• Title/Summary/Keyword: 비례하중

Search Result 119, Processing Time 0.024 seconds

Comprarison of Yasufuku's Single Hardening Constitutice Model and Lade's Double Hardening Constitutive Model for Compacted Weathered Granite Soil (다짐화강토에 대한 Yasufuku 의 단일항복면 구성모델과 Lade의 복합항복면 구성모델의 비교)

  • 정진섭
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.41 no.3
    • /
    • pp.91-100
    • /
    • 1999
  • Tow constitutive models for weathered granite soil, Yasufuku's constitutive model with a single yield surface and Lade's constitutive model with two intersectiong yield surface compared in terms of their capabilities to accurately capture the observed behavior of compacted weathered grainite soil for various stress-paths. Both the single surface and the double surface models capture the experimentally observed behavior at a variety of stress-paths with good accuracy. The double surface model may model the observed compacted weathered granite soil behavior with better accuracy for proportational loading with increasing stress, but the single surface model may model dilatancy property with better accuracy for p-constant loading with increasing stress ratio.

  • PDF

Wave Forces Acting on a Cylindrical Aquaculture Fish Cage (원통형 양식시설물에 작용하는 파랑하중)

  • Cho, Il-Hyoung
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.23 no.1
    • /
    • pp.63-69
    • /
    • 2011
  • In this paper, the wave forces on a cylindrical aquaculture fish cage, which consists of the porous mesh with the uniform porosity, are analyzed using matched eigenfunction expansion method. The boundary condition on the porous net is derived based on the Darcy's law, which implies that the velocity of the fluid passing through the net is linearly proportional to the pressure difference between two sides of the net. The wave forces and wave responses are investigated by changing the porous parameter of porous net as well as the submerged position (floating type, bottom-mounted type) of an aquaculture fish cage. It is found that the wave forces on a bottom-mounted type are largely decreased compared with that on a floating type. Also, the porosity of the netting structure plays an important role in reducing the wave forces and the wave elevation in the vicinity of an aquaculture fish cage.

Earth Pressure on a Rigid wall due to Loads Condition and Distance (상재하중의 크기와 이격거리에 따른 강성벽체의 토압분포)

  • Oh, Bun-Jin;Lee, Sang-Duk
    • Journal of the Korean Geotechnical Society
    • /
    • v.26 no.12
    • /
    • pp.51-60
    • /
    • 2010
  • Earth pressure due to gravity generally increases linearly with the depth, but the distribution of earth pressure due to surface load depends on the loading condition, the ground condition, and the boundary condition. In this study, the earth pressure on a rigid wall due to the vertical surface load was measured in experiments. Rigid wall was built in the model test box, and it was filled with homogeneous sandy ground (width 30 cm, height 88 cm, length 110 cm). Rigid wall was composed of 8 segments, which were tested on the two load cells. In the tests, we observed the distribution of the earth pressure on the rigid wall depending on the vertical surface load and it's location. According to the test results, the lateral earth pressure due to the vertical surface load showed its maximum value at a constant depth and decreased with the depth, to the negligible value at the critical depth. The critical depth and the depth at which lateral earth pressure reaches its maximum were not decided by the magnitude of the vertical surface load. They were dependant on the distance from the rigid wall.

Determination of the Collapse Load of Elastic-Perfectly Plastic Frame Under the Probabilistic Load Incremental Method (확률특성을 고려한 탄성-완전소성 뼈대 구조물의 붕괴하중 산정)

  • 윤성수;장주흠;김한중;이정재
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.40 no.2
    • /
    • pp.140-147
    • /
    • 1998
  • Since a structure carries out its given functions and purposes while it is always resisting against the external load, the capacity of the resistance in the structure within the range that will not collapse the structure itself becomes the important factor in the design of the structures. Therefore, many suggestions were proposed and noted for determining method of the collapse load. Some of the methods from the suggestions have been commonly used due to the considerations on their distinctive advantages such as the compactness of the conceptions and the convenience in the computation. However, in case when the variation becomes huge in the materials and load, the results would carry(have or contain) many uncertain elements. On the other hand, load incremental method which regards the characteristics of the probability must be more attainable method even though it might complicate the calculation. This study intends to develop a finite element model that uses the probabilistic load incremental method to estimate the collapse load, and also to compare the result of the analysis with the linear load incremental method and Turkstra's Rule.

  • PDF

A Study on the Analysis of Steel Bracing Behaviour Subjected to Cyclic Loads (반복하중을 받는 강재 브레이싱의 거동에 관한 해석적 연구)

  • 구민세;김병석;김일곤
    • Computational Structural Engineering
    • /
    • v.2 no.3
    • /
    • pp.69-75
    • /
    • 1989
  • The primary purpose of using bracings is to improve the lateral rigidity of main structural system, i.e., columns and beams, by reinforciing them with much smaller members. In conventional design methods brackings are considered as tension-only members, since difficulties arise in the analysis when the P-.DELTA. effects and post-buckling behaviour of the bracing members are taken into account. This is particulary true fox X-bracings. Recently, however, both analytical and experimental studies have been conducted to investigate the more precise and real behaviour of bracing members, especially for the nonlinear and plastic behaviour under cyclic loads. In this study, an analytical model is proposed to investigate the nonlinear behavior of steel bracing members subjected to cyclic loads. Results of the analysis were compared with previous experimental results, and good agreements were obtained between these results.

  • PDF

A study on proportional multiple-resonance controller for harmonic distortion compensation of single phase VSIs (단상 전압 소스 인버터의 고조파 왜곡 보상을 위한 비례 다중 공진 제어기에 관한 연구)

  • Bongwoo Kwak
    • Journal of IKEEE
    • /
    • v.27 no.3
    • /
    • pp.319-326
    • /
    • 2023
  • In this paper, simulation and experimental results are presented, including the implementation of a digital controller for robust output voltage control of a single-phase voltage source inverters (VSIs) and total harmonic distortion (T.H.D.v) analysis. Typically, the VSIs uses a proportional integral (PI) controller for the current controller on the inner loop and a proportional resonant (PR) controller for the voltage controller on the outer loop to control the output voltage. However, non-linear loads still produce high-order odd harmonic distortion. Therefore, in this paper, a proportional multiple resonance (PMR) controller with a resonance controller for odd harmonic frequencies is proposed to suppress harmonic distortion. Analyze the frequency response of controllers for VSI plants and design PMR controllers. Through simulation, the total harmonic distortion characteristics of the output voltage are compared and verified when PI and PMR are used as voltage controllers. Both linear and non-linear loading conditions were considered. Finally, the effectiveness of the PMR controller was demonstrated by applying it to a 3kW VSIs prototype.

Numerical Analysis for the Pullout Behavior and Failure Mechanism of Ground Anchor (그라운드 앵커의 인발거동 및 파괴메카니즘에 대한 수치해석)

  • Park, Byung-Soo;Shim, Do-Sik
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.10 no.2
    • /
    • pp.69-76
    • /
    • 2010
  • This study is an numerical study of predicting the behavior of anchor embedded in weathered rocks, subjected to uplift loads, about ultimate pullout capacity and the failure mechanism. Factors influencing the behavior of anchors were investigated by reviewing the data about in-situ anchor tests performing numerical modelling with changing the bondage length of anchor, diameter of anchor body and diameter of tendon, and by correlations between those factors were evaluated to apply them to predict the behavior of anchors. As results of numerical analysis, a linear relationship between bondage length, diameter of anchor body and diameter of tendon with ultimate pullout capacity was obtained on the one hand, from the result of numerical analysis changing the Young's modulus of weathered rock, this parameter was found to influence to load-displacement and ultimate pullout capacity within the range of 10%, which was not so significant to affect.

Accumulated Rotations of Suction Bucket Foundations under Long-term Cyclic Loads in Dry Sandy Ground (건조 사질토 지반에 설치된 석션 버켓기초의 장기 반복하중에 의한 누적회전각 산정)

  • Lee, Si-Hoon;Choi, Changho;Kim, Sung-Ryul
    • Journal of the Korean Geotechnical Society
    • /
    • v.32 no.12
    • /
    • pp.69-78
    • /
    • 2016
  • A suction bucket foundation has been considered to be a potential foundation type for offshore wind turbines. A suction bucket foundation is usually installed in soft soil, so the accumulated displacement of the foundation may occur under long-term cyclic loads. In this study, a series of 1-g model tests were performed to analyze the accumulated rotation of suction bucket foundations under long-term cyclic horizontal loads. The dry model ground was prepared to have two different soil densities by air-pluviation method. The model tests were performed varying the embedment depth of the suction bucket, the soil density, and the amplitude of cyclic load. A one-way horizontal cyclic load was applied over $10^4$ cycles. Test results showed that the accumulated rotation of the suction bucket foundation increased with the increase in the number of cycles and load magnitudes. Based on the model test results, a new equation was proposed to evaluate the accumulated rotation of the suction bucket foundations in dry sandy ground under long-term cyclic horizontal loads.

Structural Optimization for Non-Linear Behavior Using Equivalent Static Loads by Proportional Transformation of Loads (비례하중변환법의 등가정하중을 이용한 비선형 거동을 하는 구조물의 최적설계)

  • Park Ki-Jong;Kwon Yong-Deok;Song Kee-Nam;Park Gyung-Jin
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.30 no.1 s.244
    • /
    • pp.66-75
    • /
    • 2006
  • Nonlinear response structural optimization using equivalent static loads (NROESL) has been proposed. Nonlinear response optimization is solved by sequential linear response optimization with equivalent static loads which are generated from the nonlinear responses and linear stiffness matrix. The linear stiffness matrix should be obtained in NROESL, and this process can be fairly difficult for some applications. Proportional transformation of loads (PTL) is proposed to overcome the difficulties. Equivalent static loads are obtained by PTL. It is the same as NROESL except for the process of calculating equivalent static loads. PTL is developed for large-scale probems. First, linear and nonlinear responses are evaluated from linear and nonlinear analyses, respectively. At a DOF of the finite element method, the ratio of the two responses is calculated and an equivalent static load is made by multiplying the ratio and the loads for linear analysis. Therefore, the mumber of the equivalent static loads is as many as that of DOF's and an equivalent static load is used with the reponse for the corresponding DOF in the optimization process. All the equivalent static loads are used as multiple loading conditions during linear response optimization. The process iterates until it converges. Examples are solved by using the proposed method and the results are compared with conventional methods.

Bond Characteristics of High-Strength Concrete (고장도 콘크리트의 부착특성에 관한 연구)

  • Lee, Joon-Gu;Mun, In;Yum, Hwan-Seok;Kim, Woo
    • Journal of the Korea Concrete Institute
    • /
    • v.13 no.5
    • /
    • pp.499-506
    • /
    • 2001
  • Eight direct tension tests were conducted to study the bond characteristics and crack behavior in high-strength concrete axial members. The main variable was the concrete strength up to 61-63 MPa. The specimens consisted of two different types of the short specimens modeled the part between transverse cracks and the long specimens having numerous transverse cracks. The results obtained show that the bond strength increases in proportion to compressive strength. Thereby, in high-strength concrete the length of stress-disturbed region is shortened and the space of adjacent transverse cracks become smaller. Although the concrete strength varies from 25 MPa to 61 MPa, the split cracking loads remain constant, while transverse cracking loads vary as variation of concrete tensile strength. Accordingly, the current code provisions for development length may need reconsideration in high-strength concrete members, and it is recommended that either thicker cover or transverse reinforcement should be additionally provided for high-strength concrete members.