images of absorption and scattering coefficients using a liquid tissue phantom, and we obtain the location and shape of an anomaly which has different optical properties than the phantom.

Implementation of the Wearable SpO2 Monitoring System Using Optical Compensation Method (광보정기법을 적용한 착용형 산소포화도 모니터링 시스템 구현)

  • Kim, Hyun-Su;Jeong, Do-Un
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2016.10a
    • /
    • pp.879-881
    • /
    • 2016
  • 비침습적 맥파측정은 일상생활에서 손쉽게 활용이 가능하며 맥파신호의 계측을 통하여 건강모니터링을 함으로서 사용자의 지속적인 건강관리에 도움이 된다. 일반적인 맥파 측정을 위해선 경동맥, 대퇴골, 요골 동맥을 포함 만져서 할 수 있는 동맥에서 측정되거나 맥파 측정장비를 사용하여 측정하게 된다. 본 연구에서는 실시간 맥파측정과 병행하여 산소포화도의 모니터링을 위해 손목착용형 시스템을 구현하고 산소포화도의 추정 정확도를 높이기 위하여 광보정기법을 적용하였다. 실제 자연광 상태에서의 측정된 신호를 이용하여 광보정기법을 적용한 산소포화도 모니터링 기법을 적용하고 그 성능평가를 수행하였다.

  • PDF

Security Technology Trends to Prevent Medical Device Hacking and Ransomware (커넥티드 의료기기 해킹 및 랜섬웨어 대응기술 동향)

  • Kwon, H.C.;Chung, B.H.;Moon, D.S.;Kim, I.K.
    • Electronics and Telecommunications Trends
    • /
    • v.36 no.5
    • /
    • pp.21-31
    • /
    • 2021
  • Ransomware attacks, such as Conti, Ryuk, Petya, and Sodinokibi, that target medical institutions are increasing rapidly. In 2020, in the United States., ransomware attacks affected over 600 separate clinics, hospitals, and organizations, and more than 18 million patient records. The cost of these attacks is estimated to be almost $21 billion USD. The first death associated with a ransomware attack was reported in 2020 by the University Hospital of Düesseldorf in Germany. In the case of medical institutions, as introduced in the Medjack report issued by TrapX Labs, in many cases, attackers target medical devices that are relatively insecure and then penetrate deep into more critical network infrastructure, such as EMR servers. This paper introduces security vulnerabilities of hospital medical devices, considerations for ransomware response by medical institutions, and related technology trends.

Non-invasive quantification methods for glucose monitoring (포도당 모니터링을 위한 비침습적 정량화 방법)

  • Young Ho, Kim;Yeong-Seo, Park;Byeong Uk, Park;inkwon, Yoon;Hee-Jae, Jeon
    • Journal of Industrial Technology
    • /
    • v.42 no.1
    • /
    • pp.13-18
    • /
    • 2022
  • Diabetes mellitus is an abnormally high glucose level in the bloodstream. Several pharmaceuticals are administered to diabetic patients to control their glucose levels. Early diagnosis and proper glycemic management are essential in this situation to prevent further progression and complications. Biosensor-based detection has progressed and shown potential in portable and inexpensive daily assessment of glucose levels because of its simplicity, low cost, and convenient operation without sophisticated instrumentation. This review discusses various systemic aspects of non-invasive glucose monitoring, including materials for monitoring and managing diabetes.

A Study on Brain Activation during playing a computer game using a fNIRS (컴퓨터 게임 중 fNIRS 기반 뇌 활성화 연구)

  • Kang, Won-Seok;Abibullaev, Berdakh;Lee, SeungHyun;An, Jinung
    • Annual Conference of KIPS
    • /
    • 2009.11a
    • /
    • pp.407-408
    • /
    • 2009
  • fNIRS(functional Near Infrared Spectroscopy)는 비침습형 뇌기능 분석 시스템으로 뇌활성화 시 옥시 헤모글로빈(oxy-hemoglobin)과 디옥시헤모글로빈(deoxy-hemoglobin) 변화량을 측정할 수 있는 장치이다. 본 논문에서는 뇌기능 분석 장치인 fNIRS를 이용하여 피험자가 컴퓨터 게임 중에 어떤 뇌활성화 패턴을 보이는지를 실험하였다. 컴퓨터 게임 주의 및 집중 시 뇌의 전두엽(Frontal Lobe) 영역이 활성화 및 변화되는 것을 실험결과로 확인하였다. 그리고 게임 중 다른 사람이 피험자에게 개입을 하였을 때 전두엽의 활성화 영역이 다른 패턴을 보이는 것을 실험결과로 확인하였다.

Development of a Mobile Game-Based Digital Therapeutic Device for Symptom Alleviation in Post-Traumatic Stress Disorder Patients (외상후 스트레스장애 환자의 증상 완화를 위한 모바일 게임 기반의 디지털치료기기 개발)

  • Dawon Suh;Nan Park;Inseong Baek;Gahyeon Kim;Yoonjin Cho;JeongEun Nah
    • Annual Conference of KIPS
    • /
    • 2023.11a
    • /
    • pp.822-823
    • /
    • 2023
  • 외상후 스트레스 장애(PTSD)는 장기적으로 심각한 기능 장애를 초래하므로 적절한 치료가 필수적이다. 현재 PTSD 치료법 중 효과가 검증된 주류 심리치료는 환자에게 정서적 고통을 유발하여 치료 중도 포기를 야기하고 치료 효과를 감소시키는 주요한 원인이다. 본 연구에서는 생성형 AI를 적용하여 사용자의 맞춤형 트라우마 이미지를 무의식적으로 노출시키는 방식으로 게임에 적용하였다. 개발된 게임은 디지털 치료기기로 사용함으로써 비침습적인 방법으로 치료의 효과를 증대한다.

Development of a real-time prediction model for intraoperative hypotension using Explainable AI and Transformer (Explainable AI와 Transformer를 이용한 수술 중 저혈압 실시간 예측 모델 개발)

  • EunSeo Jung;Sang-Hyun Kim;Jiyoung Woo
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2024.01a
    • /
    • pp.35-36
    • /
    • 2024
  • 전신 마취 수술 중 저혈압의 발생은 다양한 합병증을 유발하며 이를 사전에 예측하여 대응하는 것은 매우 중요한 일이다. 따라서 본 연구에서는 SHAP 모델을 통해 변수 선택을 진행하고, Transformer 모델을 이용해 저혈압 발생 여부를 예측함으로써 임상적 의사결정을 지원한다. 또한 기존 연구들과는 달리, 수술실에서 수집되는 데이터를 기반으로 하여 높은 범용성을 가진다. 비침습적 혈압 예측에서 RMSE 9.46, MAPE 4.4%를 달성하였고, 저혈압 여부를 예측에서는 저혈압 기준 F1-Score 0.75로 우수한 결과를 얻었다.

  • PDF

The Usefulness of Noninvasive Positive Pressure Ventilation in Patients With Acute Respiratory Failure after Extubation (기관내 관 제거 후 발생한 급성 호흡부전에서 비침습적 양압 환기법의 유용성)

  • Na, Joo-Ock;Lim, Chae-Man;Shim, Tae-Sun;Park, Joo-Hun;Lee, Ki-Man;Lee, Sang-Do;Kim, Woo-Sung;Kim, Dong-Soon;Kim, Won-Dong;Koh, Youn-Suck
    • Tuberculosis and Respiratory Diseases
    • /
    • v.46 no.3
    • /
    • pp.350-362
    • /
    • 1999
  • Background: Acute Respiratory failure which is developed after extubation in the weaning process from mechanical ventilation is an important cause of weaning failure. Once it was developed, endotracheal reintubation has been done for respiratory support. Noninvasive Positive Pressure Ventilation (NIPPV) has been used in the management of acute or chronic respiratory failure, as an alternative to endotracheal intubation, using via nasal or facial mask. In this study, we evaluated the usefulness of NIPPV as an alternative method of reintubation in patients who developed acute respiratory failure after extubation. Method: We retrospectively analyzed thirty one patients(eighteen males and thirteen females, mean ages $63\pm13.2$ years) who were developed acute respiratory failure within forty eight hours after extubation, or were extubated unintentionally at medical intensive care unit(MICU) of Asan Medical Center. NIPPV was applied to the patients. Ventilatory mode of NIPPV, level of ventilatory support and inspiratory oxygen concentration were adjusted according to the patient condition and results of blood gas analysis by the attending doctors at MICU. NIPPV was completely weaned when the patients maintained stable clinical condition under 8 $cmH_2O$ of pressure support level. Weaning success was defined as maintenance of stable spontaneous breathing more than forty eight hours after discontinuation of NIPPV. Respiratory rate, heart rate, arterial blood gas analysis, level of pressure support, and level of PEEP were monitored just before extubation, at thirty minutes, six hours, twenty four hours after initiation of NIPPV. They were also measured at just before weaning from NIPPV in success group, and just before reintubation in failure group. Results: NIPPV was successfully applied to thirty-one patients of thirty-two trials and one patient could not tolerated NIPPV longer than thirty minutes. Endotracheal reintubation was successfully obviated in fourteen patients (45%) among them. There was no difference in age, sex, APACHE III score on admission at MICU, duration of intubation, interval from extubation to initiation of NIPPV, baseline heart rate, respiratory rate, arterial blood gas, and $PaO_2/FiO_2$ between the success and the failure group. Heart rate and respiration rate were significantly decreased with increase $SaO_2$ after thirty minutes of NIPPV in both groups(p<0.05). However, in the patients of failure group, heart rate and respiratory rate were increased again with decrease in $SaO_2$ leading to endotracheal reintubation. The success rate of NIPPV treatment was significantly higher in the patients with COPD compared to other diseases(62% vs 39%) (p=0.007). The causes of failure were deterioration of arterial blood gas without aggravation of underlying disease(n=9), aggravation of undelying disease(n=5), mask intolerance(n=2), and retained airway secretion(n=l). Conclusion: NIPPV would be a useful therapeutic alternative which can avoid reintubation in patient who developed acute respiratory failure after extubation.

  • PDF

A Clinical Study on the Effects of Extravascular Laser System on Osgood-Schlatter Disease (비침습 레이저 조사기를 이용한 Osgood-Schlatter's disease의 치료 증례보고)

  • Suk, Yun Hee;Min, Sang Yeon;Kim, Jang Hyun
    • The Journal of Pediatrics of Korean Medicine
    • /
    • v.26 no.4
    • /
    • pp.77-83
    • /
    • 2012
  • Objectives: The purpose of this study was to assess the effect of Extravascular Laser System on Osgood-Schlatter Disease Methods: In this study, we treated the 6 cases of children who were diagnosed with Osgood-Schlatter disease with Extravascular Laser System. 4 of them were treated with acupuncture as well, the other 2 were given with combined acupuncture and Blood-pricking Treatment. For evaluation, 6 children explained the degree of pain relief by comparing with degree of pain before treatment. Results: Extravascular Laser System for Osgood-Schlatter Disease resulted in a significant decline in the subjective pain degree. All of them were almost cured. The average treatment times was 6.7 times, and the average treatment period was 26.7days. Conclusions We report the good result of the efficacy of extravascular laser system on Osgood-Schlatter Desease. Cases in this study, however, were small in number. Therefore more study is required.

The characteristic analysis of EEG artifacts (EEG 잡파 특성 분석)

  • Yang, Eun-Joo;Shin, Dong-Sun;Kim, Eung-Soo
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.12 no.4
    • /
    • pp.366-372
    • /
    • 2002
  • EEG is the electrical signal, which is occurred during information processing in the brain. These EEG signal are measured by non-invasive method. EEG has many useful information for brain activity, but artifacts which are included in EEG prevents EEG analysis, so many efforts are devoted to remove these artifacts in EEG. However, this study is going to analysis the feature of the EEG mixed with artifacts in forward-looking way, by using this way, we have found the possibility that is actually applicable to system such as control system. We have made feature difference after the linear as well as nonlinear analysis regarding EEG including typical artifacts, eye-blinking, eye rolling, muscle, and so forth.