• Title/Summary/Keyword: 비지면

Search Result 327, Processing Time 0.025 seconds

Analysis on the Rigid Connections of the Drilled Shaft with the Cap for Multiple Pile Foundations (현장타설말뚝을 적용한 다주식 기초에서 말뚝과 캡의 강결합에 대한 분석)

  • Cho, Sung-Min
    • Journal of the Korean Geotechnical Society
    • /
    • v.24 no.7
    • /
    • pp.61-73
    • /
    • 2008
  • Piles of a bridge pier are connected with the column through the pile cap (footing). Behavior of the pile foundation can be different according to the connection method between piles and the pile cap. Connection methods between pile heads and the pile cap are divided into two groups : rigid connections and hinge connections. Domestic design code has been specified to use rigid connection method for the highway bridge. In the rigid connection method, maximum bending moment of a pile occurs at the pile head and this helps the pile to prevent the excessive displacement. Rigid methods are also good to improve the seismic performance. However, some specifications prescribe that conservative results through investigations of both the fixed-head condition and the free-head condition should be reflected in the design. This statement may induce an over-estimated design for the bridge which has high-quality structures with casing covered drilled shafts and the PC-house contained pile cap. Because the assumption of free-head conditions (hinge connections) is unreal for the elevated pile cap system with multiple piles of the long span sea-crossing bridges. On the other hand, elastic displacement method to evaluate the pile reactions under the pile cap is not suitable for this type of bridges due to impractical assumptions. So, full modeling techniques which analyze the superstructure and the substructure simultaneously should be performed. Loads and stress state of the large diameter drilled shaft and the pile cap for Incheon Bridge which will be the longest bridge of Korea were investigated through the full modeling for rigid connection conditions.

Changes of Soil Temperature and Moisture under the Agrivoltaic Systems in Fallow Paddy Field during Spring Season (봄철 영농형 태양광 시설 하부 휴경논 토양의 온도와 수분 변화)

  • Yuna Cho;Euni Cho;Jae-Hyeok Jeong;Hoejeong Jeong;Woon-Ha Hwang;Jaeil Cho
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.25 no.3
    • /
    • pp.218-225
    • /
    • 2023
  • An agrivoltaic system (AVS) is a combined system that generates power through photovoltaic panels (PVPs) installed above a field where a crop is cultivated. Although soil moisture is an important limiting factor for open-field crop production, particularly during spring season in Korea, it is not well considered in the utilization of AVS. Indeed, the application of water-energy-food nexus on the AVS should be necessary. In this study, the changes of soil moisture and temperature under the AVS was investigated in fallow paddy field during spring season. The AVS that has partial shading condition by PV panels was decreased soil temperature and increased soil moisture compared to open-field. Furthermore, the maximum of the change in soil moisture to the change in soil temperature had a negative correlation both on open-field and AVS under wet condition. It represents that the micro-climate under the AVS is in energy-limited condition. The open-field of relatively high soil temperature was in water-limited condition. The different behavior of soil moisture on the AVS should be considered for the sustainable agricultural system as related to water-energy-food nexus.

Annealing Cycle Dependence of MR Properties for Free Layer in $Ni_{25}Mn_{75}-Spin$ Valve Films ($Ni_{25}Mn_{75}-Spin$ Valve 박막 자유층의 열처리 순환수에 따른 자기저항 특성)

  • 이낭이;이주현;이가영;김미양;이장로;이상석;황도근
    • Journal of the Korean Magnetics Society
    • /
    • v.10 no.2
    • /
    • pp.62-66
    • /
    • 2000
  • Annealing cycle number and nonmagnetic layer thickness dependences of interlayer coupling field ( $H_{inf}$ ) and coercivity ( $H_{cf}$ ) of free magnetic layer on NiMn alloy-spin valve films (SVF) were investigated. The SVF is Glass (7059)/N $i_{81}$F $e_{l9}$(70 $\AA$)/Co(10 $\AA$)/Cu(t $\AA$)/Co(15 $\AA$)N $i_{81}$$Fe_{19}$(35 $\AA$)/N $i_{25}$M $n_{75}$(250 $\AA$)Ta(50 $\AA$) films, it were fabricated using the dc sputtering method at different pinning layer thickness and nonmagnetic spacer thickness (Cu thickness; 30 $\AA$, 35 $\AA$, 40 $\AA$) of NiMn alloy with 25 at.%. Ni In case that Cu thickness of SVF is 35 $\AA$ and peak exchange coupling field ( $H_{ex}$) was 620 Oe, while coercivity $H_{c}$ = 280 Oe and MR ratio showed 2.5%. As for $H_{inf}$ and $H_{cf}$ , every SVF increased up to the stabilized values with the increase of annealing cycle number 15, which were $H_{inf}$ of 120 Oe and $H_{cf}$ of 75 Oe. The increase of $H_{cf}$ with the annealing cycle number seems to be caused by the effective reduction of Cu layer thickness due to the increase of interfacial mixing of Cu layer and Co layer. In addition, the $H_{inf}$ and $H_{cf}$ dependences of free NiFe layer by the interfacial mixing effect were appeared the different aspects when Cu layer becomes more thinner and thicker than Cu layer thickness of 35 $\AA$, respectively.ively....

  • PDF

Growth and Water Use Efficiency of Major Tree Species for Rehabilitation and the Impacts of Planting Trees on Microclimate Condition in Central Dry Zone of Myanmar (미얀마 건조지에서 주요 조림 수종의 생장과 수분이용효율 특성 및 조림이 건조지의 미세기상변화에 미치는 영향)

  • Park, Go Eun;Kim, Chan Beom;An, Jiae;Thang, Tluang Hmung;Maung, Wai Phyoe;Wai, Khaing Hsu;Kwon, Jino;Park, Chanwoo
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.18 no.4
    • /
    • pp.327-336
    • /
    • 2016
  • The Bagan, the central part of Myanmar, is dry zone where the mean annual precipitation is less than 600 mm for the last ten years. Forest in this region has been degraded due to biotic and abiotic disturbances. While there have been various efforts to rehabilitate the degraded area, the information on growth and physiological characteristics of planting species and the impacts of planting trees in the region still lacks. Therefore, this study was conducted to determine the growth and physiological water use efficiency characteristics of five species (Azadirachta indica A. Juss., Acacia catechu Willd., Eucalyptus camaldulensis Dehn., Acacia leucophloea (Roxb.) Willd. and Albizia lebbek (L.) Willd.) which are utilized as rehabilitation species in the dry zone and to identify the impacts of tree planting on microclimate change in dry zone. The growth and the foliar carbon isotope composition of seedlings and the above mentioned five species planted in 2005 were measured. And from February 2015 to January 2016, microclimatic factors air temperature and relative humidity at 60 cm and 2 m above soil, soil temperature, soil water contents and precipitation were measured at every 30-minute interval from the two weather stations installed in the plantation located in Ngalinpoke Mt. Range. One was established in the center of A. indica plantation, and the other was in the barren land fully exposed to the sunlight. Among the five species, A. indica and A. lebbek which showed higher water use efficiency could be recommended as rehabilitation species in dry zone. Planting trees in the dry area was shown to affect the change of microclimate with shading effects, declining temperature of the land surface and aridity of the air, and to contribute to conserving more water in soil by preventing direct evaporation and containing more water with fine roots of trees.

The Effects of Formative Assessment Using Mobile Applications on Interest and Self-Directedness in Science Instruction (모바일을 활용한 형성평가가 과학수업의 흥미성과 자기주도성에 미치는 영향)

  • Kwak, Hyoungsuk;Shin, Youngjoon
    • Journal of The Korean Association For Science Education
    • /
    • v.34 no.3
    • /
    • pp.285-294
    • /
    • 2014
  • This study investigates the effects of formative assessment utilizing mobile applications on interest and self-directedness in science instruction. The study subjects are two 6th grade classes from H elementary school located in Incheon, and the experimental group and the comparative group are composed of 21 students, respectively. The students from the experimental group have been taught with mobile devices while the comparative group has been taught in methods consistent with the current teaching standards. For the sake of research, the results of the method applied to the mobile device focus group have been edited using Google Drive Forms, entered as QR codes and stored in order for them to later be utilized for teaching and learning process. In the process, the teacher has provided the students with feedback based on their answers. The students of comparative group are to solve the same formative assessment in paper. As a result, the teacher of the mobile device focus group has been able to go through twenty-nine questions on formative assessment in the teaching and learning process, confirm the correct answers five times and provide feedback twenty-five times for additional explanation. In the inquiry about interest, the mobile device group scored 4.64 points and the standard one scored just 1.99 points (p<0.01). Fifteen students answered in the interview that and the major reason why they scored high has been because it was fun to study with mobile devices. When it comes to self-directedness over the process of teaching and learning, the mobile device focus group has answered positively but the standard group has scored relatively low (p<0.01).

Identification of Major Broad Leaved Weed Seedlings Based on Morphological Characteristics (주요 광엽잡초 유묘의 형태적 특성을 기초로 한 간이 식별법)

  • Kim, Chang-Seok;Chung, Young-Jae;Lee, In-Yong;Cho, Jung-Lai;Oh, Se-Mun;Park, Jae-Eup
    • Korean Journal of Weed Science
    • /
    • v.30 no.1
    • /
    • pp.1-16
    • /
    • 2010
  • This study was conducted to develope identification method with major broad leaved weed seedlings. Characteristics of weed seedlings were investigated at two to four true leaf stage. Qualitative characteristics were more useful to identification of weed species than quantitative characteristics at the seedling stage. Many species were elliptic and broadly elliptic type in their cotyledon shape. Cotyledon shape of Cassia nomame and Calystegia sepium were broadly oblong. Four species were transverse broadly elliptic in their cotyledon shape. Rumex japonicus, Persicaria hydropiper, Euphorbia supina and Acalypha australis have three or more types in their cotyledon shape. Cotyledons of Vigna angularis var. nipponensis remained below ground after its germination. Many species were round in apex and were cuneate in base of cotyledon. Humulus japonicus and Polygonum aviculare were sessile in cotyledon base. The second true leaf shape of some species changed after first leaf stages. Glycine soja, V. angularis var. nipponensis and Kummerowia striata were broadly ovate, heart-shaped, orbicular or broadly obovate in their first true leaf, respectively, but the second true leaf shape of them were tripalmately compound. Aeschynomene indica and Cassia nomame were paripinnately compound leaf in their first and second true leaves. Margin of true leaves were entire in many species but six species including Xanthium occidentale were dentate in their true leaf margins. Margin of Euphorbia supina was entire in first true leaf and dentate in second true leaf. Margin of Chenopodium album and C. serotinum were entire in their first true leaf stage and erose in their second true leaf stage. The key for weed seedling identification of major weed species were made based on quantitative and qualitative morphological characteristics.

Carbon Monoxide Dispersion in an Urban Area Simulated by a CFD Model Coupled to the WRF-Chem Model (WRF-Chem 모델과 결합된 CFD 모델을 활용한 도시 지역의 일산화탄소 확산 연구)

  • Kwon, A-Rum;Park, Soo-Jin;Kang, Geon;Kim, Jae-Jin
    • Korean Journal of Remote Sensing
    • /
    • v.36 no.5_1
    • /
    • pp.679-692
    • /
    • 2020
  • We coupled a CFD model to the WRF-Chem model (WRF-CFD model) and investigated the characteristics of flows and carbon monoxide (CO) distributions in a building-congested district. We validated the simulated results against the measured wind speeds, wind directions, and CO concentrations. The WRF-Chem model simulated the winds from southwesterly to southeasterly, overestimating the measured wind speeds. The statistical validation showed that the WRF-CFD model simulated the measured wind speeds more realistically than the WRF-Chem model. The WRF-Chem model significantly underestimated the measured CO concentrations, and the WRF-CFD model improved the CO concentration prediction. Based on the statistical validation results, the WRF-CFD model improved the performance in predicting the CO concentrations by taking complicatedly distributed buildings and mobiles sources of CO into account. At 04 KST on May 22, there was a downdraft around the AQMS, and airflow with a relatively low CO concentration was advected from the upper layer. Resultantly, the CO concentration was lower at the AQMS than the surrounding area. At 15 KST on May 22, there was an updraft around the AQMS. This resulted in a slightly higher CO concentration than the surroundings. The WRF-CFD model transported CO emitted from the mobile sources to the AQMS measurement altitude, well reproducing the measured CO concentration. At 18 KST on May 22, the WRF-CFD model simulated high CO concentrations because of high CO emission, broad updraft area, and an increase in turbulent diffusion cause by wind-shear increase near the ground.

Development of Rain Shelter for Chinese Cabbage Rainproof Cultivation (배추재배용 비가림하우스 개발)

  • Yu, In Ho;Lee, Eung Ho;Cho, Myeong Whan;Ryu, Hee Ryong;Moon, Doo Gyung
    • Journal of Bio-Environment Control
    • /
    • v.23 no.4
    • /
    • pp.293-302
    • /
    • 2014
  • This study was carried out to develop rain shelter which can make an appropriate size and environment for Chinese cabbage rainproof cultivation. Fifty three farms with chinese cabbage rainproof cultivation system have been investigated to set up width and height of rain shelter. Mostly the width of 6m was desired for rain shelter and the height of 1.6m for their eaves, so these values were chosen as the dimensions for rain shelter. After an analysis of their structural safety and installation costs by the specifications of the rafter pipe, Ø$25.4{\times}1.5t$ and 90cm have been set as the size of rafter that such size costs the least. This size is stable with $27m{\cdot}s^{-1}$ of wind velocity and 17cm of snow depth. Therefore it is difficult to apply this dimension to area with higher climate load. In order to sort out such problem, the rain shelter has been designed to avoid damage on frame by opening plastic film to the ridge. Once greenhouse band is loosen by turning the manual switch at the both sides of rain shelter and open button of controller is pushed then switch motor rises up along the guide pipe and plastic film is opened to the ridge. Chinese cabbage can be damaged by insects if rain shelter is opened completely as revealed a field. To prevent this, farmers can install an insect-proof net. Further, the greenhouse can be damaged by typhoon while growing Chinese cabbage therefore the effect of an insect-proof net on structural safety has been analyzed. And then structural safety has been analyzed through using flow-structure interaction method at the wind condition of $40m{\cdot}s^{-1}$. And it assumed that wind applied perpendicular to side of the rain shelter which was covered by insect-proof net. The results indicated that plastic film was directly affected by wind therefore high pressure occurred on the surface. But wind load on insect-proof net was smaller than on plastic film and pressure distribution was also uniform. The results of structural analysis by applying pressure data extracted from flow analysis indicated that the maximum stress occurred at the end of pipe which is the ground part and the value has been 54.6MPa. The allowable stress of pipe in the standard of structural safety must be 215 MPa or more therefore structural safety of this rain shelter is satisfied.

Effects of an Improved Side Vent on Yield of Oriental Melon and Temperature in Single-span Plastic Greenhouse with Roof Ventilation Fans (지붕 환기팬이 설치된 단동 플라스틱 온실에서 개선된 측창형태가 하우스 내 온도 및 참외 수량에 미치는 영향)

  • Yu, In Ho;Cho, Myeong Whan;Ryu, Hee Ryong;Shin, Young An
    • Journal of Bio-Environment Control
    • /
    • v.26 no.4
    • /
    • pp.283-290
    • /
    • 2017
  • In this study, the method to attach plastic film on the side vent from inside of greenhouse for the entire length was developed as the way to make crops less stressful while uniformly getting outside air into the greenhouse when ventilating using roof ventilation fans at single-span plastic greenhouse for oriental melon in a low-temperature period. The plastic film was installed from ground to 10cm below from the height where side vent is fully opened. In order to verify that the improved side vent can improve greenhouse environment and fruit yield, it was compared with the control plot of conventional side vent. Both greenhouses were not ventilated until February 25th, 2017. Air temperature in both greenhouses exceeded $40^{\circ}C$ in mid February. Therefore, it is judged that the greenhouse should be ventilated from mid February. Air temperature in the control plot exceeded $30^{\circ}C$ from late April. Therefore, it is judged that the plastic film attached to the inside of side vent should be removed in late April, or in early May at the latest. Soil temperature in the treatment plot in the mid Aril exceeded $20^{\circ}C$, which is suitable for growth, while that in the control plot was still below $20^{\circ}C$. Soil temperature in the control plot finally exceeded $20^{\circ}C$ in late April. The consumption of electricity was 47.2 kWh in the treatment plot, and 48.3 kWh in the control plot, which was no significant difference. The marketable yield of oriental melon in the treatment plot was 5,094kg, which was 23.9% more than that in the control plot, 4,113kg. The marketable fruit ratio was 73.5% in the treatment plot, and that in the control plot was 73.9%, which was no significant difference.

Changes of Salt Concentration by the Height of Ground Water Table on Disused Saltpan for Golf Course Construction Site (골프코스를 조성할 폐염전 매립지의 지하수위에 따른 토양산도 및 전기전도도 변화)

  • Lee, Dong-Ik;Kim, Ki-Dong;Joo, Young-Kyoo
    • Asian Journal of Turfgrass Science
    • /
    • v.23 no.1
    • /
    • pp.143-150
    • /
    • 2009
  • High salt concentration is one of the most important limit factor on plant growth at a disused saltpan for golf course construction site. The control of salt in soil is definitely required and the monitoring of salt concentration in soil and ground water also required to amend soil physiochemical properties. This research was carried out to monitor the pH and salt concentration changes by the height of ground water. By the physiochemical analysis test, the soil contains a high salt concentration and classified as a slight alkaline clay soil. The height of ground water table changed to 1.3m, 3.3m and 2.8m at dry season(mid-late June, 2005), monsoon season(early-mid July) and after monsoon(late July), respectively. Compare to the average ground level of 2.9m, the ground water was over flooded about OAm at monsoon season. The electrical conductivity(ECe) was measured above $4.0dS{\cdot}m^{-1}$ over all areas and however, some areas showed over $20dS{\cdot}m^{-1}$. During a monsoon season, ECe was lowered to $1.2{\sim}15.0dS{\cdot}m^{-1}$, compared with those of the dry season. Therefore, the interception of the capillary connection between planting layer and ground water which contains high salt concentration should be adapted when golf courses are constructed on disused saltpan. The phytotoxicity caused by salt damage may be controled by the interception of capillary fringe of salt flow to the topsoil profile at the upper layer of the ground water table.