• Title/Summary/Keyword: 비디오 추적

Search Result 295, Processing Time 0.031 seconds

A Study on a Violence Recognition System with CCTV (CCTV에서 폭력 행위 감지 시스템 연구)

  • Shim, Young-Bin;Park, Hwa-Jin
    • Journal of Digital Contents Society
    • /
    • v.16 no.1
    • /
    • pp.25-32
    • /
    • 2015
  • With the increased frequency of crime such as assaults and sexual violence, the reliance on CCTV in arresting criminals has increased as well. However, CCTV, which should be monitored by human labor force at all times, has limits in terms of budget and man-power. Thereby, the interest in intelligent security system is growing nowadays. Expanding the techniques of an objects behavior recognition in previous studies, we propose a system to detect forms of violence between 2~3 objects from images obtained in CCTV. It perceives by detecting the object with the difference operation and the morphology of the background image. The determinant criteria to define violent behaviors are suggested. Moreover, provable decision metric values through measurements of the number of violent condition are derived. As a result of the experiments with the threshold values, showed more than 80% recognition success rate. A future research for abnormal behaviors recognition system in a crowded circumstance remains to be developed.

A Recognition Framework for Facial Expression by Expression HMM and Posterior Probability (표정 HMM과 사후 확률을 이용한 얼굴 표정 인식 프레임워크)

  • Kim, Jin-Ok
    • Journal of KIISE:Computing Practices and Letters
    • /
    • v.11 no.3
    • /
    • pp.284-291
    • /
    • 2005
  • I propose a framework for detecting, recognizing and classifying facial features based on learned expression patterns. The framework recognizes facial expressions by using PCA and expression HMM(EHMM) which is Hidden Markov Model (HMM) approach to represent the spatial information and the temporal dynamics of the time varying visual expression patterns. Because the low level spatial feature extraction is fused with the temporal analysis, a unified spatio-temporal approach of HMM to common detection, tracking and classification problems is effective. The proposed recognition framework is accomplished by applying posterior probability between current visual observations and previous visual evidences. Consequently, the framework shows accurate and robust results of recognition on as well simple expressions as basic 6 facial feature patterns. The method allows us to perform a set of important tasks such as facial-expression recognition, HCI and key-frame extraction.

Implement of Finger-Gesture Remote Controller using the Moving Direction Recognition of Single (단일 형상의 이동 방향 인식에 의한 손 동작 리모트 컨트롤러 구현)

  • Jang, Myeong-Soo;Lee, Woo-Beom
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.13 no.4
    • /
    • pp.91-97
    • /
    • 2013
  • A finger-gesture remote controller using the single camera is implemented in this paper, which is base on the recognition of finger number and finger moving direction. Proposed method uses the transformed YCbCr color-difference information to extract the hand region effectively. The number and position of finger are computer by using a double circle tracing method. Specially, a user continuous-command can be performed repeatedly by recognizing the finger-gesture direction of single shape. The position information of finger enables a user command to amplify a same command in the User eXperience. Also, all processing tasks are implemented by using the Intel OpenCV library and C++ language. In order to evaluate the performance of the our proposed method, after applying to the commercial video player software as a remote controller. As a result, the proposed method showed the average 89% recognition ratio by the user command-mode.

Resource Reservation Based Image Data Transmission Scheme for Surveillance Sensor Networks (감시정찰 센서 네트워크를 위한 자원예약 기반 이미지 데이터 전송 기법)

  • Song, Woon-Seop;Jung, Woo-Sung;Ko, Young-Bae
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.39C no.11
    • /
    • pp.1104-1113
    • /
    • 2014
  • Future combat systems can be represented as the NCW (Network Centric Warefare), which is based on the concept of Sensor-to-Shooter. A wireless video sensor networking technology, one of the core components of NCW, has been actively applied for the purpose of tactical surveillance. In such a surveillance sensor network, multi-composite sensors, especially consisting of image sensors are utilized to improve reliability for intrusion detection and enemy tracing. However, these sensors may cause a problem of requiring very high network capacity and energy consumption. In order to alleviate this problem, this paper proposes an image data transmission scheme based on resource reservation. The proposed scheme can make it possible to have more reliable image data transmission by choosing proper multiple interfaces, while trying to control resolution and compression quality of image data based on network resource availability. By the performance analysis using NS-3 simulation, we have confirmed the transmission reliability as well as energy efficiency of the proposed scheme.

Efficient Scheduling of Sensor-based Elevator Systems in Smart Buildings (스마트 빌딩을 위한 센서 기반의 효율적인 엘리베이터 스케줄링)

  • Bahn, Hyokyung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.10
    • /
    • pp.367-372
    • /
    • 2016
  • In a modern smart building, sensors can detect various physical conditions, such as temperature, humidity, sound, motion, and light, which can be used in medical services and security, and for energy savings. This paper presents an efficient elevator scheduling system that utilizes smart sensor technologies with radio-frequency identification, video, and floor sensors to detect the arrival of elevator users in advance. The detected information is then delivered to the elevator scheduling system via building networks. By using this information, the proposed system makes a reservation call for efficient control of the elevator's direction and time. Experiments under a spectrum of traffic conditions show that the proposed system performs better than a legacy system with respect to average wait time, maximum wait time, and energy consumption.

Experimental studies on surface resistance method of levee based on bio-polymer (바이오폴리머 기반 제방 표면 강화 공법에 대한 실험적 연구)

  • Ko, Dongwoo;Kang, Joongu
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2019.05a
    • /
    • pp.50-50
    • /
    • 2019
  • 최근 국지성 호우 및 하천 제방의 노후화로 인한 제방 붕괴 피해가 빈번히 발생하면서 제방의 안정성 및 표면 보강을 위한 다양한 연구가 시도되고 있다. 본 연구에서는 제방 붕괴에 따른 피해 최소화 및 대책을 수립하기 위한 방법으로 시멘트와 같은 지구온난화를 야기시키는 물질이 아닌 친환경 신소재 바이오폴리머를 흙과 혼합한 재료를 활용하여 제방의 내구성을 강화하기 위한 연구가 수행되고 있다. 이에 안동하천실증연구센터에서는 현장토를 사용하여 높이 1 m, 폭 3 m, 사면경사 1 : 2, 총 길이 5 m 의 중규모 제방모형을 제작하였으며, 공동연구기관인 카이스트에서 개발된 바이오폴리머와 흙을 적정 비율로 혼합한 바이오-소일을 제방 전면에 일정 두께로 피복하여 월류 발생에 따른 제방 안정성 평가 실험을 수행하였다. 1차 실험은 흙 제방 조건이며, 2 3차 실험은 제방 표면에 5 cm 두께로 신소재가 피복된 조건으로 안정된 결과 도출을 위해 반복 실험을 수행하였다. 제방 천단면 및 사면에서의 유속분포를 측정하기 위해 드론 및 비디오카메라를 활용한 LSPIV 기법을 적용하여 실험조건에 따른 표면유속과 월류 흐름이 제방 붕괴에 미치는 영향에 대해 비교분석하였다. 또한 그래픽 소프트웨어를 이용한 픽셀기반 영상분석 기법을 적용하여 시간에 따른 제방사면의 붕괴면적을 산정하여 신소재 피복에 따른 붕괴 지연효과 분석을 통한 신소재 활용 제방의 현장 적용가능성 및 안정성을 평가하였다. 본 연구결과, 흙 제방의 경우 월류 흐름 발생 직후 침식현상이 전개되어 유속분포가 집중되고 있었으며, 이후 발생하는 강한 수직흐름으로 인해 입자추적을 통한 분석이 더 이상 불가능하였다. 신소재 제방의 경우 월류 흐름 발생 직후 침식은 발생하지 않았으며 일정시간동안 유속분포가 유지되었다. 지속적인 월류 흐름으로 인해 제방 끝단에서 침식이 발생하였으며 이때 최대 유속은 3.3 m/s 로 나타났다. 또한 픽셀기반 분석을 통해 30초 단위로 표면손실률을 산정한 결과, 신소재 활용 제방(2, 3차)의 경우 같은 실험조건에도 불구하고 최종 붕괴시간은 약 3배의 차이를 보였으며, 양생 과정에서의 크랙 발생을 최소화한다면 월류 발생 시 상당한 붕괴지연효과가 있는 것으로 판단된다.

  • PDF

The Sympathetic Skin Responses after Thoracic Sympathicotomy for Patients with Palmar Hyperhidrosis (수장부 다한증환자의 흉부 교감신경절단술후 교감신경 피부반응)

  • 김오곤;홍종면;이석재;홍장수;이광래;김상규
    • Journal of Chest Surgery
    • /
    • v.32 no.6
    • /
    • pp.579-583
    • /
    • 1999
  • Background: Thoracic sympathicotomy has been used safely and successfully to manage palmar hyperhidrosis. The preoperative and postoperative recording of Sympathetic Skin Responses(SSR) was performed for objective evaluation and follow-up of thoracic sympathicotomy in hyperhidrosis patients, and also for ascertaining the clinical usefullness of SSR. Material and Method: The recording of SSR was performed on 15 patients suffering from palmar hyperhidrosis with Medelec Sapphire Plus electromyogragh before and after thoracic sympathicotomy. Eletrical stimuli on the right median nerve was made in patients in supine position and results were recorded on right and left palms with soles at the same time by 4 channels. Skin temperatures were also monitored simultaneously. T2,3 sympathicotomy was performed with VATS in every patients. SSR was done in 2 patients one month later. Result: Clinically, all patients had symptomatic improvement with satisfaction. Postoperative complication was small amount of residual pneumothorax in 5 patients but it was absorbed sponteneously. There was no recurrence during follow-up period and ten patients(66%) complained compensatory hyperhidrosis. After operation, SSR change was shown in every 15 patients. Abolition of SSR on both palms was achieved in 12 patients(80%) and on both soles in 6 patients. In the other 3 patients, the latencies were significantly delayed and the amplitudes were significantly reduced at both palms and soles. In two patients who were examined at one month later after operation, similar results with postoperative SSRs were shown. The skin temperature on preoperative both palm and sole were lower than normal temperature, and those on postoperative both palm and sole were increased. Those had statistical significance(p<0.05), and the temperature on the palm was increased higher that than on the sole. Conclusion: After thoracic sympathicotomy was performed on palmar hyperhidrosis patients, an increment of skin temperatures and SSR changes were achieved at both palms and soles of all patients. Palmar SSRs were completely abolished in 12 patients(80%), and similar results of postoperative SSRs were achieved. The recording of SSR may be useful to easily and objectively assess the completeness of sympathicotomy and the follow-up of recurrence in hyperhidrosis patients.

  • PDF

Clinical Features of Cricopharyngeal Incoordination in Newborns and Infants (신생아 및 영아기 윤상인두 협조불능의 임상적 고찰)

  • Han, Young-Mi;Park, Jae-Hong
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.11 no.2
    • /
    • pp.116-121
    • /
    • 2008
  • Purpose: Cricopharyngeal incoordination is a rare cause of swallowing difficulties in newborns and infants; it is characterized by delayed pharyngeal contractions related to cricopharyngeal relaxation. Dysphagia and repeated aspiration are common findings despite normal sucking. We conducted this study to assess the clinical features of cricopharyngeal incoordination in newborns and infants. Methods: An analysis of the clinical data from 17 patients with cricopharyngeal incoordination who were admitted to the Department of Pediatrics, Pusan National University Hospital, between 2000 and 2006 was conducted retrospectively. The diagnosis of cricopharyngeal incoordination was established by the clinical characteristics and the videofluoroscopic swallowing studies. Results: The male to female ratio was 1:1.1 (males 8, females 9) the age range 1 to 60 days. The body weight of 11 patients (64.7%) was less than the $10^{th}$ percentile at diagnosis. Six patients (35.3%) were born prematurely. The associated anomalies or diseases were chromosomal anomaly (2 cases), congenital heart disease (3 cases), and laryngomalacia, hypoxic brain damage or neonatal seizures (1 case each). The chief complaints of patients were recurrent aspiration pneumonia (10 cases), feeding difficulty (9 cases), dyspnea (4 cases), and chocking (4 cases). The severity of aspiration on the videoesophagogram or esophagogram was mild in 12 cases. The correlation between the severity of aspiration and the duration of tube feeding after the diagnosis was significant (p<0.05). Conclusion: Cricopharyngeal incoordination should be considered in the differential diagnosis of newborns and infants, without known risk factors associated with swallowing dysfunction, when they present with unexplained respiratory problems. Although the prognosis of cricopharyngeal incoordination is good, early diagnosis and tube feeding are recommended to prevent the complications associated with this disorder.

  • PDF

Development of an Offline Based Internal Organ Motion Verification System during Treatment Using Sequential Cine EPID Images (연속촬영 전자조사 문 영상을 이용한 오프라인 기반 치료 중 내부 장기 움직임 확인 시스템의 개발)

  • Ju, Sang-Gyu;Hong, Chae-Seon;Huh, Woong;Kim, Min-Kyu;Han, Young-Yih;Shin, Eun-Hyuk;Shin, Jung-Suk;Kim, Jing-Sung;Park, Hee-Chul;Ahn, Sung-Hwan;Lim, Do-Hoon;Choi, Doo-Ho
    • Progress in Medical Physics
    • /
    • v.23 no.2
    • /
    • pp.91-98
    • /
    • 2012
  • Verification of internal organ motion during treatment and its feedback is essential to accurate dose delivery to the moving target. We developed an offline based internal organ motion verification system (IMVS) using cine EPID images and evaluated its accuracy and availability through phantom study. For verification of organ motion using live cine EPID images, a pattern matching algorithm using an internal surrogate, which is very distinguishable and represents organ motion in the treatment field, like diaphragm, was employed in the self-developed analysis software. For the system performance test, we developed a linear motion phantom, which consists of a human body shaped phantom with a fake tumor in the lung, linear motion cart, and control software. The phantom was operated with a motion of 2 cm at 4 sec per cycle and cine EPID images were obtained at a rate of 3.3 and 6.6 frames per sec (2 MU/frame) with $1,024{\times}768$ pixel counts in a linear accelerator (10 MVX). Organ motion of the target was tracked using self-developed analysis software. Results were compared with planned data of the motion phantom and data from the video image based tracking system (RPM, Varian, USA) using an external surrogate in order to evaluate its accuracy. For quantitative analysis, we analyzed correlation between two data sets in terms of average cycle (peak to peak), amplitude, and pattern (RMS, root mean square) of motion. Averages for the cycle of motion from IMVS and RPM system were $3.98{\pm}0.11$ (IMVS 3.3 fps), $4.005{\pm}0.001$ (IMVS 6.6 fps), and $3.95{\pm}0.02$ (RPM), respectively, and showed good agreement on real value (4 sec/cycle). Average of the amplitude of motion tracked by our system showed $1.85{\pm}0.02$ cm (3.3 fps) and $1.94{\pm}0.02$ cm (6.6 fps) as showed a slightly different value, 0.15 (7.5% error) and 0.06 (3% error) cm, respectively, compared with the actual value (2 cm), due to time resolution for image acquisition. In analysis of pattern of motion, the value of the RMS from the cine EPID image in 3.3 fps (0.1044) grew slightly compared with data from 6.6 fps (0.0480). The organ motion verification system using sequential cine EPID images with an internal surrogate showed good representation of its motion within 3% error in a preliminary phantom study. The system can be implemented for clinical purposes, which include organ motion verification during treatment, compared with 4D treatment planning data, and its feedback for accurate dose delivery to the moving target.

Effects of Intraoperative Doxycycline Pleurodesis with Concomitant Video-assisted Thoracoscopic Bullectomy (흉강경을 이용한 폐기포절제 수술과 동시에 시행한 Doxycycline Pleurodesis의 효과)

  • Kim, Hyeong-Guk;Han, Jae-Yeol;Kim, Gwang-Ho;Kim, Jeong-Taek
    • Journal of Chest Surgery
    • /
    • v.29 no.1
    • /
    • pp.59-62
    • /
    • 1996
  • Chemical pleurodesis with doxycycline has been used during video-assisted thoracoscopic surgery (VATS) as an auxiliary method to enhance therapeutic goal in patients with pneumothorax. However, the therapeutic effect of doxycycline pleurodesis (DP) has not been clearly defined yet. To evaluate the effect of DP, we compared two groups of patients who were given VATS bullectomy from October 1993 to June 1995. Group I composed of 21 patients who received DP and group II composed of 20 patients who did not received DP Doxycycline 500mg with saline 200ml were instilled into the pleural cavity upon a completion of bullec omy, and retained there for 0.5-1 hour and then drained out. The age of group I was 30.9 $\pm$ 20.0 and that of group II was 24.3 $\pm$ 9.49 years. Male to female ratio was 20: I in group I and 20 : 0 in group II. The postoperative indwelling time of chest tube was 5.86 $\pm$ 4.69 days in group I and 3.80 $\pm$ 2.28 days in group II. Seven patients had more than 100m1/day of chest tube drainage on the postoperative third day in group I compared to one patient in group II. Five patients had postoperative indwelling time of chest tube greater than 7 days in group I compared to two in group II. The number of patients who had postoperative fever were 3 in both group, analgesic requirements were 2.19 $\pm$ 2.77 amples in group I and 2.30 $\pm$ 1.95 ambles in group II. Follow-up was done from 2 months to 16 months after surgery. During the follow up periods, four patients had recurrence 2 (9.5%) in group I and 2 (10%) in group II. We conclude that concomitant doxycycline pleurodesis with video-assisted thor coscopic bullectomy In patients with pneumothorax is not necessary.

  • PDF