• 제목/요약/키워드: 비점수차법

검색결과 10건 처리시간 0.029초

비점수차법을 이용한 변위센서 개발 (Micro Displacement Sensor Using an Astigmatic Method)

  • 이창우;송준엽;하태호;김준현
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2006년도 춘계학술대회 논문집
    • /
    • pp.257-258
    • /
    • 2006
  • This paper presents the displacement sensor based on astigmatic method that has a small measurement range. The sensor has the characteristic that the measuring range is changed easily by exchanging a objective lens or distance between a objective lens and a collimator lens. The measuring range and resolution is evaluated by a laser interferometer.

  • PDF

비점수차법을 이용한 초정밀변위측정법 연구 (Precision Displacement Measurement Using Astigmatism)

  • 이상헌;정광석
    • 한국정밀공학회지
    • /
    • 제25권7호
    • /
    • pp.87-94
    • /
    • 2008
  • The displacement sensor using optical pickup head is presented. The measuring principle of optical pickup head in focusing direction is adopted to measure displacement. The preliminary tests were carried out to verify the feasibility of the optical pickup head as a displacement sensor and optical pickup head showed about $8\;{\mu}m$ measuring range and 10nm resolution. The methodology to expand measuring range is proposed and proved its validity. The proposed displacement sensors are applied to AFM(Atomic Force Microscope) probe head to measure the deflection of micro-cantilever.

북스펙트럼 스펙클 영상법의 성능기준 (Performance Criterion of Bispectral Speckle Imaging Technique)

  • 조두진
    • 한국광학회지
    • /
    • 제4권1호
    • /
    • pp.28-35
    • /
    • 1993
  • 수차가 정확히 알려지지 않은 결상계에 있어서, exit pupil에 인위적인 위상의 random fluctuation을 도입하고 북스펙트럼 스펙클 영상법(bispectral speckle imaging)을 이용하므로서 수차의 효과를 극소화하여 거의 회절한계의 영상을 얻을 수 있다. Defocus, 구면수차, 코마수차, 비점수차가 각각 1파장씩 있을 때, 주어진 사용영상수(50개)에 대해서 Gaussian random phase model의 correlation length가 어느 정도일 때 최적의 결과를 얻을 수 있는지를 점 물체에 대해 컴퓨터 시뮬레이션을 시행하므로서 연구하였다. 평가기준으로서는 복원된 점물체에 대한 point spread function의 FWHM, normalized peak intensity, MTF 그리고 visual inspection을 채용하였는데, exit pupil 위에서 Fried parameter ${\Upsilon}_0$ 범위에 대한 수차의 차의 rms값 $\sigma$가 구면수차에 대해서는 0.27~0.53 파장일 때, defocus와 비점수차에 대해서는 0.24~0.36 파장일 때, 좋은 결과를 주는 것으로 나타났고, 코마수차의 경우에는 좋은 결과를 얻을 수 없었다.

  • PDF

랜드/그루브 기록 광디스크에 대한 포커스 에러 신호 분석 (Analysis of focus error signals on land/groove recordable optical disks)

  • 이용재;박병호;신현국
    • 한국광학회지
    • /
    • 제8권1호
    • /
    • pp.73-79
    • /
    • 1997
  • 랜드/그루브 기록 광디스크에서 랜드와 그루브의 영향, 각종 수차 그리고 수광계의 변화가 포커스에러신호에 미치는 영향을 나이프엣지법과 비점수차법으로 구분하여 시뮬레이션을 통해 분석하였다. 그루브의 영향에 의해 포커스에러신호에서 Aero Cross 점이 Shift되는데, 이는 디스크 반사 회절빔의 파면이 Defocus 성분을 포함하고 있기 때문이라는 것을 밝혔다. 또한 회절빔의 각 차수별로 포커스에러신호를 분석함으로써 빔점수차 방식에서 랜드와 그루브의 영향으로 에러신호의 감도가 감소함을 보았다.

  • PDF

적외선 및 가시광선 결상용 3반사망원경계의 설계 (Optical design of three-mirror telescope system for infra-red and visible imaging)

  • 이종웅;홍경희;권우근
    • 한국광학회지
    • /
    • 제7권3호
    • /
    • pp.183-190
    • /
    • 1996
  • 적외선, 가시광선 겸용의 3반사망원경계를 설계하기 위하여 형상설계법 및 3차수차의 보정방법이 연구되었다. 적외선용의 광학계는 3반사경계만으로 구성되었으며 원추곡면화를 통하여 구면수차, 코마, 비점수차를 보정하였다. 가시광선용의 광학계는 적외선용의 3반사경계의 상면앞에 보정렌즈를 추가하여 상면만곡을 보정하였다. 설계된 3반사망원경계는 파장 10.mu.m에서는 시계 2.4.deg. 내에서 회절한계의 결상성능을 가지고 있다. 가싣광선대역의 단파장에 대한 rms spot size는 3.deg. 시계내에서 25.mu.m이하이며, CCD의 사용에 적합하도록 flat field 조건을 만족하고 있다.

  • PDF

4세대 박형 CD 광학 픽업 개발 (Development of the 4th Generation CD Optical Pick-up with Small Thickness)

  • 최영석;김성근
    • 한국정밀공학회지
    • /
    • 제15권3호
    • /
    • pp.38-49
    • /
    • 1998
  • The 3rd generation optical pick-up used popularly in resent years is composed of many optical and electronic components such as laser diode, photo diode, beam splitter, objective lens, grating lens, concave lens, collimator lens etc. Therefore, the design of its optical system and its main base which the said optical and electronic components are set on, is complicated and needs high precision. Its assembly and adjustment in the production line is also difficult. This complication and the demand of high precision get its production cost to be high and its reliability to be low. In this paper, the 4th generation optical pick-up is designed and developed, with the hologram device which laser diode. photo diode, beam splitter. and grating lens are integrated in. This optical pick-up reduces the number of points of adjustment by 3, compared with the 3rd generation optical pick-up of which the number of points of adjustment is 6. This optical pickup also decreases by 4 the number of points of W bonding to have bad influence on environmental reliability, decreases by about 10 the number of parts, and establishes about 20% cost-down of material cost, compared with the 3rd generation optical pick-up.

  • PDF

선명한 주변시를 가진 근시용 비구면 안경렌즈 설계와 초정밀 가공 특성 (Design of Myopic Aspherical Ophthalmic Lenses with Peripheral Clear Vision and Properties of Its Ultra-Precision Machining)

  • 김동익;허명상;이길재;박순섭;원종호;김건희
    • 한국정밀공학회지
    • /
    • 제29권12호
    • /
    • pp.1290-1295
    • /
    • 2012
  • Oblique astigmatism according to the rotation of the eye has to be removed for obtaining peripheral clear vision in ophthalmic lenses. For this reason, we calculated tangential and sagittal power using third-order approximation theory and then controlled conic constant for the difference of the two powers to converge to 0 regardless of the rotation angle of the eye. As a result, an aspherical ophthalmic lens without oblique astigmatism was designed. Also, we found optimal machining condition to the lens material using factorial design and finally fabricated the designed lens through ultra-precision machining with that condition.

이중 정합법을 이용한 볼록비구면 반사경의 형상 오차 측정 (Surface-error Measurement for a Convex Aspheric Mirror Using a Double-stitching Method)

  • 김고은;이윤우;양호순
    • 한국광학회지
    • /
    • 제32권6호
    • /
    • pp.314-322
    • /
    • 2021
  • 일반적인 반사식 망원경은 오목 형태의 주경과 볼록 형태의 부경으로 구성되어 있다. 주경은 크기가 크지만 빛을 모아주는 특성으로 반사경의 파면오차 측정이 비교적 용이하다. 반면에 부경은 빛을 퍼트리기 때문에 주경보다 크기는 작지만 측정의 난이도는 더 높다고 할 수 있다. 특히 코시(Korsch) 형태의 망원경에서는 부경의 가운데 영역도 사용하는데 기존의 힌들(Hindle) 측정법으로는 가운데 부분을 측정할 수 없다. 본 논문에서는 크기가 큰 볼록비구면을 측정하기 위해 힌들 정합법(힌들 측정법과 정합법의 결합)을 적용하여 측정하고 이 측정에서 빠지는 가운데 영역은 일반간섭계의 구면파를 이용해 측정하여 두 결과를 합쳐 전체 형상 오차를 획득하는 방법을 제안하고자 한다. 제안한 방법으로 직경 202 mm, 곡률 반경 499 mm, 비구면상수 -4.613의 볼록 비구면의 형상 오차를 측정한 결과 19.5±1.3 nm rms로 측정되었다. 이 결과는 상용 정합 측정 장비로 측정한 결과와 0.7 nm rms의 근소한 차이를 보였고 반사경의 형상 오차가 45도 방향 비점수차를 가지는 것것도 일치하였다. 따라서 본 논문에서 제안한 방법이 볼록 비구면의 전체 영역을 정밀하게 측정하는데 유용함을 알 수 있었다.

카세그레인 망원경의 볼록비구면 반사경 파면오차 측정 (Testing of a Convex Aspheric Secondary Mirror for the Cassegrain Telescope)

  • 김고은;이혁교;양호순
    • 한국광학회지
    • /
    • 제28권6호
    • /
    • pp.290-294
    • /
    • 2017
  • 카세그레인 망원경은 오목한 주경과 볼록한 부경으로 이루어져있다. 특히 부경의 경우 크기는 작지만 볼록한 형태로 빛을 모두 퍼트려 파면오차 측정이 어렵다. 본 논문에서는 비구면 계수가 여러 개인 볼록비구면 반사경의 파면오차를 Simpson-Oland-Meckel (SOM) 힌들 테스트를 적용하여 측정하였다. 그리고 실험 구성에서 발생하는 계통오차를 분리해내기 위해 QN 절대측정법을 추가로 적용함으로써 힌들 렌즈 제작 및 정렬 오차를 포함한 계통오차를 보정하고 볼록비구면 반사경만의 파면오차를 구하였다. 이렇게 구한 볼록비구면 반사경의 파면오차와 QED사의 ASI (Aspheric Stitching Interferometer)로 측정한 파면오차와 비교한 결과, 모두 $45^{\circ}$ 방향의 비점수차 형태를 가지며 rms 값의 차이가 약 2.5 nm rms 이내로 매우 작음을 확인하였다.